My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FULL PACKET_2016-12-06
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2016
>
12/06/2016
>
FULL PACKET_2016-12-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2016 10:25:30 AM
Creation date
12/5/2016 9:49:40 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Date
12/6/2016
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
1396
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1. Brass or bronze valves on sprinkler risers mounted to the exterior of the <br />building may be left unpainted. <br />2. Where OS &Y valves on the detector check assembly are the only control <br />valves, at least one OS &Y valve shall be painted red. <br />(2) Section 6.2.9 is hereby revised to read as follows: <br />All connections to private fire service mains for fire protection systems shall be <br />arranged in accordance with one of the following so that they can be isolated: <br />(1) A post indicator valve installed not less than 40 ft (12 m) from the building <br />(a) For buildings less than 40 ft (12 m) in height, a post indicator valve <br />shall be permitted to be installed closer than 40 ft (12 m) but at least as far <br />from the building as the height of the wall facing the post indicator valve. <br />(2) A wall post indicator valve <br />(3) An indicating valve in a pit, installed in accordance with Section 6.4 <br />(4) A backflow preventer with at least one indicating valve not less than 40 ft <br />(12 m) from the building <br />(a) For buildings less than 40 ft (12 m) in height, a backflow preventer <br />with at least one indicating valve shall be permitted to be installed <br />closer than 40 ft (12 m) but at least as far from the building as the <br />height of the wall facing the backflow preventer. <br />(5) Control valves installed in a fire -rated room accessible from the exterior <br />(6) Control valves in a fire -rated stair enclosure accessible from the exterior <br />(3) Section 10.1.5 is hereby added as follows: <br />101.5 All ferrous pipe and joints shall be polyethylene encased per AWWA <br />C150, Method A, B, or C. All fittings shall be protected with a loose 8 -mil <br />polyethylene tube or sheet. The ends of the tube or sheet shall extend past the <br />joint by a minimum of 12 inches and be sealed with 2 inch wide tape approved for <br />underground use. Galvanizing does not meet the requirements of this section. <br />Exception: 304 or 316 Stainless Steel pipe and fittings <br />(4) Section 10.4.1.1 is hereby revised to read as follows: <br />Ordinance No. NS -XXXX <br />Page 28 of 31 <br />11 A -30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.