Laserfiche WebLink
SPR No. 2016-03, VA No. 2017-05, VA No. 2017-06 <br />December 11, 2017 <br />Page 4 <br />for the most intensive development and designed to create a highly urbanized environment. After <br />analyzing the project, staff finds that the proposed project is in compliance with all applicable <br />development standards, with the exception of required on-site parking and the side yard setback, as <br />indicated in Table 3 below. <br />Table 3: Conformance to Development Standards <br />Standard <br />Re uired by MEMO -Active Urban District <br />Provided <br />Maximum Number Stories <br />No Maximum, 3 Stories Minimum <br />Seven stories <br />Minimum Development Site Area <br />One acre <br />2.79 acres <br />Permitted Street Level Building <br />Frontages <br />Forecourt <br />Forecourt <br />Publicly Accessible Open Space <br />15% of Total Lot Area =18,230 sq. ft. <br />20,733 sq. ft. <br />Private/Common Open Space <br />100 sq. ft. per unit = 26,000 sq. ft. <br />45,109 sq. ft. <br />Building <br />Front Yard <br />0-20 ft. <br />11 ft. <br />Setbacks <br />Side Yard <br />0-10 ft. <br />30 ft. — variance <br />required <br />Rear Yard <br />0-10 ft. <br />1511t. <br />Parking <br />Mixed-use with less than 10% of gross floor area <br />devoted to a commercial activity: 2.0 spaces per <br />residential or live/work unit inclusive of guest parking <br />and any nonresidential uses = 520 spaces <br />1.71 spaces per unit = <br />445 spaces — variance <br />required <br />Variances <br />The applicant is requesting the approval of two variances to allow a 14 -percent reduction in <br />required parking and a 30 -foot side yard setback in lieu of a maximum 10 -foot side yard setback. <br />Pursuant to Section 41-632.2 of the SAMC, the Planning Commission may grant a variance to <br />development standards when it can be shown that there exists a special circumstance related to <br />the property, is necessary for the preservation and enjoyment of substantial property rights, will <br />not be detrimental to the public or surrounding property, and will not adversely affect the General <br />Pian. If these findings can be made, then it is appropriate to grant the variances. Conversely, the <br />inability to make these findings would result in a denial. Staff has prepared the following analysis <br />that forms the basis for the variance recommendations contained in this report. <br />Reduction in Parking <br />Table 4: Conformance to Parking Requirements <br />Standard <br />Required by MEMU Section 4.8 <br />Provided <br />Mixed-use <br />Minimum of 2.0 <br />Parking Spaces <br />developments with <br />spaces per residential <br />Required <br />D <br />less than 10% of <br />or live/work unit <br />2.0 spaces x 260 units = <br />1.71 spaces x 260 units = <br />the gross floor area <br />inclusive of guest <br />520 spaces required <br />445 spaces provided <br />devoted to a <br />parking and any <br />commercial activity. <br />nonresidential uses <br />75A-12 <br />