D. NEMA 250 - Enclosures for Electrical Equipment (1000 Volts Maximum). <br />E. NFPA 70 - National Electrical Code. <br />PART 2 — PRODUCTS <br />2.1 CAMERAS <br />A. The system shall accommodate any combination of Manual Zoom and Pan Tilt Zoom <br />Cameras. <br />B. All Cameras shall be IP addressable, incorporate a web server and produce motion <br />JPEG images. <br />C. All Cameras shall operate from 110/120 VAC power. <br />D. Manual Zoom Cameras: Manual Zoom Camera shall be an industrial grade color <br />video camera with a rugged weatherproof enclosure. Camera shall be supplied for <br />low light capability, with automatic focus and exposure, precise and fast in varying <br />light and focal distances. Camera shall be supplied with mounting arm. Manual <br />Zoom Cameras shall meet the following specifications: <br />1. Camera Specifications <br />a. Standard Lens Vari -focal 6mm -12mm <br />b. <br />Standard Field of View <br />25 deg. to 48 deg. <br />c. <br />Sensor <br />1/3" color Exview HAD CCD <br />d. <br />Shutter <br />1/60 to 11100,000 sec <br />e. <br />Sensitivity <br />0.1 Lux (f1.2) <br />f. <br />Frame Rate <br />30fps (352x240), 10fps (704X480) <br />g. <br />Resolution <br />352x240 and 704x480 <br />h. <br />White Balance <br />Auto <br />i. <br />Gain <br />Auto <br />j. <br />Iris <br />Auto <br />k. <br />Protocol <br />TCP /IP <br />I. <br />Auxiliary output <br />NTSC Video <br />m. <br />Minimum # of Inputs <br />One <br />n. <br />Ambient Temperature <br />-14 deg to 122 deg F <br />o. <br />Heater and Blower <br />Thermostatically Controlled <br />2. Enclosure Specifications <br />a. Rugged weatherproof enclosure for indoor or outdoor use <br />b. Die cast and extruded aluminum construction <br />c. Easy access for servicing and installation <br />d. Cable entry glands and mounting holes on bottom of enclosure <br />e. Built in automatic heater <br />See Table 2.1 for required cameras. The Manual Zoom Cameras shall be IV &C No. <br />MZ- 3130 -LL or approved equal. <br />City of Santa Ana Security Management System Specific Requirements <br />Security Management System Project Page 17100 -2 <br />SantaAna_SMS_17100 <br />