My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75A - PH - ADOPT BUILDING AND FIRE CODES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2013
>
11/04/2013
>
75A - PH - ADOPT BUILDING AND FIRE CODES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2013 10:30:13 AM
Creation date
10/31/2013 4:29:59 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
75A
Date
11/4/2013
Destruction Year
2018
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
42
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 30: That section 8 -570 of the Santa Ana Municipal Code is hereby amended <br />such that it reads as follows: <br />Sec. 8 -570. Ducts -- Material (Section 602.1). <br />Section 602.1 of the mechanical code is amended to read as follows: <br />602.1 General. Supply air, return air, and outside air for heating, cooling, <br />or evaporative cooling systems shall be conducted through duct systems <br />constructed of metal as set fafth in the in accordance with SMACNA <br />HVAC Duct Construction Standards - <br />Metal and Flexible, or anetheF approved duet eenStMetien standard. <br />Rectangular ducts ,n-��two (2) inches w.g. shall comply with the <br />SMACNA HVAC ANSYSMAGNA 006 2006 HVAG Duct Construction <br />Standards - Metal and Flexible, or another appFE)Yed duet 8Gn6#UGtiGR <br />standard. Ducts, plenums, and fittings may shall be permitted to be <br />constructed of concrete, clay, or ceramics when installed in the ground or <br />in a concrete slab, provided the joints are tightly sealed. <br />In other than Group A, E, H, I, L, and R occupancies, high -rise buildings, <br />and other applications listed in Section 1.11.0 regulated by the Office of <br />the State Fire Marshal, corridors shall not be used to convey air to or from <br />rooms if the corridor is required be of fire - resistive construction per the in <br />accordance with the Building Code. In Group A, E, H, I, L, and R <br />occupancies, high -rise buildings, and other applications listed in Section <br />1. 11.0 regulated by the Office of the State Fire Marshal, corridors shall not <br />be used to convey air to or from rooms except where permitted in <br />accordance with Section 1018.5 of the California Building Code. <br />Exception: [OSHPD 1, 2, 3 & 4] (See Section 407.4.1.3). <br />Not permitted for [OSHPD 1, 2, 3 & 4] Concealed building spaces or <br />independent construction within buildings racy shall be permitted to be <br />used as ducts or plenums. <br />When gypsum products are exposed in ducts or plenums, the air <br />temperature shall be restricted to a range from 50 °F (10 °C) to 125 °F <br />(52 0C), and moisture content shall be controlled so that the material is not <br />adversely affected. For the purpose of this section, gypsum products shall <br />not be exposed in ducts serving as supply from evaporative coolers, and <br />in other air - handling systems regulated by this chapter when the <br />temperature of the gypsum product will be below the dew point <br />temperature. <br />See Chapter 8 for limitations on combustion products venting systems <br />extending into or through ducts or plenums. <br />Ordinance No. NS -XXXX <br />75A -39 Page 25 of 84 <br />
The URL can be used to link to this page
Your browser does not support the video tag.