Laserfiche WebLink
Bowers Museum Access Compliance Survey Report 1 -1 -1 <br />Facility: Bowers Museum Part: Interior Floor: Ground Floor <br />Address: 2002 N Main St, Santa Ana, CA 92706 <br />Existing Architectural Barrier <br />Item No. $ Name and Proposed Solution <br />Codes I Mitigation Info <br />13 Muth Wing <br />Corridor <br />249 - As -Built Description. <br />PCCDE IBObANT <br />Corridor less than 36" wide, <br />PCCDE IR43 <br />- Proposed Solution: <br />ADAAD 4.33 <br />• As- Built. 35.5" at bottom tiles. 32" deep <br />ADA 2010 403.5.1 <br />• Proposed Solution: <br />Enlarge corridor to 36" wide; remove tiles along <br />CBC 2010 113313.3.1 <br />bottom of walls in corridor and refinish. Or identify <br />CBC 2013 1111- 403.5.1 <br />as a qualifying historical feature. <br />. Notes: <br />Historical restoration qualified. <br />Curb or Barrier <br />247 - As -Built Description: <br />No curb (2" minimum height) or wheel guide <br />PCODE EB14 <br />(centered approx. 3" above surface of ramp) at sides <br />ADAAG 4,8,7 <br />of ramp. <br />ADA 2010 405.9.2 <br />- Proposed Solution: <br />CBC 2010 113311.5.6 <br />Provide 2" minimum curb or wheel guide. <br />CBC 2013 11B- 405.9.2 <br />Door <br />254 - As -Built Description: <br />At push side of door on accessible route, bottom <br />PCCDE IBObANT <br />t0" does not have a smooth, uninterrupted surface. <br />ADA 2010 404.2.10 <br />- Proposed Solution: <br />CBC 2010 1133B.2.6 <br />Install Icicle plate at bottom 10" of door to cover <br />CBC 2013 1113- 404.2.10 <br />floor latch and floor latch rods or provide compliant <br />throw- bolts. <br />Qty Unit <br />December 13, 2014 S a l l y Swanson A r c h i t e c t s , In c. Project # 14048 Survey Data - Page 51 <br />