Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />3 Auditorium Lobby Men's Restroom <br />Door Closer <br />IV • As -Built Description: <br />Excessive force required to open door. ADAAG 1803 <br />DAAG 4.23.11 <br />• As -Bulll: 9 lbs ADA 2010 404.29 <br />Proposed Solution. <br />Adjust regular door closer to accessible standards (5 CBC 2010 1133B2.5 <br />lbs max). CBC 2013 11B- 404.2.9 <br />Notes: <br />State historic building codes are not applicable. <br />Protrusion Limits <br />191 • As -ButR Description: <br />Protruding objects more than 4" from wall, when PCODE PG04 <br />bottom of object more than 27" or less than 80" ADAAG 4.43 <br />above finished floor. ADA 2010 307.2 <br />• Proposed Solution: CBC 2010 1133B.8.6.1 <br />Remove /relocate protruding object. Patch existing CBC 2013 11B- 307.2 <br />surface, <br />• Notes: <br />Ensure that BCS is closed when not in usc, <br />Accessible u -pull or opening device also <br />required. <br />State historic building codes are not applicable. <br />Signa1: <br />133 + As -Built Description: <br />T <br />Plant within clear floor space of signage. <br />ADAAG' 4.30,6 <br />ADAAG 4,30.6 <br />• Proposed Solution: <br />ADA 2010 703.4.1. <br />Relocate plant. <br />CBC 2010 1117B.5.7 <br />Notes: <br />State historic building codes are not applicable. <br />CBC 2013 11B- 703.4.2 <br />2 JOB <br />immeri <br />1 JOB <br />December 18, 2014 Sally Swansan Architects, Inc. Project 4 14048 Survey Data - Page 30 <br />