My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-3088 - Building and Fire Codes
Clerk
>
Ordinances
>
2021 - 2030 (NS-3001 - NS-XXXX)
>
2025 (NS-3074 -NS-XXXX)
>
NS-3088 - Building and Fire Codes
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/29/2026 9:28:24 AM
Creation date
1/28/2026 12:39:30 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Agency
Community Development
Item #
29
Date
1/20/2026
Destruction Year
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
29
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
specifically amends the Residential Code. The Residential code, as thus <br /> amended, together with all other provisions of this article, shall be known as the <br /> city residential code. <br /> Appendices which are adopted pursuant to this section, are as follows: <br /> Appendix H, Patio Covers <br /> Section 12. Section 8-2810 of the Santa Ana Municipal Code is hereby amended to <br /> read as follows: <br /> Sec. 8-2810. - Climatic and Geographic Design Criteria (Table R301.2). <br /> Table R301.2 is revised to read: <br /> TABLE R301.2 <br /> CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br /> WIND DESIGN SUBJECT TO DAMAGE FROM BAICE <br /> RRIER <br /> GROUND Topo- Special Windborne SEISMIC UNDERLAY- AIR MEAN <br /> SNOW Speedd graphic wind debris DESIGN Weather- Frostline MENT FLOOD FREEZING ANNUAL <br /> LOAD* (mph) effectsk region' zonem CATEGORY' ing° Depth" Termite' REQUIREDh HAZARDS9 INDEX' TEMPI <br /> NFIP Date: <br /> 09/1411979 <br /> Current Map <br /> Very Date: <br /> Zero 1 95 1 No I No No D2 or E Negligible 12-24" 1 Heavy No 1210312009 0 60 <br /> MANUAL J DESIGN CRITERIA* <br /> Altitude correction Indoor winter design Indoor winter design dry-bulb Outdoor winter design Heating <br /> Elevation factor' Coincident wet bulb relative humidity temperature dry-bulb temperature temperature <br /> difference <br /> 115 1.00 69 70 38 <br /> indoor summer Indoor summer design dry- Outdoor summer design Cooling <br /> Latitude Daily range Summer design gains design relative bulb temperature dry-bulb temperature temperature <br /> humidity difference <br /> 34 26 75 88 <br /> For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. <br /> a. Where weathering requires a higher strength concrete or grade of masonry than <br /> necessary to satisfy the structural requirements of this code, the frost line depth <br /> strength required for weathering shall govern, The weathering column shall be filled in <br /> with the weathering index, "negligible," "moderate" or "severe" for concrete as <br /> determined from Figure R301.2(1). The grade of masonry units shall be determined <br /> from ASTM C34, ASTM C55, ASTM C62, ASTM C73, ASTM C90, ASTM C129, ASTM <br /> C145, ASTM C216 or ASTM C652. <br /> b. Where the frost line depth requires deeper footings than indicated in Figure R403.1(1), <br /> the frost line depth strength required for weathering shall govern. The jurisdiction shall <br /> fill in the frost line depth column with the minimum depth of footing below finish grade. <br /> c. The jurisdiction shall fill in this part of the table to indicate the need for protection <br /> depending on whether there has been a history of local subterranean termite damage. <br /> Ordinance No. NS-3088 <br /> Page 7 of 27 <br />
The URL can be used to link to this page
Your browser does not support the video tag.