Item 29 - Public Hearing for the Second Reading and Adoption of Ordinance No. NS-3088 California Building Standards Code
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2026
>
01/20/2026
>
Item 29 - Public Hearing for the Second Reading and Adoption of Ordinance No. NS-3088 California Building Standards Code
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2026 2:51:36 PM
Creation date
1/14/2026 9:45:20 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
29
Date
1/20/2026
Destruction Year
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ii. Constructed of wood, and <br />iii. Do not have subterranean storage or parking, and <br />iv. Are not built integral to an above ground multi -story <br />Parking structure. <br />Should a structure that is three stories or less and 50,000 square feet or smaller on <br />anV single storV include subterranean storage or parking, then this ordinance shall <br />apply only to the subterranean areas. <br />2. In facilities where emergency responder radio coverage is required and <br />such systems, components or equipment required could have a <br />negative impact on the normal operations of the facility, the fire code <br />official shall have the authority to accept an automatically activated <br />emergency radio coverage system. <br />Sec. 14-21 Chapter 9 Fire Protection and Life Safety Systems - amendments <br />Chapter 9 FIRE PROTECTION AND LIFE SAFETY SYSTEMS is adopted in its entirety as <br />amended by the SFM with the following amendments: <br />Section 903.2 Where required is hereby revised as follows: <br />903.2 Where required. Approved automatic sprinkler systems in buildings and structures shall be <br />provided when one of the following conditions exists: <br />1. New buildings: Notwithstanding any applicable provisions of Sections <br />903.2.1 through 903.2.21, an automatic sprinkler system shall also be <br />installed in all occupancies when the total building area exceeds 5,000 <br />square feet as defined in Section 202, regardless of fire areas or allowable <br />area, or is more than two stories in height. <br />Exception: Subiect to approval by the Fire Code Official, open parking garages in <br />accordance with Section 406.5 of the California Building Code that are smaller than the <br />area specified in section 903.2.10 Q) or 903.2.10.1 of the California Fire Code. <br />2. Existin_a Buildings: Notwithstanding any applicable provisions of this <br />code, an automatic sprinkler system shall be provided in an existing <br />building when an addition occurs and one of the following conditions <br />exists: <br />2.1. When an addition is 33% or more of the existing building area, and <br />the resulting building area exceeds 5000 square feet. <br />2.2. When an addition exceeds 2000 square feet, and the resulting <br />building area exceeds 5000 square feet. <br />2.3. An additional story is added above the second floor regardless of fire <br />areas or allowable area. <br />Exception: Additions to Group R-3 occupancies shall comply with Section 903.2.8. <br />Section 903.3.5.3 Hydraulically calculated systems is hereby added as follows: <br />Ordinance No. NS-XXX <br />Page 17 of 26 <br />