Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />7 Thompson Foyer <br />Alarm Signal <br />270 - As -Built Description: 1 JOB <br />At facility with a fire alarm system, visual signal PCODE IC05 <br />(strobe) not provided at required type of common ADAAG 4.1.3(14) & 4.28.3 <br />use area. ADA 2010 215.1 & 702.1 <br />- Proposed Solution: <br />Provide combination visual / audible signal device <br />connected to existing fire alarm system. <br />- Notes: <br />State historic building codes are not applicable. <br />Brochure Bins <br />211 - As -Built Description: <br />Information brochure bins mounted above <br />accessible height of 48 ". <br />As- Built: 34 " -57" <br />- Proposed Solution: <br />Relocate /remount bins at accessible height. <br />- Notes: <br />Provide same brochures at lower height. <br />State historic building codes are not applicable. <br />CBC 2010 1 i 14B,2.2 <br />CBC 2013 11B -215.1 & IIB <br />-702.1 <br />PCODE INO8 <br />ADAAG 4.2.5 & 6 <br />ADA 2010 308.2.1 <br />CBC 2010 1118B.5 <br />CBC 2013 11B- 308.21 <br />inn e <br />209 - As -Built Description: <br />At final exit door to exterior: Where required exit PCODE SAlOA <br />signs are installed, signs to provide exiting ADAAG 4,1.3(16) <br />information for people with vision impairment are ADA 2010 216.43 <br />not provided. CBC 2010 10113 <br />- Proposed Solution: CBC 2013 1IB- 216.4.1 <br />Provide raised letter /Braille "EXIT" sign at door. <br />- Notes: <br />State historic building codes are not applicable. _ <br />111917 <br />2 JOB <br />December 15, 2014 S a l l y S xn a n s o n Architects, ! n c . Project # 14048 Sin voy Data -Page 39 <br />