Laserfiche WebLink
Sec. 8.2810. Climatic and Geographic Design Criteria (Table R301.2(1)). <br />Table R301.2(1) is revised to read: <br />TABLE R301.2(1) <br />CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA <br />GROUND <br />WIND DESIGN <br />SEISMIC <br />SUBJECT TO DAMAGE FROM <br />WINTER <br />ICE BARRIER <br />AIR <br />MEAN <br />Speed <br />Frost <br />SNOW <br />^ <br />Topographic <br />DESIGN <br />line <br />DESIGN <br />UNDERLAYMENT <br />FLOOD <br />FREEZING <br />ANNUAL <br />LOAD <br />m h <br />effects" <br />CATEGORY I <br />Weathering <br />Depth , <br />Termite I <br />TEMP- <br />REQUIRED <br />HAZARDS9 <br />INDEX' <br />TEMPI <br />Very <br />1 <br />See <br />Zero <br />110 <br />No <br />Dz or E <br />Negligible <br />12.24" <br />Heav <br />43 <br />No <br />Exhibit B <br />0 <br />60 <br />For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m /s. <br />a. Weathering may require a higher strength concrete or grade of <br />masonry than necessary to satisfy the structural requirements of this code. <br />The weathering column shall be filled in with the weathering index (i.e., <br />"negligible," "moderate" or "severe ") for concrete as determined from the <br />Weathering Probability Map [Figure R301.2(3)]. The grade of masonry <br />units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C <br />129, C 145, C 216 or C 652. <br />b. The frost line depth may require deeper footings than indicated in <br />Figure R403.1(1). The jurisdiction shall fill in the frost line depth column <br />with the minimum depth of footing below finish grade. <br />C. The jurisdiction shall fill in this part of the table to indicate the need <br />for protection depending on whether there has been a history of local <br />subterranean termite damage. <br />d. The jurisdiction shall fill in this part of the table with the wind speed <br />from the basic wind speed map [Figure R301.2(A)].Wind exposure <br />category shall be determined on a site - specific basis in accordance with <br />Section R301.2.1.4. <br />e. Temperatures shall be permitted to reflect local climates or local <br />weather experience as determined by the building official. <br />f. The jurisdiction shall fill in this part of the table with the seismic <br />design category determined from Section R301.2.2.1. <br />g. The jurisdiction shall fill in this part of the table with (a) the date of <br />the jurisdiction's entry into the National Flood Insurance Program (date of <br />adoption of the first code or ordinance for management of flood hazard <br />areas), (b) the date(s) of the Flood Insurance Study and (c) the panel <br />numbers and dates of all currently effective FIRMs and F13FMs or other <br />Ordinance No. NS -XXXX <br />Page g of 31 <br />11A -11 <br />