Laserfiche WebLink
Bowers Museum Access Compliance Survey Report <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit <br />Public Counter <br />239 • As -Built Description: <br />Public Counter (Seated Service): Accessible section PCODE [Y03A <br />not provided (knee space min. 27' high x 19" deep ADAAG 432.3 do 4 <br />x 30" wide, top 28" to 34" high, min. 36" counter ADA 2010 3063; 404.4 <br />wide). CBC 2010 1122113 & 4 <br />235 <br />• As- Built: 42.25' CBC 2013 1IB- 306.3; 11B -904.4 <br />• Proposed Solution: <br />Retrofit existing counter to provide accessible <br />seating section. <br />Interim solution: Provide auxiliary counter or table. <br />• Notes: <br />State historic building codes are not applicable. <br />1 JOB <br />• Proposed Solution: CBC 2013 1111- 216.41 <br />Provide raised letter/Braille "EXIT" sign at door. <br />• Notes: <br />State historic building codes are not applicable. <br />290 As -Bunt Description <br />At final exit door to exterior: Where required exit PCCDE SAl0.A <br />signs are installed; signs to provide exiting ADAAG 413(16) <br />information for people with vision impairment are ADA 2010 216.41 <br />not provided. CBC 2010 1011.3 <br />•As- Built: To plaza CBC201311B- 216.4.1 <br />• Proposed Solution.: <br />Provide raised letter /Braille "EXIT' sign at door. <br />• Notes: <br />State historic building codes are not appbcable. <br />December 15, 2014 S a l t y S w a n s o n R r c h i t e cis, In r. Project # 14048 Survey Data - Page 48 <br />