<br />the building or be protected. Such required hydrant or hydrants may be <br />located either on a public street or on the site of the premises to be <br />protected. <br /> <br />2. In all other cases: the required hydrant or hydrants shall be located on the <br />site of the premises to be protected, except that any required hydrant may <br />be located on a public street if such location is within one hundred fifty <br />(150) feet of all portions of the exterior walls of the building to be <br />protected. <br /> <br />Where more than one (1) fire hydrant is located on the site of the premises to be <br />protected, or where a combination of hydrants located on such site and a public street <br />are used to meet the distance requirements, the required fire flow in gallons per minute <br />may be divided between such hydrants provided: <br /> <br />1. That the combination of hydrants will deliver the required flow, and <br /> <br />2. That no single hydrant has a flow of less than one thousand five hundred <br />(1,500) gallons per minute with a residual pressure measured at the <br />hydrant outlet of not less than twenty (20) pounds per square inch during <br />times of average daily consumption. <br /> <br />Water supply may consist of reservoirs, pressure tanks, elevated tanks, water mains, or <br />other fixed system capable of supplying the required fire flow, subject to the approval of <br />the fire marshal. The precise location, number and type of fire hydrants connected to a <br />water supply to be provided in accordance with this subsection shall be subject to the <br />approval of the fire marshal. All hydrants shall be accessible to the fire department <br />apparatus by roadways meeting the requirements of Section 503. <br /> <br />No use of an existing building, or any portion thereof, for either a place of assemblage <br />or a Group H occupancy, as defined in subsections 903.2.1 and 903.2.4, shall be <br />initiated or expanded unless the building as a whole will comply with the requirements of <br />this subsection 508.1 such as would apply to the new construction of such building for <br />the same uses. <br /> <br />For purposes of this section, an existing building or structure shall be deemed to have a <br />value equal to the current cost of construction of a building or structure of the same size <br />and type of construction. In determining such value, the fire marshal shall be guided by <br />the most recent building valuation data published by the International Conference of <br />Building Officials. <br /> <br />In determining the fire flow requirements for any building, structure, or fire area, the fire <br />marshal shall proceed in accordance with the standards set forth in that certain "Santa <br />Ana Fire Department Guide for Determination of Fire Flows," of which not less than one <br />(1) copy is on file in the office of the clerk of the council of the City of Santa Ana. <br /> <br />(b) Subsection 508.3 of the California Fire Code is amended to read as follows: <br /> <br />Ordinance No. NS-2760 <br />Page 30 of 36 <br />
The URL can be used to link to this page
Your browser does not support the video tag.