Laserfiche WebLink
W.R.B.TWO-PLY "WEATHER TEX" BY FORTIFIBER BUILDING SYSTEMS GROUP OR APPROVED EQUAL.WEATHER RESISTIVE BARRIER (W.R.B.), SUPER JUMBO TEX 60 MINUTE BUILDING PAPER OVERWEATHERSMART HOUSE WRAP.FORTIFIBER FORTIFLASH OR APPROVED EQUAL. SELF ADHESIVE, HEALING FLASHING (S.A.F.)12" WIDE (U.N.O.) 25 MIL (U.N.O.), 25 MIL (U.N.O.) ADHERE S.A.F. TO CLEAN, DUST FREE BACKINGAND USE CHEMICALLY COMPATIBLE PRIMERS & W.R.B. WITH ADHESIVE SIDE.S.A.F.GSM FLASHINGSTUCCO ACCESSORIES SHALL BE CEMCO "WATER MANAGEMENT SERIES", 25 GA. MATERIALWITH A G-90 GALVANIZED COATING OR ARCHITECT APPROVED EQUAL. GSM FLASHING METALSHALL BE SHOP FABRICATED USING A MINIMUM 26 GA. G-90 GALVANIZED SHEET METAL WITHSOLDERED JOINTS (U.N.O.), UNLESS NOTED OTHERWISE.ICC - ESR 2097 REPORT PLI-DEK “F” SYSTEM = PLI-DEK 1-HOUR / CLASS “A” FIRE RATEDIMPERVIOUS SURFACE, FIBERGLASS AND RESIN REINFORCED WATERPROOF DECK COATINGWITH KNOCKDOWN TEXTURE APPLIED AS PER MFG SPECIFICATIONS. COLOR TBD.WWW.PLIDEK.COM 800-364-0287IMPERVIOUS SURFACEALL DECK TO WALL/THRESHOLD TRANSITIONS TO BE PRE-TREATED WITH PD RESIN ANDREINFORCEMENT FABRIC PRIOR TO EXTENDED FOUNDATION SCREED INSTALLATION ANDAFTER BASE COAT INSTALLATION. GU80 TOP COAT AND GS88 PIGMENTED SEALER TO BEINSTALLED VERTICALLY IN CONJUNCTION WITH DECK SYSTEM FINISH COATS.PRE-TREATMENTEXT. GRADE PLYWOODSUBSTRATESLOPE2. 5 LBS / SQ.YD. GALVANIZED (DIPPED) EXPANDED METAL 96" X 27"LATHMINIMUM 3/4" EXTERIOR GRADE T&G, BLOCK ALL UNSUPPORTED JOINTS AND FASTEN WITHSCREWS AT DECKS. SEE STRUCTURAL DOCUMENTS FOR ADDITIONAL INFORMATION. COVERALL JOINTS WITH PLI-DEK SEAM PAPER. FOR RATED ASSEMBLY CONSTRUCTION, SEE ICC - ESR2097 REPORT, SECTION 4.4.1.1/4" = 1'-0", SLOPE MUST BE BUILT INTO FRAMED SUBSTRATE.CORROSION-RESISTANT STAPLES. FASTEN LATH TO EXTERIOR GRADE PLYWOOD.STAPLESWALL EDGE LAPNOTE: ALL FLASHING SEAMS AND LAPS SHALL BE INSTALLED AS TO NOT BUCK WATER.DRAIN MANUFACTURER - THUNDERBIRD PRODUCTS, 800-658-2743, THUNDERBIRDPRODUCTS.COMNP1 SONOLASTIC POLYURETHANE SEALANT OR APPROVED EQUAL. EXPOSED SEALANT SHALLBE CHECKED ANNUALLY AND MAINTAINED PER MANUFACTURERS RECOMMENDATION TOMAINTAIN A WATER TIGHT SEAL.SEALANTOVERUNDERSUBSTRATESLOPEREMOVABLE DRAIN CAPFOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILS2-4-2"MIN.8" <br />4 <br />" <br /> M <br />IN <br />IMUM <br /> <br />L <br />A <br />P <br />4PATIO TO WALL FLASHINGPATIO DRAIN15128NOTES101620PATIO AT CMU PLANTER WALLCON-DEK SYSTEM31112PATIO PLAN - LOW WALL WITH DRAINLAPPED GSM "L" FLASHING3 BEDS OF SEALANT 1" APARTCONTINUOUS BEAD OF SEALANT ATOVERLAP SEAMGSM "L" FLASHINGBOND BREAKERPOLYETHYLENE TAPE TO BE USED AS BOND BREAKER, REQUIRED BETWEEN ACRYLICPLASTER AND PAINT FINISHES AND ALL WEEPING SOLID LEG FLASHING. TAPE SHOULD RUNFROM THE SOLID VERTICAL LEG TO 1/8" FROM FRONT EDGE. ANY APPLIED FINISHE THATCREATES A BOND BETWEEN THE PLASTER AND METAL SHALL BE BROKEN WITH UTILITY KNIFEAND SHALL BE MAINTAINED AS SUCH.2" MIN.2" <br />6" <br />3/4"VERIFYCON-DEK SYSTEMASTM C-920POLYURETHANE JOINTSEALANT AFTER COMPLETIONOF CON-DEK FINISH COATCEMCO #7 WEEP SCREED WITHBOND BREAKER TAPEEXT.CEM. PLAS OVER5/8" TYPE "X" GYP BD O/PLYWD SHTG WHERE OCCURSSEE - SEE STRUCTURAL2X6 FRAMINGCON-DEK SYSTEM BY PLI-DECKSYSTEM OVER CONCRETESTRUCTURAL SLAB - SEESTRUCTURAL DRWGPLAN REFERENCESUBSTRATE TO DRAIN16 GAUGE STAINLESSSTRAINER (BY OTHERS)STRUCT. CONC. SLABCON-DEK SYSTEMBONDERIZED 26 GA GALV."L" FLASHING - ATTACHED WITHFASTENERS AS RECOMM. BYCON-DEK MANUF.GSM SCUPPERMIN. CON-DEK ASSEMBLY THICKNESSSECTION A: SCUPPER DRAINCONTINUOUS 1/2" BEAD OF SEALANTALL FOUR SIDES OF GSM "COLLAR"FLASHING3/4"HEM SIDE AND TOP EDGES OF GSM"SCUPPER" FLASHING TO ALIGN WITHEXTERIOR FINISH.EXTEND BOTTOM LOCK HOOK SEAMOF SCUPPER 3/4" BEYOND "COLLAR"FLASHING TO ACCOMMODATECONDUCTOR HEAD CONNECTIONWIDTH OF SCUPPER NOT TO EXCEED4" AT OCCUPIED ROOF.2"4"6"GSM "L" FLASHING LAPPED OVERSCUPPER3 BEDS OF SEALANT 1" APARTCONTINUOUS BEAD OF SEALANT ATOVERLAP SEAMCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONPARALLEL W/ IMPERVIOUS SURFACESCUPPER (DECK SIDE)SEE SCUPPER DETAIL. FOR ADDITIONAL INFORMATION SEE DETAILSOVEROVERUNDERAINTEGRAL STUCCO SCREED 3 SIDES.SEE PROFILE SECTIONSEALANT AT JOINT2-8-4"8"2" <br />6"4" MIN. LAP1"SEE SCUPPER DETAIL1"4" MIN. LAPSUBSTRATESLOPE2"IMPERVIOUSSURFACE STOP,HEIGHT TO TOP OFIMPERVIOUSSURFACEPOST(PER PLAN)IMPERVIOUS SURFACEPOST BASE PERSTRUCTURAL, GSM "L"FLASHING SHALL LIEVERTICALLY FLATAGAINST THE POST ANDPOST BASEPRE-TREATMENT O/ BASE COAT O/GSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONPARALLEL W/ IMPERVIOUS SURFACE3-COAT STUCCO SYSTEM O/ METALLATH O/ W.R.B.APPLY JOINT SEALANT AFTERCOMPLETION OF IMPERVIOUSSURFACE SYSTEM FINISH COATW.R.B. O/ S.A.F. O/ FOUNDATIONSCREED FLASHINGGSM "L"FLASHING2 PIECE "C" SHAPED GSM "L"FLASHING OVERLAP ASSEMBLY INTHE DIRECTION OF SLOPE"C" SHAPE SHALL BE PRE-MADE ANDSOLDEREDOVERUNDERNOTE:FLASHING SEAMS AND LAPS SHALL BE INSTALLED AS TO NOT BUCK WATER, SEE DETAIL"WALL FLASHING" FOR TYPICAL REQUIREMENTS AT LAP.2" <br />1 1/2"BUILD UP BASE COAT CRICKET WITH1/4" RISE ON UP SLOPE SIDE4"4"3"FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAIL2-8-SUBSTRATESLOPE3 1/2"MIN. LAPFOR ADDITIONAL INFO. ON SECTION A SEE DETAIL. FOR ADDITIONAL INFO. ON SECTION B SEE DETAIL . FOR ADDITIONAL REQUIREMENTS AND INFO. SEE DETAIL .BASADDLE FLASHINGIMPERVIOUS SURFACEPRE-TREATMENT O/ BASE COAT O/GSM DECK EDGE METALGSM DECK EDGE METAL3-COAT STUCCO SYSTEM O/ METALLATH O/ W.R.B.CEMCO # 66 EXPANDED FLANGECASING BEAD O/ W.R.B. O/ SADDLEFLASHING O/ S.A.F.CEMCO # 12 SOFFIT DRIP EDGE,EXTEND 1" PAST OPENING WHENDECK EDGE IS FLUSH WITH WALLBEYONDW.R.B. O/ S.A.F. O/ SOFFIT DRIPEDGECEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONPARALLEL W/ IMPERVIOUS SURFACEIMPERVIOUS SURFACE, OVERLAPLATH ON THE FLASHING TO THE EDGEOF THE DECK SURFACE3-COAT STUCCO SYSTEM O/ METALLATH O/ W.R.B. O/ S.A.F. O/ CEMCO #7PRE-TREATMENT O/ BASE COAT O/GSM "L" FLASHING 3" MIN. ABOVEFOUNDATION SCREED FLASHINGGSM "L" FLASHINGAPPLY SEALANT AFTER COMPLETIONOF IMPERVIOUS SURFACE SYSTEMFINISH COATSECTION ASECTION BCONC. DECKSURFACEGSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONGSM EDGE FLASHINGSADDLE FLASHINGS.A.F.W.R.B.CEMCO # 66 EXPANDED FLANGECASING BEADSADDLE FLASHING2"10-8-2-CONC.PATIOSLOPECONC.DECKSLOPECONC.DECKSLOPE12" S.A.F.4"S.A.F.4"WALLCONC. DECKSURFACEGSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONPRE-MADE CORNER GSM EDGEFLASHINGSADDLE FLASHINGCONC.DECKSLOPEWALLWALLCONCRETE DECKSURFACEGSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIONGSM EDGE FLASHINGSADDLE FLASHINGCONC.DECKSLOPEWALLWALL SEALANT TO OOZE OUT ANDBUTTERED AT JOINTWALLWALLCONC. DECK EDGE PERPENDICULAR TOWALLCONCRETE DECK EDGE PROTRUDING BEYONDEXTERIOR WALLCONCRETE DECK EDGE FLUSH WITHEXTERIOR WALL(NOT SHOWN IN DETAIL )1-SADDLE FLASHING ASSEMBLY (WALL FLASHING TO DECK EDGE METAL)POST FLASHINGNOT USEDDECK PLAN - SHEET FLOW1/16" GAP BETWEEN PLYWOOD &CONCRETENOTES: IMPERVIOUS SURFACE TO REMAIN A MINIMUM OF 2" BELOW THE PERIMETER WEEP SCREED. ROOF DECK DRAINAGE, INCLUDING SECONDARY DRAINS, SHALL COMPLY WITH CBC SECTION 1503 AND THE CALIFORNIA PLUMBING CODE.FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILSDECK DRAINNOTE: REFERENCE CON-DEK SPECIFICATIONS FOR PROPER LATH INSTALLATION.FOR ADDITIONAL REQUIREMENTS AND INFORMATION SEE DETAILSGS88 PIGMENTED SEALERCONCRETE DECK - SLOPED TO DRAIN4-16-2-1-SUBSTRATE <br />SLOPESUBSTRATESLOPE <br />SUBSTRATESLOPESUBSTRATE <br />SLOPE WALL8-FLASHINGGU80 TOPCOAT3/4" FIBERGLASS WITH PD RESIN (SCOATS)PRIMERDECK EDGEMETALWALL FLASHINGSADDLE FLASHINGDOOR PAN FLASHINGCONC. DECK <br />SLOPE20-20-11-8-SADDLE FLASHING20-POSTFLASHING15-GS88 PIGMENTED SEALERGU80 TOPCOAT3/4" FIBERGLASS WITH PD RESIN (SCOATS)PRIMERSECONDARY DRAIN +2" ABOVE MAINDRAIN6"4"8"4"4"4"6"4"4"4"10"ONE PIECE SOLDERED SADDLEFLASHINGPRE-MADE CORNER GSM EDGEFLASHINGGSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSION,EXTEND 1" PAST GSM "L" FLASHINGCEMCO # 66 EXPANDED FLANGECASING BEAD, APPLY O/ W.R.B.CONCRETE DECK SURFACEONE PIECE SOLDERED SADDLEFLASHINGPRE-MADE CORNER GSM EDGEFLASHINGGSM "L" FLASHINGCEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSION,EXTEND 1" PAST GSM "L" FLASHINGCEMCO # 66 EXPANDED FLANGECASING BEAD, APPLY O/ W.R.B.3 BEDS OF SEALANT 1" APARTCONCRETE DECK SURFACECONC.DECKSLOPECONC.DECKSLOPEWALLWALL WALLWALL 3 BEDS OF SEALANT 1" APART TORECEIVE "L" FLASHING3 BEDS OF SEALANT 1" APART TORECEIVE CORNER DECK EDGEFLASHING321456321456CONCRETE PATIO EDGE1ONE PIECE SOLDERED SADDLEFLASHING2GSM EDGE FLASHING3GSM "L" FLASHING4CEMCO #7 EXTENDED FOUNDATIONSCREED WITH 1-1/2" EXTENSIO,EXTEND 1" PAST GSM "L" FLASHING65CEMCO # 66 EXPANDED FLANGECASING BEAD. APPLY O/ W.R.B.3 BEDS OF SEALANT 1" APARTCONC.PATIOSLOPE6"4"4"4"4"CCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM ANo.Date DescriptionAD-41.1EXTERIORIMPERVIOUSSURFACE (CON-DEK)A06-21-23