My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 07 - Sewer System Management Plan 2025 Update
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2025
>
10/21/2025 Regular
>
Item 07 - Sewer System Management Plan 2025 Update
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/15/2025 8:52:12 AM
Creation date
10/15/2025 8:43:39 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
07
Date
10/21/2025
Destruction Year
P
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF SANTA ANA <br />APPENDIX I <br />PROJECT NO.: XX-XXXX <br />PROJECT TITLE <br />The Contractor shall submit all material information for sewer lateral cleanout connections <br />and appurtenances prior to commencing work. The Engineer shall review and upon <br />approval notify the Contractor by a memorandum. Non -approved materials shall not be <br />used. <br />New submittals shall be required for material substitutions. The Engineer shall review and <br />upon approval notify the Contractor by a memorandum. <br />All fittings shall be pressure rated and classified the same as adjoining pipe. The inside <br />diameter shall match inside diameter of adjoining pipe and shall be designed for pipe <br />bursting or pipe jacking applications. <br />Metal in saddles, clamps and appurtenances shall be 302 or 304 stainless steel following <br />ASTM A240. <br />Elastomeric materials, gaskets, clamps and connectors shall be oil resistant and <br />manufactured following ASTM F477. <br />The Contractor shall submit certification by the manufacturer of the pipe bursting system <br />to have successfully completed training in operating the bursting head, installing proposed <br />replacement pipe and operation and maintenance of all equipment to be used. <br />The Contractor shall submit certification by the manufacturer of the fusing equipment <br />having successfully completed training in handling replacement of pipe materials, butt - <br />fusion of pipe joints and saddle fusion of fittings for service laterals, and operation and <br />maintenance of all equipment to be used. The Certificate of Training includes at a <br />minimum: Installer's name, date of issuance and process or product the person/s is/are <br />certified to install. These certifications of training and operation of pipe bursting system <br />shall be submitted prior to commencing pipe bursting work. <br />The curb and gutter shall be protected in place. If the Contractor damages curb, gutter, it <br />shall be removed and replaced to match existing in accordance with City of Santa Ana <br />Standard Plan No. 1101. This work shall also include removal and replacement of PCC <br />sidewalk, driveway panels and landscaping to facilitate construction of sewer laterals. PCC <br />sidewalk and driveway approach panels shall be replaced to match existing in accordance <br />with City of Santa Ana Standard Plan Nos. 1104 and 1112. Sidewalk replacement shall be <br />from score line to score line, unless the sidewalk panels exceed four feet in length. At no <br />time, shall a sidewalk panel floater be less than four feet from the nearest score line. <br />Landscaping shall be replaced in -kind. <br />6.16 CONSTRUCT 4" OR 6" POLYVINYL CHLORIDE (PVC) SEWER LATERALS AND <br />CLEANOUTS (OPEN TRENCH) <br />PVC sewer pipe shall be as manufactured by JM EAGLE or approved equivalent. <br />PVC gravity sewer pipe and fittings shall conform to ASTM D3034 for diameters from 4" <br />- 15", and ASTM F679 for 18" - 24", with integral bell gasket joints. Rubber gaskets shall <br />be factory installed and conform to ASTM F477. <br />
The URL can be used to link to this page
Your browser does not support the video tag.