My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 18 - Appeal Application of Conditional Use Permit to Allow the Expansion of a Private School
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2026
>
02/03/2026
>
Item 18 - Appeal Application of Conditional Use Permit to Allow the Expansion of a Private School
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/28/2026 10:11:01 AM
Creation date
1/28/2026 10:09:39 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
18
Date
2/3/2026
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
188
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLASSROOMCLASSROOMGIRLSRESTROOMBOYSRESTROOMELEV.DN.LABORATORYCLASSROOMCLASSROOMSKYLIGHTABOVEDN.14 <br />100% <br />49 <br />50%4950%EXITEXITDISTANCE BETWEEN EXITS = 34'-10"DI <br />A <br />G <br />O <br />N <br />A <br />L <br /> <br />D <br />I <br />M <br />E <br />N <br />S <br />I <br />O <br />N <br /> <br />= <br /> <br />8 <br />7 <br />' <br />- <br />2 <br />"LOBBYCLASSROOMUPELEV.RESTROOMSTORAGEUPEXIT49 <br />65%EXIT26 <br />35%DIAGONAL DIMENSION = 50'-0"DISTANCE BETWEEN EXITS = 20'-4"C O D E R E V I E WL E G E N DK E Y N O T E S - C O D E P L A NProject Name:Forty Martyrs Armenian Church Middle SchoolSite ExansionProject Address:5311 W. McFadden Ave. Santa Ana, CA 92704Parcel ID:Occupancy Group(s):Educational (Classroom Area) Laboratory (Educational)Construction:Type V-B (sprinkled)ALLOWABLEACTUALBuilding Height / Stories (Table 504.3 and 504.4): 35' / 132'-6" / 1Allowable Building Area (Table 506.2):E (S1) 38,000 sfAllowable Building Area Calculation (CBC Sec. 506.2.4): (E) Church First Floor = 4,950 s.f. (26%) x 24,000 = 6,240 s.f. (E) School First Floor = 12,700 s.f. (68%) x 38,000 = 25,840 s.f. (N) School First Floor = 1,154 s.f. (6%) x 38,000 = 2,280 s.f. Total Allowable Building Area = 34,360 s.f.Allowable square footage for two existing buildings and one proposed buildingfall under the maximum allowable square footage for the site, therefore noassumed property lines are required.Actual Building Area:First Floor: 1,154sfSecond Floor:3,692Total Building Area:4,846sfOccupant Load:Occupancy Type (From CBC Table 1004.5) AREA / FACTOROCC. LOADEducational [1st 503 (26) and 2nd Floor 1693 (85)]2196 / 20110Laboratory - Educational (Second Floor)692 / 5014Total124Egress Elements:REQUIREDPROVIDEDMin. Number of Exits For Occupant Load (CBC 1006.3.1):22Exit Doorway Arrangement - First Floor (CBC Sec. 1007.1.1 exception 2):13 Diagonal Dimension (50'-0"):16'-8" min.20'-4"Exit Doorway Arrangement - Second Floor (CBC Sec. 1007.1.1 exception 2): 13 Diagonal Dimension (87'-2"):29'-0" min.34'-10"Fire Resistance Rating Requirements for Building Elements (CBC Table 601, Type V-B)Structural Frame0 (hours)Bearing Walls - Exterior0Bearing Walls - Interior0Non-bearing Walls - Exterior0 (CBC Table 602, Type V-B, 10 ft. < x)Non-bearing Walls - Interior0Floor Construction0Roof Construction0Interior Wall and Ceiling Finish Requirements (CBC Table 803.11)Exit enclosures andRooms andGroupexit passagewaysCorridorsenclosed spacesE (Sprinklered)BCCPlumbing Fixture Calculations :Occupancy Load Factor (From Above): 124Men's (50%)62Women's (50%)62Fixture Requirements (CBC Table 2902.1):Water ClosetsUrinalsLavatoriesMen'sWomen'sMen'sWomen'sEducational1/ 501/501/1001/501/50Fixtures Required22122Fixtures Provided2*323* 2* First Floor water closet and lavatory added to Men's countDRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS, AND ARRANGEMENTSREPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OFTHE ARCHITECT. NO PART THEREOF SHALL BE REPRODUCED,COPIED, ADAPTED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED ORUSED WITHOUT PRIOR WRITTEN CONSENT OF AND APPROPRIATECOMPENSATION TO THE ARCHITECT. VISUAL CONTACT WITH THEABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTECONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS.DEV. PROJECT REV. RESUBMITTALPLAN CHECK SUBMITTALDEVELOPMENT PROJECT REVIEWISSUED FOR BIDIssuanceDateDescriptionRevisionDate No. DescriptionISSUED FOR CONSTRUCTIONStamp and SignaturePhone 714.560.9210www.jgartner.comSheet TitleProject No.:Sheet No.:Print Date:ARCHITECTUREPLANNING / INTERIORSPROJECT MANAGEMENTArchitectProject Name and LocationConsultantsF O R T Y M A R T Y R S A R M E N I A N <br />C H U R C H M I D D L E S C H O O L <br />S I T E E X P A N S I O N <br />53 11 WEST MCFAD DEN AVENU E <br />S A N T A A N A , C A 9 2 7 0 410 June 2025F I R S T F L O O R P L A N - C O D E R E V I E WSCALE: NTSLEGENDKEYNOTESCODE REVIEWCODE PLANTS-2S E C O N D F L O O R P L A N - C O D E R E V I E WSCALE: NTSExhibit 5 - Architectural Plan Set
The URL can be used to link to this page
Your browser does not support the video tag.