My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
31B - CUP - 1901 NORTH FAIRVIEW ST
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2012
>
09/04/2012
>
31B - CUP - 1901 NORTH FAIRVIEW ST
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/22/2016 1:46:24 PM
Creation date
8/30/2012 12:38:32 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
31B
Date
9/4/2012
Destruction Year
2017
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
City of Santa Ana <br />Environmental Checklist <br />and air conditioning (HVAC) equipment would be used to ensure that the interior spaces of the <br />facility are comfortable for the occupants. The closest existing noise - sensitive land uses are the <br />multi- family residential residences located to the south of the project site and the medical facility <br />located to the north of the project site. HVAC units are expected to be located on the roof structures <br />throughout the project site. HVAC units could be located as close as 100 feet from the closest <br />existing noise- sensitive land use, The specific manufacturer and model of tile HVAC units have not <br />yet been determined. However, these units will be selected with the relevant City and building <br />standards as part of the performance specifications (i.e., acoustically engineered and tested by the <br />manufacturer to ensure that the noise standards would not be exceeded). In addition, the direct <br />view of the HVAC units will be screened by solid rooftop parapets (low walls), which would also <br />provide effective acoustical as well as visual screening. As a result, noise from the project's HVAC <br />equipment would be a less- than - significant impact. <br />Parking Lot Activity Noise. Parking lot activity will contribute to onsite ambient noise levels <br />through conversations, vehicle engines, car alarms, and doors slamming. The parking facilities will <br />be located on the perimeter of the project site, as shown on Figure 2 -5, which is bound by an existing <br />6 -Foot wall that will remain. The existing wall will hinder the parking lot noise from traveling to the <br />adjacent sensitive land uses. In addition, parking lot noise is short -term in duration. As a result, <br />noise related to operation of the parking facilities is less than significant. <br />Onsite Stationary Noise. Stationary onsite noise associated with the project will also include <br />basketball courts that will be outside in the location of Building F during operation of Phase I of the <br />project, The gymnasium (Building F) will be constructed during Phase It of the project. Noise from <br />typical school basketball court activities are estimated to be 60 dBA Leq at a distance of 50 feet (ESA <br />2005)5. The closest sensitive receiver is approximately 150 feet from the basketball courts and will <br />be screened visually and acoustically by the existing 6- foot -high concrete block wall. A noise level of <br />60 dBA would attenuate to 51 dBA Leq at a distance of 150 feet provided the receiver had direct line <br />of site, which would be below the City's daytime (7:00 a.m. to 10:00 p.m.) noise standard for <br />stationary sources. However, with the inclusion of a 6- foot -high block wall, noise levels would be <br />further reduced a minimum of 5 decibels, to approximately 46 dBA Leq. Therefore, noise from the <br />proposed basketball court will result in less- than - significant impacts. <br />b. Exposure of persons to orgeneration of excessivegroundborne vibration orgr-oundborne noise <br />levels? <br />Less - than - Significant Impact. The Federal Transit Administration (FTA) has compiled typical <br />vibration levels generated by construction equipment, which are commonly used as a reference for <br />construction vibration level analysis. The vibration levels produced by construction equipment are <br />outlined in Table 3 -19. <br />Vibration levels from construction equipment attenuate as they radiate from the source. The <br />equation to determine vibration levels at a specific distance states that <br />PPVeQ„ tp = PPV,f x (25/D) ^1.5 <br />where PPVrefis the Peak Particle Velocity at a reference distance of 25 feet, and D is the distance <br />from the equipment to the sensitive receptor (Jones & Stokes 2004). <br />5 Environmental Science Associates. 2005, Noise Monitoring. January 18. <br />The Academy Charter High School 3 78 June 2012 <br />Initial Study /Mitlgated Negative Declaration tCf 00914.11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.