Laserfiche WebLink
hl The system will be used in vertical waste stacks for water closets, lavatories. bathtubs. <br />showers and kitchen sinks. <br />C The Soaent system will not be connected to clothes washers, <br />We have carefully reviewed the applicable provisions of the 2016 C'ald'onsia Plumbing Code, as <br />well as Che submitted documentations, and hereby grant approval for requested use of a Sovent <br />system. C'cnnbinec( waste vent Sovent system has been in use for several years in many US cities <br />and it has demonstrated reliable performance wiCl2 no loss of trap of Heal or unusual blockages. In <br />addition, the building is historical and Che use of the Sovent system reduces the number or <br />penetrations to be made in the eeiating slab and wall,. This approval of the use of the Sovent <br />system is subject to the following condition,. <br />1. The plumbing system shall be designed by a California registered Mechanical Engineer, <br />3 The NT chanical Engineer ut responsible charge of the project shall perform field <br />observations during construction and will certify to the Building official in writing the <br />completion of the project that the Sovent system was installed per the intended design and <br />based on the approved plans. <br />�. Building maintenance personnel will be trained by tlse plumbing contractor on the <br />maintenance and operation of tite proprietary system. <br />=6.Ahold harmless agreement executed by the property owner and applicable to any Vature <br />owners and users of the building to the satisfaction of the City of Santa shall be recorded in <br />the Country recorder's office. <br />5. Third Party inspecticnt to be provided as per section 1.704 of tile California Building Code. <br />ermanently incorporated and pasted on the construction <br />A Dopy or thio approval letter shall be p <br />plans. <br />