Laserfiche WebLink
Bowers Museum Access Compliance Survey Report 1 -1 -1 <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. $ Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Signage <br />167 • As -Built Description: 1 JOB <br />At final exit door to exterior: Where required exit PCODE SA10A <br />signs are installed, signs to provide exiting ADAAG 4.13 {16} <br />information for people with vision impairment are ADA 2010 216.41 <br />not provided. - CBC 2010 1411.3 <br />• Proposed Solution: CBC 2013 118 - 216 .4.1 <br />Provide raised letter /Braille "EXIT" sign at door. <br />• Notes: <br />State historic building codes are not applicable. <br />Stairwa V <br />165 • As -Suitt Description: <br />The leading 2" of the tread does not have visual PCODE 1102B <br />contrast of dark —on —light or light—on—dark from the ADA 2010 504.4 <br />remainder of the tread. CBC 2010 1133B.4.4 <br />• Proposed Solution: CBC 2013 f iB- 544.41 <br />Provide 2" wide contrasting color stripe 1" max. <br />from nosing on top & bottom treads when altering <br />area <br />• Notes: <br />State historic building codes are not applicable. <br />70 LF <br />Decruber 15, 2014 Sally Swanson Architects, Inc. Profecin 14048 Survey Data - Page 25 <br />