My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SecSol
Clerk
>
Contracts / Agreements
>
INACTIVE CONTRACTS (Originals Destroyed)
>
S (INACTIVE)
>
SecSol
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/25/2024 2:27:40 PM
Creation date
6/23/2005 9:30:38 AM
Metadata
Fields
Template:
Contracts
Company Name
SecSol Inc, dba Security Solutions
Contract #
A-2005-113
Agency
Public Works
Council Approval Date
6/6/2005
Insurance Exp Date
3/20/2006
Destruction Year
2011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
135
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K. Use insulated spring wire nuts with plastic caps for copper conductor splices and <br />taps, 10 AWG and smaller. Ideal wingnuts or approved equal. Scotchlock type <br />wirenuts shall not be used. <br />3.3 INSTRUMENTATION CABLE INSTALLATION <br />A. Separate analog signals from power conductors and 110V control signals unless <br />otherwise noted. <br />B. Ground shield on shielded cables at one end only and as recommended by instrument <br />manufacturer. <br />C. Terminate stranded conductors with pre -insulated crimp type spade or ring type <br />terminals properly sized to fit fastening device and wire size. <br />D. Install and terminate vendor furnished cable in accordance with vendor equipment <br />requirements. <br />3.4 INTERFACE WITH OTHER PRODUCTS <br />A. Identify wire and cable under provisions of Section 16195. <br />B. Identify each conductor with its circuit number or other designation indicated on the <br />Drawings. <br />3.5 FIELD QUALITY CONTROL <br />A. Perform field inspections and testing under provisions of Section 01660. <br />B. Inspect wire and cable for physical damage and proper connections. <br />C. Measure tightness of bolted connections and compare torque measurements with <br />manufacturer's recommendations. <br />D. Test shielded instrumentation cable shields with an ohmmeter for continuity along the <br />full length of the cable and for shield continuity to ground. <br />E. Connect shielded instrumentation cables to a calibrated 3-20 milliamp DC signal <br />transmitter and receiver. Test at 4, 12, and 20 milliamp transmitter settings. <br />3.6 OWNERS CONDUCTOR COLOR CODE REQUIREMENTS <br />A. CONTRACTOR shall follow the following color code requirements for conductors. On <br />3-phase circuits, conductor insulation color shall be as shown. Wire and cable shall <br />be factory color -coded by integral pigmentation with a separate color for each phase <br />and neutral. On conductors larger than No.8 AWG, color tape or colored plastic <br />bands will be permitted. <br />ApplicationConductors Color <br />City of Santa Ana Wire and Cable <br />Security Management System Project Page 16123-4 <br />SantaAna_SMS_16123 <br />
The URL can be used to link to this page
Your browser does not support the video tag.