My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
23A - PROJ - WATER MAIN IMPROVEMENTS
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2014
>
12/02/2014
>
23A - PROJ - WATER MAIN IMPROVEMENTS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/26/2014 3:00:25 PM
Creation date
11/26/2014 2:51:39 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
23A
Date
12/2/2014
Destruction Year
2019
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
134
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO. 11 -6416 <br />SEVENTEENTH STREET WATER MAIN IMPROVEMENTS <br />Fittings shall be gray or ductile iron conforming to AWWA Standards and shall be push -on- <br />joint (P.J.), mechanical joint (M.J.) or flanged (FLG) except where noted otherwise. All valves <br />to fitting connections shall be flanged. Valves for lateral lines, hydrant leads and service lines <br />shall be bolted directly to main line tee, unless otherwise noted on plans. Where it is <br />necessary to install a reducer or other type of fitting between the lateral valve and main line, <br />said fitting shall be flanged at both ends. <br />All flanged fittings and connections shall comply with the applicable provisions of AWWA <br />C110. The bolt circle and boltholes of these flanges shall match those of the Class 125 flanges <br />shown in ANSI B16.1. <br />The Contractor shall coordinate the flange requirements with the connecting pipe and valve <br />manufacturers. <br />Contractor shall provide flange to connecting pipe adapters as needed. Adapters may be <br />flange by push on fittings (FLG x P.J.) or flange by mechanical joint (FLG x M.J.) adapter. "E -Z <br />Flange" and similar setscrew type adapters are not acceptable. Grip rings for PVC pipe <br />restraint, such as Romac RomaGrip are acceptable. <br />All ductile iron and gray -iron fittings shall be manufactured in accordance with all applicable <br />requirements of ANSI /AWWA Standards and Specifications. <br />Concrete thrust blocks shall be provided at all valves, fittings and hydrants in accordance with <br />AWWA Standards and City of Santa Ana Standard Plans Nos. 1412 and 1420. <br />Installation shall be in accordance with AWWA Manual No. M23 - "PVC Pipe Design and <br />Installation" and the manufacturer's recommendations. Pipe sections shall not be deflected <br />at anyjoint, either vertically or horizontally, beyond the limits specified by the manufacturer. <br />Pipe shall not be dropped into trench. <br />All ductile iron or gray iron fittings, valves, and appurtenances buried underground shall be <br />wrapped with 10 mils polyethylene sheeting. Any existing or connecting iron pipe and <br />appurtenances that are exposed as a result of this pipe installation shall also be wrapped with <br />polyethylene sheeting. This shall be done in accordance with AWWA C105 -99. <br />All nuts and bolts shall be cadmium plated and shall have NON -OXIDE GREASE or mastic such <br />as 3M EC244, or Koppers Bitumastic 505 applied to the threads prior to installation and <br />reapplied prior to wrapping. <br />The existing water main facilities shown on the plans are at or near the same elevation as the <br />new main. <br />T -3h <br />23A -103 <br />
The URL can be used to link to this page
Your browser does not support the video tag.