My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-3088 - Building and Fire Codes
Clerk
>
Ordinances
>
2021 - 2030 (NS-3001 - NS-XXXX)
>
2025 (NS-3074 -NS-XXXX)
>
NS-3088 - Building and Fire Codes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2026 9:28:24 AM
Creation date
1/28/2026 12:39:30 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Agency
Community Development
Item #
29
Date
1/20/2026
Destruction Year
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NFPA 24, 2025 Edition, Standard for the Installation of Private Fire Service Mains and Their <br /> Appurtenances is hereby amended as follows: <br /> Section 6.2.8.1 is hereby added as follows: <br /> 6 2 8 1 All indicating valves controlling fire suppression water supplies shall be_painted <br /> OSHA red. <br /> Exceptions: <br /> 1. Brass or bronze valves on sprinkler risers mounted to the exterior of the <br /> building may be left unpainted <br /> 2. _Where OS&Y valves on the detector check assembly are the only control <br /> valves, at least one OS&Y valve shall be ainted red <br /> Section 6.2.9 is hereby revised as follows: <br /> All connections to private fire service mains for fire protection systems shall be <br /> arranged in accordance with one of the following so that they can be isolated: <br /> (1)A post indicator valve installed not less than 40 ft (12 m) from the building <br /> a. For buildings less than 40 ft (12 m) in height, a post indicator valve <br /> shall be permitted to be installed closer than 40 ft (12 m) but at least <br /> as far from the building as the height of the wall facing the post <br /> indicator valve. <br /> b. Post indicating valves shall be allowed to be closer than 40 ft (12 m) <br /> to the building when a property line or other physical barriers make it <br /> impossible to have a post indicating valve 40 ft (12m) away. <br /> c. Post indicating valves shall be allowed to be closer than 40 ft (12 m) <br /> to the building when building driveway or fire access roadways or <br /> other building traffic make it impractical to be 40 ft (12 m). <br /> (2)A wall post indicator valve on risers located within the building, either a <br /> nonrising stem gate valve with a wall post indicator or a listed butterfly valve <br /> with an indicating handle extending out through the building wall. <br /> (3) A backflow preventer with at least one indicating valve not less than 40 ft <br /> (12 m) from the building <br /> (a) For buildings less than 40 ft (12 m) in height, a backflow preventer <br /> with at least one indicating valve shall be permitted to be installed <br /> closer than 40 ft (12 m) but at least as far from the building as the <br /> height of the wall facing the backflow preventer. <br /> Ordinance No. NS-3088 <br /> Page 24 of 27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.