My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75A - PH - ADOPT BUILDING AND FIRE CODES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2013
>
11/04/2013
>
75A - PH - ADOPT BUILDING AND FIRE CODES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2013 10:30:13 AM
Creation date
10/31/2013 4:29:59 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
75A
Date
11/4/2013
Destruction Year
2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 18: That section 8 -153 of the Santa Ana Municipal Code is hereby amended <br />such that it reads as follows: <br />Sec. 8 -153. Resepved. Standards for the Installation of Sprinkler Systems. <br />NFPA 13, 2013 Edition. Installation of Sprinkler Systems is hereby amended as <br />follows: <br />(a) Section 6.8.3 is hereby revised as follows: <br />6.8.3 Fire department connections (FDC) shall be of an approved type. The FDC <br />shall contain a minimum of two 2 Y2" inlets, The location shall be approved and be <br />no more than 150 feet from a public hydrant. The FDC may be located within 150 <br />feet of a private fire hydrant when approved by the fire code official. The size of <br />piping and the number of inlets shall be approved by the fire code official. If <br />acceptable to the water authority, it may be installed on the backflow, assembly. <br />Fire department inlet connections shall be painted OSHA safety red. When the fire <br />sprinkler density design requires 500 gpm (including inside hose stream demand) <br />or greater, or a standpipe system is included, four 2 '' /2" inlets shall be provided. <br />(b) Section 8.3.3.1 is hereby revised as follows: <br />8.3.3.1. When fire sprinkler systems are installed in shell buildings of undetermined <br />use (Spec Buildings) other than warehouses (S occupancies), fire sprinklers of the <br />quick - response type shall be used. Use is considered undetermined if a specific <br />tenantloccupant is not identified at the time the fire sprinkler plan is submitted. <br />Sprinklers in light hazard occupancies shall be one of the following_ <br />1. Quick - response type as defined in 3.6.4.7 <br />2. Residential sprinklers in accordance with the requirements of 8.4.5 <br />3. Standard - response sprinklers used for modifications or additions to <br />existing light hazard systems equipped with standard- response <br />3 <br />response sprinklers are replaced in existing light hazard systems <br />(c) Section 8.17.1.1.1 is hereby added as follows <br />Ordinance No. NS -XXXX <br />75A -31 Page 17 of 84 <br />
The URL can be used to link to this page
Your browser does not support the video tag.