My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
LDV. INC. 1 - 2005
Clerk
>
Contracts / Agreements
>
L
>
LDV. INC. 1 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 2:46:45 PM
Creation date
3/29/2005 2:43:24 PM
Metadata
Fields
Template:
Contracts
Company Name
LDV, Inc.
Contract #
A-2005-039
Agency
Police
Council Approval Date
2/22/2005
Expiration Date
12/31/2005
Insurance Exp Date
4/11/2006
Destruction Year
2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />LDVUiJj) <br /> <br />LDV, Inc. <br />180 Industrial Drive <br />Burlington, WI 53/05 <br />800.558.5986 <br />Fax 262.763.0156 <br />www.ldvuso.com <br /> <br />Section Qty <br /> <br />13.02! 1 <br />13.031 20 <br />13.04 6 <br />13.05 3 <br />13.06 2 <br />13.07 10 <br />13.08 7 <br />13.09 1 <br />13.10 1 <br />14.00 <br />14.01 8 <br />14.02 2 <br />1403 1 <br />14.04 6 <br />14.05 2 <br />14.06 <br />14.07 <br /> <br />2. Three (3) electronic converter/chargers, 80 amp minimum output each, installed underbody in <br />weather resistant aluminum compartment. Compartment shall have 2" box pan door with slam <br />latch, stainless rotary O-ring handle, CH545 key lock and gas charged lift/support cylinders. <br />Converter/charger features: <br />. Charges three banks of batteries at the same time. <br />. UL listed for safety. <br />. Manual reset circuit breaker. <br />. Reverse battery protection. <br />. Electronic current limiting. <br />. High voltage protection. <br />3. One (1) Cole Hersee master disconnect switch to control the auxiliary battery systems. <br />4. 12Vdc control panel with seven (7) UL listed magnetic/hydraulic circuit breakers with red LED <br />indicators, 12Vdc digital voltmeter, and 12Vdc low voltage alarm. <br />5. 12Vdc auxiliary panels with UL listed magnetic/hydraulic circuit breakers as required. <br />6. 12Vdc auxiliary digital voltmeter to monitor the communications battery system. <br />Roof mounted solar cell with charge controller interfaced to auxiliary battery bank. <br />Recessed halogen light fixture with stainless steel finish and frosted lens, includes 20W Xenon <br />halogen bulb. Located as shown on drawing. <br />Recessed halogen light fixture with stainless steel finish and frosted lens, includes 10W red Xenon <br />halogen bulb. Located as shown on drawing. <br />Dimmer for recessed halogen light fixture with switch and faceplate, 12 lights per switch max. <br />Arcon Universal, #18104 (or current model), utility light with switch, mounted above exterior <br />removable shelf. <br />Whelen 810 Series white quartz halogen scene light with 8-320 optics, model number 810CAOZR (or <br />. current model),located as shown on drawing. <br />15A-12Vdc power outlets mounted in stainless steel wall plate, located as shown on drawing. <br />. Whelen 295HFS2(or current model) remote siren amplifier with ffush mount control head. <br />Federal Signal TS-100 (or current model) 100 watt speaker behind grill. <br />!12VDC EMERGENCY LIGHTING: <br />! Whelen 508E Series linear strobe light with red or blue lens, model number 58EC20'U (or current <br />1 model). Located as shown on drawing (color - to be determined). <br />. Whelen 81 E Series linear strobe light with red or blue lens, model number 81EC20"U (or current <br />model). Located as shown on drawing (color - to be determined). <br />Whelen UPS12180 (or current model). twelve (12) outlet 180-watt power supply for strobe lights. <br />Whelen 810 Series dual halogen lights with red or blue lenses, model number 810CM"R (or current <br />model), located as shown on drawing. (colors - to be determined) <br />Whelen 810 Series dual halogen lights with lens colors other than red or blue. model number <br />810CAMR (or current model). (colors - to be determined) <br />Whelen AF6012 (or current model) flasher for halogen lights. <br />12VDC WIRING REQUIREMENTS: <br />1. 2-gauge minimum copper stranded battery cable shall be used for 12Vdc main supply lines. All <br />. cable runs shall be full length, no splices. All cable terminals shall be staked and soldered. All cable <br />shall be enclosed in convoluted polyethylene tubing and the ends of the cable shall be sealed with <br />color-coded shrink-wrap identifying the function of the cable. <br />2. All added electrical circuits shall be protected from over-current by resettable circuit breakers <br />appropriately rated for the load. Only circuit breakers shall be used in the installation of added <br />electrical wiring (plug type fuses are unacceptable). <br />.3. Circuit breaker functions shall be identified b en raved or rinted labels. <br /> <br />11 <br /> <br />Santa Ana Police Department (eA) MCC30LLC260-03.3 RZ.xls <br /> <br />1/28/2005 <br />
The URL can be used to link to this page
Your browser does not support the video tag.