My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SECURITY SOLUTIONS, INC. 2
Clerk
>
Contracts / Agreements
>
INACTIVE CONTRACTS (Originals Destroyed)
>
S (INACTIVE)
>
SECURITY SOLUTIONS, INC. 2
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/15/2015 2:56:34 PM
Creation date
12/19/2006 5:24:38 PM
Metadata
Fields
Template:
Contracts
Company Name
SECURITY SOLUTIONS, INC.
Contract #
A-2006-278
Agency
PUBLIC WORKS
Council Approval Date
10/16/2006
Insurance Exp Date
3/20/2007
Destruction Year
2011
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1.6 PROJECT RECORD DOCUMENTS <br />A. Submit under provisions of Section 01300 and 01700. <br />B. -- Accurately record actual routing of all underground conduits. -- -- -- — - - <br />1.7 REGULATORY REQUIREMENTS <br />A. Conform to requirements of ANSI /NFPA 70. <br />B. Furnish products listed and classified by Underwriters Laboratories, Inc. As suitable <br />for purpose specified and shown. <br />1.8 PROJECT CONDITIONS <br />A. Verify that field measurements are as shown on drawings. <br />B. Verify routing and termination locations of conduit prior to rough -in. <br />C. Conduit routing is shown on Drawings in approximate locations unless dimensioned. <br />Route as required to best suit field conditions. <br />PART2 — PRODUCTS <br />2.1 CONDUIT REQUIREMENTS <br />A. Minimum Size: 3/4 inch unless otherwise specified. <br />B. Underground Installations: Use nonmetallic conduit. Risers shall be PVC coated <br />galvanized steel conduit. <br />1. Minimum Size: 1 inch. <br />C. The conduit type used shall be in conformance with Part 3 herein and the area <br />designation as defined in Section 16010. <br />2.2 METAL CONDUIT <br />A. Rigid Galvanized Steel Conduit (RGS): ANSI C80.1. <br />B. Fittings and Conduit Bodies: ANSI /NEMA FB 1; Crouse Hinds or approved equal. <br />All bodies shall be cast feralloy and of full body design. Elbows and pulling ell's are <br />not to be used. <br />C. Rigid steel conduit shall be manufactured by Triangle PWC, Republic Steel, or <br />approved equal. <br />2.3 PVC COATED RIGID GALVANIZED STEEL METAL CONDUIT <br />City of Santa Ana "' - -- <br />Security Management System Project Page 16111 -2 <br />SantaAna_SMS_16111 <br />
The URL can be used to link to this page
Your browser does not support the video tag.