CITY OF SANTA A:NA <br />RFP NO,: 15-094 <br />WATER WELL, PUMP AND MOTOR REPAIR, SERVICES <br />delivery/pick .up for the repair and refurbishment of electric motors and perform any recondition or rewiring <br />as necessary to return the equipment fully operational.. All. electric motor repair shall be done inan <br />EASAAccredited Member service shop, no exceptions, <br />a. All work shall be in accordance with. the Electrical Apparatus Service Association's (EASA) <br />Recommended Practice, AR100.2015 latest edition and the National Electrical Manufacturers <br />Association (NEMA) standards for service and repair of electrical apparatus. <br />J. Work shall be in conformance with standards set by, but not limited to, the following organizations: <br />1, Underwriters Laboratories (UL) <br />a. Underwriters Laboratories — Certified motors shall be recertified after repair. <br />b. Contractor's shop or his sub -contractor's shop shall be UL -certified to rebuild explosion -proof <br />electric motors for use in hazardous environments. <br />2. American National Standards Institute (ANSI) <br />3. American Society for Testing and Materials (ASTM) <br />4. National Electrical Code (NEC) <br />5. National Fire Protection Agency (NEPA) <br />6. National Electrical Manufacturers Association (NEMA) <br />Recondition/Repair of Electric Motors <br />Reconditioning/repair of electric motors shall include the testing, disassembling,inspection,. cleaning <br />dipping, baking of windings, 'replacement of bearings, assembly, testing and painting and at rtiintmurii <br />inciude thq following; <br />a. Pre-DisassembtyTest <br />1, Using a 1000V meg-ohm meter, conduct verification of insulation Integrity.. Record the insulation <br />resistance of the motor as brought In from the City. Acceptable criteria is 5 meg-ohms or higher, <br />2. Verify that heaters are operational and that other attached features, such as thermocouples, have <br />continuity. <br />3, Single-phase test to check for open rotors. (After disassembly, rotors will be inspected for evidence <br />of damaged, cracked or open circuit bars or end rings. If there is evidence of faults, the rotor will be <br />growl -tested.) The detection of any defect during testing shall be reported promptly to the Engineer <br />4. Documentation covered under this section shall include the'condition of mechanical fits (i.e. shaft <br />run out), cracked, broken or missing parts, test run at full voltage, current readings, meg reading <br />and surge comparison test as received. The Engineer shall be notified if acceptable criteria are not <br />met. <br />b. Motor Disassembly <br />1. Completely disassemble motor and steam clean all mechanical parts using a mild detergent <br />compatible with winding insulation; thoroughly rinse; bake dry. <br />2. Disassembly documentation shall include the cause of failure and/or conditions contributing to <br />failure. <br />c. Motor Inspection <br />25C-55 <br />