PCC NETWORK SOLUTIONS, A PACIFIC COAST CABLING, INC. CO. 5 -2013
Clerk
>
Contracts / Agreements
>
P
>
PCC NETWORK SOLUTIONS, A PACIFIC COAST CABLING, INC. CO. 5 -2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/21/2016 5:10:33 PM
Creation date
2/24/2014 9:50:57 AM
Metadata
Fields
Template:
Contracts
Company Name
PCC NETWORK SOLUTIONS, A PACIFIC COAST CABLING, INC. CO.
Contract #
A-2013-144
Agency
FINANCE & MANAGEMENT SERVICES
Council Approval Date
9/3/2013
Expiration Date
8/31/2016
Insurance Exp Date
1/1/2017
Destruction Year
2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.10.5.1.2.1.4. Near -end Crosstalk (NEXT) <br />2.10.5.1.3. Adjust, repair, and /or replace defective material and equipment. <br />2.10.5.2. Optical fiber media: <br />2.10.5.2.1. Perform one direction patch panel port to patch panel port light <br />source /power meter attenuation testing on all terminated fibers at <br />both 850nm and 1300nm windows. Test in accordance with <br />ANSI /E IA/TIA- 526 -14. <br />2.10.5.2.2. Adjust, repair, and /or replace defective material and equipment. <br />2.10.6. Walk each installation with the Telecommunications Coordinator, and: <br />2.10.6.1. Correct any noted defects in installation practices or labeling. <br />2.10.6.2. Adjust, repair, and /or replace defective material and equipment. <br />2.10.7. Failures detected during the testing shall be duly noted on the schedule, <br />rectified and tested. On the fault being rectified this shall also be noted. <br />These notes shall not be deleted or obliterated. Rectification of all damaged <br />cables shall include replacing damaged cables with new cables in complete <br />runs. In -line cable joints, splices or distribution points will not be acceptable. <br />All damaged cables shall be removed from the site. <br />2.10.8. Tabulate all test data. Prepare an electronic report covering all testing <br />performed and test results. Provide electronic report and all final test results <br />documentation to the Telecommunications Coordinator and obtain receipt. <br />F1�f�K�ldW1114d II <br />2.11.1. The work hereunder will not be reviewed for final acceptance until all <br />required labeling, maintenance data, identification, warning signs, as built <br />and test result documentation, and warranty certification documents have <br />been reviewed and approved and final cleaning has been completed. <br />2.11.2. The cable plant installation will be deemed acceptable when the vendor <br />delivers to the Telecommunications Coordinator the following: <br />2.11.2.1. Fully installed and properly terminated and labeled UTP copper <br />cable plant that is 99.9999% free of defective copper pairs. <br />2.11.2.2. Fully installed and properly terminated and labeled fiber optic cable <br />plant which are 99.9999% free of defective fiber links, where a <br />defective link is defined as a link whose tested attenuation exceeds <br />Page 18 of 24 <br />