fFl 905.4 Location of Class I standpipe hose connections. Class I <br />standpipe hose connections shall be provided in all of the following <br />locations: <br />1 . In every required stairway, a hose connection shall be provided for each <br />floor level above or below grade. Hose connections shall be located at an <br />intermediate floor level landing between floors, unless otherwise approved <br />by the fire code official. See Section 909.20.3.2 for additional provisions <br />in smokeproof enclosures. <br />2. On each side of the wall adiacent to the exit opening of a horizontal exit. <br />Exception: Where floor areas adiacent to a horizontal exit are <br />reachable from exit stairway hose connections by a nozzle attached <br />to 100 feet (30 480 mm) of hose, as measured along the path of <br />travels a hose connection shall not be required at the horizontal exit. <br />3. In every exit passagewav. at the entrance from the exit passagewav to <br />other areas of a building. <br />Exception: Where floor areas adiacent to an exit passageway are <br />reachable from exit stairway hose connections by a 30-foot (9144 <br />mm) hose stream from a nozzle attached to 100 feet (30 480 mm) <br />of hose, a hose connection shall not be required at the entrance <br />from the exit passagewav to other areas of the building. <br />4. In covered mall buildings, adiacent to each exterior public entrance to <br />the mall and adiacent to each entrance from an exit passagewav or exit <br />corridor to the mall. <br />5. Where the roof has a slope less than four units vertical in 12 units <br />horizontal (33.3-percent slope), each standpipe shall be provided with a <br />hose connection located either on the roof or at the highest landing of a <br />stairway with stair access to the roof. An additional hose connection shall <br />be provided at the top of the most hydraulically remote standpipe for <br />testincg purposes. <br />6. Where the most remote portion of a nonsprinklered floor or story is <br />more than 150 feet (45 720 mm) from a hose connection or the most <br />remote portion of a sprinklered floor or story is more than 150 feet (45 720 <br />mm) from a hose connection, the fire code official is authorized to require <br />that additional hose connections be provided in approved locations. The <br />distance from a hose connection shall be measured along the patch of <br />travel. <br />Ordinance No. NS-XXXX <br />7C A _? ? Page 6 of 50