Laserfiche WebLink
CITY OF SANTA ANA <br />SPECIFICATIONS <br />PROJECT NO. 11 -6416 <br />SEVENTEENTH STREET WATER MAIN IMPROVEMENTS <br />a. Casing pipe and carrier pipe material including the standard to which it is manufactured, <br />outside diameter, wall thickness, joint configuration, and certificate of compliance <br />certifying that the pipe meets these specifications. <br />b. Details of casing spacers, including manufacturer's recommended spacing. <br />c. Details of end seals for casing. <br />d. Working drawings of jacking pit and receiving pit <br />e. Details of jacking pit bracing, casing, jacking head, concrete support blocks, bracing to <br />prevent pipe shifting or floatation. <br />f. Concrete mix design. Concrete placement method and equipment. <br />g. As -built drawings to include both alignment and profile. Drawings should be constructed <br />from actual field measurements. Raw data shall be submitted as part of the As -built <br />document. Contractor shall stipulate the tracking method to ensure the data was <br />captured. <br />T -3x <br />23A -119 <br />