My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Packet 11.10.25
Clerk
>
Agenda Packets / Staff Reports
>
Planning Commission (2002-Present)
>
2025
>
Packet 11.10.25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/16/2025 9:45:45 AM
Creation date
12/16/2025 9:43:41 AM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3611 S Harbor Blvd • Santa Ana • CA 92704 <br /> <br />Checked By: <br />Drawn By: <br />Project Architect: <br />Job Number: <br />Scale: <br />All designs, ideas arrangements and plans indicated by these <br />drawings and specification are the property and copyright of the <br />architect and shall neither be used on any other work or be <br />disclosed to any other person for any use whatsoever without <br />written permission from Mark J. Paone, AIA. <br />25-12 <br />RC, TL, MP, GN <br />MP, TL <br />58 PLAZA SQUARE, SUITE F, ORANGE, CA. 92866 (714) 633-7667 <br />TL <br /> <br />Planning <br />Site Plan <br />G2.1 <br />MJP <br />Architecture • Design • Planning <br />aia,Inc <br />Delta No. <br />Initial Submittal:April 7, 2025 <br /> <br />(Owner Logo) <br />SOCO Harbor Inc. Site <br />Plot Date:Thu, Sep 11, 2025 <br />None <br />CUP Submittal:September 11, 2025 <br />N88º40'15"E 84.42' <br />N71º18' <br />5 <br />9 <br />"W <br />358.4 <br />2 <br />'N37º47'13"E53.24'N01º23'04"W370.19'N88º35'56"E 666.94'N01º19'45"W488.01'2 <br />10 <br />4 7 <br />7 <br />3 <br />8 <br />2 <br />23 <br />62 <br />18 <br />8 <br />67 <br />10 <br />2 <br />14 <br />13 <br />1310 <br />10 <br />2 <br />2 <br />16 <br />29 <br />29 <br />16 <br />10 <br />51 <br />292927 <br />22 <br />11 <br />4 <br />2 <br />5 <br />11 <br />OVERALL SITE PLAN <br />Scale: 1" = 30'-0"1 <br />N O R T HHARBOR BOULEVARDEXISTING PROPERTY LINE <br />LAKE CENTER DRIVE <br />3621 <br />3631 <br />CRISTO REY HS <br />3611 <br />120' WIDE PUBLIC RIGHT OF WAY60' WIDE PUBLIC RIGHT OF WAY <br />2 STORY BUILDING <br />24,769 SF <br />32' HIGH <br />2 STORY BUILDING <br />45,774 SF <br />36' HIGH <br />NEW (6) BIN <br />TRASH <br />ENCLOSURE <br />(4) 4CY - <br />TRASH AND <br />RECYCLE + <br />(2) 2CY - <br />FOOD <br />WASTE <br />EXISTING BIKE <br />RACK <br />LANDSCAPING <br />LANDSCAPING <br />LANDSCAPING <br /> NEW COVERED <br />OUTDOOR DINING <br />EXISTING <br />TRANSFORMER <br />EXISTING TRAFFIC <br />LIGHT <br />DROP-OFF <br />DROP <br />- <br />O <br />F <br />F <br />FH <br />FH <br />FH <br />FH <br />FH <br />FH <br />EXISTING <br />BACKFLOW <br />PREVENTER <br />EXISTING <br />TRANSFORMER <br />EXISTING <br />TRANSFORMER <br />60'-0" <br />124'-9" <br />99'-6" <br />86'-6" <br />79'-2" <br />69'-6" <br />29'-9" <br />30'-0" <br />EXISTING TRASH <br />ENCLOSURE <br />EXISTING TRASH <br />ENCLOSURE <br />ARTIFICIAL TURF <br />NEW 6' HIGH <br />METAL FENCE, <br />TYPICAL <br />EXISTING <br />COURTYARD <br />2 STORY BUILDING <br />CRISTO REY HS <br />3601 <br />SECOND FLOOR <br />OF 2 STORY BUILDING <br />98'-10" <br />EXISTING 6' HIGH CMU WALL <br />FINISHED WITH PAINTED <br />CEMENT PLASTER <br />EXISTING <br />TRAFFIC <br />LIGHT <br />140'-0" <br />NEW GATE AT <br />PROPERTY LINE <br />NEW 5' WIDE ACCESS PATH WITH <br />GATE AT PROPERTY LINE <br />16' WIDE <br />GATE WITH <br />FIRE <br />DEPARTMENT <br />KNOX BOX <br />SECOND <br />FLOOR <br />ABOVE <br />SECOND <br />FLOOR <br />ABOVE <br />INFILL AT <br />FIRST FLOOR <br />INFILL AT FIRST <br />FLOOR <br />23'-0" <br />23'-0" <br />8'-0" <br />5'-0" <br />NEW <br />CONCRETE <br />SIDEWALK <br />TRAFFIC CONES <br />TO BE PLACED <br />BEFORE <br />SCHOOL START <br />AND BEFORE <br />SCHOOL END, <br />TYPICAL <br />23'-0" <br />EXISTING PUBLIC BUS STOP <br />NEW (2) BIN <br />TRASH <br />ENCLOSURE <br />(1) EACH 4CY <br />- TRASH AND <br />RECYCLE <br />NEW SIGN <br />STATING <br />"SCHOOL <br />DROP-OFF <br />(WITH RIGHT <br />ARROW) AND <br />OFFICE PARKING <br />(WITH LEFT <br />ARROW)" <br />NEW SIGN <br />STATING <br />"SCHOOL <br />DROP-OFF <br />(WITH RIGHT <br />ARROW) AND <br />OFFICE PARKING <br />(WITH LEFT <br />ARROW)" <br />NEW <br />ACCESSIBLE <br />CURB CUT <br />RAMPS <br />NEW SIGN <br />STATING "WAIT <br />HERE BEFORE <br />PROCEEDING <br />TO STUDENT <br />LOADING" <br />NEW SIGN <br />STATING <br />"STUDENT <br />DROP-OFF <br />AND PICK-UP <br />AREA" <br />NEW SIGN <br />STATING <br />"SCHOOL EXIT" <br />SITE PLAN SYMBOLSBUILDING IN SCOPEBUILDING NOT IN SCOPE <br />ACCESSIBLE PATH OF TRAVEL TO RIGHT OF WAY <br />NEW CONCRETE SIDEWALK <br />PROJECT DATA <br />TOTAL LOT SIZE: <br />SQUARE FOOTAGE: <br />SPRINKLERS: <br />PROPOSED USE: <br />OCCUPANCY TYPE: <br />MATERIALS: <br />LEGAL DESCRIPTION: <br />GENERAL PLAN USE: <br />CONSTRUCTION TYPE: <br />ASSESSORS PARCEL NUMBER: <br />APPLICANT CONTACT: <br />ADDRESS: <br />8.96 ACRES, 433,856.6 SF <br />3601 <br />OFFICE USE 1ST FLOOR; SCHOOL USE 2ND FLOOR <br />ORIGINALLY APPROVED SQUARE FOOTAGE = 36,362 SF <br />3611 <br />SCHOOL USE <br />ORIGINALLY APPROVED SQUARE FOOTAGE = 45,774 SF <br />ENCLOSED OVERHANGS SQUARE FOOTAGE = 1,183 SF <br />3621 <br />OFFICE USE <br />ORIGINALLY APPROVED SQUARE FOOTAGE = 45,774 SF <br />3631 <br />OFFICE USE <br />ORIGINALLY APPROVED SQUARE FOOTAGE = 24,769 SF <br />TOTAL = 153,862 SF <br />ALL EXISTING BUILDINGS ARE FULLY SPRINKLERED <br />OFFICE USE and EDUCATION USE <br />3601 - B, E <br />3611 - E <br />3621 - B <br />3631 - B <br />EXTERIOR WALL MATERIAL: <br />EXISTING PAINTED TILT-UP CONCRETE WITH SPRAY TEXTURE <br />FLOOR AND ROOF - CONCRETE OVER METAL DECK SUPPORTED BY <br />STEEL BAR-JOIST <br />(NO WOOD CONSTRUCTION EXISTS IN THESE BUILDINGS) <br />ROOF MATERIAL: <br />SINGLE PLY PVC <br />PARCEL 3 FMB 198, P1-3 <br />P - PROFESSIONAL DISTRICT <br />IIB (RECLASSIFIED) <br />414-261-07 <br />STEPHEN HOLTE <br />OFFICE: (714) 439-9626 Ext. 901 <br />CELL: (733) 426-2815 <br />email: sholte@cristoreyoc.org <br />3611 S HARBOR BLVD <br />SANTA ANA, CA 92704 <br />SITE PARKING CALCULATION <br />TOTAL REQUIRED: 489 <br />OFFICE USE: <br />MEDICAL USE: <br />EDUCATION USE: <br />3631 BUILDING (B OCCUPANCY) 24,769 SF @3/1000 = 75 CARS <br />3621 BUILDING (B OCCUPANCY) 45,774 SF @3/1000 = 138 CARS <br />3601 BUILDING (1ST FLOOR) 17,725 SF @5/1000 = 89 CARS <br />3601 BUILDING (2ND FLOOR) <br />CLASSROOMS: 2,796 SF @1/150 = 19 CARS <br />OFFICE: 9,333 SF @1/333 = 28 CARS <br />3611 BUILDING <br />CLASSROOMS: 17,488 SF @1/150 = 116 CARS <br />OFFICE: 7,829 SF @1/333 = 24 CARS <br />NOTES <br />1. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br />8. <br />9. <br />10. <br />ALL IMPROVEMENT AS SHOWN HEREON TO BE CONSTRUCTED AND INSTALLED BY THE DEVELOPER <br />AND/OR THE DEVELOPER EXPENSE IN ACCORDANCE WITH THE CITY DESIGN STANDARDS AND <br />SPECIFICATIONS, THE SANTA ANA MUNICIPAL CODE, AND THE APPROVED STREET IMPROVEMENT <br />PLANS. <br />EXISTING EASEMENTS TO BE COORDINATED WITH EDISON, RELOCATED OR VACATED. <br />APPROPRIATE PRIVATE BACKFLOW PREVENTION DEVICE REQUIRED FOR ALL FIRE SERVICE, <br />DOMESTIC AND LANDSCAPE WATER METER PER GRADING AND STREET IMPROVEMENT PLANS. <br />ABOVE GROUND WATER SYSTEM APPURTENANCES SUCH AS FIRE HYDRANTS, BACKFLOW <br />PREVENTION DEVICES, FIRE CONNECTION STANDPIPES AND ABOVE GROUND METERS SHALL BE <br />PAINTED AS FOLLOWS: <br />a. Public fire hydrants - WHITE <br />b. Private fire appurtenances - RED <br />c. Irrigation appurtenances - GREEN <br />d. Domestic appurtenances - BLUE <br />PROJECT TO COMPLY WITH SAMC SEC. 16-33. <br />A MINIMUM 40'X16' WIDE TRASH STAGING AREA WILL BE REMOVED. <br />MINIMUM VERTICAL CLEARANCE AT TRASH STAGING AREA TO BE 25'. <br />MAXIMUM SIZE OF TRASH BIN: 4 CUBIC YARDS <br />ALL DRIVEWAYS AND STAGING AREAS WILL BE ABLE TO SUSTAIN A MINIMUM GROSS WEIGHT OF <br />60,000 LBS PER VEHICLE <br />SEE SHEET C-7 PRELIMINARY STREET IMPROVEMENT PLAN FOR THE PUBLIC IMPROVEMENTS TO BE <br />CONSTRUCTED FOR THIS PROJECT. THE STREET IMPROVEMENT PLAN WILL BE SUBMITTED TO THE <br />PUBLIC WORKS AGENCY FOR FORMAL REVIEW AFTER SITE PLAN APPROVAL. <br />PARKING REQUIRED <br />EXISTING STANDARD STALLS: <br />EXISTING ACCESSIBLE STALLS: <br />TOTAL STALLS PROVIDED: <br /> <br />STANDARD PARKING STALLS REQUIRED: <br />ACCESSIBLE STALLS REQUIRED: <br />TOTAL REQUIRED STALLS: <br />477 <br />12 <br />489 <br /> <br />480 <br />9 <br />489 <br />APPLICABLE CODES <br />1. Project shall conmply with the current State of California building codes adopted by the City of Santa Ana at <br />the time of permit application submittal. As of this writing, the applicable codes include the following: <br />a. 2022 California Building Code (CBC) <br />b. 2022 California Residential Code (CRC) <br />c. 2022 California Mechanical Code (CMC) <br />d. 2022 California Plumbing Code (CPC) <br />e. 2022 California Electrical Code <br />f. 2022 California Energy Code <br />g. 2022 California Green Building Standards Code (AL Green) <br />h. Santa Ana Municipal Code (SAMC) <br />Compliance with all applicable state and local codes shall be required prior to the issuance of building <br />permits. <br />VEHICULAR DROP-OFF PATH <br />
The URL can be used to link to this page
Your browser does not support the video tag.