My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75C - PH CONSTRUCTION CODES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2007
>
11/05/2007
>
75C - PH CONSTRUCTION CODES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 4:36:59 PM
Creation date
10/31/2007 10:53:19 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
75C
Date
11/5/2007
Destruction Year
2012
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1-9~~1-~1-v r7u~F'Fi~-n ~~ ~~i ~~ n+~fv[7~iT •~• i n n n r~ <br />nnmr~nnon4e ~h~~ rcc~ic~~ ooi~min fnrno~ ~h~ll nnnfnrm fn Oho rorr~ ~iromen4c. of <br />~`~4inn '177 ovnon4 ~c~ mnrlifior! by 4hi~+ con~inn <br />rr.T-~--rvr~cicvcp~c-cru-i~-rvar~cv--rte rZrnv~cvavrr. <br />19~.1~3 ~~?FSf~1+6z8~~ ~, ''~ °nrl ~, d+rrci6'tttrai nl~in nnnnrCtV~ie~ve~c "r° <br />eet-pe~rrtfa~il~ing~s I~aie~;Tr-Sei~rr~i6~or~i, ^^^' <br /> <br />SECTION 15: That section 8-150 of the Santa Ana Municipal Code is hereby <br />amended to read as follows (new language underlined, deleted language in strikeout for tracking <br />purposes only): <br />Sec. 8-150. Fire protection requirements (Volume 24, Section 3403.1348-~). <br />The first paragraph of Section 3403.1 of X493-~ the building code is amended by <br />adding thereto the following: <br />EXCEPTION: If additions, alterations or repairs made to any building <br />constructed prior to January 1, 1946, other than an R-occupancy building, <br />exceed fifty thousand dollars ($50,000.00) in cost in any one-year period, then <br />either (A) the entire building must be completely sprinklered in accordance with <br />fire department standards, or (B) the building must comply with all the following <br />requirements: <br />The ceiling of a roof system shall be of one-hour construction, and <br />all ceiling or wall penetrations shall have approved fire dampers. <br />2. All stairways shall be completely enclosed with one-hour <br />construction to exits; and enclosed stairways or required exits shall <br />lead directly to the outside of the building. <br />Ordinance No. NS-XXXX <br />Page 13 of 48 <br />75C-21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.