Loading...
HomeMy WebLinkAbout75A - PH ZONING ORD AMENDMENTREQUEST FOR COUNCIL ACTION CITY COUNCIL MEETING DATE: JULY 2, 2019 TITLE: CONTINUED PUBLIC HEARING — ZONING ORDINANCE AMENDMENT NO. 2019-03 TO AMEND CERTAIN DEVELOPMENT AND DESIGN STANDARDS APPLICABLE WITHIN THE TRANSIT ZONING CODE (SPECIFIC DEVELOPMENT NO. 84) ZONING DISTRICT — CITY OF SANTA ANA, APPLICANT (STRATEGIC PLAN NO. 3, 2; 5, 3) CITY MANAGER RECOMMENDED ACTION CLERK OF COUNCIL USE ONLY: APPROVED ❑ As Recommended ❑ As Amended ❑ Ordinance on 181 Reading ❑ Ordinance on 2nd Reading ❑ Implementing Resolution ❑ Set Public Hearing For_ CONTINUED TO FILE NUMBER Adopt an ordinance approving Zoning Ordinance Amendment No. 2019-03 amending certain development and design standards applicable within the Transit Zoning Code (Specific Development (SD) No. 84) zoning district. BACKGROUND & DISCUSSION At the regular City Council meeting on June 4, 2019, the City Council conducted the public hearing regarding Zoning Ordinance Amendment (ZOA) No. 2019-03. After receiving staffs presentation and the recommendation from the Planning Commission on this matter, the City Council continued the public hearing for further clarifications regarding the boundaries of the Transit Zoning Code (TZC),where the proposed changes are applicable, the decision -making and review process for development projects within the TZC, and the proposed parking options and changes within the TZC. The TZC was adopted by the City Council on June 7, 2010. As a form -based code, the TZC regulates the physical form of development projects and buildings affecting the public realm in addition to traditional zoning regulations relating to uses, parking, and setbacks. Since its adoption in 2010, the TZC regulations have not achieved the overarching goals of integrating new development and the rehabilitation of existing structures in the zoning district, and have not stimulated significant new developments within the TZC zoning district. Feedback from the development community over the years indicates that the existing regulations are not practical and at times, prohibitive in an existing environment with small parcels having limited frontage and depth. 75A-1 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 2 The goal of the proposed amendments are to update the regulations and design requirements within the TZC and to incorporate best planning and land use practices to meeting the goals of the TZC. The proposed revisions addresses building heights, off-street parking options, parking driveway standards, open space standards, and building massing and setbacks standards within the TZC zoning district. Updated Report and Clarifications This updated RFCA report addresses City Council concerns and questions and provides a summary of the proposed revisions to the TZC as follows: Transit Zoning Code Boundaries: The TZC boundaries include Flower Street to the west, Civic Center Drive and Washington Avenue to the north, Santa Ana (1-5) Freeway and Grand Avenue to the east, and First Street to the south. The TZC location within the City of Santa Ana is highlighted on the map below in blue (Figure 1). Figure 1. Transit Zoning Code (Specific Development 84) Zoning District & Area of Applicability Transit Zoning Code Sub -Districts Affected by the Proposed Amendments: The TZC establishes eight separate sub -districts. These sub -districts are defined by the type and density of development permitted. The sub -districts are listed in order of intensity below with the Transit Village sub -district allowing the most intensive developments and the Open Space sub -district the least intensive developments. 75A-2 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 3 • Transit Village (TV) • Government Center (GC) • Downtown (DT) • Urban Center (UC) • Corridor (CDR) • Urban Neighborhood 2 (UN-2) • Urban Neighborhood 1 (UN-1) • Open Space (0) The proposed revisions will only affect the TV, DT, and UC sub -districts of the TZC and are shown on the map below in dark red, red -orange, and orange without crosshatching respectively. I N w+E. -Ca.MY�CDNI IIMnMwpllpellleW IUIFI•S �.Jn� -Db.nb.n ICI, ! IMMMW�YTm0,U1F11 O�_ _ 4wwnmTC IOCI � y InUUM1W OwIM\�I OE e _ py�,Bpy1061 IMUWIC\YIq M3 OEI � � � �. ��. 84B ` ! R!;r' Figure 2. Transit Zoning Code Boundaries and Sub -Districts Transit Zoning Code Review Authority. The decision -making and review process for development projects within the TZC were established in 2010 with the adoption of the TZC and include a combination of by -right and discretionary processes and procedures. Figure 3 below outlines the established decision -making and review process for the development projects proposed within the TZC. Currently, all General Plan Amendments, Zone Changes, and Code Amendments related to the TZC requires City Council approval. Discretionary actions such as Conditional Use Permits, Site Plan Approvals, and Variances, are reviewed and approved by the Planning Commission or Zoning Administrator. The proposed TZC amendments will not change this process. 75A-3 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 4 PUNt6W O[F[PMVRS MRIGB IF AFN¢V ProCESf OVFR-rNE{O¢NIERRE m ............ BYWCNr............ 9'VYS W iAHf ZA AvvuwloxwwunuxcF WIRIMPl1(A9LESLWMRM ,wPfNVAI.WnwFm R NNG PEmvrE els OEVELOPM TIX REVIEV ............................................ WDIK EiI¢WR ACVDN.................................................... AIWORq(FPiIONi CW ArmsrR115Ff F%FFGORAIOGFIUPONS AWOJIGIIONSlO1WW5R SFIECtFUC18U5F5 V.VOUiCFS ZIXIINLCOCF PARC¢µfPy rRACF AUPs Arnmrnsrox¢rawc FSIGPw¢s m'¢uwxus LFNFPRLPWIAMFIiWFNR 2CN..3MVR PUNNIN4RN9US PIINwHGCCFAkisWrcN Kgm ]SYIN¢ roEAL APGP(.LL E RPP �AE pwll CFss Figure 3. Transit Zoning Code Decision -Making and Review Process Summary of Proposed Transit Zoning Code Amendments: The proposed amendments include changes to building heights, off-street parking options, parking driveway standards, open space standards, massing, and setbacks in certain areas of the TZC. These amendments are as summarized below: Building Height— Lined Block Building Type Sub -district Impacted: Downtown (DT) sub -district Building Type Affected: Lined Block Proposed Change: Increase maximum height of Lined Block Buildings from 5 stories to 10 stories in the DT sub -district. Currently, the DT sub -district allows a maximum of 10-stories for a Flex Block building type and a maximum of 5 stories for a Lined Block building type. Examples of each of these buildings types are illustrated below (see Figure 4). The Flex Block and Lined Block are very similar building types. Therefore, staff is proposing a maximum of 10-stories for the Lined Block building type, which is consistent with the 10-story maximum height already allowed for the Flex Block building type. 75A-4 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 5 Figure 4. Flex Block Building Type (Left Image) and a Line Block Building Type (Right Image) By increasing the Lined Block building type height to 10-stories, the TZC would maintain the existing ten -story building height limit, but would allow additional types of buildings to be 10-stories in height. The TZC has previously established that Lined Block and Flex Block building types fit well in the DT sub -district, while other building types such as the Tower on Podium building type may be too large to fit on the small downtown blocks. Off -Street Parking Options — In -Lieu Options and/or Park -Once Program Sub -district Impacted: Transit Village (TV), Downtown (DT), Urban Center (UC) sub -districts Proposed Change: Allow required residential guest and nonresidential parking standards to be met by any combination of the following: • On -site parking • Participation in a Park Once Program • Payment of an In -lieu parking fee. Currently, the TZC requires developments in all sub -districts to meet their parking requirements on site. The residential parking requirement of 2 spaces per unit must be provided on -site. However, non-residential and residential guest parking standards in the Transit Village and Downtown sub- district can be met by participating in a Park Once Program and paying a parking in -lieu fee. Both programs have not been defined or established and will require review and approval by the City Council prior to implementation. Parking in -lieu fee programs allow applicants for development projects to pay a designated fee (or "in -lieu") instead of providing off-street parking spaces ordinarily required by the TZC. The purpose of an in -lieu program is not to impose an additional fee or burden on development, but to provide an alternative for projects having difficulty meeting minimum requirements on -site due to space constraints, financial feasibility, or both. Alternatively, a Park -Once Program allows people to park their car once and circulate throughout a downtown via transit or by walking. This program encourages utilization of existing parking structures, enhanced pedestrian mobility, and business viability. The proposed amendments to the TZC would expand the future parking requirement options through a combination of onsite parking, paying an in -lieu fee, and/or participating in a Park Once 75A-5 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 6 Program. This means that an applicant would be able to satisfy guest or non-residential parking requirements by providing onsite parking or by paying an in -lieu fee, and/or participating in a Park Once Program, if these options were adopted by the City Council. In addition, the amendments would extend the parking options currently allowed in the Transit Village (TV) and the Downtown (DT) sub -district to the Urban Center (UC) sub -district. At this time, the amendments are not proposing to establish either parking option program. Once developed, staff will bring a Parking In -lieu Fee Program and a Park -Once Program to the City Council for review and adoption. The City Council will be the final authority for considering and approving the use of the in -lieu fee alone or in combination with a Park Once Program to satisfy on -site parking requirements for individual projects. Off -Street Parking Options — Historic Buildings Sub -district Impacted: Urban Center (UC) sub -district east of Minter Street Buildings Impacted: Buildings or structures listed on the Santa Ana Register of Historic Places, the National Register of Historic Places, or within the Santa Ana Downtown Historic District Proposed Change: Exempt designated historic structures in the UC sub -district east of Minter Street from providing additional onsite parking The TZC currently exempts historic buildings within the Downtown (DT) sub -district from having to provide new parking if the building is converted to a new use, as long as the building is not increased in size. The proposed amendment would expand this exemption to apply to existing and future designated historic buildings located within the Urban Center (UC) sub -district, which is adjacent to the DT sub- district. The proposed amendments would affect approximately ten existing buildings that have been designated historic within the UC sub -district. These include the following buildings: • Dr. Howe -Waffle House —120 West Civic Center Drive • Grand Central Market—110-122 N. Sycamore and 190-117 N. Broadway • Phillips Block Building — 301-309 West Fourth Street • United Presbyterian Church—113-115 East Santa Ana Boulevard • Smith -Tuthill Funeral Parlor —518 North Broadway • Grand Central Building —125 North Broadway • Knights of Pythias Hall — 420-424 North Broadway and 300-322 West Fifth Street • Zerman Building — 201 West First Street • Empire Market — 202-208 North Broadway • Episcopal Church of the Messiah — 614 North Bush Street 75A-6 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 7 Parking Driveway Standards Sub -district Impacted: Transit Village (TV), Downtown (DT), Urban Center (UC), Corridor (CDR), Urban Neighborhood 2 (UN-2), and the Urban Neighborhood 1 (UN-1) sub -districts Proposed Change: Allow administrative approval of driveway widths to meet Fire Protection and Trash Service Requirements. Currently, the TZ requires 1-way driveways to be within 8 to 12-feet wide and 2-way driveways to be within 20 to 25-feet wide. However, on urban sites trash and fire trucks can have difficulty maneuvering within the maximum 25-foot driveway permitted by the TZC. The proposed amendments would modify the TZC text to allow staff to approve alternate driveway widths to satisfy Orange County Fire Authority (OCFA) and/or refuse collection requirements on a case -by -case basis. The amendment would provide administrative relief in the event that driveways need to be constructed wider than what the current code allows, and would create flexible options to provide access to parking structures and refuse collection areas in a single, co -located location within a development. Upper Story Setback — Downtown (D7) Sub -District Sub -district Impacted: Downtown (DT) Buildings Impacted: Buildings with more than 6 stories Proposed Change: Eliminate the 100-foot setback The Downtown (DT) sub -district requires a 100-foot setback from the property line for portions of buildings above 6 stories. However, many lots in the downtown area have a lot depth of only 120 feet and blocks within the DT sub -district have average depths and widths of 250 feet by 250 feet. This 100-foot setback requirement from the public right-of-way severely limits development potential and building design. The proposed amendment eliminates the 100-foot setback requirement for portions of buildings over 6 stories tall. This amendment would establish a development standard that allows lots with only 120-feet depth to be redeveloped with more practical designs. Lot Width and Depth Standards and Text Amendments Sub -district Impacted: All Buildings Impacted: Flex Block, Lined Block, and Stacked Dwellings Proposed Change: Establishes a Minimum Depth for Flex Block, Lined Block and Stacked Dwellings of 100-feet The TZC currently specifies minimum lot depths of at least 130 and 170-feet, which exceeds the typical lot depths of 125-feet currently found in the downtown area. The proposed amendments would modify the development standard to specify a minimum 100-foot lot depth for Flex Block, Lined Block, and Stacked Dwelling building types. Specifically, the Flex Block minimum lot depth would be amended from 130 to 100-feet, the Lined Block minimum lot depth from 170 to 100-feet minimum, and the Stacked Dwellings minimum lot depth from 130 to 100-feet minimum. These amendments would create a more realistic development standard that addresses current lot sizes and shapes in the downtown area. In addition, it would provide additional standardization of TZC development standards by eliminating internal inconsistencies within the plan. 75A-7 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 8 The TZC also specifies the minimum lot dimensions in multiple sections. The proposed text amendments would modify each building type's subsection to refer to the lot width and depth standards in Table BT-1, Permitted Building Types and Lot Depth and all other references to minimum lot depth throughout the document. This change would ultimately reduce opportunity for inconsistencies among multiple pages and code sections. Open Space Standards Sub -district Impacted: All Buildings Impacted: Flex Block, Lined Block, and Stacked Dwellings Proposed Change: Allows opens space areas to be located in the front, side or rear yard areas. The TZC specifies that required open space areas for certain building types may only be located in the rear or side yard areas. The proposed amendment would modify the development standard to allow construction of open space areas on any side of the building, including the front. This amendment would allow development of open space areas along the front of buildings and would provide greater public benefit, visibility, and security of open space areas when located at the front of a building. Massing Standards Sub -district Impacted: Downtown (DT) Buildings Impacted: All Buildings Proposed Change: Allows opens space areas to be located in the front, side or rear yard areas. The TZC requires that Flex Block, Lined Block, and Stacked Dwelling buildings become increasingly smaller in area as they become taller in height. Between 3 and 5 stories the buildings may only be 75-80 percent of the ground floor's volume; and portions above 6 stories may only be 30-40 percent of the ground floor's volume. This requirement results in buildings with a bulky base that steps back progressively with height, similar to an Aztec pyramid. The proposed amendments would modify the development standard to allow massing of 85 percent of the ground floor's volumes for buildings containing 3 or more stories. This amendment would create more realistic development standards that take into account the downtown area's smaller -than -average lot depths. In addition, the amendment would account for engineering and design challenges of buildings when step -backs are required on upper levels. ENVIRONMENTAL IMPACT In accordance with the California Environmental Quality Act, the proposed project is exempt from further review per Section 15061(b)(3). Environmental Review No. 2019-35 will be filed for this project. This exemption applies to projects covered by the general rule that CEQA applies only to projects that have the potential for causing a significant effect on the environment; where it can be seen with certainty that there is no possibility that the activity in question may have a significant effect on the environment. The activity would be consistent with Final EIR No. 2006, 75A-8 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 9 prepared for the Transit Zoning Code (SD No. 84) and certified by the City Council on June 7, 2010, through Resolution No. 2010-024. STRATEGIC PLAN ALIGNMENT, AND PUBLIC NOTIFICATION & COMMUNITY OUTREACH Strategic Plan Alignment, and Public NotificatidWA Community Outreach Strategic Plan_ Alignment7�'. Approval of this item supports the City's efforts to meet Goal No. 3 - Economic Development, Objective No. 2 (create new opportunities for businessrJob growth and Goal(s), Policy or encourage private development through new General Plan and Zoning Ordinance Policies policies) and Goal No. 5 - Community Health, Livability, Engagement & Sustainability, Objective No. 3 (facilitate diverse housing opportunities and support efforts to reserve and improve the livability of Santa Ana neig hborhoods). Public Notification & Community Outreach The proposed amendments are limited to the Transit Zoning Code boundary area. The TZC is not located within the boundaries of any neighborhood associations. However, the adjacent Downtown and Lacy Neighborhood Association representatives were contacted and informed of the proposed amendments. In addition, a notice was published in the Orange County Register. At the time of this Required Measures printing, no correspondence, by phone, written, or electronic, has been received from any members of the public. Furthermore, no public comments or input were received during the adjourned regular Planning Commission meeting on May 14, 2019. Newspaper posting was originally published in the Orange Newspaper posting County Reporter on May 24, 2019. The item was continued from the June 4, 2019, City Council. FISCAL IMPACT There is no fiscal impact associated with this action. 75A-9 Zoning Ordinance Amendment No. 2019-03 — Transit Zoning Code Amendments July 2, 2019 Page 10 STRATEGIC PLAN ALIGNMENT Approval of this item supports the City's efforts to meet Goal No. 3 - Economic Development, Objective No. 2 (create new opportunities for business/job growth and encourage private development through new General Plan and Zoning Ordinance policies) and Goal No. 5 - Community Health, Livability, Engagement & Sustainability, Objective No. 3 (facilitate diverse housing opportunities and support efforts to preserve and improve the livability of Santa Ana neighborhoods). Minh Thai Executive Director Planning and Building Agency Exhibit: 1. Draft Ordinance 75A-10 EXHIBIT 7 LS 7.2.19 ORDINANCE NO. NS-XXXX AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA ANA ADOPTING ZONING ORDINANCE AMENDMENT NO. 2019-03 AMENDING SECTIONS 41- 2010, 41-2011, 41-2012, 41-2013, 41-2014, 41-2015, 41- 2022, 41-2023, AND 41-2024 OF THE SANTA ANA MUNICIPAL CODE IN THE TRANSIT ZONING CODE/SPECIFIC DEVELOPMENT (SD) NO. 84 ZONING DISTRICT TO MODIFY HEIGHT, MASSING, OPEN SPACE LOCATION, DRIVEWAY STANDARDS, LOT DIMENSIONS AND AMENDING VARIOUS OPTIONS TO SATISFY REQUIRED PARKING THE CITY COUNCIL OF THE CITY OF SANTA ANA DOES ORDAIN AS FOLLOWS: Section 1. The City Council of the City of Santa Ana hereby finds, determines and declares as follows: A. Various sections of Chapter 41 (Zoning) of the Santa Ana Municipal Code (SAMC) have been revised periodically over the last several years to respond to changes in development, to adopt new permitting procedures, and to comply with changes to State and Federal laws. In a continuing effort to establish high -quality development standards and to create a user-friendly environment for residents and the business community within the City, the Planning Division is proposing revisions to various sections of Chapter 41 (Zoning) of the SAMC specifically found in the Transit Zoning Code (Specific Development No. 84). B. After a thorough analysis of the current code requirements in the City, staff identified several sections of the code for amendments necessary to ensure clear, uniform, and legally consistent regulations that are practical for the City and developers to implement through high -quality and safe building designs. The proposed amendments will enable the City to implement a regulatory framework that protects the health, safety and welfare of the City and limits undue strain on homeowners, business operators and developers. C. At its adjourned regular meeting on May 14, 2019, the Planning Commission held a duly noticed public hearing and voted to recommend that the City Council adopt Zoning Ordinance Amendment No. 2019-03. D. At its regular City Council meeting on June 4, 2019, the City Council by a vote of 6:0 continued the public hearing for Zoning Ordinance Amendment (ZOA) No. 2019-03 for 30 days. Ord. NS 2019-XXXX Page 1 75A-11 E. The City Council, on July 2, 2019, held a duly noticed public hearing on this zoning ordinance and amendments, and has considered all testimony presented thereto. Section 2. The proposed ordinance has been reviewed with respect to applicability of the California Environmental Quality Act ("CEQA") and the State CEQA Guidelines (California Code of Regulations, Title 14, Section 15000 at seq.). The project is exempt from CEQA as it can be seen with certainty that there is no impact on the environment [Section 15061(b) (3)] and a Notice of Exemption will be filed upon adoption of this ordinance. Section 3. Sections 41-2010, 41-2011, 41-2012, 41-2013, 41-2014, 41-2015, 41-2022, 41-2023, and 41-2024 of the Santa Ana Municipal Code in the Transit Zoning Code/Specific Development (SD) No. 84 zoning district are hereby amended and attached hereto as Exhibit A and incorporated by reference as though fully set forth herein. Section 4. If any section, subsection, sentence, clause, phrase or portion of this ordinance for any reason held to be invalid or unconstitutional by the decision of any court of competent jurisdiction, such decision shall not affect the validity of the remaining portions of this ordinance. The City Council of the City of Santa Ana hereby declares that it would have adopted this ordinance and each section, subsection, sentence, clause phrase or portion thereof irrespective of the fact that any one or more sections, subsections, sentences, clauses, phrases, or portions be declared invalid or unconstitutional. ADOPTED this day of 2019. APPROVED AS TO FORM: Sonia R. Carvalho City Attorney By:Ii— Lisa Storck Assistant City Attorney Miguel A. Pulido Mayor Ord. NS 2019-XXXX Page 2 75A-12 AYES: Councilmembers NOES: Councilmembers ABSTAIN: Councilmembers NOT PRESENT: Councilmembers CERTIFICATE OF ATTESTATION AND ORIGINALITY I, NORMA MITRE, Acting Clerk of the Council, do hereby attest to and certify that the attached Ordinance No. NS-XXXX to be the original ordinance adopted by the City Council of the City of Santa Ana on , 2019, and that said ordinance was published in accordance with the Charter of the City of Santa Ana. Date: Acting Clerk of the Council City of Santa Ana Ord. NS 2019-XXXX Page 3 75A-13 CITY OF SANTA ANA SPECIFIC DEVELOPMENT NO.84 TRANSIT ZONING CODE 13 MAY 2019 Prepared by. Moule b Polymides Architects and Urbanists for Cityof Santa Ana 75A-14 ?f R A N.S I T ZONING CODE :Table A. Contents and Organization I TABLE OF CONTENTS AND CODE ORGANIZATION This Code Is organized as Identified below: 00 Purpose and intent 13 01 Applicationof 13 Article 013 organization 13 03 Nonconforming 1:3 building and uses 03 Affordable Housing 1A Develoment Incers- lives 0a The Industrial over- 1A lay Zone IFDZ) 05 AppOadon for Dls. 1:5 cretionaryApproval 1 A Permitting Process 1d6 1 Bs Revlew Authority and 1:6 Permit Types TABLE A: CONTENTS AND ORGANIZATION Division 2. Divison 3. flegulating Plan Urban Standards by Zones El Zones Established 41-2006 Zones Established Figure It: Regulating Plan 41-2007 Uses Permitted 41-2000 ope2tionalStan- dares Building and Parking Placement 3:1 Building Height and Profile, Encroachments, and Parking Summary 41-2010 Tramit Vlllage(TV) 33 Zone 41-2011 Downtown(OT)ZOne 3A; 41-2012 Urban Center(UQ 35 Zone 41-2013 C oIdar(CDR)Zone. 3:6 41-2014 Urban Neighbarhoad2 3:1 (UN 2)Zone. 41-2015 Urban Neighborhood l 3d1 (UN 1) Zone Building Types, 4:1 General Provisions 31-li Permitted Building 4.1 Types 5 General Require- 43 mentsfor All Types BT-B: Permitted Height 43 by Story Type BT{Determining 4:4 Permitted Building Sm. lT4.Open Space Area 4:4 it Toweron-Podium 45 2 Flex Block 4.7 Lined Block 49 Stacked Dwellings 4:11 t5 Hybrid Court 4:13 Courtyard Housing 4:15 IZ Live/Work 4:17 Rowhause 4.19 Tuck-0ndar Housing k21 Bungalow Court 423 it Dupt x Tdplex.and 425 Quadplex 12 House 49 Frontage Types 429 FF-I: Frontage Types 4:29 Permitted by Zone Arcade Frontage 431 15 Gallery Frontage 431 Shopfront Frontage. 431 11 Forecourt 433 Stoop 433 Frontyard/Porch 433 1:1 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 04 City of Santa Ana, California 7 5A-1 5 Division 4. Architectural Standards, coma 41-2040 Architectural Ssandirdsi 435 E Style, Massing, Pmpor- Nom, and Materials Table ASA Permitted Architec- 435 [oral Styles by BuiMirg Type .fuel Style Guidelines 435 •Main Street 437 Commercial • Mission Revival 439 •Art Deco 4,41 •F01kVicmrian 4:43 •CraWman 4AS •California 4:47 Contemporary Table A: Contents and Organization, cont'd CONTENTSTABLE A: AND ORGANIZATION Division 5. On -Premise Signs 41-2010 Purpose and Intent i �41-201 Application of Division 5:1 General Provisions and 5:1 �41-2052 definitions 141-2053 Sign Standards 5:1 Table l: Permitted Sign Types by 52 Frontage 41-2054 Sign Design 53 41-2055 Sign Maintenance 33 41-2056 Major Development 53 Identification Signs 141-2057 Preservation of&Ist- 53 Ing Historic Signs 141-2058 Building Identification 53 Sign l 41.2059 Building Directory SA Sign 41-20W Service EntryWall Sign SA Special Sale Sign 5:4 �41-2061 41-2062 Credit Card Signs 5:4 41-2063 Construction Signs SA �41-2064 Window Signs 5:4 I' Table SO Allowed Sign Types: 55 f Illustrated Table 2: Permitted Sign Place- 55 event Table 3: Requirements by Sign 5:7 Type Street Network Concepts 'Subdivision Guidelines Bbcks and Streets 6:1 . purpose •Guidelines Table 6A: Block Guidelines 6:1 Table 66: 10ustrative 62 Sequence Street Network Concepts i Purpose 63 • Street Alignment and Adjustments i• New Street Types 1 Figure 7-1: Street Network 63 I Plan Table 7A Concepts for Spe- 65 ci&Streets L-_--- _ _- Division 7 Definitions I 41-2W0 Defintions 7:1 TRANSIT ZONING CODE 12 SPECIFIC DEVELOPMENT 84 7 5A-16 City of Santa Ana, CallforNa (TRANSIT ZONING CODE :General Provisions ARTICLE XIX. THE TRANSIT ZONING CODE, SPECIFIC DEVELOPMENT NO.84 Division 1. General Provislons Sec 41.2000. Purpose and Intent (a) This article provides detailed regulations for development and land useswithin the specific development area, and describes how these regulations will be used as part of the Gtys development review process. This article is Intended to provide for the Integration of new development and rehabilitation of exist- ing structures with new and existing public transit infrastructure. This article will provldefor. (1) A mixture of development and open spaces that situates commerce work places residences and civic buildings within walking distance of transit and one another. (2) Seveb that meet the needs of many transit modes Including public Wnsn, pedestrians, cyclists and automobiles (3) Developmentthat Is maximally transit supportive. (4) New and remodeled buildings to work together to define the pedestrian. oriented space of the public streets to support and strengthen the existing character of the neighborhoods In which they arc located. (5) The repair and stabilization of the area's existing urban klmQ characterized by an Interconnected gridded street pattern and a mixture of architectural styles and uses, In order to support the successful expansion of public ton sit and Compatible development Sec 41-2001. Application of Article (a) The Transit Zoning Code as authorized by Chapter 41, Division 26, Section 41-S93 et seq, of the Santa Ana Municipal Code, is subject to the standards and regulations contained In this Amick for the express purpose of establish. Ing land use regulations and standards All other applicable chapters, artides and sections of the SAMC and any other regulations adopted by the Cry Council shall apply unless expressly stated or superseded by this Article. All terms contained herein shall be defined by the SAMC, unless specifically defined In this Article. (b) Proposed development inducting the construction, reconstruction or struc- tural attention of a structure, subdivbbns, and new land uses within the spe- dfic development area shall comply with all the applicable regulations estab- lished by this article. Sec 41-2001.5 Organization (a) Regulating Plan and Zones Established: Sections 41-2006 through 2008 defines the zones within the Specific Development (SD) boundarie; the par- cels Included within each zone, and describes, zone by zone, the standards for buliding placement, design. and use consistent with the permitted uses IdenU- red In Table 2A @) Use Standards: Table 2A Identifies the land use types allowed by the City In each of the Zones established by the Regulating Plan. A parcel within the Specific Development (SD) boundaries shag be occupied only by land uses Identified as allowed within the applicable zone and the type of City approval required by Table 2A. - (c) Urban Standards by Zone: Sections 41-2010 through 2015 regulates the fea- Nres of buildings that affect the public realm. The urban standards regulate building and parking placement. height and profile, and vary according to the parcelss zone applied by the Regulating Plan. Standards for hems not explicitly described in this section, Including but not limited M walls and fences, mechanical equipment, trash bin enclosures. heliport and helipad, underground utility, installation of dish antennas, loading areas, parking pot design standards, refer to Chapter41 ofthe Santa Ana Munkipal Code and the Otywlde Design Guidelines (d) Architectural Standards: Sections 41-2020 through 2039 regulates the man- ner In which Individual parcels and blocks are developed to create diverse and pedestriancrienmd development through the use of three main com- ponents (1)Sections 41-2020 Nuough 2032 building types (e.g. duplex, rowbouse, courtyard housing) (Z)Sections 41-2033 through 2039 frontage types (eg, front yard/porch stoop, arcade shopfrom) (3)Section 41-2040. (Table 43A) arNitectural styles (e-g, Main Street Commercial, Mission Revival. Art Deco Folk Victorian, Craftsman, California Contemporary). (e) Sign Standards: Section 41.2050 regulates all signaller within the SD bolmd- aim to be consistent with the character described for each Zone (f)subdivislon Guidelines: Establishes guidelines for the creation and mainte- nance of a finely gained and walkable network of blocks punctuated by Integral and varied open spaces (g) Street Network Concepts Identifies conceptual location and g udelines for the street network This section rprovides guidelines the rights4rwayalignment and width in plan and section with the corresponding detalls (h) Definitions: Sections 41-2080 dentifin and defines the terms used in this Code. 1:3 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 64 City of Santa Ana, California 7 5A - 1 7 1.0 -Applicability of Code, coni'd Sec 41-2002. Nonconforming buildings, structures and uses (a) A rionconforming building, structure or use shall comply with Article VI as modified as follows: (1) A Wilding or structure that does not conform to the architectural style or story height requirements at the time of the adoption of this Article shall not cause the structure to be nonconforming. (2) Sections 41681.1 through 41681A shall not apply to this Article. (3) Rehabilitation, enlargement or exterior structural alterations of any noncon- forming structure or structure occupled by a nonconforming use except for structures Occupied by single family and two-famly dweifnga, may be rehabilitated as follows: a. Rehabiliubonlimitedtoshucturalornomswct nlaltemtions without any building expansion Is permitted if.. 1. All dgnage on the structure and the site on which it is located shall be brought into conformity with the ssgnage requirements of this Chapter. 2. All outdoor storage shall be screened by a solid screen wall not to exceed 8 feet in heighL Outdoorstorage shall notexceed the height of the screen wall 3. There shall be no increase in the number of dwelling units unless the site on which the structure is located complies with the off-street parking and open space requirements of this Chapter. 4. Architectural massing, features and detailing shall be modified to bring the structure Into closer compliance with the architectural standards of this code, as deemed appropriate by the Executive Director of the Planning and Building Agency, or their designee. b. Rehabilitation may Include expansion when the total floor area of all expansion occurring in any five-year period does not exceed ten (10) percent of the floor area as it existed at the beginning of the five years, Provided that the following conditions are met I. All ssgnage on the structure and the site on which it is located shall be brought Into conformity with the requirements of this chapter. 2. There shall be no loading or unloading of vehicles between the hours of 10 pm and 7 am. 3. All outdoor storage shall be screened by a solid screen wall not to exceed 8 feet in height Outdoor storage shall not exceed the height of the screen wall 4. There shall be no enlargement which would intrude Into any required yard S. There shall be no enlargement which would result in a new noncon. formity with the requirements of this Chapter. 8. Off-street parking shall be provided in conformance with the requirements of this Chapter. 7. landscaping shall be Improved to bring the site on which the struc- ture Is located Into closer compliance with the landscaping require. ments of this Chapter, as deemed appropriate by the Executive Director of Planning and Building Agency, or their designee. 8. Architectural massing, features and detailing, shall be modified to bring the structure Into closer compliance with the archltectural standards of this Chapter, as deemed appropriate by the Executive Director of Manning and Building Agency, or their designee. (4) Rehabilitation, enlargement or exterior structural alterations of buildings occupied by single family and two-family dwellings Is permitted subject to the following: a. Structural alterations and additions may be made where the total floor area of all such expansions Occurring in a five-year period does not exceed forty (40) percent of the Floor space of the building as h existed at the beginning of said time, provided the number of dwelling units is not Increased; and no new non -Conformances with the requirements of this code are created. b. Structural alterations and additions which exceed forty (40) percent of the total floor area as it existed at the beginning of a five-year period; or remodeling which Involves the demolition of more than fifty (50) percent of the building shall be permitted; provided that the following conditions are met 1. Off-street parking shall be provided in conformance with the require. ments of this Chapter. 2. No new nonconformhies with the requirements of this Chapter are created. 3. A minimum ofeight hundred(800) square feet of usable, continuous, non{ront yard openspace, excluding driveways and parking areas is provided. Any open space with a minimum dimension of fifteen (15) feet by fifteen (15) feet shall be deemed continuous open space. c Where rehabilitation of a building Involves more than fifty (50) percent ofa building wall which encroaches Into a front or side yard setback and Is demolished or is structurally altered, the remainder of the building wall shall be demolished. Any subsequent building wag shall conform to all provisions of this Chapter. d. An existing two<ar gauge with a minimum dimension ofeighteen(18) feet by eighteen (18) feet exterior dimension shall be considered con. forming. e Remodel shall mean toreconstroctorto make overin structumorstyle, but shall exclude re -roof, window replacement exterior finish replace- ment and repair or similar modifications. Sec 41.2003. Affordable Housing Development Incentives. Any affordable housing proje¢ may use any or all of the following Incentives Pursuant to an Affordability Covenant Permit (a) Parking Design Incentive: Allows for tandem parking not to exceed 30 per. cent of the required parking per residential unit (b) Private Open Space Incentive: For purposes of meeting the private open space requirement the private open space incentive allows for encroach ment Into required front or side setbacks for porches that project from the main building facade up to 50 percent of the required setback, provided that the remaining setback area is not less than 5 feet (c) Density Bonus Incentive: The state density bonus law, (California Government Code sections 65915 through 6S918, as it may be amended from rime to time) allows developers who guarantee thata portion of their residential development will be available to low Income, very Iow4ncome or senior households to construct additional units beyond that permitted by the general plan land use element This Specific Development does not place a Emit on the numberof units allowed provided that the project com- piles with the specified limitations on height setback% Roe, area open space, massing and otherzcning regulations. a. For purposes of this section, the maximum density allowed slag be based on the highest number of the density range shown on table BT-1. b. All requests for density bonus shag follow the procedures and regulations established by Article )(VLL TRANSIT ZONING CODE 1:4 SPECIFIC DEVELOPMENT 84 7 5A-1 8 City of Santa Ana- California TRANSIT ZONING CODE : Applicability of Code, coned Sec 41-20114.The Industrial Overlay (WZ) Zone (a) The Industrial Overlay Zone "Z) Is applied to areas coned MI or M2 and occupied with an industrial use at the time or the adoption of this Article.The coning forthe IndMdual parcels shall be determined by Sectional District Map number 7-5-9 as it appeared on May 1, 2010. (b) The WZ allows the MI and M2 regulations to apply to said parcel until such time as the property comer applies to modify the mning district The Regulating Plan Identifies the boundaries of the applicable mning district lie. Transit Vllliage, Urban Center, Condor, Urban Neighborhood 1 or Urban Neighborhood 2) within the Transit Zoning Code. (d A property owner may apply to develop the parcel consistent with the app8- able zoning district within theTansit Zoning Code.The applicant shall Receive all the necessarydfe approvals Including, the approval ofthe ovedaymne site plan pursuantto Article 81, Division 28 priorto development (d)Theuses In the WZ shall be subject to the regulations ofthe M1 and M2 cones (SAMC 41, Article lq Divisions 18 and 19), as applicable. Sec 41-2005. Application for Discretionary Approvals (a) Site Plan Review shag mean specific development plan and shall comply with Sectors 41-593A through 593.6. Sections 41-593A through 593.6 shall only apply to structures over four (4) stories In height (b)Conditional use permits, variances and minor exceptions Conditional use permits variances and minor exceptions shall be subject to ArticleV, except for the permit thresholds for minormceptions shall be as Identified In Table 18. 1:5 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 7 5A - 1 Q V vuxxacoasavevozanuvat Bn%wveoa5s 1 OIER-1HE(MRRfAISV1IY I ---- ............ n nnn......... vlesxu%Pu Avnxnrs+xcavu.v� Wm1aVNYAHESGXMPnS IFMWN aVMGmT vuxxHa may WaQss Applicability of Code, cont_d DEVFWPlAEMPtAN u�gw Acomcacamiunw muZZ TABLE IB: REVIEW AUTHORITY ANDPERMITTYPES'151 cc Chy Colnecli PC Planning Commission HRC Histodc Resource Commisdon ZA Zaning Administrator Planun: ExecuDve DvectaA M cwtheirdesignee [1] Review Authority The Resew Author y Men- tified in Table Illhas the II. Variance aumodry to grant approval Requests that exceed the Ilm- of, onmake a recemmerda- ItsIdenUfieel in Table 10. but Non to the rat highe Review that are withm the Intent of Authonry on The permH types this code. are to be processed as desnibed. byPlanwgwimarecommen- dation for resew and anion R1 Development Approval by the Planning Commission, Applicatloiu that she contis. subject to the mc,iisM find. tent with the applicable sun. Ing, in The SA dads of this code and as M- ther permitted by Table ZA, N] CaleAmesdmmt aretubeapproeedadmWsta. Approval of a Code gvetp Amendment, subject to Me retched findings In the [3110odificadonofSUMasds S)WIr daT be considered by L Minor Ecceptsos the Oty Council upon recom. Upon determination by mendatlon by the Planning Nanning chat the Minns, at Commissbn. authalted by TaNe 1%and Is consistent much the required [51 Wag Fees findings In the SAMC. the Application submimed pursu. Identified standards may ant to Thus code shall be filed be modified by The Zoning per the Nanning Division's Achablixeto, procedures and pmces5ing fees In effect at me time of apPilcation MEAL I I xvvawu Aumwmr mu ary munn IEG4f PP0[FSS I I FFPI'JIxIME(5 yvua Punning w Hannirg Commiufon VoluntaryLot Meryer Lend Use Certificate For'LUC uses In Table ZA Unit use S buBdbg type Inter. — Mina, aceptl na[3) maximum minor (allmdt mx arethe orexaption permlttedl (Hlayldm/Depth INb w Sesbxb Is% 0)Bu3Sg Height Ig% NI Butweg Siulwanhp 15% Hlmiwway Aoaer IS% 09open5pere Ana IS% m Sign HdghVWdm loss, wwaataMFenes If% CondlUonal Use Perom for CUP' uses In Table ZA, as aum dud by me Nanning Commisslm Conditional UU Permit fo,CUP'uses In Table 30. exorytu nosed above itive Tray Map >apasceb Varance reLlueHbin encess of firma estab. limed br mina, exception I Hbtorlc StruRwes 75A-20 TRANSIT ZONING CODE IS SPECIFIC DEVELOPMENT 64 City of Santa Ana, California T R A N S I T Z O N I N G C 0 D E : Regulating Plan and Zones Establshed Division 2. Sec. 41-2006. Zones Established (A) Purpose. This section establshea the mnes applied to property within the pan area by the Regulating Plan. The Regulating Pan divides the plan area into Separate cones that are based on a transact of intensity within the plan area that ranges from the most urban types of development and and use to the least urban types, with most mnes providing for a significant mixture of and uses within them. This approach differs from conventional zoning maps that tyDically divide cities into zones that rigidly segregate residential, commercial, industrial. and intutw tlonal uses into separate areas, and thereby require residents to drive for nearly all daily activities. The use of zones based on development intensity (instead of and use zones) as the spatial basis for regulating development directly reflects the functions of, and interrelationships between, each part of the plan area. The zones also effectively Implement the City's urban design objectives for each part of Me plan area, to establish and maintain attractive distinctions be!N een each zone This Is why some parcels are coiled with more than Orle corm. In such cases, the zoning is divided along a clear boundary such as the middle of A block. The zones of this Regulating Plan allocate archltMuol types, frontage types, and land uses within the plan area, as well as providing detailed standards for building placement, height and profile. The diagram to the right identifies the 9 zones applied within the plan area as they elate to existing rights ofv ay and parcels. (b) Zones established. The following zones are applicable to this specific plan, and applied to property within the boundary as shown on the Regulating Plan. (1) Transit Village (TV) Zone. The Transit Village zone is intended to provide standards for compact transit - Supportive mixed-use/residential development This zone is characterized by a wide range of Wilding' intensity, including mixed -use tower -on -podium Wild- ings, flex blacks, liners, stacked flats, and courtyard housing. The zone accom- modates retail, restaurant entertainment, and other pedestrian -oriented uses at street level with offices and flats above in the mixed -use building types, at high intensities and densities. The landscape palette is urban, with shading and accent street trees in parkway strips along Santa Me Boulevard, and In sidewalk tree wells where on -street parking is provided. Parking is accommo- dated on -street in structures with liner buildings and underground. (2) Government Center (GC) Zone. This area accommodates a wide variety of civic uses, including Federal, State, and local govemmeM offices and services, Nbraries, museums, community cen. ters, and other civic assembly facilities. Building types vary According to their public purpose, are programmed by the various government agencies for their specific sites, and therefore arc not coded by the Transit Zoning code RDaaA and SD $48), The landscape style is urban, emphasizing shading street trees in sidewalk tree wells, and in landscaped public plazas. (3) Downtown (OFT) Zone. This zone is applied to the historical shopping district or Santa Ana, A vrtak pedestrian -oriented area that is defined by multi -story, urban building types (flex blocks, live+vurk stacked dwellings, and courtyard housing In the Downtown edges) Accommodating a mixture of retail, office, light service, and residential uses. The standards of this zone are intended to reinforce the form and character represented by pre -World War II buildings and recognized as a National Historic Dlstrkb through restoration, rehabilitation, and context - sensitive infiB The standards also facilitate the replacement or improve- ment of postrar development that eliminated the pedestrian orientation of various downtown blocks (for exampa, parking structures with no features of pedestrian interest along their entire lengths). The landscape style is urban, emphasizing shading and Accent street trees in sidewalk tree wells. Parking is accommodated on -street and may also be in structures with liner buildings, underground, and within block centers in surface lots not visible from streets. N) Urban Cerstez (UC) Zane. This wine I applied to the area surrounding the Downtown, which serves as a transitional area for the surrounding lower intensity neighborhoods and to other areas when mixed -use and multi -unit residential buildings create a pedestrian -oriented urban fabric. The zone provides for a variety of non-res- idential uses and a mix of housing types at medium intensities and densities. Besides Accommodating community serving businesses, this zone may also serve the daily convenience shopping and service needs of nearby residents. Building types include mixed -use Flex Blocks, stacked flats, live work, row - houses, and courtyard housing. The landscape is urban, emphasizing shading street trees in sidewalk tree wells. Parking is accommodated on -street and may also be in structures with liner buildings and underground in areas adjacent to the DT zone, and in surface lots away from street frontages. Rpn Z.1 Regullating Plan with Exiting sBOW I�1��i a . 250 500 1(100R O 71 (5) Candle (CDR) Zone. This zone is applied to properties fronting existing commercial corridors and provides standards to improve pedestrian -orientation in a transit -supportive, mixed use area. Mixe fuse flee block and live -work building types arc at or new the sidewalk and Accommodate street level retail, service, and office uses, with office and residential above. The landscape style is urban, emphasong shad- ing street trees in sidewalk tree wells. Parking is accommodated on -street, and in screened surface lots between buildings, or away from streets, with no more than half the site frontage occupied by parking. (6) Urban Neighborhood 2 (UN-2) Zone. This zone is applied to pnmanly residential areas intended to accommodate a varety of housing types, with some opportunities for live -work neighborhood - serving retail, and cafes. Appropriate building types include single dwellings, duplexes triplexes and guadplexes courtyard housing, cowl ouses. and hn, work. In some areas, the more Intense, hybrid court building type is allowed where additional intensity is warranted while maintaining compatibility with neighboring properties I. Regulating Plan). The landscape is appropriate to a neighborhood, with shading street trees In parkway strips, and shallow - depth landscaped front yards separating buildings from sidewalks. Parking is on -street and in garages located away fern street frontages. (7) Urban Neighborhood 1 (UN-1) Zone. This zone is applied to existing primanly residential areas and is intended to strengthen and stabilize the low Intensity nature of these neighborhoods. zU TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of SOMA Ana, California 7 5A-2 1 Regulating Plan and Zones Established, cont'd key Appropriate building types include single dwellings, duplexes, tri- Transit Village (W) ■ Specific development Boundary plexii and quadplexes, and live -work. The landscape Is appropn- ate to a neighborhood, with shading street trees in parkway grips Government Center(GQ IU Industrial Overlay Zone (I-0Z) and landuaped Front yards separating buildings from sidewalks. Parking is on -street, and in garages located away from street front- Downtown (DT) ■ WZ-MI ages. Urban Cents (lK) I-0Z#li (8) Industial Overlay (I-OZ)Zone, Thel-0Z is applied to areascunently zoned M l or M2, arts occu,id Corridor (CDR) ■ with an industrial use, to allow the types of land use activity and development permitted by existing Mt and M2 zoning to continue Urban Neighborhood 2 (UN-2) until such time that the owner chooses to apply the new zones a I rxxi ahe'e Hybrid identified in Figure 2,1. In order to determine if the M I or M2 unit c.opeban°wea use activity and development apply to a particular parcel. the IOZ is Urban Neighborhood I UN-p further identified as FOZ-M1 or POZ-hQ Until the property owner applies to modify the zoning district, property in the FOZ shall be Open Space (0)nl ■ regulated by the pronsoms of the Mt and M2 zones (SAMC al, Article III, Dwi... s 18 and 19), as applicable. (9) Open Space (0) Zone. This zone identifies areas reserved for community parks and other open spaces. Allowable structures In this zone are limbed to those (11 Identified, but not regulated by this Cade. necessary to support the specific purposes lathe particular open It . to Chyno.bements as identified In space area (eg.. SpOrt-court enclosures and multi-wir oie build- SAWChaplw41. ings in active parks, and trails within passive parks). TRANSIT ZONING CODE ZZ SPECIFIC DEVELOPMENT as 75Ann City of Santa Ana, CagfomM TRANSIT ZONING CODE Uses Permitted Sec. 41-2007. Uses Permitted. Table 2A - Use Standards (A) Allowable Land Use Types. A parcel ot build- ing within the Specific Development area shall Permit Required by Zone be occupied by only the land uses allowed by Land Use Type the table entitled Use Standards (hereinafter Use Standards Table) within the rone applied to UC UN-2 UN-1 the ske by the Regulating Plan . refer to Key to one Symbolsd m ng page tor mine escrlptronan usenod s (b) Garage sales arc allowed in compliance withSection 41-193. RESIDENTIAL (c) Temporary outdoor activities are allowed in compliance with Section 41-1955. Live -Work Usel Joint Wirg-working quarter P(2) P(2) P(2) P(2) CUP CUP (dl Youth amusement rides are permitted in Care Homes CUP CUP CUP CUP CUP CUP compliance with Section n-366 forC1 districts. Single Dwelling - — — -- P P (e) Drive -through facilities shall not be permit- ��mily Dwellings - - NO I Pill , PIU Ply IF P red. Sec.41-2008. Operational Standards MCREATION, EDUCATION AND ASSEMILY (A) All Property shall be maintained In A safe, sanitary and amactive condition Including, but Commundy, assembly j P(1) P(1) P(1) P CUP CUP not limited to, structures, landscaping, parking Health/fitness facility I IF P P P CUP — areas, walkways, and trash enclosures. - Lioary,museum P P P P P CUP (b) All business xtivdies shall be conducted f Schools P(D P(1) P(1) P CUP CUP and located within an enclosed building, except as allowed by Section 41-195 of the SAMC SWdio P P I P I t:U► CUP and except that the following business activi- theater. cinema or performing arts ► P ► 1 — ties may be conducted outside of an enclosed -- �Cammercial building. R"reatium (Indood- CLIP M CW — — (1) Newsstands (2) Flower Stands (0 There shall be no manufatturing, P—Att ling, compounding, assembling or treatment of any RETAIL. material or product, othm than that which is clearly incidental to a particular retail and ser- General retail, except with any of the following features ► -► P P P(2) — vicegeneralmtemrise. and where such goods Floor area over 20,000 per tenant CUP CUP P — CUP — are sold on the premises. — Ba4ng establishments P P P P P(1) — (d) There shall be no work inside of a structure Auto or motor vehicle service — — ► IF — that generates noise that exceeds 60 d8 CNEI measured At the..mmin wall of the unit. (A) Storage of goods and supplies shall be lim- ited to those sold at retail on the premises or utilized in the course of business. SERVICE GENERAL (f) Public utility structures including electric Banquet facility/catering-sus. to41. 199.1(a)tMo�gh(d) CUP CUP CUP T cup") =L^I distribution and transmission substations shall Child day care- more than 8 and up to 14 children P(3) P(3) P P LUC(2) LUC be screened by a sulk wall at least eight (8) feel high, except as restricted by Sections 3645, Child day care center P(3) P(3) P P CUP CUP 3646, and 3612. Mull day care center -subject to 41.1"Z of the SAMC P (3) P (3) P P P -- (9) Any activity permitted shall be conducted Hotel, end. transient residential hoN AM long term stay P P P P --- in Loth a manner as not to have a detrimental Mortuaries, fun" homes — — CUP P -- -- effect on penmar ed adfxmt Uses by reason of refuse matter, noise, tight or Vibration. Personal servka P P P P P(2) P (21 Personal services - restricted — — CUP CUP CUP — IN Small scale industry uses shall require a --- solid wall orfence not kssthan eight (8)feet In Tattoo/Body Art Establishments- subbed m 41.1993 of P P P P --- --- height along any rear or ske lot line. the SAMC -_ - (i) All business xtiviMs including, but not lim- ited to, compounding, processing, packaging Or assembly of anicka of merchanch. and treat- ment of products shall be conducted within a completely enclosed building. No ancillery vehicle maintenance or repair shall be allowed on sae. U) Loading areas shall not be visible from streets. tootling areas not facing A street shall be setback at lean mirty two (35) feet from the property line. 23 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT E4 AS lid City of SanAna, California 7 5A— /^/� / V Uses Permitted, cont'd Table 2A - Use Standards Permit Required by Zone Lantl Use Type N-2 UN 1 SERVICES -BUSINESS FINANCIAL -PROFESSIONAL tank financial services Business Support Service Chnic urgent care Doctor, dentist, chimprectoc etc, office Extended care I Professional / administrative service office SMALL SCALE INDUSTRY Artisan/craft product manufacturirsg Furniture and fixture manufacturing, cabinet shop Laboratory - medical - analytical Manufacturing -fight Media Production-oKkeccmrefronttype(oosourdsragel Printing and publishing TRANSPORTATION, COMMUNICATION, INFRASTRUCTURE Hekstops Parking facility -public a commercial Transit station or terminal I Public utility structure, excluding wifeless comunira- tion facilities MISCELLANEOUS Any structure over four (a) stories in height Businesses operating between 12 and ] am Akohollc beverage Wes or consumption Bey to Zone Symbds Transit Village Downtown Urban Center Rey (1) Use permitted only on second or upper floors, or behind retail or ser- vice ground floor use. (2) Permitted only as part of a vertical mixed use proleLt with upper floor residential (31 Permitted only as Part of a mixed use project with a commercial or residen- tial component P P P ► — P P P P P(2) P (2) CUP P — — P(p Pill P(l) P - I. P P P P CUP P(I) POI PC P P(2) P(2) CUP CUP CUP -- CUP-- P (3) -- P 131 -- -- -- - P(1) P(1) P -- -- P(3) 1P(3) — CUP --- _- P IF NO — - -- P(3) — to - ar - Nunn; SPR SPR Spit SPR SPR — CUP CUP CUP CUP CUP CUP CUP CUP CUP CUP CUP CDR Corridor UN_2 Urban Neighborhood 2 Urban Neighbofhond I P use is permitted subject to compliance with all appli- cable provisions the Santa Ana Municipal Code LUC use Is Permitted subject to the approval of a Land Use Certificate. CUP use is Permitted subjett to Me approval of a Conditional Use Permit SPR use is permitted subject to the approval of Site Plan Review. — use not permitted In particular zones. (k) No business activity that generates noise or vibration shall be Conducted between 900 Pm. and TW a.m. Monday through Friday and OW p.m. and 10W a.m. Saturday and Sunday. (I) Operational standards for automoble servking. (A No automobile servicing shall be con- ducted before 200 a.m. or he, aW p.m. Monday through Friday and before tOW a.m. or after aW Dre. Satruday and Sunday (2) All work shall be conducted Inside an enclosed structure. (3) Outdoor or overnight vehicle storage is not permitted. 75A-24 TRANSIT ZONING CODE 2:4 SPECIFIC DEVELOPMENT 34 City of Santa Ana, California TRANSIT ZONING CODE :Urban Standards by Zones Division 3. Building and Parking Placement, Building Height and Profile, Encroachments, and Parking Summary A. Requirements 1, Purpose. This Division identifies the standards and requirements for new build- Ings, or buildings to be modified, M each zone within the Code area to ensure that proposed development is consistent with the City's goals for building form, character, and quality within the Code area. The zones are organized by inten- sity from the most intense (TV) to the least intense( UN -I). Unless stated other- wise, all requirements arc expressed as 'minimums and may be exceeded (e.g., 2 parking spaces required and 3 provided) in compliance with all applicable provisions of this code and Chapter at. 2. Applicability. Each proposed improvement and building shall be designed in compliance with the standards of this Division for the applicable zone, except For public and institutional buildings, which because of Their unique disposition and application are not required to comply with These requirements and are reviewed by a special permit and procedures. 3. Requirements by zone. Each proposed building shall be designed according to the urban standards Identified per the zone In which she property Is located. B. Summary of Zones At right, in Table 3A, are the six zones (see Note below) organized in descend- ing Order accorddg to their role and intensity within the Code area and as they appear In this Chapter: -Transit Village (TV) • Downtown (DT) • Urban Center (UQ • Corridor (CDR) • Urban Neighborhood 2 (UN-2) - Urban Neighborhood I (UN-1) Note: the Government Center District and Open Space Zones are identified in this Code but regulated by the Santa Ana Municipal Code. Table 3A: ZONE SUMMARY OF STANDARDS Anaae r GaIWry v Shopi,om v rorecnun r Stoop 8uiW."Sedh", I In heel 1arY,nd Gtoi,I sme Steel 0 10 l 1. s,dr, yam a Re rrd Is Alley neon ram 3 111 Grand Ale -Mks ISaNmcwmn ROW Anode r Gauery Y Foreaourc _ Y Stoop Y BuINin95ehbr[k+ In Net Font yam o Side Sneet a10 nae yam o Re.F yard _ IS uNy re,nrwa I' Parking per DU ou/5g + Parking per DU DUI e o Sq Ft Fr liven or Sq Ft s4Ft Gwen Residential 3 015 Residential 2 0.15 ❑re -Wald 3 Live ..,k 2- A lid no I 1/a00 IrvLNufee wv - Non_R dent 1 1/aoo yes In-L irT yes - yes ppRPa@1 gygppilbl Rey WTabN 3A it shaded tear means not permmed' In the zone. means not applicable in the zone. (al Max Stories for A zonesrefer to the total number of stones permitted per Zone. The massing for all buddirgs are subject to sate and massinq staNads, as dexrlbed in Guilt Type Standards for each bhradirsg type section at -NM), as indicated In The example ti below. 3:1 TRANSIT ZONING CODE- SPECIFICDEVELOPMENTfa otes conunu on neat page City of S.Nts Ana. California 7 5A-2 5 Urban Standards by Zone, cont'd Intent ared Character of UC Zone Flex Bock 5 Lined Blrck s Stacked Dereltngs 5 Live-Woh I 3 TutkiMder Fadage Types Allowed (see Chapter 41 M staramsl Shopoord Y Faeroun Y Sloop Y Frontw d & Porch Y �auleNN smaaa ( Infeet Front Yard o Side Snees 0-I0 Side yaE 0 M yaM Is ABayAW )tad 3 P.Avy, per W/Sq a W or SqH Ft Wnt R¢sitlenlul l 0.15 beeWeekl 0.Is N nA Sid nri I Ir3CO Nli[uhs as Ini and Character of CDR Zone Duple.r rTri olex Duadplev Mouse Frontage Types Allowed bee Chapter 4Z for starartlsl Gallery Y Shopiront Y Forecourt Y R;;;'. $e1Whs ------------ to feet frontymd 5-ispl We5111, 0-101 We yam o Rear ard 15 11 I (SurAve - MM ls' hom Sundt[ MW. Intent and Character of UNZ zone Building Types Maz SIPrNSIaI (see Chapte 44J for=Is) I k 9ak AlYrllallle 3 TurR4RtM 5 per"ApaCourt Z 'Duplex/Triple,' 3 QudPlex House = 'Irl rve Xryuunnp Nanlwalx:xaa blYn Frontage Types All. (see Chapler4.2 for saiMamsl Shopfronl Y FOry, in Y Stoop Y Fonryard A Ponh _ Y Front ,it 10(n Intent and Character of UN Zone Buddlrtg Types I Max Stories (see Chapter 4.1 for Stara du x8lock -� L ted Stock Troves DeveRNs qubdd Court -=.nri Hoodn9 L- Work Srrtgalow Coua � Z Dupte✓rripN. ' i house j Frontage Types Alkawed (see Chapter 4 i for standards) Stoop Y Fr hand & Porch y BUIMIy SetbMs In leeF Front yard 20 Side Sneel 10 Side yard laory 5 Side sheet 10 3 story 5 Side yard 5[1] 3 story 8 4 story Il Rear yard 20 Rear yard 15 Alley rear yard 3 Alley rear yam 3 nl or woes [1] Gant Aw: Min ufmn anent Low Pahin9 Per DU WFI� 1. Per -4 So ParyJrg par W/Sp Ft or Sq Ft Guest Wasq Ft Guert Wor Sq Ft twen Residential l 025 Reverend 0 a21 Resltlential ] O35 Uye Wmh l 025 DveLryrk 3 025 Live Work ] 035 Ron Residential 1R00 NorAesidennal 1/300 Nm Nendendal x'SadtI - r:I �LI a Inlieu Fet no M 75a-12. - I�IhI sf: Per ux Notes: In ueu The above table is a summary of the requirements by zone. Rehr 9ntivu161 - to the following chapters of this code for the full requirements per _ building type. The Zones are arranged on a continuum of intensity wiM the most intense at left and the least Intense at right. Each cone is aimed at generating of maintaining a distinct character through the alloca- tion of appropriate building and frontage types and the placement of those types on parcels. TRANSIT ZONING CODE 32 SPECIFIC DEVELOPMENT E4 7 5A-2 6 City of Santa Ana, California TRANSIT ZONING CODE Urban Standards - Zone Requirements Section 41-2010. Transit Villacie (TV) (a) Permitted buiding types and mini- (b) Building Setbacks. I (c) Frontage Requirements. and maximum height Table TV1, entitled Building Types and Mimimum are Maximum Height Identifies the approved building types and the minimum and maximum height that is permitted for each building type within The TV Zone subject to compliance with all applicable standards. Table TV -I. Building Types and Minimum and Flex Block Lined Block Stacked Dwellings H".'6 CO, t Courtyard Housing Live -Work 11 3 3 3 3 3 25 S 5 � see encroacnmem� I l id+ I I I 1 vl Ic jl 8 i jsee ennaarh I ! IT �LL 6 -� Table TV-2 identifies the minimum setbacit -� required and where noted, maximum setbacks :vied 1 permitted. 5 The setbacks shall apply to all stories of a building. 3 TableTV-2-Building5etback Standards. not allowed Tuck -Under Housing 3 3 1 6:.. 11.ed not allowed) ! ta) Front yard 0'[a1 (bl 10 ..hallowed notallowedl 1161 Street Side O'lal [b] 10' TO puadple. (lcl Stdeyad 0' Not House not allowed notalbwed (lot Rearyard IS' Not applicable (d) Parking. (1) Driveway Standards. Table TV<identifies the or m and waitimr.m wu3rh of dassewave Permitted parking on driveways. 20' a. Table TV -5 identifies the minimum off-street parking spaces that shall be provided. All free - buns shall be rounded up to the rsext whole number. Table TV-5- Off -Street Parking Standards Reskential lbl 12/unitmin IO.IS/unit[ guest servo housin, will be parked at I space per unit minimum. b. Vehicular access to the off-street parking Is per- mitted only from an alley or side street when present Vehicular access to the off-street Park- ing may be taken from pdmxry street only when an alley or side street is not present. 3:3 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City d Santa Ana, California lal 1n situations where the existing sidewalk Is 10 feet Or ksz In winch, at the duaretkes or the Chy of Santa Ana, a smack greater than een- died in the above table may be required an effectively rewh In a 10 foot wide acewalk. NI setback at Wand Me. Is 1 S' minimum -2S' maximum measured from the rlghtcfivay as it Mlit, In In 1/2009. 2d H €8 1p 4 ■ ParMng Permitted c. Parking setback standards. Table Ti identifies the minimum setback standards for the off-street parking. The setbacks shall apply to all stories of a building. Table Tv- Parking Setback Standards. I M (lI,Fr lyard b.40`A desgn in I O' bt deptM1 1 IM15keel side 10'min. O'min. I I(2dl Rear yard I i0 cola 1 TORO. I 75A-27 F — pow FPropedyUrs Per Tabke-SethaackUnre TV -I Frontage height and otherre- quirements per Section 41-2033 Per Table y______ TV-3 if parcel has Sale street frontage The ground flour fronting a street or other right- of-way (not including alleys) shall comply with the standards for the applicable frontage type. Sections 41-2033 though 41-2039 and the Table TV -3 enti- Ded Permitted Frontage Types. Table 111-3- Permitted Frontage Types Arcade min.50 ':. Quay mia 50 Shopf., min. 75 - Forecourt Max. 50;remamder of frontage per permit red types (e) Encroachments. 12c - 242.b 2 2a,b i _ 2b fCURB lat—MmYcleardcurb (U Outdoor dimmg Such encroachments Per approval of PEA (Planning IS Building Agency) and PWA Directors, separate permit and agreement per SAMC. (2) Eremachmeno- Awnings, Sgnage, Balconies, Bay windows and Frontage Types may encroach into the required setback subject to the standards ardentified in Table TV-2, entitled Encroachments. Table TV-2 Encroachments OA eaept awnings, and gab' min e' ntn 1E- krY antl arcade frontage clear Iypes t2b) except awnings, and gab m 12 24' Nor and arcade frontage nmax clear types Did awrgngs. and gantry and min rMNYST r facade frontage types l0 daA side yam WA G Rear yam to on r fil ' pl Fava permlrtH rol'ofprmPzrrylare- Urban Standards -Zone Requirements, cont'd (a) Permitted building types and (b) Building Setbacks. minimum and maximum height Table DT-I, emitted Building Types and Mimimum and Maximum Height identifies the approved building types and the minimum and maximum height that is permitted for each building type within the DT zone Subject to compliance with all applicable standards, Including Table DT-3 entitled Building Height TableDT-1. Building Types and Minimum and Maximum Height, Hex Bbck 2 Lned Bbck 2 S3g Stacked Dwellings 2 s._ J d mCotprd Housing 2 5� �11 Live -Work 2 3 1 In a d Tuek Under Housng 2 3 II`d II ed talkwed nexalloved House I ratallowed I mtalkwed Table DT-2ldentlfies the M.N. setbacks required and, where rated, maximum setbacks Permitted. The setbacks shall apply to all stories of a building. Table DT-2. Building Setback Standards ', o+llFlwerud aNl 0' i(1M %!!I 14a aW t0 amrd I' no sOMaraquiremem (c) Building Height and Frontage Require- ments. } Rower --- SeRa[k Llrc Frontage heghtaM gMrreaua! mints per section 42 21---------- NeonNlxa tde slrM(llge (1) Building Height Table DT 3 "titled Building Height Identifies the maximum building height permitted based upon the M width and as per- mitted by indMdk# building Type ` Table DT-3. Building Height ara. 1 51 to 125h 1 4 sfaties I 1(HE Reayard or Manoui¢m®i 12)Thn ground floor Table DT-4. Frontage Types Ild AiryW Y Mert9urement hooting a,al right of floodinge .. (al M st.fians where the adstng sldewa%Is 10 my loot including Arcade Min. 50 feet or less in width,atthe .1 the City alleys) shall comply of San,ta Ana, a utback greaterr than ldentlflN Meton with the frontage Gallery Min. 50 (d)Parking. in the above ode may be required to effenizeiy requirements per Sbopfrou MM.75 resoit In a 10 loot wide still Section 41 Q039 and per the Table mk ,,. Forecourt Max, 54 noran, (I)DrWeway Standards. Table DT-S identifies the Nutted frontage dcr of fro^tWe minimum and maximum width of driveways and Peg laerminrd Permitted parking on driveways. Requirements. ry� Table DT-S Driveway Standards a Encroachments a. Table DTb identifies the minimum off-street Parking spaces that shall be provided. All trac- tons shall be rounded up to the next whole num- ber. Table DT-b. Off -Street Parking Standards. minimum. It. The parking requirements found in Table DRO shall apply only to new buildings, additional building area on existing buildings or cum version of existing Wilding area to a new use. Conversion of Wilding area of an historically designated building to a new use, where the building envelope Is not increased In size shall have no Parking requirement until such time at the City determines that 9S percent capacity on the five existing City controlled parking struc- tures in the downtown has been reached. ■ Parking PermittM c Vehicular access to the off-street parking is per- mitted only from an alley or side street when present. Vehicular access to the ssR-streetpark. ing may be taken from primary street only when an alley or side street is not present. d. Parking Setback Standards - Table DT-y, entitled Parking Setback Standards identifies the mini - mum setback standardsfortheoff -street parking. Table DTJ. Parking Setback Standards 12a1 Front Yard mi141)%kt O'min depth UblSaeetslde 10'min Orion, Ddsideyad onto O'min (2d)ReMyard lamin 3'min (2.) Alley yard 3'mM 3'min 75A-28 (1) Outdoor dining - Such encroachments per approval N PEA and PWA Directors, separate permit and agreement. (2) Encroachments. Awnings, Signage, Bakonies, Bay windows and Frontage Types may encroach into the required Setback subject to the standards indMOfied in Table DT-B, entitled Encroachments. Table DT-e Encroachments (2a) except awnings, and get. mina.max 18, kry, and arcade homage dear _.. types kbl except awnings, andgal mMtr .24e kry, and artade fmnlnpa that typesOc) awnirgS, and gallery, and min sy"r artade hmtage types Itla4r afa S de Yard R s"hil V n 1 bw+amd ro r a P�aprny am. TRANSIT ZONING CODE 3.4 SPECIFIC DEVELOPMENT 34 City of Santa Ana, California TRANSIT ZONING CODE :Urban Standards- Zone Requirements (a) Permitted building types and minimum and maximum height Table UC-1, entitled Building Types and Mimimum and Maximum Height Identifies the approved building types and the minimum and maximum height that is permitted for each building type within the UC zone subject to compliance with all applicable standards. Tablel-I Building Types and Minimum and Maximum Height Flex Work 2 S Lints Block 2 5 Stacked Dwellings 2 5 oA Courtyard Housing 2 5 Uve WOlk not allowed not alloeetl Tuak-Undea Housing .._ 3 '.:Alowed nor allowed Hallowed For allcI (d) Parking (1) Driveway Standards. Table UC<identifies the minimum and maximum width of drhweways and permitted parking can driveways. Table UC4. Driveway Standards 8' a. Table UC-S identifies the minimum off-street parking spaces that shall be provided. All (rac- oons shall be rounded up to the next whole number. TRW UCddf-SYsrR RAig krdrda --- 2/w11tmM 10.15 I Non-BandentialI t/3meft I building area on elinticto builUlnas or con version of ex zt lu building a ea to a new use, Conversion of buddine areaof an historically de,agnated build no buildirw to a new use. where the envelope is not increased in sae shall have no oarkino recruitment until such time as Vehicular access to the off-street parking is Per minted only from an alley or side street when present Vehicular access to the off-street pad (b) Building Setbacks. see encmildarent, Id I �1a�1�papa flrpgMhrrrerlb 1 II lean Fay lb ' Table UC-2, entitled Building Setback Standards Identifies the minimum setbacks required and where noted, maximum setbacks permitted. The setbacks shall apply to all stones of a bu l ldi ng. Table UC-2. Building Setback Standards. 0a1 Frontyard o !e1 0' Ilbl SVeetSide n'Fal 10' fmi Weevil 0 Noregml nm Rearyad is Noregmt Ia1 In dtwtbos h. the existing,A.e Ikis 10 feet or kn in width, ar the d'ocretion of the Cry of Santa Ana, a setback greater than Idea ti0ed m the above table may be aequned to effectively result in a 10 foot wide sidewalk. F77 Padmg Permitted ed Parking setback standards. Table UC6 iderill. fies the minimum setback standards for the Off-street Parking. Table UC6, Parking Setback Standards. Ral Foreld mMse%btdeptn 5'min Rol Shearlde s'mar s'man RtlNdeyad T— scum (2d)rer Wad 5inin s'min 12el alley yard a'Mn Jmin (c) Frontage Requirements n� ao.W nwaery lane a Sebku- Fmnrige height and older rv,.r ment, pn Seclm 41 2ay---------- irpartal has ode .feem, The gfaaadllmr fronting a street or other rightly -ply (cut including all shag comply with the standards for the applicable frontage type, Sections 41-2033 though 41-2039 and the Table UC-3 entitled Permitted Frontage Types. Table t1C-3. Permitted Frontage Types shop(,.,, min 65 Forecourt max 50: remainder of frontage per allowed types Stoop '.. ..So FrontyartlRorch max 100 (e) Encroachments aNvxede RnW. Pro im, Law Frcroa[nmem Far sNbalxW table ben. 2' X +12AI, ID r—wnraerMa.n (1) Contract dining - Such encroachments per approval of PBA and PWA Directors, separate permit and! agreement. (2) Encroachments. Awnings, Signage, Balconies, Bay windows and Frontage Types may encroach into the required setback subject to the standards mdenhfied in Table UC-], entitled Encroachments. Table UC-1. Encroachments (2a) e¢ept awnings 'min B'dear macIs- libl except awnings reel war mix2a' d-r Rd awning, mkt within 2' '.. lacks, acurb 5ideyard WA 0' Rearyad '{mane 117 5. ICY yard maawlll l 3' I n faw aaawd m 3' d popertY acre. SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 75A-29 Urban Standards -Zone Requirements Urban Standards - Zone Requirements, cont'd (a) Permitted building types and maximum height Table CDR 1, entitled Building Types and Maximum Height identifies the approved build- Ing types and the maximum height that Is per- mltted for each building type within the CDR zone subject to compliance with all applicable standards. Table CDR-1, Building Types and Maximum Height. no, Al""t Flex Block 3 ji s it notallowed Slacked Dwellings not allmeed Hybritl Court notallowed Counyad Housrrg notallowed IaneAltale 3 Rowhouse notallowed luck -Under Housing notallowed Bungalow Court notallowed Dupkx/Triplex/Quad-I notallowed (d) Parking. (1) Driveway Standards. Table CDR4 identifies the minimum and maximum width of driveways and permitted parking on driveways. Table CORA, Driveway Standards I -way 9' 2�evaY 20' '(jV lal boost as modified to meet fire and trash sernc nts (2) sNFstreet parking standards Table CDR-5, entitled Off -Street Parking Standards Identifies the minimum off-street park- ing spaces that shall be provided. All fractions in the parking calculations shall be rounded up to the next whole number. Table CDR-5.OH-Shalt parking Standards (b) Building Setbacks. �eie.erc,g.elmntt� I area 1°'it i I I I I »l 7i l b-t SWe Table CDR-2, entitled Building Setback Standards Identifies the minimum setbacks required and, where noted, maximum setbacks permitted. The setbacks shall apply to all stories of a building. Table CDR-2.Building Setback Standards. (ta) Front ryrd 5'1alfin) 15'[b] (to) Street side 5 [al d 17[c] (III Sldeyard 0Not applicabk� EOdl Rcanyud - IS' Nertapplicabk Del Alley yard 3' Not applicable [a) losituafions rAMRaseY6ana ddewalk is 10 rear or kss in width M the eiscretbn of dw City of Santa Anar a seMack greater than dare rifled In Me inner, table now be req Wred to eRanreb result'm a so loot wide udewaa. fill Setback at Grand Ave is 20' min 30' max maa. lured from R OW as it exists in 2009. Ic) SeMark at Grand Ave. is 15' met - 25' may met cored Rom R O W as it wish In 20(ye ■ parking Permitted (4) Parking Setback Standards. Table CDR6, end - tied Parking Setback Standards identifies the minimum setback standards for the off-street parking. Table CDR6. Parking Setback Standard, (c) Frontage Requirements. a6% '^'PralrartY urn ( JI-SnbxkLFn Net I hwA ad°""' r�-^----- 4 _ _ _ _ CDII-1 t I TaMa_t.__ Co" I 'i wr «I cut We ------------ beet hostage The ground floor fronting a street or other right- of-way Inot i enrols lg alleys) shall comply with ttK standards for the applicable frontage type, Sections e1-2033 though /1-2039 and the Table CDR-3 entitled Permitted Frontage Types. Table CDR-3- Permitted Frontage Types WEery minas iere0)IRt meW. remainder of hostage pen . abwetl types , shopiront minis - (a) Encroachments (1) Outdoor dining. Such encroachmenu per approval of PEA and PWA Directors. separate Permit and agreement. (2) Encroachments. Awnings, Signage, Bakonies, Bay windows and Frontage Types may encroach Into the required setback subject to the stan- dards indentified in Table CDR-y, entitled Encroachments. uwwak a 2/wMnw sacs/wit Table CDR-2. Encroachments NanAaFWwOd I/MpaeR Ilan fmn'v+id sro. sr or to width u ul Frog nab so i..am [a] Permanent Special Need Horsing Including Dbl street sme — - - - senior housing will be soaked at l space per cont Or15�deyerd - 12ai Front (2c)B'clear i min. Odl R. yard (zb) sde street (2010 ' z' ' Acc icular to off 131 VehicuWr spent w en present. ces Vehicular access lad Alryyid Dd dear street Parking is permitted only from an alley -- S1de or side street when present VehicuWr access to Yard Not aODl came O the off-street may be taken from primary street Yard toeave Ill T only when an alley or side street is not Present. A3eyryd roeave [11 3' DI Eaw anmmed in 3' of "opme Ise, TRANSIT ZONING CODE 3E SPECIFIC DEVELOPMENT •A 7 5A-30 City of Santa Ana, California TRANSIT ZONING CODE Urban Standards - Zone Requirements Section 41-2014. Urban Neighborhood 2 UN-2 (a) Permitted building types and maximum height. Table UN2-1, entited Building Types and Maximum Height identifies the approved building types and the maximum height that is permitted for each building type within the UN-2 zone subject to com- pliance with all applicable standards. Table UN2-1, Building Types and Maximum Height. ele, ee.r. :.,n"'W lined Bln: p. not Mlmved Hybrid Coud 51a1 Courtyard Hommg 4 Lae Work 3 Nowhouse 3 Tack -Under Housing 3 Bungalow Court 2 - Duplew9npIaoQuad 3 Flex House 2 ill See ReguktlnO Plan for allowable bcid'. (d) Parking (1) Driveway StandardsTable UN24 identifies the minimum and maximum width of driveways and permitted packing on drweways. Table UN24. Driveway Standards l way 8Or 12' width of 2a ran Excem As modified to meet fire and trash service remunnsl,nt, Table UN2-5, entitled Off -Street Parking Standards identifies the minimum off-street parking spaces that shall be provWed. All fractions in the parking calculations shall he rounded up to the nest whole number. Table UN2-S. Off-street Puking Slandai Residmtbl lal 2/unR min O35/unit Live -Work 2/uMtmin 0.15/unit Non-Aktudential 1/3001111 (s1 Permanmt spend Need Fares, od.dirg senor Ilousilg, de be Parketl at 1 spa¢ per unit min. (3) Vehicular access to the off -sheet Parking is Permit led only from an alley m side street when present. Vehicular access to the oft -street may be taken from primary street only when an alley or side street Is not present. 3:7 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, Calsomia (b) Building Setbacks. 1p Q Union Sete Table Eli entitled Bedding Setback Standards identifies the minimum setbacks required and, where noted, maximum setbacks permitted. The setbacks shall apply to all stories of a Wilding. Table UN2-2. Building Setback Standards. Ilal Frontyald 10'1.1 25'min firand Ave 2ooar.u.w.) Ilbl at uitle tall Not Ppleat (tel 5tl Yartl s'-1/Salary f 3abry 13 a, nor 0d) Rlo,is. If Not pptkabk (1 1 Alley yard r W PPIicaOk W Inutuationswhere Meinustklgsidewabl1/0 Cly f leas in Ana, a settard, neti, than ke oty of Santa An;a ut miry eler[han as ��. owns the above table may bee siuked l0 effectively rerun in a 10loot wide sidewaaL ® Parking PHmittN (4) Parking Setback Standards -Table UN24, entitled Parking Setback Standards Identifies the minimum setback standards for the off- street parking. Table UN2-6. Parking Setback Standards Iyl From raid 50%bt la min MPh n3515treet side la Mn Ia min OC Side yard S'mM S'on eldt lieuyw float 5'min OelANyyad 3'min 3'min 75A-31 (c) Frontage Requirements. .on —.I.-napensune i;e-semackune hdi alh �ITabk IUN1-I: Able _--_- UN2J r_. I apa-i a1RM The grosad floor fronting a street or other right-of-way (not including alleys) shall Comply with the standards for the applicable frontage type Sections 41-2033 though 41-2039 and the Table 1.1142-3 entitled Permitted Frontage Types. Table UN2-3, Permitted Frontage Types Shophont rtin65 frnemun mail SU. remande, offromageper allowed types Sloop max50 Fronlram; Poch may 100 (e) Encroachments __ Alwstake —.I �PropwN Lirw Lxmadmenepn ' seltu[k Lue to lrbelow i—e 2, T —41 2b 1. Outdoor dining - Such encroachments per approval of PBA and MA Directors, separate Permit and agreement. 2. Encroachments. Awnings, Signage, Balconies, Bay windows and Frontage Types may encroach into the required setback subject to the stan- dards indentiBed in Table UN2J, entitled Encroachments. (21b) e C nt awn ngs min IT .24' )ear (20 awnma,s _ min I0'dNr r Side yard WA 0' �Rear --Ailey yard meawlll IF rear yard meavan) f [ I I live allowetl to 3' d prepe" line. TRANSIT ZONING CODE Section 41-201 S. Urban Neighborhood 1 UN-1 (a) Permitted building types and maximum height Table UNI-1, entitled Building Types and Maximum Height identifies the approved build- ing types and the maximum height that is Per- mitted for each building type within the UNI zone subject to compliance with all applicable standards. Table UNI-I. Building Types and Maximum Height- -- hredaloIX I not apwetl _Live -work Rowh.u. net .Rowed 2 (d) Parking (1) Driveway Standards. Table UNI4 identifies the minimum and maximum width of driveways and Permitted parking on dmeways Table UN 14. Driveway Standards 1-way I IT 12, «width of 2D (2) Off-street parking standards Table UNI-5, entitted Off -Street Parking stan- dards identifies the minimum off-street park ing spaces that shall be provided. All fractions In the parking calculations shall be rounded up to the next where number TableUN 1-5, Off -Street Parking Standards. Mon-Peslsi 1201. I sao w N l 2.a (r Will - le] Permanent Special Need Housing Including senior heus- In%wa be parked at 1 wate per unit min. (3) Vehicular access to the off-street parking is Per- mitted only from an alley or side street when present. Vehicular access to the off-street may be taken from primary street only when an alley or side street is not present. Urban Standards -Zone Requirements, 6n st (b) Building Setbacks. Table11141-2, entitled BuRklinq Setback Standards Identifies the minimum setbacks required. The set- backs shall apply to all stories of a building. Table UN1-2.Building Setback Standards. (1 a) "'.i Front Yard 30' life _i_StreeI side lr 0G sMe rand r tt4 Rear yard 1p' o,( Alkyyard )' spent Skk ® Parking Permitted! (a) Parking Setback Standards-TableUNtb,enti- tled Parking Setbxk Standards identifies the minimum setback standards for the off-street parking. Table UN d. Parking Setback Standards (a)Front yard 2M lot depth (b)Street side 10, min, (c) Side yard o'min (d)Rear yard O'min (a)Alley yard Tmin 75A-32 (c) Frontage Requirements a C'^o«.Iyl.ar '�I" wswaaun I 2. Iprtornate rm.hikhandader mwxs pwsecupnu The ground floor fronting a street or other right-of-way (not including alleys) shall comply with the standards for the applicable frontage type, Sections 41-2033 though 41-2039 and Me TableUNI-3 entitled Permitted Frontage Types. Table UNt-3- Permitted frontage Types Stoop max 50 Lfmntyard/Porch ma. IN (e) Encroachments 1. Outdoor dining - Not permitted. 2. Encroachments. Awnings. Sgnage. Balconies, Bay windows and Frontage Types may encroach into the required setback subject to the standards indentified in Table UN1-7, entitled Encroachments. Table UN1-2. Encroachments (2a) P«dr .5, weal 2039 Lau 114-indeebaleory _max 2' Io nave 111 (21) 9hyaN u2' 1.'aeltl flan ms' _ Ioe.113 ABeygaryaN 3' m«se ill I11Eawak-N te>ofpe eaty NIIa TRANSIT ZONING CODE 3r SPECIFIC DEVELOPMENT 94A a 848 City of Santa Are, California TRANSIT ZONING CODE ;4.0- Architectural Standards Division 4. Architectural Standards/Building Types. Sec. 41-2020, Building Types, General Provisions. (a) Each proposed building shall be designed in compliance with the Standards of the applicable building type. (b) Subject to the requirements of the applicable zone, a proposed building shall be designed as one of the building types Permitted by the applicable zone by Table BT-1 entitled Permitted Building Types. Q `1 , hh,k ORowhouse Table 6T-I. hymned luMdirg Types _ Y=Permitted —NotPermitted NUR so.a omwr wr one. savnaa sm... Building Type 1-0, Iae raipe In Building Types Allowed by Zone 111 The degree of mixed use depends on the particular m Ixl j zone in which the building is boated. — TV DT Ilc CM UN-2 UN-1 A.Tbwzr-ohrudium rts YES n so z OgP 8 'I1 r - t2)In dwelling units per acm(du/ac). Each type is sub- " )ect TU the maximum Stories allowed in each Zone LNexNock rts YES m-ao Saalpl Mn n- Y Y ♦ Y - - - - and Meparticular building size and massingrequire- GDmdBIIXk rts YES '4f-SO Ha10T min IZa'-m mend 0. ftxked DweWrgs rts 9 A-m 'mIn lis'zW r r T - LHybridCoun YES 14 u-m Ilsa- ISB-mP B - Yp - t31 Measured along the front property line of the lot E Courtyard Housing YES r6 m-w IaTdII IN-a11 B ♦ r T r - (4) This building type can be used on lots that have 4 UveM'ark No rET 12-Is ma'-mI W-tn S T Y ♦ r r Y resulted from a legal subdivision provided there is a K Rowhause rts ITS T-la Ipo'-zoo 11-ISe a V minimum frontage of 40 feet. tsel-um r YES rts - Il 19 - - ys'mw M'-2517 B Y r r r - 161 Allowed on specific locations only. 'J. Bulgalow coon rts ru ' 10-I5 1le Mn Iatl-tar B - r r x. Duple rplehl M INS 1a-Is lox xxx i !-tn B r rm t61 Wadplex not Permitted in the UNA zone. Ouadplex L. House Iq M S a too' mIn aaao' i Y Y i ITI Cne 81ock perm tted [O a maxmum of 10.s[odes In M.NOt15F L KBUNGRLO'N ATHOSINDFA LBOWHOUSE N.ISVE\ a P1UADPIIP Is FLEX COURT NOOSING WORX 4 ❑ ❑ 4.1 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 04 City of Santa Ana, California 7 5A-33 4.0 - Architectural Standards, cont'd Below: This diagram identifies the range of building types used m the Code. The individual types are arranged on a continuum of intensity with the least intense at left and the most intense at right Each type is allowed as identifiecion table HT -I and its requirements are described on the following pages. O F. COURTYARD HOUSING e Tuck -Under laud, • Hybrid Court • OupWnpklOuadplex Ber br lintratwe Ran Oeagram: ', grrHAcmi(WaLup access) ® Point-GccaslN.Ik prces0 - Pomi-Access (Tower) sae Sectlnn BA ardefinitions A E. HYBRID COURT WALK-VPACCESS D. STACKED DWELLING i_ll�i � Fr • C- UNEO BLOCK VIIBLIC PARI(ING WM4f oa OTHER FACELEBS STRIKT➢RE Is House • L FLEX BLOCK • A.TOwHIOMIOpYM TRANSIT ZONING CODE Al SPECIFIC DEVELOPMENT FA 7 5A-34 City of Santa Ana, California TRANSIT ZONING CODE : Architectural Standards (c) All building types are subject to the following: (1) Lot width and Depth: a. The width and depth shall be determined as described below: All buildings shall be designed to an Individual lot as required in Table 87-1, The lot is for design purposes and may be made permanent through the regular process for parcel of ract maps. Lot width and depth shall be determined as described below. 1-Front (Lot Width): Primary (Principal) Frontage 2- Side (Lot Depth) 3- Rex (Lot Width) r' 3. f3 lyl I I 2 C I Z Z 1 i ! ✓.3 2 3y - ItZ 1 1 2 ly1 b. On comer lots fronting two streets, either street frontage may be used to comply with the lot width/frontage required per building Type. c. Lots that have muited from a legal subdivision but am less than 40 feet of width may be developed with standards that apply to lots 40 feet in width. (2) Access Standards: a. Where an alley is present, parking and services shall be accessed through the alley. b. Where an alley is not present, parking and services shall be accessed from the street through or alongside the building as permitted in the zone and this division. c. For corner lots without alley access, parking and smim shall be accessed horn the side street through or alongside the building. (3) Parking Standards: a. Entrances to garages, subterranean structured garages or driveways shall be, located as close as possible to the side on rear of each lot. Is. Surface parking Lots shall not encroach into any required yards. (4) Service Standards: a. Services, including all utility Access, above ground equipment and trash enclosures shall be located on alkyl Is. Where alleys do not exist services,mcading i ibty access, above ground equipment, and trash enclosures shall be located in compliance with the building location standards for the zone and this division. c. No trash enclosure shall be located in required landscapa areas, within direct view of streets Or in traffic or pedestrian aides. d. Services and their appurtenances shall be screened from and shall not I located in required setback or landscaped areas. e. Each residentlal unit shall have access to on -site laundry facilities. I. Each development shall provide a trash area. g. Murnple family, commercial and industrial developments with common parking areas shall provide trash enclosures per 41 L23. In, Residential development providing individual trash combiners shall provide an area that measures a minimum of 3 S' x 71 outside of required setbacks and yards, to store and place out for pick up. I. Individual trash bins located in a garage shall not encroach Into the required parking area (5) Open Space Standards: a. Balcomes are permitted in any setback yard as provided in the encroach- ment requirements ot the applicable zone. It. Private patios may be provided at the side and rear yards. c. The area of any patio coven, gazebos and other roofed shade structures with at least 2 sides fully opened to the outside may be counted towards the required open space. d. Coridas, walkways, pastor,driveways, parking courts, lobbies and other such spaces shall not be included in the required open space cal- culations (6) Landscape Standards: a. All setbacks, yards and shared common open spaces shall be land 'taped. b. A landscape Wifer of not less than 5 feet shall be provided to separate any parking lot from an adjacent property c. Surface parking lots shall be landscape par the City Commercial area landscape standards. (7) Frontage Standards: a. Frontage shall comply with the applicable standards set forth in Sections 41-2033 through M39. (8) Building Size and Massing Standards: a. Buildings shall be constructed with a varied massing approach. Each building type contains an allowed massing by story table identifying the maximum ratio for each building story, Table BT-Aidentifies the infor- mation contain within each of these allowed massing by story tables. Allowed Massing by Stay slolly GAx Ax. i ] e a Nrtwltage 100 Pememage numisomft'aodf ofg..d percentage of the ground fact by Boor foptort a the build "city Iy area that b permitted for this particular Rory_..._.. IS, The maximum permitted ground Boor footprint shall be determined as described in Figure IIII c Story heights 1. A story means a habitable level within a building from finished floor to finished ceiling. Specific requirements for a story in various con- figurations are identified in Table Bi-2 Permitted Height by Story Type: Type LPWbn M116mum IFU Matl�n (fitl All building types, wdudiy house. duplex Upper FIRANS) 9 14 triplex and quadpkx AN building types, wdushN house. duplex Ghuind Floor 10 16 in*, aM quadpkx House, duplex triplex UpperFlo« a 14 And! quadplex House duplex Inri Ground Floor 9 12 and Wail Wrage Upper floorlsl a 14 --- G floor Equal aadlxara Garage Fi (podium) ground foor o/WYdinq 16 «kineir .uxh.d 2. A basements shall not be considered a storyfor the purposes W determining building height where the finished surface of the floor above the basement is less than six feet above grade plane 3. Attics shall opt be considered a story for the purposes of determining building height. 4. Aboveground gauges occupying a level shall be considereda story for the purposes of determining building height. d. Dwelling Unit Types There are three basic dwelling unit types. I. The flat is a single story unit. 2. the loft is a double -story heingt unit that may have a meaaanme. 3. A townhouse is a two a more story unit. Them dwelling units types may be used in any combination through- out a building, as permitted by the various buildings types. (9) Accessory Dwellings: a. Second dwelling units shall comply wish the requirements established in Section 41-194 of the Santa Ana Municipal Code. (10) Accessory Structures: a. The area occupied by accessory structures shall be included In the floor area ratio calculation. b. An accessory structure shall rot encroach into any required open space or setback except that a detached garage may be located 3 feet from the rear and interior side proparty line. 43 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 64 City of Santa Ana. California 7 5A-3 5 4.1 -Architectural Standards, cont'd RUM W4L Maintaining PWMM\d BaalldBg Un IGwlrl Row Foeysred) alnd vahane suect oe Fa 20 Step 1: Existing Site • • . • • • • • • • • • • • • 110 Step 2: Apply Lots • • • • • ^ ^ ^ • • • • • •) Step 3: Apply Building Setbacb • • • • • • • 1 a. B existing site meets subsection 1 or 2a. Per allowed building types identified 31. Per the standards In Division 3. apply II below, applyiabler 6A, Subdivision in Table BIT 1, select building rype(s), the required setbacks to the logs). Guidelines to generate a block(a): I. Site is not in compliance with Fig- 21b. Apply lot standards for each selected 3b. The result Is the allowed biding ure 2.1 or as adjusted by Street building type and identify loin) to placement area on the lot(,). Network Concepts, section B,C. receive a building. ii. Site exceeds the block dimensions per Table 6A, Subdivision Guidelines. I b. B existing site already complies with the subdivision quidel'mes and street networt concepts, proceed to step 2. Step 4. Apply Wen space wquirementx See Figure BGC 4a. Per the Open Space Standards Ofthe applicable Building Type, subtract the required area to tit (e.g., 155d). Lot Ito receive a building) (-) minus setbacks required (-) minus open space area required (_)equate 10 Ground Floor Footprint 4b. Apply Ground Floor Footprint to the allowed massing scenario to identify the maximum square footage permitted for the building. Blunratire Example: Plan Diagram Two adjacent county" hpekg euBNrgs lens gunner. Example: A.mwmetric Diagram Two adjacent caxtya d trWsuq twitling, I • •)o Step 5. Apply individual design 5a. Design the building(s), per the individual requirements of the selected building typeu) in Division 4. The example above (plan and axonometrk diagrams) shows two courtyard housing lots being designed for one courtyard housing building each. FIgw1 Pi open space Area 147 ®1)in determining In< grounJ W Mosinee, regwrM apen,ye un 6e vubnanN i, Pon the blrn rimthe epen,pne u n aWixV,e .' or on s podium cubing rw4uNn LMacIu mEOwn fwre aluMMw Eunyae'. Sae pen weh aaM \ nired po0ym w,uLlmenean aaraweAlaee aas w,, n wn b rmv.en Peer, I alu,unive E-iniNk Subenar garage wIh fe.s 0 1,1ere , n wn a nqui,ed open Ilurl nrve rumple. 1+ 1- garage MM de l Ngwage rerrrq a wrt d rquvrE open 75A-36 TRANSIT ZONING CODE 44 SPECIFIC DEVELOPMENT 84 City of Santa Ana, California TRANSIT ZONING CODE : Architectural Standards -Building Types fiktstriebw Axonometrk Diagram Mushadve Phota Ttwwr on Podium Illustrative Photo: Tower with stoop front Left Illustrative Photo: Tower -on podium Sec. 41-2021.Tower-on Podium Building Type (a) Toweron-0adium is a mus"vel building organized around a central core with the first two to five Boors expmaed as a podium building. (b) Lot Width and Depth. .Themnimum and maxi mum lot Nth and the minimum lot depth shall be as prescribed' T bielyi (Perm'tted fluddino TvossEL (0 Access Standards (1) Entrance to the tower shall be through a street level lobby. (2) Entrance to each ground floor unit shall be directly from the street at least every 50 feet The entrance to each Podium floor unit shall be directly from the podium. (3) Access to all other units shall be through a lobby and elevator. 14) Access to each unit above the third level, not accessed through a podium, shall be through a central interior corridor of at least 6 feet in welsh with recessed doors or seating akmes/ofi sets at least every IDO feet. (S) Each level of the building shall have access to the garage via an elevator. (6) Entrance to the residential Portion of Me building shall be through a dedicated street level lobby, or through a dedicated Podium lobby accessible from the street or through a side yard. (d) Parking Standards (1) Required Parking shall be in a completely concealed garage. tithe garage is partially or wholly on the ground, then it shall be lined by a commercial or residential units. (2) Dwellings shall have vid iced access to their Parking stalls). (e) Service Standards (1) utility meters shall be screened from view from the street and shall not be located within any required landscape or setback area. (2) Mail boxes shall not be located in any required open space, landscape or setback areas or detract from the primary, entrance to the development. (f) Open Space Standards (1) A quadrangle -shaped common open space (hereinafter quad') of at least 20 percent of Me lot shall be located on the ground level, on a podium or on a roof garden. The quad shall be open to the sky. (2) Minimum dimensions for the quad shall be 6o Irwin each direction. Pefmined frontage types and architectural projections are permitted on all sides of the quad provided that the overall minimum dimension of quad is maintained. (3) Private open space shall be provided for each residential unit and shall be no less than SO square feet with a minimum dimension of 6 feet in each difection. (4) Private open space may be substituted for additional common open space or common inte- rior space, the size of which will be equivalent to the displaced private open space. The mini- mum dimension of this space shall be 20 feet in each direction. (g) Landscape Standards (1) A minimum of four (4), 36-Inch box canopy trees shall he planted per quad. (2) Where side yards are present, one (1) 24-inch box tree per 30 lineal feet to protect privacy of neighbors. The trees may be placed in groups in order to achieve a particular design. (3) Smaller quads in interior courtyards will require shade tolerant plant materials. (4) Six (6). five-galion size shrubs, ten (10) one -gallon size herbaceous perennials/shmbs and turf or acceptable dry climate grourN cover shall be planted for every required tree. (h) Frontage Standards (1) Arcades, galleries, shophom and foracourt may not encroach Into the required minimum dimension of a quad. (1) Building So. and Massing Standards (1) Bul Nings shall be composed of bases and towers. Bases shall be 2 to 5 stories with towers rep- resenting a proportionally smaller footprint as specified in Table BT-3, entitled Maximum Ratio for each Towar-on-Podium Story and composed as bundles of different heights to enrich the Skyline of the City. (2) Buildings may contain any of 3 types of dwellings: flats, townhouses and lofts. (3) Units may be as repetitive or unique as deemed by individual designs. (4) Buildings may, be composed of one dominant volume, flanked by secondary ones. (5)The Towmrs APodium shall comply with the height ratios established in Table BT-3: Table Bf-3. Madhnurs Ratio for Eachlrovsam mPosium Story shad.um Wtlo Meac6Towerbn m5rory STORY Ground Floor ,, E-20 (or middle 3/5 of the 21-25 (or top 115 of she builklanol %cfgroulN Asm 100% IN SOAII] 35% [1I For any Percentage less than 100%, the Percentage refers to the percentage of the ground floor footprint of the building area that is Permitted for this particular story. W AccessoryDwelYngs. Accessorydwellings shall nwtbe pemMed. (k) Accessory Structures. Accessory structures shall not be Permitted. 43 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 7 5A-37 Architectural Standards - Building Types, cont'd '11-1-11-URATpN E%AMVLEs .pint access podium (walk-up access permitted) wer(point-access) ouM Floor access --- equired per frontage type sWa rdS Below: Examples of allowed Toneroniodium sae coMgurmions PERMITTED USES IDev mfl., ortow on Fodrun are avarlabk ares.nw:denU rn.nebea»ru,, Iod,-,. remenu m table 3A. LAnd Use Snnda,ds. KEY_ _ USE o OFFICE ORT COMMERCIAL I RETAIL R RESIDENTIAL 75A-38 TRANSIT ZONING CODE A4 SPECIFIC DEVELOPMENT as City oT Santa Ana, CaIII.Onm TRANSIT ZONING CODE :Architectu2l Standards -Building Types Illustrative Axonometric Diagram Illustrative Photo: Flex Nock with shopfront frontage Sec. 41-2022. Flex Block Building Type (a) Flex Block Is a building generally of a single massing element designed for occupancy, by retail, service, or office uses on the ground floor, with upper floors also configured for those uses m for ) k m. YYYY (b) LOt Widthand Depth. of The minimum and nn+_v'm of width nd he m'ri mum la dedh dull be as prescribed in Tableli-t (Permitted Building TvneS1 (c) Access Standards a (1) The main entrance to each ground floor unit shall be directly from the street. (2) Enhance to the residential Portions shall be through a dedicated Strcet-kvel lobby, or through a dedicated podium lobby accessible from the street or through a side yard. (3) Access to each unit above the second level, not accessed through a podium, shall be through an interior conidor of at least 6 feet In width with recessed doors or seating alcoves/offsets at at least 1 DO het. (4) Each level of the build ing shall have access to the garage via an elevator. (it) Parking Standards (1) Required parking "it be accommodated in an underground garage, surface parking, luck under parking, or a combination thereof. (2) Dwellings shall have Indirect access to their parking stallo) (e) Service Standards (1) Utility meters shall be screened from view from the street and shall not be located within any required landscape or Setback area. (2) Mail boxes shall not be located in any required open space, landscape or Setback areas or detract from the Primary entrance to the development. g a D a s e ha I��gas c u�ar o In front as a forecourt. This area shall be equal to 15 percast d the lot and shall be open W the sky. Courtyards may be located on the ground a m a podium. Side yards may alw be formed to probde outdoor patios connectN to ground Boor commercial uses to serve u 0 1 s�. 2 Inimum courtyar dimensionssa be 40 ee[�ien the lo^9 ulsdthecourtyard norh ented EW and 30 feet for a NS orientation. Courtyard proportions shall not be less than 1:1 between the width of the courtyard and the height of the building for at least 2/3 of the court's perimeter. Horizontal shifts in upper floors adjacent to a court may not exceed 1/2 the height of each upper floor. (3) In 40 foot wide courtyards, frontages and architectural projections are Permitted on two opposing sides of the courtyard provided that an overall minimum width of 40 fear is main- tained. Frontages and architectural projections are permitted on one side of a 30 foot wide courtyard provided an Overall minimum width of 30 feet is maintained. (4) Private open space shall be provided for each residential unit and shall be no less than 50 square feet with a minimum dimension of 6 het in each direction. (5) Private open space may be substituted for additional common open space or common inte- rior space the size of which will be equivalent to the displaced private open space. The mini- mum dimension of this spare shall be 15 feet in each direction. (g) Landscape Standards (1) Where rear yards are present, at least one (1) 36-Inch box canopy tree per 30 lineal feet shall be planted directly In the ground. (2) Courtyards located Over garages shall be designed to avoid the sensation of forced podium hardscape. (3) Sideyard trees shall be placed to create a particular Sense of place at a rate of one (1) 2a-mch box tree per 30lineal feet. (4) Where a front yard is present, at least one 11) 2a-inch box tree Per 25 lineal feet shall be plant - 0.The trees may be placed in groups in Order to achieve a particular design. (5)One M6 mlb box specimen tree is required per courtyard that meets the minimum dlmen- slons. For courtyards that exceed the minimum dlmentlnns, two or more 2ainch box smaller size trees may be substituted for the 36-inch box tree. (6) Six (6) 5-gallon sized shrubs. ten (10) one -gallon size herbaceous perennials/shrubs and turf or acceptable dry climate ground covershall be planted for every required tree. (7) Where rear yards are present, at least one (1) 36-inch box canopy tree per 30 lineal feet shall be planted directly in the ground. (h) Frontage Standards (1) Entrance doors and social rooms, such as living rooms and dining rooms located on Me ground floor, are oriented fronting toward Me courtyards) Or street when fronting to one. (I) Bulking Size and Massing Standards (t) Each unit shall have at least one side exposed to the outdoors with direct access to common or private open space. (2) Buildings may contain any of three types ofdwellings: flats, townhouses and lofts. (3) Units may be as repetitive or unique as deemed by individual designs. (4) Buildings are allowed to be composed of one dominant volume. (5) The Flex Blab shall comply witht the height ratios utablished in Table BTi entitled _ Maximum Ratio for Each Flex Block Story. Ta leR aximum Ra' STDR3' Ground Floor 6,10144 %of ground floor 100% 100% nu%fow rRI Ii1W Faaq pemaeaq. ku Men t0aa6,the percentage Merl toted pert<nbgedMegrouM floor IootWlnt dMe bunking area that b pamared fa this prticuDr rtory. lk Accessory Structures Accessory structures shall not be permitted. 4:7 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City Of $.or. An., California 7 5A-39 Architectural Standards - Building Types, cont'd XEY TO CONF IGURATION EGMPLES ■ Point access podium(walk-up access allowed) Ground Floor access required per -- frontage type standards ® Min. 100 It setback from all rights ofwayfor stories 6-10 PERMITIEO 011 S The various floors of Hex aloes are available for the .— muntifi,d In the diagram below subject to the requirements in Table 3A Land Use Sunsmds. KEY USE O OFFICE _�pba ff6m. aspermrhe3 URr COMMERCIAL RETAIL aid tic. � R RESIDENTIAL ul re I 1 I I � gelow: Eaamples of allowed Flex Block she configurations STREET STREET yI Min 13V in 130' I I I 0 _.. o I r • I I • O • --.• • O I I 1 �I �I w < s- Parking a e I I I I I I I I nmssranve Plan umgram - L Iam PIP A STREET Min130' �f I 1 I I I I 8 I I � Parking Q Court I I I I Ilh,[irlfluw nnlanr m Framnl � --•'� STREET IRu danve Plan ougram -Example R STREET Min 130' I I I I I I I I 1 I I I I�I I<I I I I 1 I I I I TRANSIT ZONING CODE of SPECIFIC DEVELOPMENT Ea 7 5A-40 City of Santa Ana, CaNfurnia TRANSIT ZONING CODE : Architectural Standards -Building Types Illustrative Axonometric Diagram: Lined Block Nlus[ative Plato: Lined block with shopfron[ frontage Sec. 41-2023. Until Block Building Type (a) Lined block Is a building that conceals a public garage or other faceless buildings, designed for occupancy by retail service, or office uses on the ground floor, wish upper fc ors also configured s a (b) Lot Width and Depth. .The on m and maximum lot - - b[ h Iv-L he �•+� lo Tab1eBT-I Ipe insid BCild' T I k aAccess Sta»�r s (1) The main entrance to each ground floor shad be directly from the street. (2) Entrance to residential portions of the building shad be Through a dedicated street level lobby, or through a dedicated podium lobby accessible from the street or through a side yard. (3) Access to each unit above the second level, not accessed through a podium, shall b , through an interior corridor of at least 6 feet in width with recessed floors or seating akoves/offsets at least artery IN kart. (4) Each level of the building shall have access to the garage via an elevator. (d) parking Standards (1) Required parking shall be accommodated in an underground or above ground garage, tuck under parking, or a combination thereof (2) Dwellings shall have indirect access to their parking stall(s). (N Service Standards (1) Utility meters shall be screened from view from the street and shall not be located within airy required landscape or setback area. (2) Mall boxes shall not be located in any required open space, landsope or setback areas or detract from the primary entrance to the development. IT e (I a om oar s <e sir 11 e• d sig a as c u ar ri M hunt as a forecourt. This area shall be equal to I S percent d the lot and shall be open to the sky. Courtyards may be located on the ground or can a podium. Side yards may be famed to p vie o p No c n ct d[ g ou d oo c 1 er ial (2) Minimum cwrtyard imeas on she I be 10 feet when t e ong axis o Me courtya b oriented EW and 15 feet for a NS orientation. Courtyard proportions shall not be less than 1:1 between The width of Me courtyard and the height of the building for at least V3 of the court's perim- eter. Horizontal shifts in upper floors adjacent to a court shall not exceed 1/2 the height of each upper floor. (3) In 20 foot wide courtyards, frontages and architectural projections are permitted on two opposing sides of the courtyard provided Mat an overall minimum width Of 20 feet o main- tained. Frontages and architectural projections are permitted on one side of a 15 foot wide courtyard provided an overall minimum width of 15 feet is maintained. (4) private open space shall be provided for each residential unit and shall be no less than 50 square feet with a minimum dimension of 6 feet in each direction. (5) private open space may be substituted for additional common open space or common inte- rior space Me size of which will be equivalent to the displaced private open space. The mini- mum dimension of this space shall be 15 feet in each direction. (g) Landscape Standards (1) Where a front yard is present, one (1) 24-box size tree per 25 lineal feet shall be provided. The Likes may be placed in groups in order to achieve a particular design. (2) Six (6) 5yallon size shrubs, ten (10) one -gallon six herbaceous Derennials/shrubs and turf or acceptable dry climate ground cover shall be planted for every required tree. (3) Courtyards located Over garages shall be designed to avoid the sensation offorced podium handi. (4) Trees in the front yard shall be of small scale that do not exceed 12-1 Sr height at maturity and suitable for buih-In concrete planters or containers with a 36-Inches minimum width. (5) One 36-inch box specimen tree is required per courtyard that mesa the minimum dimen- sions. For courtyards that exceed the minimum dimensions, two or more 24-inch box smaller size trees may be substiuted for the 36inch box heir (6) Where rear yards are present, at least one (1) 36-inch box canopy tree per 30lineal feet shall be planted directly in the ground. (7) When side yards are present, at least one (1) 244nch box tree per 30lineal feet shall be plant- ed to protect privacy of neighbors. The trees may be placed in groups in order to achieve a particular design. (h): Frontage Standards (1) Entrance doors are Oriented fronting toward she courn ard(s) or the street when fronting to 0) Building Size and Massing Standards (1) Each unit shall have at least one side exposed to the Outdoors with direct access to common or private open space. (2) Buildings may contain any of three types of dwellings: flats, townhouses and lofts. (3) Units may be as repetitive or unique as deemed by individual designs. (4) Buildings may be composed of one dominant vdume. (5) A Lined Block shock comply with the height ratios established in Table Bi entitled Maximum Patio for, Each Lined Block Story. (11 foranypercentagelesslhan IW ,thepercentagemi rstothepercentagedthegrouts Boor foolodnt of the bulking area that ispersonnel!far this particular story Table story CT-5 maw. R W p d aadl lased abdO Q) Accessory Dwellings. Accessory dwellings shall not be permitted. (k) Accessory Structures. Accessory structures shall not be permlaad. 19 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT Ba City of Santa Ana, California 7 5A-41 Architectural Standards -Building Types, cont'd UN EXAMPLES ❑ Point access Dodium(walk-up ..as allowed; ❑ Walkup access Portion of Wilding Ground Floor access ---� required per frontage type standards PERMIT'TEI The varwmt Bloca art aoalybk hr Efeu ,kcr Ofied in EM diagram 1,6..suhTert b the regueemenls n Table }A, Land Ufa So,asa, MY USE 0 OFFICE OFT_ COMMERCIALIRETAKL R RESIDENTIAL Lni a dens, of ,e inNhy mne rA Mbk T I nN cm Illustrativ_ Section Configuration Diagram Below. Examples of allowed Lined Bktdssate conRgummns STREET Min OO Max per block standards I Surface ParkiTsg,Park- Once Garage. Retailer, Cinema, etc. Min Sly Ilustrative Plan Diagam- Example A STREET Min In' M. pert I I I I I I I t Surface Parking, Park -Once Garage, J6 I PettleA Cinema, Min 30' I STREET i. per blgckstandards STREET ax Per black standards I :30' l I ccess 6I I I Ilustr tiw: Plan Diagram- Examgle D 75A-42 TRANSIT ZONING CODE Ad II SPECIFIC DEVELOPMENT as Ory of Santa Ana, CERfornia T R A N S I T Z O N I N G C O D E : Architectural Standards - Building Types Illustrative Photo: Racked Dwellings i _rt WAR TERRI _ e Illustrative Photo: Stacked Dwellings with a stoop entry Illustrative Photo: Stacked Dwellings with stoops Sec. 41-2024. Stacked Dwellings Building Type. (a) A Stacked Dwelling is a structure of singe -flow, or multi -flow dwellings of similar configuration either above or below that are stacked. -� Y YY'YYYYYY"�VWY` (1) Entrance to the residential portions of the bulking shall be through a street level lobby, court- yard access, or through a combination of streeVpodlum lobby directly accessible from the street. (2) The main entrance to each ground floor unit shall he directly from the street Secondary access shall be through an elevator and corridor. (3) Access to each unit above the second keel, not accessed through a podium, Is through an ksu- nor corridor of at least 6 feet in width with recessed doors or seating alcoves/offsets at least every 100 feet. (4) Each level of the building shall have access to Me garage Via an elevator. (d) Parking Standards (1) Required parking shall be accommodated in an underground garage, surface parking, tuck under parking, or a combination thereof. (2) Dwellings shall have indirect access to their parking stall(s). le) Service Standards (1) Utility meters shall be screened from view from the street and shall not be located within any required undsope or setback area. (2) Mail boxes shall not be located In any required open space, landscape or setback areas or detract from the primary enhance to the development. 11 YY h< co m n pen spa�e shall be tt-iheieeiv.MlrjmC tleig s c x�rds. un open space shall be equal to I S percent of the lot and open to the flog. Courted hegr rsdoronapodnni Side yards may be formed as commonusnc erdion. Co0�ed do"pro the lorry all no be'leedk an 1:1 bn and 30/eel for a NS orientation. Courtyard proportions shall not be loss than 1:1 between the width of the courtyard and the height o1 the bu l ldl ng for at least 2/3 of the court's perimeter, Horizontal shifts in upper floors adjacent to a court shall not exceed 112 the height of each upper floor. (3) In ao foot wide courtyards, frontages and architectural projections are permitted on two opposing sides of the courtyard provideda minimum courtyard width of 40 feet is maintained. Frontages and archtitectural projections are permitted on one side of a 30 foot wide courtyard provided a minimum courtyard width of 30 feet is maintained. (4) Private open space shall b , provided for each residential unit and shall be no less than 50 square feet with a minimum dimension of 6 Feet In each direction. (5) Private open space may be substituted for additional common open space or common interior space, the size of which will be equivalent to the displaced private open space. The minimum dimension of this space shall be 15 fee in each direction. (g) Landscape Standards (1) front yard trees shall not exceed the height of the buildings at maturity, except at the margins of the lot where they may be used to frame and separate the building from As neighbors. The hers shall be planted at the rate of one (1) 24-irwh box free per 25 lineal feet of front yard. The trees may be placed in groups in order to achieve a particular design. (2) In the may yard, at least one (1) 364oc1, box canopy tree per 30 lineal feet shall b, punted directly in the ground. (3) Courtyards located over garages shall he designed to avoid the sensation of forced podium hardscape. (4) One W nch box specimen tree is required per courtyard that meets the minimum dimen- sions, for courtyards that exceed the minimum dimensions, two or more 24-inch box smaller size trees may be substituted for the 3&inch box tree. (5) $ix (6) Syalkm size shrubs, ten (10) one -gallon size herbaceous Perennials/shrubs and turf or acceptable dry climate ground cover shall be planted for every required tree. (6) Side yard trees shall be placed to create a par0cular sense of puce at a are of one 24r nch box free per 30 Imeal Wt. (h) Frontage Standards (1) Living rooms, dining rooms and bedrooms are oriented fronting toward the courtyard(s) or sheet Service moms are oriented backing to corridors. (b) Stoops up to 3 feet in height may be pled above subterranean parking, provided the area (0 Building Size and Massing Standards (1) Buildings may contain any of 3 types of dwellings: tuts townhouses and khs. (2) Units may be as repetitive or unique as deemed by individual designs. (3) Buildings may he composed of one dominant volume flanked by secondary ones. (4) Each unit shall have at least one side exposed to the outdoors with direct access in common or private open space. (5) A Sucked Dwellings shall comply with the height nation established in Table BT4 entitled Maximum Ratio for Each Stacked Dwellings Story. T" [11 For any pertmtage less than 100%, the percentage re ers to the percentage tithe Semo aver or ot foprint of the building area that Is permked for this pr i<uur story Ri _ RIMtlISRRn IutleMaW I Aatlad Dsseflgs Sorry f10RT bovkFbw ..-._. M agranrrd IODIa 1809s T5 {Swill Re859a 0) Accessoy Dwellings. Accessory dwellings shall rat be permitted, (k Accessory Structures. Accessory structures shall not be permitted. 4:11 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 75A-43 0) Accessoy Dwellings. Accessory dwellings shall rat be permitted, (k Accessory Structures. Accessory structures shall not be permitted. 4:11 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 75A-43 Architectural Standards - Building Types, cont'd KEY TO CONFIGURATION EXAMPLES 1 Non-walk-vp Point aaess Portion of building Ground Floor access -�� requiredP rf ArtRe type standards PERMITTED USES T t-nousfi-rs of Slacked 0w01ng1are.-Lbk for In, —,o—In din the dlag2mC Ic- pct to ore lepuk¢ments lntabk 3A, land Use Sl-dEnd, emwnwwnn*wea KEY USE erwrrawl. tte O OFEKF y C/IIT COMMERCIAL /flETAIL �l P RESIDENTIAL - ---'- •�ts+PrS'LrN_L mar IIIL IUWIve Section Conh,.I0.1 Diagram BelOV,: Enmpks of allowed Stacked DVYEIIing *. Confiquations 79 l l i I i l l LF l <I II i r i l i i s�nlln Is i PRIMARY Se _ to ribv Wn D.9.EY- Xam e T ALLEYWNERE OCCURS iI Max200 PRIMARY STREET usvatwe n iaa,,�n. F. �minr T ALLEIF"ERE OCCURS PARKING I 1 --------------------- Min 125Man 200 PRIMARY STREET illustw.. PWES lagr.ni 1.1inniNK 75A-44 TRANSIT ZONING CODE 4:12 SPECIFIC DEVELOPMENT PI City of Santa Ana, Calitornb T R A N S I T Z O N I N G C 0 D E : Architectural Standards - Building Types Illustrative Asonometdc Diagram Sec. 41-2025. Hybrid Court Building Type. (a) Hybrid Counts a building composed of two building types, the stacked dwelling and couryard housing, arranged around a courtyardls), This building type combines a point -access portion of the stacked dwelling Wilding type (access through a double loaded corridor) with a walk-up Portion of the courtyard housing building type (access directly from the street W Courtyard). The building may be designed for occupancy by retail, service, or office uses on the ground floor, wait tapper ROOS also configured for those uses or for residences 1-� Lot Width AM Depth Is . TheIDINmYm real MaA- rnumn b width and the lot depth hall be s prescribed in TahlaU-1 fRwsNNed " --' l-.> J� "�i "Jam_ (c) Access SbMards (1) The main entrance to each ground floor unit shall be directly from the street. (1) Entrance to the residential portions of the stacked dwelling element shall be through If dedicated street level lobby, or through a dedicated podium lobby accessible from the street or Through a side yard. (3) Access to each unit above the second level in the stacked dwelling element not accessed from the podium is through an interior, double -loaded corridor of at least 6 feet in width with recessed doors or seating alcoves/offsets at least every 100 feetfor other units, access shall be directly off a common courtyard or through stairs serving up to 3 dwell - IN'. (4) Elevator access shall be provided between the garage and each level of the stacked dwell- ings portion of the Wilding. Illustrative Photo: Hybrid Court access to the i (d) Parking Standards (1) Required parking shall be accommodated in an underground garage, surface parking, tuck under parking, or a combination thereof, (2) Dwellings shall bave Indirect access to their parking stall(s). let Service Standards (1) Udi ty meters shall be screened from view from The street and shall not tee located within any required landscape or setback area. (2) Mail boxes shall not be located in any required open space, landscape or setback areas or detract from the primary entrance to the development. (f) Open Space Standards (1) The common open space shall be designed as a central courtyard or Partial, multiple, separated or interconnected courtyards. This area shall equal to 15 percent of the lot and shall be open to the sky. Courtyards may be boated on the ground or on a podium. Side yards may be formed as common use gardens. 12) Minimum courtyard dimension is 40 feet when the long axis of the courtyard is oriented EW and 30 feet for a NS orientation. Courtyard proportions shall not be less than I:I between the width of the courtyard and the height of the Wilding for at least 213 of the court's perimeter. Horizontal shifts in upper floors adjacent to a own shall not exceed 112 the height as each upper floor. (3) In 40 foot wide courtyards, frontages and architectural projections are permitted on two opposing sides of The courtyard provided that an overall minimum width of 40 feet is maintained. Frontages and architectural projections are permitted on one side of a 30 foot wide courtyard provided an overall minimum width of 30 feet is maintained. (4) Private open space is required for each residential unit and shall be no less Than 50 square feet with a minimum dimension of 6 feet in each direction. (5) Private open space may be substituted for additional common open space or common interior space, the size of which will be equivalent to the displaced private open space. The minimum dimension of this space shall be 15 feel in each direction. (g) landscape Standards (1) Where a front yard is present, one (1) 24-irlch box tree pan 25 lineal feet shall be planted. The trees may be placed in groups in order to achieve a particular design. (2) Courtyards located over garages shall be designed to avoid the sensation of forced Pnd1- um hardscape. (3) Side yard trees shall be placed to create a particular sense of place at a rate of one (1) 24inch box tree per 30 lineal feet. (4) Oise 36tinch box specimen tree is required per courtyard that meets the minimum dimen- sions. For courtyards that exceed the minimum dimensions, two of more 24Anch box smaller size trees may be substituted for The 3 ftsch box tree. (5) Six (6) 5-gallon size shrubs, ten (10) one -gallon size herbaceous perennials/shrubs and tart or acceptable dry climate ground cover shall be planted for every required tree. (6) In the rear yard at least one (1) 24inch box canopy rise per every 25 lineal feet planted directly b The Wound. (7) Front yard sees that be of small scald that shall not exceed 12-15' height at maturity And are suitable for built in concrete planters or containers with a 36 minimum width. th) Frontage Standards (1) Entrance doors and social rooms, such as living rooms and dining rooms are oriented fronting toward the courtyandD) or the street when fronting one. Service rooms arc ori- ented to the degree possible backing to corridors in the Stacked Dwellings portion and to side yards, service yards and rear yards In the courtyard housing portbn. (2) Stoops up to 3 feet in height may be placed above subterranean parking, provided the area adjacent is landscaped and the stoops are scaled to the street and Wilding. (i) Building $ize And Massing Standards (1) Each unit shall have at least one side exposed to the outdoors with direct access private or common open swe. (2) Buildings may contain any of three types of dwellings: flats, townhouses and lofts. (3) Units may be as repetitive or unique as deemed by individual designs. 4:13 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 94 City of Santa Ana, CMlfomM 7 5A-45 Architectural Standards - Building Types, cont'd (a) The Stacked Dwellings portion of the building may be composed of one dominant volume Ranked by secondary ones. The courtyard housing portion o/ the building shall fdlow the courtyard housing standards. (5) A Hybrid Court shall comply with the he ght ratios established in Table III entitled Maximum Ratio for Each Hybrid Cants Story. Table PT-] Mukoum Falb of Fad HYbrld Gu rt Sbry STUDY Ground Floor is % of ground Roor by stony IODee I 1gG% "AS 50% 405k (1) For any percemage sees than 100%, the Per.emage rxars to the percentage of Hfe around! Poor footpdmt of the building ma tux b permitted for this pankWar story. (1) Accessory OwMknga Accessory Dwelkngs shall not be permitted. (ld Accessory Structures. Accessory, structures shall not be permitted. Detached garages shall be permitted KEY TO CON r i, ❑ nOnadlkup (point) access portion of building ❑ Vralkup access portion of building Ground Floor access — — — — required per frontage type standards • Minimum of l access point required tram street directly ro courtyard (total number of access points as determined by PBAI. Below: Exampks of allowed Hybrid Court site configurations PERMITTED USES The various floors of H>GM Courts are me:n'ale for the aces xenon. in the diagram below suep[l to Me r exanna lm bible 30. LarW UU lairduas. .rv�aria.0 asa.—xx KEY USE„rt 0 OFFICE j aaxix .+,ax j MP URT COMMERCIAL/RETAIL- onan f a R RESIDENML . It .1 ere M Single Court STREET Min lafl' Ma 350'_ _ I 1 r �g f Illualrabve Plan Diagram - Example A STREET Mm 160' Mae 3SV f F L F r ' Illmtrxive Plan Diagram - EKample C Illustrative Section Configuration Multiple Caen STREET w iscr Max350' f a fi < •, sE Illustrative Plan Diagram - Example B 75A-46 TRANSIT ZONING CODE a:la SPECIFIC DEVELOPMENT to City of Santa Ana, California TRANSIT ZONING CODE ;Architectural Standards -Building Types Yuoauw Photm COwryerd with fountain and Individual gar - Illustrative Phom: Courtyard with zaguan finking two court- Sec. 41-2026. Courtyard Housing Building Type (a) Courtyard Housing is a building type consisting of residences that may be arranged in bur pos- sible configurations: townhouses, townhouses over flaLL fiats, and flats over Bats. The structures are a nex to each other on one or more courts that are part or whol o n to the street (b) Lot Width and DepM. ' ell hallbei(XIN, 1. IN The mini mum and maximum lot wWth nd N I lot deoth alsaI be,, mqObed In Tabl BT-1 Term fled 8, ld'na Tvoesl (c) Access Standards (p The main entry to each ground floor unit shall be directly o8 a common courtyard or from the street. (2) Access to second story units not accessed directly from a podium shall be through stairs, serving up to 3 units. (3) Elevator access, it any, shall be provided between the garage and courtyard/podium only. (d) Parking Standards (1) Required parking shall be accommodated in an underground or aboveground garage, surface parking, tuck under parking or a combination thereof (2) Dwellings may have direct or indirect access to their parking stalys), or direct access to stalls enclosed within the garage. (a) Service Standards (1) Utility meters shall be screened from view from the street and shall not be located within any required landscape or setback area. (f) Open Space Standards (1) The common open space shall be designed as a central courtyard or partial m lusher separated or interconnected courtyards. The common opne space shall be at least 15 percent of the lot and must be open to the sky. (2) Courtyard proportions shall not be less than 1:1 between the width of the courtyard and height of the building for at least 2/3 of the coat s perimeter. Horizontal shifts in upper Boors adjacent to a court shall not exceed 1/2 the height of each upper Boor. In a project with mukiple court- yards, at least two of the courtyards shall conform to the patterns above. (3) In 40 foot wide courtyards, frontages and architectural projections are permitted on two oppos- Irg sides of the courtyard provided that an overall minimum width of 40 feet is maintained. Frontages and architectural projections are permitted on one side of a 30 foot wide courtyard provided an Overall minimum width of 30 feet is maintained. (4) Courtyards shall be connected to each other and to the public way by zaguans or pasaos (5) Private open space is required for each residential unit and shall be no less than SG square feet with a minimum dimension of 6 feet in each direction. (6) Private open space may be substituted for additional common Open space or common interim space, the size of which shall be equivalent to the displaced private open space. The minimum dltension of this space shall be 15 feet in each direction. (g) Landscape Standards (1) Landscape shall not obscure front yards on adjacent lots or the shopfront of ground floor flex space. Front yard trees shall not exceed 1.5 times the height of the porch at maturity, except at the margins of the lot, where they may be no more than 1.5 times the height of building at maturity Trees shall be planted at the rate of one (1) 36-inch box tree per 25 lineal feet of front yard. Trees may be placed in groups in order to achieve a particular design. (2)ln the rear yard, at least one (1) 24-inch campy tree per 25 lineal feet shall be planted directly in the ground. (3) One 36-inch box specimen tree is required per courtyard that meets the minimum dimensions. For courtyards that exceed the minimum dimensions, two or more 24-inch box smaller size trees may be substituted for me 36-inch box tree. (4) In courtyards over garages, one (1) 24Anch box size tree of small scale 02-15' height at maturity) or similar tall shrubs shall be used In planters with a 36' minimum dimension. (5) Side yard trees shall be placed at a rate of one (1) 24-inch boa tree per 30 lineal feet for privacy of neighbors. (6) Six (6) 5-gallon size shrubs ten (10) one -gallon size herbaceous perennials/shrubs and tuff a acceptable dry climate ground cover shall be planted for every required tree. (h) Frontage Standards (1) Entrance doors and social rooms such as win, roans and dining rooms are oriented toward Me courtyard(,) and the hunting street. Service rooms shall be Oriented backing to side yards, ser- vice yards and rear yards to the degree possible. (2) frontages and architectural projections or features such as towers, loggias and entry stairs shall not encroach into the required minimum dimension W a courtyard. (5) Stoops up to 3 feet in height may be placed above subterranean parking, provided the area adja- cent Is landscaped and the stoops are scaled to the street and building. (i) Building Size and Massing Standards (1) Buildings shall be composed of one, two and three story masses, each designed to house scale, and not necessarily representing a single dwelling. (2) 34" buildings shag be composed of single story and stacked units. In this Case, the visibility of elevators and of exterior corridors at the third stay shell be minimized by incorporation into the mass of me building. (3) Buildings may contain any three types of dwellings. Bats, townhouses, and lofts. (4) Units may to be as repetitive or unique as deemed by individual designs (5) 4 and 5-story muses shall be minimized inside courtyards and apparent m atseet homages (6)The intent of these standards Is to provide for courtyard housing projects with varying building heights. Courtyard housing shall comply with the height ratios established in Table ST-8, entitled Maximum Ratio for Each Courtyard Housino Story Table fT4F MNdnRlrn Red. eF Fads casetyeld l4wRYg sly STORY CeoVnd poor 2 l 4 S slofgraexl Boor by w I00% ,ro% aswll nif, 40% [II For any perttnta,.less than IDml the percentage relers I Me pwanUW of the ground Boor footprint a Me building area that is permhted M this particutir story. (I) Accessory Dwellings: AccessorydwelBngs"llnotbeperMtEed 4:15 TRANSIT ZONING CODE (k)Accessory Structures shall not be permitted. Detached garages shall be pennbte0. SPECIFIC DEVELOPMENT e4 City of Sent. Ana, California 7 5A-47 Architectural Standards - Building Types, cont'd KEY To wYnGUFATION Exarei,ES ❑Walkapacross Portion of Ground Flavor access required perfrontage type standards Illustrative Section Configuration Da, i r rm l,.r, .r PEPMITIED USES Theva uS Pinions ofm vaiNble forth u Ses idannfi"ni tM d.c. below rw nsE to oe reruwsen b in n[Un SA; Land Uae Standa.ds. KEY USE o OFFICE CAT COMMERCIAL I RETML R RESIN"AL Illustrative Section Configuration Dlagram:5ub[erranean Below:Examplesofaibw courtyard RousingsitecorAgwa0ons Single Court Multiple Courts STREET yl Min T30Max 250' I- .............. F : I Q T^ < 1 � f I r-- I I I 1 I I 6 Illustrative Plan Diagram- Example A STREET Min 130' Max 250 I 6.. ... ..........US n I- I c I I I I I Illustrative Plan DWgnm-Example C STREET Min 130' Max 250' 1- j .. E� i R 13� NQ 1 C S I f � I I I I I I Illustrative Plan Diagram - Example B —�.. STREET y Max 250' I I 1 a I � F I< � I � I ` d I F t I I I I mustrative Plan ulagram -trample u y Min 130' Max 250' DRIVE I-T r - r o w Q' _ 36 DRIVE ' Iua.nN.n. nn„nianem.Gv.mnlc[ 1 Required access to courtyard dew* from street (minimum I access point, total number Of access points as determined by PRq. TRANSIT ZONING CODE 4:16 SPECIFIC DEVELOPMENT 64 7 5A-48 City of Santa Anne, California TRANSIT ZONING CODE :Architectural Standards -Building Types Illustrative PhotoLhe+vork type with office and retail front M. Sec. 41.2027. Live/Work Building Type. (a) Uve Work is an integrated residence and work space (located on the ground Moor), occupied and urllzed by a single household in an army of at least 3 such structures, or a structure with at least 3 units arranged side by side along the primary Frontage, that has been designed o sbucturalty modified to accommodate joint residential occupancy and work activity. (b) Lot width and Depth. 1N minimum and nd maximum width and the I 1 m lot depth shall be laiic! in T hIeBT-1 (Permitted Building Types) (0 The main entrance to the ground floor work space shall be accessed directly from and face the street. (2) The upstairs dwelling shall be accessed by a separate entrance, and by a stair or elevator. (3) For lots without alleys, garages and services shall be accessed by a driveway B to 10 feet in width with 2-foot planters on each side when serving a private 2-car garage and 18 to 20 feet In width with 2-foot planters on each side when serving more than one private 2-ur garage. (4) Accessibility should be accommodated between a pair of units and not in the front yard to the degree possi bit (d) Parking Standards (1) At least one required parking space shall be in a garage, attached to or detached from the dwelling. (2) Additional required parking spaces may be enclosed, covered or open. (e) Service Standards (1) Services (including all utility access, aboveground equipment and trash contamersl shall be located on an alley when present or in the rear of the lot for those lots without alley -access. (f) Open Space Standards (1) For all buildings, except for hose with a tuck -under garage, the private open space shall be in the rear yard of each unit. The private open space shall be no less than 15%of the area of the lot or portion of the lot allocated for the unit. The private open space shall be of a regular geometry and open to the sky. The minimum dimension of each rear yard shall be 15 feet. (2) For buildings with tuck -under garage, one primary common open space of a regular geom- etry shall be provided. This common open space shall he equal to 15 Percent of the lot and shall be open to the sky. The minimum dimension For the common open space shall be 30 feet in each direction. Additionally, private open space shall be provided for each unit The private open space shall be equal to 50 square feet per unit Private open space may be sub- stituted for additional common open space or common interior space, the size of which will be equivalent to the displaced private open space. The minimum dimension of the substi luted common open space shall be 15 feel in each direction. . . ■ • • Bit Ma U UM ■ (g) Landscape Standards (1) Landscape shall not obscure front yards on adjacent lots or the shopfront of ground Boor flex space. Front yards trees shall not exceed 1.5 times the height of the porch at maturity, except at the margins of Me lot where they may be no more than 13 times the height of building .. at maturity, Trees shall be planted at the rate of one (1) 3t mh box tree per 25 lineal feet of front yard. Trees may De placed In groups in order to achieve a particular design. (2) In each unit', rear yard, at least one (1) 244nch canopy time shall be provided for shade and J Privacy.(3) Side yards trees shall be placed a rate of one (1) 24-inch box tree per 30lineal feet to protect the privacy of neighbors. -V (4) Six (d) 5gallon size shrubs, tan (10) one gallon size herbaceous perenniab/shrubs and turf o acceptable dry climate ground cover shall be planted for every required tree. Mushauve Photo: live -work type with shopfront Frontage (h) Frontage Standa is (1) Each live/work unit shall be designed so that social areas (e.g., living room, family room, din- ing room, etc), rather than sleeping and service roons are oriented toward the fronting street or to the courtyard. (i) Building Size and Massing Standards (1) Buildings shall be composed of 2 or 3story volumes in compliance with the standards for the aPplcabk zone. (2) Buildings on toner lots shall be designed with two front facades. (3) The minimum unit Frontage shall be 21 feet. (4) A five/work sh13 comply with the height rations established in Table ITT-9, entitled Maximum Rath for Each LKwWork Story. Table BT-9 laatllwm RMb d each Llve/1Vark Slwy AR Zones Except UN-1 A uNFZZ&NN; 3terY faountl Noon 1 3 lom6 1g0% Igo% wd, U IALVQZa Bporby kry 100% ao%[ll f0N [t) For any percentage leis Man llRnb, the percentage refers to Me percmtagedMe ground floor footprint dthe Wilding area Mat is aenitted b [his partkukr story 0) Accessory Dwellings. Accessory dwellings shall not be permitted. (k) Accessory Stmctums. Accessory structures shall be permitted. 4:17 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Sant. Ana, California 7 5A-49 Architectural Standards- Building Types, cont'd KEY TO CONFIGUMMN EXAMMFs 1 ❑ Walk-up access portion of building Ground Floor access --- required perfrontage type standards 8ebw: Examples of allowed DVebWork type site configurations T ❑ 8 Street Illustrative Plan Diagram: Street access -Example D PERMITTED 11 to The various floors of bye Work building, are available for the uses identified In the diagram below subject or the requirements in table IA: Land Use Standard, Or USE O OFFICE CRT COMMEKIM./kETML Uppef dories as F - RESIDENTIAL rpermitted byaone and table BT-9 Illustrative Sedinn Cnfigu ration Oiagram Alley Access T ❑ F Min 21 Street Illustrative Plan Diagramizample A Al�a� T f �:Man 75Max 125 1 Street Illustrative Plan Diagram- Example B Alley Access 8 F -EMIn75' Max125 Street Illustrative Plan Diagram- Example C 75A-50 TRANSIT ZONING CODE 4:18 SPECIFIC DEVELOPMENT to City of Santa Ana, CaRbmb TRANSIT ZONING CODE : Architectural Standards -Building Types Illustrative Photo: Rowhouse building with stoop frontages Illustrative Photo: Rowhouse building with stoop frontages Sec. 41-2028. Rowhouse Building Type (A) Rowhouse is An individual structure on a parcel wish a private rear yard and individual garage Assessed from an alley, occupied by one primary residence in an army Of at least 3 such rtructures as structure of 3 multiple townhouse unit types Arranged side by side along the primary frontage. (b) Lot Width and Oepth. The min mum and maximum lot oth shall be as prescribed in TabigBI-I (Perm tied Building Tyces). .r ,u.������� fd Access Standards (1) The main entrance to each unit shall be accessed directly from and face the street (2) Garages and services shall be Admitted from An alley. (3) Accessibility should be accommodated between a pair of units and not In the front yard to the degree possible. (d) Parking Standards (I) Required mUdemial unit Parking shall be In A garage, which may be attached to or detached from the dwelling. (2) Additional required parking spaces may be enclosed, covered or open. (a) Service Standards (1) Services, including all utility access, aboveground equipment and trash containers shall be located on an alley when present or on the rear of the lot for those without alley access. (f) Open Space Standards (1) Private open space shall be located in the rear yard of each unis. The private open space shall W rw less than 15%of the area of the lot or portion of the lot allocated for the unit The ph - vote open space shall be of a regular geometry and open to the sky. The minimum dimension for the private open space shall be 15 feet in each direction. IS) Landscape Standards (1) Landscape shall rot obscure front yards on adjacent Inds. Front yards heel shall not exceed 15 times she height of the Porch at maturity, except at the margins of the lot where they may be no more than 1.5 times the height of building at maturity. The trees shall be planted at the rate of one (1) 3&ineh box tree per 25 lineal feet of front yard. The trees may be placed in groups In Order to achieve a Particular design. (2) At least one (1) 24-imin canopy tree shall be provided in each Private open space for shade and piwacy. (3) Side yards Veer shall be placed a rate of one (1) 24inch box tree per 30 lineal feet for Privacy of neighbors. (4) Six (6) 5Kgallon sue shrubs, ten (10) one -gallon size herbaceous perennials/shrubs and turf or acceptable dry climate ground cover shall nd planted for every required free. (h) Frontage Standards (1) Each rowhous , ground level shall be designed w that social areas such as the living room, family room, dining room, rather than sleeping and service rooms, are oriented toward the fronting street Or to the courtyard to the degree Possible. (i) Building Size and Massing Standards (1) Buildings shall be composed of 2 or 3-story volumes in compliance with the standards for the applicable Sons, (2) Buildings on corner lots shall be designed with two front facades. (3) Each rovvhouse building shall have direct access to yards. (4) In a 3-story Wilding, a townhouse dwelling may be stacked over a ground floor flat. In this case, the flat shall be accessed by Its own hunt door at the frontage, and the townhouse dwelling shall be Accessed by a separate front door and a stair. (5) The minimum unit frontage shall be 21 het. (61 A rowllouse shelf comply with the height ratios established in Table ST-10, entitled Maximum Ratio for Each Rowhouse SMry. Table lrt-to Maximum RadopfeAcA Rowhouse Seery '' ARZaner Except UN-1 A UN-2 Zones Eery Ground floor 2 3 Moor by Nary 100% 10096 1001s Lai a UIN Zones I0036 1 tlMyll SO% 'Via 111 FOr ally percerRage bzthan to09k the pen:enugereMsto UN percemagedthe _.I 1 r` tE I11 r aleilaR �' - R1f ' +y I 1 +iiii R • 9nopnd floor bapim of the bulMing arts Nat N pannirted br Nis particular story. j) A cessory DweMngc Accessory dwellings are not permitted, except In compliance wish SAMC lotion 41-1Sit, Second Dsvellirsg Units. (it) Accessory Structures: Accessory structures are Permitted. Illustrative Photo: Rowhouse Building with direct sidewalk access 4.19 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 94 City of Santa Ana. California 7 5A FF51 Architectural Standards - Building Types, cont'd NEYTOCONFIGORATION'-NANPLES Walkup access Portion of building Ground Floor access required Perfrontage type standards Tap Row: Enmples of allowed Rowhouse site configuratiwN Bottom Row: E,amples of accomodadng Accesdbaty Per Standard (dUl. STREET I IG0 to Zoo I� see ab __ _ 4 ` va2".. 51aMaraK e+. r— 0-- PERMITTED USES The varimaFarm of R.housee are available for the uses ldennfied In the diagram helm,, Subject to the requirements In table 2A land Use Standards. KEY USE 0 OFFICE CAT C011 It I It nr••,-/. upper staries as permitted by sore may-- and table BT-10 t 1�1--H I � nbshative Section Configwatioo Diagram sIREEi Bh h see 24'auess !�' nandams - E ; T ........... L— Illustrative Plan Diagram - Wroole 8:6 Rowhouses in I buildinu r - 1 ,a H 51a 14'acU � y IanaamK e Lyea- I 7k�a I � misoled site plan 75A-52 TRANSIT ZONING CODE 430 SPECIFIC DEVELOPMENT da City of Santa Ana, Carl ... I. TRANSIT ZONING CODE : Architectural Standards -Building Types Illustrative Photo. Tuck -under with stoop frontage Illustrative Photo: Alley providing IP—,P and garage aaess 11 7 e / t fl Illustrative Photo. ArcMtMure of two separates h6uMer tuiM- ingx combined at the alley access Hat separates the twt dribirgs Sec. 41-2029. Tuck -Under Housing Building Type. (a) Tuck -under housign is an individual structure on a parcel with no private rear yard and where its garage is tucked under the rear of the houw and accessed by an alley. The structure is occupied by one primary residence arranged with at least 4 such structures or at least 4 multiple townhouse (b) Lot Width and Depth. feet; The minimum and maximum lot Width end the Mrn,m,M lot depth shall be u, ,ibd in Tabli (Perm Third Build no Ttuell (1) The ..in entrance to each unit adjacent to a street shall be directly from and face the street The main entrance to all other units shall be from a courtyard. (2) Garages and services shall be accessed from an alley. (3) A back entry from the alley, and beside each garage shall be required for each unit. These entries are to be set back into the lot at a minimum distance of 5 feet so as not to be flush with the alley -facing garage doors. (4) Buildings at a street caner may span across the alley provided emergency access is main- tained and all required clearances are maintained. (5) Accessibility should be accommodated between a pair of units and not in the front yard to the degree possible. (it) Parking Standards (1) Required residential unit parking shall be in a garage that is attached to the dwelling. (2) All garages shall be accessed from a parking court separate but adjacent to the alley right way. (3) The garage for the dwellings at the end of the structure shall not a accessed directly from the alley, They should be access from parking Court. (4) Additional required parking spaces may be enclosed covered, or open. (el Service Standards (a) Services, including all utility access, aboveground equipment am trash containers shall be located on an alley when present or on the rear of the lot for those without alley access. (f) Open Space Standards (1) One primary common open space of regular geometry is required. This area shall be equal to 15 percent of the lot and shall be open to the sky. The common open space may be located on the ground or on a podium. The minimum dimension for this area shall be 30 feet in each direction. (2) Private open space shall be provided for each residential unit. The private open space shall be no less than 90 square feet with a minimum dimension of 6 feet in each direction am shall be open t0 the sky. (3) Private patios are permitted in front yards, subject to encroachments permitted! per zone, in building interiors, and on upper floors (4) Single loaded courtyards adjacent to alleys or interior lot lines shall be at least 20 feet in width. The length of such courtyard shall equal to the length of the building frontage. (5) Up to 50 percent of the private open space may be substituted for additional common open space or common interior space, the size of whi will be equivalent to the displaced private open space. The minimum dimension of this space shall be 15 feet in each direction. (9) Landscape Standards (1) Landscape shall not obscure front yard on adjacent lots Trees shall be planted at the rate of one (1) 36-inch box tree per 25 lineal feet of front yard. The trees can be placed in groups in order to achieve a particular design. (2) Where rear yard setbacks are present at least one (1) 2Hnch campy tree per unit shall De provided for shade and privacy. (3) Side yard trees shall be placed at a rate of one (1) 24-inch box tree per 30 lineal feet for privacy of neighbors. (4) Six (6) 5-gallon shrubs, ten (10) one -gallon size herbaceous perennials/shrubs and turf or acceptable dry climate ground cover shall be plantM for every required tree. (h) Frontage Standards (1) Each dwelling's ground level shall be designed so that social areas such as the living room, family room, dining room rather than sleeping and servNe rooms, are oriented toward the fronting sheet to the degree possible. 0) emitting Size and Massing Standards (1) Buildings shall De composed of 2 or 3-story volumes in compliance with the standards for the applicable mine. (2) Buildings on corner lots shall De designed with two front facades. (3) Each building shall maintain setbacks from property lines and in compliance with the stan- dards for the applicable zone, providing as mutt, direct access to yards as possible. (4) The minimum unit frontage shall be 21 feet. (5) A tuckunder shall comply with the height ratios established in Table BTA 1. entitled Maximum Table Rsl MatlrMeN AMM of eAdh rMdhwM spry Story Ground Flee 2 7 9k aground Boor by "hey 1005s "UM Maas IU Taranypercentage lessthanathat is ppercentage refersrtthe story. eNMe grate lbw footprint of the budding area that is permmed for Mis particular story. 0) Accessory Dwellings Accessory dwellings shall not be permined. (it) Accessory Structures Accessory structures shall not be mounted. 421 TAANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Sent. Are, Ca@ornia 75A-53 Architectural Standards -Building Types, cont'd NFY TO CONFI(WRATICN E NUPLES ❑ Walkup access portion of building Ground Floor aceess — — — — required per frontage type stamdards(section Bolow:Examples of a6owed I d clar typedh con6gorMbns PERMITTEDUSES The rurkan fi.1s of Tuak Under housing me available for she uses identified in thediagram below subjeatto the requirements in Table 2A, Land Use Standards. Upper stories KEY USE �as permittetlb mire and Fault O OFFICERT 11 LINE COMMFNMVflETMI e R RESIDENTIAL Al ss 1oc'It1n"m M 2, '^ 1 1 I 1. 2 3 14 i 1 � ; 2 , 3 i & i 4 i Il l u stralive Plan Diagram: With drive One illurtnmive Section Configuration Diagram & 1 2 3 4 Alley 11 2 3 1 3 1�L—L- F n �3 MmW Maa250' L �I E� Primary Street Illustrative Plan Diagram: S units in i Willing. Alley 1�34 1 11 1 F Min 94' Max 25Y Primary Street Illustrative Plan Diagrams 6 units in I building wile Damao. Alley + 1 1 1 1 1 2 3 4 S 6 7 6 9 10 F r 1 I N -1 Max 250' 6 Primary Street Illustrative POn Diagram. 10 unitsin 2 buildings 75A-54 TRANSIT ZONING CODE 4; SPECIFIC DEVELOPMENT 84 City of Santa An., California TRANSIT ZONING CODE :Architectural Standards -Building Types Illustrative Axonometric Diagram Illustrative Photo: Individual houses fronting the court Sec41-2030. Bungalow Court Building Type (a) Bungalow court is a configuration of single units arranged around a common, shared courtyard that is wholly open to the street. The Individual buildings are arranged next to each other to form theb n al w urt builDin t e. On It width and Depth. . The minimum and m_r rman lot width Andth lot him all be cubed In TaWeBT4 IPxmitted BWld'na Tvoesl. (c) Access Standards (1) Entrance to units shelf be directly from the front yard or from the courtyard. (2) Where an alley Is not present parking and services shall be accessed by a driveway 8 to 10 feet wide, with 2-loot planters on each side when serving a private 2-car garage, and 18 to 20 feet In width with 2-foot planters on each side when serving more than one private 21ar garage. (3) On a corner lot without access to an alley, parking and services shall be accessed from the side street (d) Parking Standards (1) Required residential unit parking shall be within individual garages, which shall contain up to four cars. (2) Garages on comer lots without alkyl shall front onto Me side street and shall have 1 or garage doors and driveways no more than 8 feet wide that are separated by planters at least 2 feet wide. (3) Garages shall not front the primary street. (4) Additional required parking spaces may be enclosed, covered, or open. un Service Standards (1) Servkes, Including all utility access, aboveground equipment and trash containers shall be located on an alley when present. (2) Where an alley is not present, utility access, above ground equipment and trash containers shall be located in a side or rear yard, at least 10 feet behind the front of the house, and be screened from view from the street with a hedge or solid fence. (1) Open Space Standards (1) The common Open space shall be designated as a central courtyard. This area shall be at least 15 percent of the lot of a regular geometry and shall be open to the sky. (2) Minimum courtyard dimensions are 40 feet when Me long axis of the courtyard is oriented East/West and 30 feet when the courtyard is oriented North/South. (3) In 40 foot wide courtyards, frontages and architectural projections are permitted on two opposing sides of the courtyard provided that an Overall minimum width of 40 feet is win - tained. Frontages and architectural protections are permitted on one side of a 30 foot wide courtyard provided an overall minimum width of 30 feet is maintained. (4) Each dwelling shall have a private open space of at least 150 square feet which may be locat- ed in a side yard, rear yard, or adjacent but separate from the courtyard. (5) The private open space shall be at least 10 feet in each direction and enclosed by a fence, wall or hedge. (6) Up to SO percent of the private open space may be substituted for additional common open space or common interior space, the size of which will be equivalent to the displaced private open space. The minimum dimension of this space shall be 15 feet in each direction. (7) Each unit shall be separated from the adjacent dwelling by At least 10 feet. (8) Porches and stoops may encroach into the required yard setbacks as permitted by the urban standards for Me zone. (9) Private patios are permitted In any yard. (g) landscape Standards (1) Landscape shall not obscure front yards on adjacent lots. From yards trees shall not exceed 1.5 times the height of the porch at maturity, except at the margins of the lot where they may be no more than 1.5 Lanes the height of building at maturity, The trees shall be panted at the rate of one (1) 3 imh box tree per 25 lineal feet of front yard. The trees may be placed in groups in order to Achieve a particular design. (2) At least one (1) 24-Inch canopy tree shall be provided in each unit rear yard for shade and on- vacy. (3) Side yards trees shall be paced a rate of one (I) 24-Inch box tree per 30 lineal feet to protect the privacy of neighbors. (4) Six (6) 5-gallon size shrubs, ten (10) one -gallon site herbaceous perennia Wshrubs and turf or acceptable dry climate ground cover shall be panted for every required tree. (5)One 36 och box specimen tree Is required per courtyard Mat meets the minimum dimensions. Above and to the left: illustrative Photos: Individual houses fronting a court with the entry porch and/or stoop encroach- ing Into the common space. 4:13 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 04 City of Santa Ana, California 75A-55 Architectural Standards - Building Types, cont'd (h) Frontage Standards FdA kaactyMakhgs.teeddlferlliefraWbedlsays�sonlapipdeleossJNblclsttle bsia}r�e,tl�iy room, and dining may Ireovt9tMetMm livelsorgushmoartRe.rooms, are oriented toward the fronting street or to Me courtyard. ul Building Size and Massing Standards (1) Buildings shall be composed of one of two story volumes and massed as houses. (2) Building elevations abutting side yards shall be designedto provide at least ore honcontal plane break of at least three (3) feet and one vertical break Of m West two (2) feet (3) Dwellings within the buildings may be flats or towntwuses. (4) Buildings on corner lots shall be designed with two front facades. (5) A Bungalow Court shall complywith the height ratios established in Table BT-12, entotled Maximum Bata for Each Bungalow Court Story, _-.... Table Br-12 Maximum Ratio of each luryalose Cam Story Ground Floor 2 %af ground lbw by sbry lllOte Nlf(11 orany Percentage lessthan %. the yementage refers to the percentage of the grountl floor l000pnnt of the building area that h permitted for this particular story. D) Accessory Dwellings: Accessory dwellings shall not be permitted. (k) Accessory Structures: Accessory structures shall be Permitted. Below: Examples of allowed bungalow -court type site configurations 04n= o D 1 1 F 1 1 1 1 1 1 1 1 1 ++j 1001a190' Primary Street IRustraNve Plan Diagram: Street Access Alley ID1 1 rL^I u 1 1 1 1 IN to IW 1 1 1 1 i Vrimary Strnel thistrafiye Plan Diagram: Alley Access PERMITTED USES The various floors of Bungalow Courts are available for the uses identified In thediagram below subject to Me requirement in Table2A, land Use Standards. NEV _ USE Uppersloriesas Permitted O _ OFFICE r by Ico^rmaandI table Bi P RESIDENTIAL Illustrative Plan Diagram: Non Alley Access illustrative Section ConM1guiation Diagram KEY TO CONFIGURATION EXAMPLES Walk-upaccess Portion of Ground Floor aces — — — — required per frontage type standards (Section Space. 75A-56 TRANSIT ZONING CODE 4:24 SPECIFIC DEVELOPMENT 84 City of Santa Ana, California TRANSIT ZONING CODE :Architectural Standards -Building Types Illustrative Photo: Duplex with Porch Frontage Illustrative Photo: Duplex with hontyard and porch frontage Nkubadve Photo: QuadPlex with stoop frontage Sec. 41-2031. Duplex, Triplex, and Ouadplex Building Type (a) Duplex, triplex, and quedpiex are muitiple dwelling types that are architecturally presented as large single-family houses In their typical neighborhood setting. Such buildings may be used for residenBa, office, retail or in combination as Permitted by the applicable zone. (b) Lot Width and Depth. .Themin,and maximum ld "Ed Buildina Terser). width and the en nunum lot depth shall be as prescribed! inTableRT-1 (Perm, (cl Access Sean ar (1)The main entrance to each ground floor unit shall be accessed directly from and face the street Access to second floor units shall be by a stair, which may be open or erdosed but shall not face the street. (2) Where an sky Is rot present parking and services shall be accessed by a driveway 8 to 10 feet wide with 2-foot planters on each Ode when serving a Private 2-or garage and /8 to 20 feet in width with ]-foot planters on each side when serving more than one private 2-car garage. (3) On a corner tat without access to an alley, Parking and services shall be accessed from the side street (d) Parking Standards (1) Requhed residential parking shall be within individual garageswhich shall contain up to four cars (2) Garages on caner lots without alleys may front onto the side street only N provided with 1 ear garage dons and driveways up to 8 feet wide that are separated by planters at least 2 feet wide. (3) A street facing garage may accommodate no more than 2 cars and shall have 1 ear garage doors and driveways no more than 8 feet wide that are separated by planters at least 2 feet wide. (4) Additional required parking spaces may be enclosed, covered or open. (a) Service Standards (1) Where an alley is not present services including. utility access, above ground equipment and trash containers shall be located at least 10 feet behind the front of the house, and be screened from view from the street with a hedge or solid fence. (p Open Space Standard, (1) One primary common open space of regular geometry is required. This area shall be equalto 15 percent of the lot shall be open to the sky and may be located on the ground or on a podium. The minimum dimension for the common open space shall be 15 feet in each direction. (2) Private open space is required for each ground floor residential unit The private open space shall be no less than 150 square feet with a minimum dimension of 10 het in each direction, enclosed by a fence, wall or hedge and open to the sky, (3) Porches and stoops may encroach into a required yard, as specified in the Urban Standards for the Zone. (g) Landscape Standards (I) Landscape shall rat obscure front yards on adjacent lots. Front yards trees shall not exceed 1.5 times the Might of the porch at maturity, except at the margins of the tat, where they may be no more than 15 times the height of building at maturity. The trees shall M planted at Me rate of one (1) 3trirrch box tree per 25 lineal feet of front yard. The trees may M placed in groups m order to achieve a particular design. (2) In the rear yard, at least one (1) 244och canopy tree shall M Provided for shade and privacy. (3) Side yards trees shall M placed a rate of one (1) 2a-inch box tree per 30 lineal feet to protect the privacy of neighbors. (4) Six (6) 51allon size shrubs, ten (10) one -gallon size herbaceous perennials/shrubs and turf or acceptable dry climate ground cover shall be planted for every required thee. (h) Frontage Standards (1) Each dwelling's ground level abutting front yards shall be designed ro that social areas Such as the living room, family room, dining room rather than bedrooms and service morns are ori- ented toward the fronting street to the degree possible. (2) On corner lots, entrances to triplex and quadplex dwellings shall M located on both sired frontages. (0 Building Size and Massing Standards (1) Building elevations abutting side yards shall M designed to provide at least one horizontal plane break of at least 3 feet, and one vertical break of at least 2 feet. (2) Buildings on corner lots shall M designed with two front facades. (3) Buildings shall M massed as large houus, composed principally of 2-story volumes, each designed to house sole. (4) Dwellings within buildings may M flats or townhouses. (5) Duplex, Triplex, and puadplex shall comply with the height ratios established in Table BT-13 Table R-13 OPrex arory Maxlmwn Barb of each Duplex,fall" nd Ouadplex Stay Crowdibor Z 3 %ulpaasd 1001s 1SW1) 4p% Hoer by story Ito sod envrfoontayekssthandinga that is permitted emp ticulasurry. ground Moor motldnt W she bulking area that is permmed for M'n panicubr story. 0) Acceseery Dwellings. Accessory dwellings shall not be permitted. 425 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT 84 City of Santa Ana, California 7 5A-57 Architectural Standards -Building Types, cont'd ❑ walk-up access portion of building Ground Floor access rY,o,rsd,rfrontage is,- "anda'dt Bebw:Examples ofallowed duplex/triplex/quadpkx site configurations. P[RMI I TED Dff5 The various Floors of duplevtnple. Iquadplexes are avaJablefor the uses Identified in the diagram below object to the requirements in table ZA Land Use Standards. KEY USE R RESIDFNTmI Upper stories as allowed by rare and table 47 dT-13 Illustrative Section Configuration Diagram of a triplex Upperstorias as permitted by r mare and false ` 6T-13 Illustrative Section Configuration Diagram of a quadpkx Alley Alley I i I a 1 1 I a 1 i Z 8 3 1 i s. s Min 50' a.� �t Max 12s Mln 50 �� ye Max 125' P,imar St;aet Irl niryStreet Illustrative Plan Diagram of a triplex: Alley access upper stories as r allowed by zone +� and table Bi-13 va- Illustrative Section Configuration Diagram of a duplex Alley i . r Kill I s- Q Mln 50 LMax 125' pinal Street Rlustratke Plan Diagram of a duplex Alley access Illustrative Plan Diagram of a quadpkx Alley access Jpper stories as Hewed by zoo aA table RT-13 aRo w.w Illustrative Seaton Configuration Diagram of i mial. � r Min 50'a; '1Max 125 Priinar SOW IllustraMve Plan Dlagwm of a duplex Street Access 75A-58 TRANSIT ZONING CODE 426 SPECIFIC DEVELOPMENT as City of Santa Ana, California TRANSIT ZONING CODE : Architectural Standards -Building Types Matter" Photo: Sligle dwellirsg with hag yard frontage Illustrative Plato: Single dwelling with hontyard frontage Muslim ore Phu $1,40 dwellings with frontyard homage SeC41-2032. House Building Type. (a) House is a structure occupied by one primary residence that also accommodates commercial and office uses as permitted allowed. Such buildings may be used for residential, office, retail or in combination as pemgtted by the applicable zone. 1yyYYY YYVY-Y"I-r-rYYY' (1) The main entrance to the house shall Ise accessed directly from and face the street. (2) Where an alky n but present, parking and services shall he accessed by of a driveway 8 to 10 feet wide, and with 2-foot planters on each side. (3) On a corner of without access to an alley, policing and services shall be accessed from the side street. (d) Parking Standards (1) Required residential parking shall be within a garage. (2) Street facing garage may accommodate no more than 2 cars side by side or 3 cars in a tandem configuration. (3) An alkyaccessed garage may accommodate up to three cars side by side. (4) Additional par4lrsg may be provided in the driveway. (5) A street -facing garage shall have 1-car garage doors and driveways no more than 8 feet wide that are sepersted by planters at least 2 Net wide. (a) Service Standards (1) Where an alley is hot present, services including utility access, above ground equipment and bash containers shall be located at least 10 Net behind the front of the house and be screened from view from the street with a hedge or sdld fence. (f) Open Space Standards (1) Private Olsen space shall be located in the rear or side yard and shall be no less than 15 per- cent of the area of the lot of a regular geometry and open to the sky. The minimum dimen- sion for this area shall be 15 feet in each direction. (2) At least one side yard shall be designed to pfovlde an open area no less than 10 feet by 10 feet. (3) Porches and stoops may encroach Into a required yard, as specified by the zone requirement SectiM. (g) Landscape Standards (1) Landscape shall not obscure front yards on adjacent lots. Front yards trees shall rot emeed 1.5 times the heght of the Porch at maturity, except at the margins of the lot where they may be rig more than 13 times the height of building at maturity. Trees shall be planted at the ,are of we (1) 36-inch box tree per 25 lineal feet of front yard. Trees may be placed in groups in Older to achkve a particular design. (21 In the rear yard, at least one (1) 24-Inch canopy time shall be provided for shade and privacy. (3) Side yard trees shall be planted in required yards a rate of one (1) 241nch box tme per 25 an- eal feet to protect the privacy of neighbors. (4) Six (6) 5-9a11on shrubs, ten (10) oneyallon size hwbxceous peren rrals/shrulas and turf or acceptable dry climate ground cover shall be planted for every required tree. (h) Frontage Standards (1) A houses ground level shall be designed so that social areas such as the living roan, family room, dining room rather than sleeping and service rooms, are oriented toward the fronting street. (i) Building Size and Massing Standards (I ) Building elevations abutting side yards shall be desgrsed to provide at least one horizontal plane break of at least three feet, and one vertical break of at least two feet. (2) Houses on corner lots shall be designed with two front facades. (3) Buildings shall W composed of one and/ or two story volumes, each designed to house scale. (4) A house shall comply with the height ratios established in Table BT-14, entitled Maximum Ratio for Each House Story. Table IFF14 Maximum Falb of eacA Noae sorry CileYM FbOl 2 %cogrwaw lore% foyer by tray W%Iil PI For any percentage less than IDO%, the percentage refers to the percentage of the ground Igor footprint of the Wilding area that is permitted for this particular story. W Accessory Owellinga Accessory dwellings arc pefmRed subject W the roquk nets of Sec 41.194 - second dwelling units. (k) Accessory Structures, Accessory structures are permitted. 422 TRANSIT ZONING CODE SPECIFIC DEVELOPMENT a4 City of Santa Are. California 7 5A-59 75A-60