2.0 Sound Transmission: <br />The existing exterior wails, of the four buildings, are of 6" concrete tilt up walls <br />(excellent barrier for low frequency sound waves). It is our opinion that in a 6" <br />concrete tilt up building with a minimum windows opening provides sufficient <br />soundproofing and noise reduction. <br />3.0 Title 24 Requirements: <br />Based on our visual observation, and based on the type of construction, (6" <br />concrete tilt up walls), the walls for the 4 buildings, provide an excellent R value <br />to meet the current Title 24 energy conservation requirements. Also, we had <br />observed that R 30 insulation was installed in the ceiling, which also meet the <br />current Title 24 energy conservation requirements. The only area in question will <br />be the existing windows that might not meet Title 24 requirements. For the <br />replacement of all glazing not meeting current heat loss, heat gain, or infiltration <br />requirements, the process would be very expensive and time consuming. The <br />cost associated with the above compliance is estimated to be $139,000. <br />4.0 Ogren Space: <br />The Zoning for this site is Specific Development District No. 8 (Brookhollow <br />Office Park), The SD -8 requires that structures shall not cover more than 55 <br />percent of the total net site area. In this case, the total net site area is <br />approximately 254,609 square feet (5.845 Acres) and the combined building area <br />across the eight air -right condominium units is 87,177 square feet (0.499 Acres) <br />or approximately 34 percent of the net site area. As there is no new construction <br />proposed as part of this subdivision, the amount of open space will not be <br />affected and will not exceed the coverage permitted. Any future development will <br />comply with the provisions of the Santa Ana Municipal Code. <br />5.0 Setbacks: <br />SD -8 zoning requires front setbacks along private streets of 20 feet, side yard <br />setbacks of 10 feet and rear yard setbacks of 10 feet. All setbacks within the <br />proposed project conform to these requirements. As there is no new <br />construction proposed as part of this subdivision, conformity will not be affected. <br />Any future development will comply with the provisions of the Santa Ana <br />Municipal Code. <br />6.0 Design Guidelines: <br />The proposes subdivision, as conditioned, and its design and improvements will <br />be consistent with the Professional and Administrative Office (PAO) land use <br />designation of the General Plan and are otherwise consistent with all other <br />Elements of the General Plan and applicable Specific Plans. The proposed <br />subdivision located within the SD -8 zoning district which is consistent with the <br />PAO land use designation and all other elements of the General Plan as well as <br />provisions outlined in Chapter 34 of the Santa Ana Municipal Code for the <br />4887 E. La Palma Ave. Suite 707, Anaheim, CA 92807 — Phone (714)695 -9300 — Fax (714)693 -1002 <br />32C -18 <br />