Laserfiche WebLink
- - - <br />24" FRAME - AND -COVE-R I - <br />SAMPLING <br />(BOLT DOWN) (TYP) I I I MANHOLE BOX <br />I I ` CLEANOUT <br />6" INLET -( <br />6" INLET <br />FLOW <br />I II I II II <br />L_______J L_---J 6"OUTLETJ <br />PLAN VIEW <br />STANDARD TOP BLOCKS REQUIRED <br />AT EACH MANHOLE COVER <br />//- SAMPLING MANHOLE/BO <br />\ 24"CAST IRON FRAME AN / <br />AND COVER (BOLT DOWN) <br />CLEANOUT <br />6" OUTLET <br />SECTION VIEW <br />6" OUTLET <br />PRECAST INTERCEPTOR PER <br />APPROVED MATERIAL LIST <br />NOTES: <br />1. MANHOLE LID ACCESS OVER EACH BAFFLE TUBE. <br />2. INTERCEPTOR LOCATED IN AN AREA SUBJECT TO TRAFFIC MUST BE HS-20 TRAFFIC RATED. <br />3. ALTERNATIVE MATERIALS ACCEPTABLE: HDPE OR FIBERGLASS (CAST IRON PIPE IS PROHIBITED) <br />4. INTERCEPTOR MUST HAVE IAPMO APPROVAL. <br />5. OUTLET SHALL BE SAME DIAMETER AS INLET. <br />6. INTERIOR OF INTERCEPTOR, INCLUDING ROOF, SHALL BE COATED WITH A PROTECTIVE COATING. <br />DATE: I( a 2-°'-IO CITY OF SANTA ANA o <br />PUBLIC WORKS AGENCY <br />DATE REVISION STD. PLAN <br />I)2020 R.R. NEW NUMBER <br />GRAVITY GREASE INTERCEPTOR 1210 <br />