HomeMy WebLinkAbout2005-114 - Reduce the Floor Plan Configuration for the Property Located at 2823-2929 West Edinger Avenue
KO-11/29/05
RESOLUTION NO. 2005-114
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
SANTA ANA APPROVING AND ADOPTING THE
MITIGATED NEGATIVE DECLARATION AND MITIGATION
MONITORING PROGRAM (ENVIRONMENTAL REVIEW NO.
2004-198); APPROVING TENTATIVE TRACT MAP NO.
2005-07 AS CONDITIONED, VARIANCE NO. 2005-53 AS
CONDITIONED FOR A REDUCTION IN THE NUMBER OF
REQUIRED PARKING SPACES, VARIANCE NO. 2005-54 AS
CONDITIONED TO EXCEED THE MAXIMUM ALLOWABLE
HEIGHT, VARIANCE NO. 2005-55 AS CONDITIONED TO
REDUCE THE REQUIRED FRONT YARD LANDSCAPING
AND VARIANCE NO. 2005-56 AS CONDITIONED TO
REDUCE THE FLOOR PLAN CONFIGURATION FOR THE
PROPERTY LOCATED AT 2823-2929 WEST EDINGER
AVENUE
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SANTA ANA AS
FOLLOWS:
Section 1. The City Council of the City of Santa Ana hereby finds, determines
and declares as follows:
A. Applicant is requesting to develop 44 townhomes at 2823-2929 West
Edinger Avenue. To allow the proposed project, the applicant is
requesting approval of a General Plan Amendment from Low Density
Residential (LR-7) to Medium Density Residential (MR-15). Additionally,
the request includes a tract map in order to consolidate six existing
parcels and create 44 residential units for condominium purposes. As
proposed, variances are required to allow a reduction from the City's
townhouse development standards for parking, height, front yard
setbacks, and ground floor access.
B. The Mitigated Negative Declaration and Monitoring Program,
Environmental Review No. 2004-198, General Plan Amendment No.
2005-01, Tentative Tract Map No. 2005-07, Variance No. 2005-53 from
number of required parking spaces, Variance No. 2005-54 from maximum
allowable height, Variance No. 2005-55 from required front landscaped
setback, and Variance No. 2005-56 from floor plan configuration, came
before the Planning Commission of the City of Santa Ana for a duly
noticed public hearing on November 14, 2005. The Planning Commission
Resolution No. 2005-114
Page 1 of 31
unanimously voted to recommend that the City Council approve the above
referenced actions.
C. On December 5, 2005, the City Council of the City of Santa Ana held a
duly noticed public hearing on Mitigated Negative Declaration and
Monitoring Program, Environmental Review No. 2004-198, General Plan
Amendment No. 2005-01, Tentative Tract Map No. 2005-07, Variance No.
2005-53, Variance No. 2005-54, Variance No. 2005-55, Variance No.
2005-56.
D. Tentative Tract Map No. 2005-07 consolidates the six existing parcels into
one comprehensive development site and creates a condominium
subdivision for each of the 44 town homes. The City Council of the City of
Santa Ana determines that the following findings have been established:
1. The proposed project, as conditioned, and its design and
improvements are consistent with the Medium Density Residential
land use designation of the General Plan and are otherwise
consistent with all other elements of the General Plan and any
applicable specific plans.
Tentative Tract Map No. 2005-07 is consistent with the land
use designation and density prescribed in the General Plan
and will have no adverse affect on the surrounding land uses
in the area.
2. The proposed project, as conditioned, conforms to all applicable
requirements of the zoning and subdivision codes, as well as other
applicable City ordinances.
The proposed subdivision conforms to the minimum
condominium requirements, as well as meets the letter and
intent of the State of California Subdivision Map Act
provisions. Tentative Tract Map No. 2005-07 is in keeping
with the provisions of the site plan review (Development
Project No. 2004-73) and Chapters 34 and 41 of the Santa
Ana Municipal Code, all of which pertain to the subdivision of
land and development standards for the site.
3. The project site is physically suitable for the type and density of the
proposed project.
The project site consists of approximately 3.1 acres of land
within the Two-Family Residence zoning district. The
proposed subdivision contains adequate frontage and lot
size for the development. The parcel and its location have
been determined to be capable of supporting the type and
Resolution No. 2005-114
Page 2 of 31
density of the proposed project. There are no physical
constraints on the site to preclude development.
4. The design and improvements of the proposed project will not
cause substantial environmental damage or substantially and
avoidably injure fish or wildlife or their habitat.
There are no wetlands or unusual flora or fauna on or
around the project site. No development surrounding this
site will be substantially affected by this proposal. Mitigated
Negative Declaration No. 2004-198 has been prepared for
the proposed project, identifying potential impacts and
mitigation measures aimed at reducing any environmental
impact associated with this project.
5. The design or improvements of the proposed project will not cause
serious public health problems.
The proposed infill development is for a 44 unit residential
townhome development and will be in compliance with all
regulations and conditions specified in the Santa Ana
Municipal Code with the exception of parking, height,
setbacks and access. The proposed variances will not
cause any serious health impacts or health problems.
Additionally, mitigation measures such as sound rated
windows and doors will be incorporated into the buildings to
avoid any noise impacts.
6. The design of improvements of the proposed project will not conflict
with easements necessary for public access through or use of the
property within the proposed project.
There are no easements that would affect the use or
development of this site. Approval of Tentative Tract Map No.
2005-07 will not create conflicts with the easements necessary
for public access through the property, as no such easements
currently exist.
E. Santa Ana Municipal Code Section 41-282 requires off-street parking for
townhomes to be provided at a rate of two parking spaces per unit plus
two guest spaces. The applicant is requesting approval of Variance No.
2005-53 to reduce off-street requirements by 34 parking spaces. The City
Council determines that for Variance No. 2005-53, the following findings,
which must be established pursuant to Santa Ana Municipal Code Section
41-638 in order to grant a variance from the provisions of the Santa Ana
Municipal Code, have been established:
Resolution No. 2005-114
Page 3 of 31
1. That because of special circumstances applicable to the subject
property, including size, shape, topography, location or
surroundings, that the strict application of the zoning ordinance is
found to deprive the subject property of privileges not otherwise at
variance with the intent and purpose of the provisions of this
Chapter.
The proposed townhomes are a unique type of residential
product that has not been constructed in the city for several
years. Although the City's established townhome standards
require guest parking in the amount of four parking spaces
per unit, a survey conducted by staff revealed that the nature
of this type of development requires less parking than is
addressed by the current code. Based on the results of the
parking survey, it is anticipated that the proposed request to
reduce the parking requirement of the project from 4 to 3.2
parking spaces per unit will not result in inadequate parking
capacity. The variance will allow the applicant the ability to
use the property in a manner that is consistent with the
current requirements for townhomes in surrounding cities.
2. That the granting of a variance is necessary for the preservation
and enjoyment of one or more substantial property rights.
The granting of the variance will preserve the applicant's
ability to develop an otherwise underutilized site which has
been vacant for several years. John Laing Homes would like
to proceed with a request for a decrease from 4 to 3.2
parking spaces which is consistent with other similar sized
projects that have been built without negative impacts.
3. That the granting of a variance will not be materially detrimental to
the public welfare or injurious to surrounding property.
The granting of the variance will not be materially detrimental
.to the public welfare or injurious to surrounding property as
the unit orientation and location of proposed townhomes
have been situated to avoid impacts to the homeowners to
the north and east of the site. Townhome parking will be
provided directly below each townhome, with guest parking
situated to the north of the site and screened from existing
residences with a seven-foot high decorative wall and
landscaping. Additionally, a mitigated negative declaration
was prepared which incorporated various mitigation
measures to ensure that any impacts are reduced to below
any level of significance.
Resolution No. 2005-114
Page 4 of 31
4. That the granting of a variance will not adversely affect the General
Plan of the City.
The granting of the variance will not adversely affect the
General Plan of the City since both the Two-Family
Residence (R2) zoning and proposed Medium-Density
Residential land use designation are consistent with the
proposed townhome proposal.
F. Santa Ana Municipal Code Section 41-277(a) limits the height of
townhomes to 27 feet and no more than two stories in height. The
applicant is requesting approval of Variance No. 2005-54 to allow a
maximum height of 35 feet and three stories in height for 30 units with the
remaining 14 units complying with the height limit. The City Council
determines that for Variance No. 2005-54, the following findings, which
must be established pursuant to Santa Ana Municipal Code Section 41-
638 in order to grant a variance from the provisions of the Santa Ana
Municipal Code, have been established:
1. That because of special circumstances applicable to the subject
property, including size, shape, topography, location or
surroundings, that the strict application of the zoning ordinance is
found to deprive the subject property of privileges not otherwise at
variance with the intent and purpose of the provisions of this
Chapter.
The current height requirement of 27 feet and two stories in
height would not allow for a townhome project with a
courtyard configuration to include tuck-under garages
accessed off an alley motor court. In order to provide the
additional amenity of enclosed parking garages immediately
available to each homeowner and ensure adequate amounts
of open space and landscaping, a maximum height of 35
feet and three stories in height is proposed. Additionally, the
proposed project features smaller-scale forms such as
recessed windows, projecting balconies and other significant
elements which visually reduce the height and scale of the
proposed buildings.
2. That the granting of a variance is necessary for the preservation
and enjoyment of one or more substantial property rights.
The granting of the variance will preserve the applicant's
ability to develop a townhome community featuring unit sizes
and amenities that suit the needs of prospective buyers. A
two-story product would limit the bedroom count and living
Resolution No. 2005-114
Page 5 of 31
areas which would potentially jeopardize the applicant's
ability to develop the subject site.
3. That the granting of a variance will not be materially detrimental to
the public welfare or injurious to surrounding property.
The granting of the variance will not be materially detrimental
to the public welfare or injurious to surrounding property as
the unit orientation and location of proposed town homes
have been situated to avoid impacts to the homeowners to
the north and east of the site. The individual units will
provide a minimum setback of 60 feet to the closest single
family residential units along the northerly property line in
order to ensure privacy and reduce any potential noise
impacts. The proposed three-story units utilize space well,
will conceal visible parking through enclosed garages at the
ground level and create a privacy buffer to the adjacent
residential uses.
4. That the granting of a variance will not adversely affect the General
Plan of the City.
The granting of the variance will not adversely affect the
General Plan of the City since both the Two-Family
Residence (R2) zoning and proposed Medium-Density
Residential land use designation are consistent with the
proposed townhome proposal. The variance will allow for
the ground floor space of the project to be utilized for
enclosed parking areas and will not add additional living area
which would not result in any impacts to the General Plan.
G. Santa Ana Municipal Code Section 41-280 requires townhome units to
provide a minimum 10-foot landscaped buffer between the buildings and
Edinger Avenue. The applicant is requesting Variance No. 2005-55 to
allow a seven-foot landscaped setback from the site perimeter wall for two
of the units. The City Council determines that for Variance No. 2005-55,
the following findings, which must be established pursuant to Santa Ana
Municipal Code Section 41-638 in order to grant a variance from the
provisions of the Santa Ana Municipal Code, have been established:
1. That because of special circumstances applicable to the subject
property, including size, shape, topography, location or
surroundings, that the strict application of the zoning ordinance is
found to deprive the subject property of privileges not otherwise at
variance with the intent and purpose of the provisions of this
Chapter.
Resolution No. 2005-114
Page 6 of 31
A minimum 10-foot landscaped buffer is required along
Edinger Avenue per Section 41-280 of the Santa Ana
Municipal Code. Due to the configuration of the units along
Edinger Avenue and an attempt at creating a varied street
presence, the applicant is requesting a three-foot relief from
the code on two of the units. The two units will have
entrances directly accessible from Edinger Avenue providing
architectural interest at the street level. Due to the layout
and configuration of the clustered town home concept, it
would be difficult to accommodate the 10 feet requirement at
this location.
2. That the granting of a variance is necessary for the preservation
and enjoyment of one or more substantial property rights.
The granting of the setback variance will preserve the
applicant's ability to develop the property as a well-designed
town home community that is consistent with the Two-Family
Residence (R2) zoning district. A project that has a direct
relationship to the street with a varied setback along Edinger
Avenue will provide visual interest to the project site.
Upgraded architectural materials and landscape palette will
be incorporated throughout the proposed John Laing Homes
development to compensate for the reduction in setbacks.
3. That the granting of a variance will not be materially detrimental to
the public welfare or injurious to surrounding property.
The granting of the setback variance will not be materially
detrimental to the public welfare or injurious to surrounding
property. Mitigated Negative Declaration No. 2004-198
identified any potential or adverse impacts will be mitigated
through mitigation measures identified in the document.
4. That the granting of a variance will not adversely affect the General
Plan of the City.
The proposed project will not adversely affect the General
Plan. The townhome concept is consistent with the
proposed General Plan Land Use Element designation of
Medium-Density Residential (MR-15). The proposal is
supported by the Land Use Element Goal: 2.0, Promote land
uses which enhance the City's economic and fiscal viability;
and Goal 3.0, to promote a balance of land uses to address
basic community needs.
Resolution No. 2005-114
Page 7 of 31
H. Santa Ana Municipal Code Section 41-286(a) requires a minimum of 40
percent of living area to be accessible from the ground level. The
applicant is requesting Variance No. 2005-56 for relief from this code
requirement. The City Council determines that for Variance No. 2005-56,
the following findings, which must be established pursuant to Santa Ana
Municipal Code Section 41-638 in order to grant a variance from the
provisions of the Santa Ana Municipal Code, have been established:
1. That because of special circumstances applicable to the subject
property, including size, shape, topography, location or
surroundings, that the strict application of the zoning ordinance is
found to deprive the subject property of privileges not otherwise at
variance with the intent and purpose of the provisions of this
Chapter.
A minimum of 40 percent of living area is required on the
ground level per the City's town home standards. Given that
the proposed townhome product includes two-car enclosed
garages for each homeowner, there is not enough floor
space within the site to provide 40 percent of floor space on
the ground level. Although a majority of units will contain a
living area on the ground level, ten of the units will be
accessed via a landing to the primary living areas on the
second and third floors. It is not anticipated that lack of 40
percent living area on the ground floor for each unit will
affect the aesthetic or functional quality of the project.
2. That the granting of a variance is necessary for the preservation
and enjoyment of one or more substantial property rights.
The granting of the variance for access will preserve the
applicant's ability to develop the property as a well-designed
townhome community that is consistent with the Two-Family
Residence (R2) zoning district. In order to satisfy the needs
of the prospective buyers and the City requirement for an
enclosed two-car garage per unit, the majority of the living
area for each town home will be on the second and third
floors. In order to ensure that the visual quality of the project
is preserved, all staircases for the proposed project are
enclosed within the individual units and each townhome will
be directly accessible and visible from the street.
3. That the granting of a variance will not be materially detrimental to
the public welfare or injurious to surrounding property.
The granting of the variance for access will not be materially
detrimental to the public welfare or injurious to surrounding
Resolution No. 2005-114
Page 8 of 31
property. Mitigated Negative Declaration No. 2004-198
identified any potential or adverse impacts will be mitigated
through mitigation measures identified in the document.
4. That the granting of a variance will not adversely affect the General
Plan of the City.
The proposed project will not adversely affect the General
Plan. The townhome concept is consistent with the
proposed General Plan Land Use Element designation of
Medium-Density Residential (MR-15). The proposal is
supported by the Land Use Element Goal: 2.0, Promote land
uses which enhance the City's economic and fiscal viability;
and Goal 3.0, to promote a balance of land uses to address
basic community needs.
Section 2. The City Council has reviewed and considered the information
contained in the initial study and the mitigated negative declaration and mitigation
monitoring program prepared with respect to this Project. The City Council has, as a
result of its consideration and the evidence presented at the hearings on this matter,
determined that, as required pursuant to the California Environmental Quality Act
("CEQA") and the State CEQA Guidelines, a mitigation negative declaration and
mitigation monitoring program adequately addresses the expected environmental
impacts of this Project. On the basis of this review, the City Council finds that there is
no evidence from which it can be fairly argued that the Project will have a significant
adverse effect on the environment. The City Council hereby certifies and approves the
mitigated negative declaration and mitigation monitoring program and directs that the
Notice of Determination be prepared and filed with the County Clerk of the County of
Orange in the manner required by law.
Pursuant to Title XIV, California Code of Regulations ("CCR") 9 735.5(c)(1), the City
Council has determined that, after considering the record as a whole, there is no evidence
that the proposed project will have the potential for any adverse effect on wildlife resources
or the ecological habitat upon which wildlife resources depend. The proposed project
exists in an urban environment characterized by paved concrete, roadways, surrounding
buildings and human activity. Therefore, pursuant to Fish and Game Code 9 711.2 and
Title XIV, CCR 9 735.5(a)(3), the payment of Fish and Game Department filing fees is not
required in conjunction with this project.
Section 3. The City Council after conducting the public hearing hereby approves:
A. Tentative Tract Map No. 2005-07 as conditioned in Exhibit "A" attached
hereto and incorporated herein.
B. Variance No. 2005-53 from number of required parking spaces as
conditioned in Exhibit liB" attached hereto and incorporated herein.
C. Variance No. 2005-54 from maximum allowable height as conditioned in
Exhibit "C" attached hereto and incorporated herein.
Resolution No. 2005-114
Page 9 of 31
D. Variance No. 2005-55 from required front landscaped setback as
conditioned in Exhibit "D" attached hereto and incorporated herein.
E. Variance No. 2005-56 from floor plan configuration as conditioned in
Exhibit "E" attached hereto and incorporated herein.
These decisions are based upon the evidence submitted at the abovesaid hearing,
which includes but is not limited to: the Request for Council Action dated December 5,
2005 and exhibits attached thereto; and the public testimony written and oral, all of
which are incorporated herein by this reference.
Section 4. This decision rendered by the City Council of the City of Santa Ana
is final and is subject to judicial review pursuant to California Code of Civil Procedure
section 1094.6. The Clerk of the Council shall give direct notice to the applicant of the
Council's decision and these findings.
ADOPTED this 5th day of December, 2005
APPROVED AS TO FORM:
Joseph W. Fletcher, City Attorney
t !'.-/'~._--
By: "-"1 h I'j l.,
Kylee O. Otto
Assistant City Attorney
YES:
Councilmembers: Alvarez. Bist. Bustamante, Pulido Garcia, Solorio (6)
NOES:
Councilmembers: None (0)
ABSTAIN:
Council members: None (0)
NOT PRESENT: Councilmembers: Christy (1)
Resolution No. 2005-114
Page 10 of 31
CERTIFICATE OF ATTESTATION AND ORIGINALITY
I, PATRICIA E. HEALY, Clerk of the Council, do hereby attest to and certify the
attached Resolution No. 2005-114 to be the original resolution adopted by the City
Council of the City of Santa Ana on December 5.2005.
Date: /2 /1 '5'" /~ ;--
/ /
Clerk of the Council
City of Santa Ana
Resolution No. 2005-114
Page 11 of 31
EXHIBIT A
Conditions for Approval for Tentative Tract Map No. 2005-07
Tentative Tract Map No. 2005-07 is approved subject to compliance to the reasonable
satisfaction of the Planning Manager, with all applicable sections of the Santa Ana
Municipal Code, the California Administrative Code, the Uniform Fire Code, the Uniform
Building Code, and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this subdivision.
The applicant must remain in compliance with all conditions listed below throughout the life
of the subdivision.
A. Planning Division
1. Comply with all conditions and requirements from the Development
Review Committee (DRC) for the development project (DP 04-73).
2. The Covenants, Conditions and Restrictions (CC&Rs) must be approved
by the Planning Division prior to the issuance of any building permit. Such
CC&Rs must contain at a minimum, the following:
a. Project Maintenance.
b. Standards shall be established for the exterior maintenance of each
unit within the community.
c. Graffiti removal will be required within 48 hours.
d. Assignment of repair of perimeter walls will be specified in the
CC&Rs in the event of damage.
e. CC&Rs are to be in effect in perpetuity.
f. Any proposed modifications to the CC&Rs will require approval by
the City of Santa Ana.
g. The use of professional management to ensure a quality operation
and maintenance.
h. Parking limitations including no parking in driveways.
3. A final map must be approved and recorded prior to issuance of building
permits.
4. The final map and all improvements required to be made or installed by
the subdivider must be in accordance with the design standards and
specifications of the Santa Ana Municipal Code and the requirements of
the State Subdivision Map Act.
Resolution No. 2005-114
Page 12 of 31
5. Two copies of the recorded final map and CC&Rs shall be submitted each
to the Planning Division, Fire Department, Building Division and Public
Works Agency within 10 days of recordation.
6. Prior to the issuance of building permits, the interior building amenities shall
be submitted for review by the Planning Division. The amenity package
submitted for review shall include but not be limited to flooring, staircase
railings, doors and hardware, kitchen appliances and cabinetry, dual bowl
sinks and fixtures, tile walls, tiled shower enclosures and kitchen
countertops of stone tile or stone slab, or their equivalent. At minimum
they will include a product line for the high grade appliances, all cabinets
be made of a stain grade, the use of smooth wall and ceiling interior
drywall finish and washers and dryers in each residential unit.
7. Provide for lighting and landscape maintenance. The lighting plan and
design will be reviewed by the Planning Division during the lighting plan
check phase.
8. Development, operational and maintenance standards shall be
established for the number, style and location of benches. These benches
shall be reviewed and approved when the landscapes are submitted into
plancheck.
9. Common area amenities shall comply with the following:
a. Pursuant to the Plan (Attachment 1 and 2), plazas, drive aisles,
pedestrian walkways and common area amenities for the project
shall be completely installed prior to the issuance of a certificate of
occupancy for the project phase that includes the open space.
10. Pedestrian walkways shall be provided throughout the project site as
shown on the Plan (Attachment 1 and 2). The amenities to be provided
along this pathway shall include decorative concrete, accent lighting,
landscape planters with vertical landscape as shown on the Landscape
Plan. These improvements in each phase must be completed prior to
occupancy of the first unit in the respective phases.
11. A minimum seven-foot high wall shall be constructed around the perimeter
of the site and consist of a decorative block such as splitface or
slumpstone, with contrasting pilasters and decorative trim caps. Prior to
the issuance of building permits, a wall and fencing plan shall be
submitted for review and approval by the Planning Division.
12. Benches and pedestrian seating shall be made of a durable material such
as concrete or painted iron and be designed to minimize effects from
vandalism, skateboarding and weather. Prior to the issuance of building
Resolution No. 2005-114
Page 13 of 31
permits, a site furniture plan shall be submitted to the Planning Division for
review and approval.
13. Trash receptacles should be located in high-activity areas, such as plazas
and other public open spaces. The style shall be compatible with other
plaza furnishings.
14. All street furniture surfaces, pedestrian-level walls and amenities shall
incorporate graffiti resistant coatings.
15. The courtyards shall include amenities such as informal modern outdoor
furniture and seating areas, decorative pavers, landscape trees and plant
material.
16. Prior to the issuance of building permits, the exterior building amenities,
materials and finishes shall be submitted for review and approval by the
Planning Division. All exterior plaster surfaces shall have a smooth-
troweled finish.
17. Prior to the issuance of building permits, the applicant shall submit for
review and approval by the Planning Division a window schedule detailing
the project windows. Acceptable windows for the project are wooden or
metal-clad wooden materials with substantial use of detail.
18. The courtyards and all paving shall be completely installed prior to the
issuance of any certificate of occupancy.
19. An open space area measuring a minimum of 5,400 square feet in area
shall be located at the rear of the project entry adjacent to the northerly
property line. The open space shall include informal modern outdoor
furniture, seating areas, playground equipment and landscape trees and
material to be reviewed and approved by the Planning Division prior to
Building Permit issuance.
20. All garages shall contain double wall insulated garage doors with an
automatic opener and transmitter.
21. All units along the northerly property line shall be limited to 27 feet, or two
stories in height.
22. Light shields shall be installed for all light standards adjacent to residential
uses to avoid light intrusion and comply with Chapter 41-1304(c) and
Chapter 8-211 (m)(4) of the Santa Ana Municipal Code.
23. All third story windows facing the northerly property line shall utilize
obscure glass to ensure privacy to the surrounding neighbors.
Resolution No. 2005-114
Page 14 of 31
Mitigation Measures
24. The project shall comply with the attached Mitigation Monitoring Plan
(Attachment 3)
Resolution No. 2005-114
Page 15 of 31
.. j
~ :
-t! U 'f'}
~jjJ~'>tijl ~ ,1JJ&j}ju
~~!!~!~~~~~~~~~~~~!~!!!!!
'MJHJOISD !)NIJSID
l:l
@
i
,\
i
1:!~!!~:!!!!!5!!!~~
: I j I ~ \ d I '
~'.~~ ~<t.<l'i";
l:~~t, 1 ,-.!. q.,l
1"'~ a' J-. ~ \1
j~u.JJdi.dJfHht
.
t. I I.,,; ~
!II 1 -"j~:
U q >. ~jil 1
"g i ~ ; : p D }j P f d 11 q
!4 ii.HHnHdiJ!di~
! 1
i ~ :~ ~ >
~ J j J 1 J 1
'" , ~ ~ ~ ~ .. " ~
}
.~ ~ ~ :~
, ,I . J ,I
J , ~ (
. )
l , , ! .
j . ~ J
1 ,
. . ,~ J j j
~ ! ! . .
I J I t f
I .. : t t ~ j
, .
j j { ~ , !
:;t , l i .'
i ,I
I . ~ .
; J ~ 1
A , ~ I i
~qq
~ ;~J}
~ t.~j~
_! ;. III
, J . ~
I! .
i ~
1
j.
~
Resolution No. 20()'WJ!fIIIIrWO~ !)HIJ.$D(J
Page 16 of 31
A'ITACHMENT 1
Cite ........0...
'II'
i !
: !
...<!:-
'E
o.
':Z,l
~il
~!~
a;'~ ~ I
~t J jf
a
;11'
] i
~
~
,;
E
:.\.::. :~ ;
I ~ I ,
U'l
I,l.
i
I j t
. I .
. h J
t
I
.
~1
c"'f
"i :!
'ie 'tlil
~ ..
III
Z
.l~
eoo
Q..
ATIACHKENT 2
i
"
.~
'i!
;...
r..:
In
H ;~I
a:1 s;~
:;;1< :d
~ ".
() ~~
>J ia~
C)~ .
H ;.i
:.::~m
o
.:f1J
~.tiI J
!
I::
o
...
...
U
~
Ul
~
-
III
......
~
./::
o
~
.;
-
-,
m
Q,)
S
o
....d
~
~
E-8
~
Q,)
"OD
~
.-
~
J:.I..l
Resolution No. 2005-114
Page 17 of 31
EDINGER TOWN HOMES
MITIGATION MONITORING PROGRAM ER 2004-198
Mitigation Measure
The developer shall
use zero Volatile
Organic Compounds
(VOCl content
architectural
coatings during the
construction of the
project to the
maximum extent
feasible. Building
plans shall identify
the architectural
coatings proposed
for the project.
Prior to
commencement of
construction
activities, the
project developer
shall identify to
the City a
construction
relation officer to
act as a community
liaison concerning
onsite construction
activity impacts.
The name and phone
number of the
construction
relation officer
shall be posted on
the project site
To ensure compliance
with SCAQMD Fugitive
Dus t Rul.e 403,
grading plans and
demolition plans for
the proposed project
shall reflect the
following notes:
All material
excavated or graded
will be sufficiently
watered to prevent
Resolution No. 2005-114
Page 18 of 31
Timing
Prior to
Building
Permi ts
Prior to
Const:ruction
Prior to
Grading
Permits
ATIACBMKNT 3
1 of 10
Agency
Planning/
Building
Agency
Approval
Planning/
Building
Agency
excessive amounts of
dust. Watering with
complete coverage
shall occur at least
t'Wice daily, once in
the late morning and
once after work is
done for the day.
All clearing and
earthwork activities
shall cease during
period of high winds
(winds greater than
25 mph averaged over
one hour) or during
Stage 1 or Stage 2
smog episodes.
Streets surrounding
the project site
should be cleaned at
the end of each day
of construction.
All material
transported offsite
shall either be
sufficiently wa~ered
or securely covered
to prevent excessive
amounts of dust.
The amount of area
disturbed by
clearing and
earthwork activities
shall be minimized
at all times.
Equipment engines
shall be maintained
in good condition
and in proper tune
according to
manufacturer's
specifications.
To the extent
feasible, gasoline
powered equipment
Resolution No. 2005-114
Page 19 of 31
2 of 10
shal] be used for
onsite and offsite
construction
act:i.vi ties.
Prior to the
issuance of grading
permits. the
applicant shall
prepare a site-
specific
geotechnical study
that addresses the
seismic and
liquefaction
constraints and soil
conditions on the
project site, the
building load
requirements and
identifies design
recommendations to
ensu~e the
geotechnical
stability of the
project.
Prior to issuance of
grading permits, the
applicant shall
submit for review
and approval a
surface
drainage/grading/ero
sion control plan
prepared by a
registered civil
Engineer, showing
the direction and
means of flow to the
adjacent street. The
plan lS to include
existing and
proposed elevations
at and adjacent to
all property lines.
Drainage routed to
the street shall be
I directed beneath ~he
I sidewalk and through
I the curb.
Resolution No. 2005-114
Page 20 of 31
Prior to
Grading
Permits
Prior to
Grading
Permits
3 of 10
Planning/
Building
Agency
Public Works
Agency
Prior to the
issuance of grading
permits, the project
developer shall show
proof of coverage
under NPDES General
Construction
Activity Storm Water
Permit that
includes:
A copy of the
project's permit
issued by the State
I Water resource
Control Board that
identifies the
project's permit
number (WDID).
Two copies of the
Storm Water
Pollution Prevention
Plan.
Prior to the
issuance of grading
permits, the
applicant shall
prepare a Phase II
Environmental Site
Assessment to
determine if there
is any residual
agriculture
chemicals in the
soil. In the event
agriculture
chemicals are
present remediation
of the soils shall
occur prior to the
commencement of
grading operations.
Prior to the
issuance of grading
permits, the
applicant shall
Prior to
Grading
Permits
Prior to
Grading
Permi ts
Prior to
Grading
Permi ts
4 of 10
Public Works
Agency
Planning I
Building
Agency
Planningl
Building
Agency
Resolution No. 2005-114
Page 21 of 31
coordinate with the
utility company to
determine the
presence of PCBs in
the transforms along
the project site. In
the event PCBs are
present the
applicant shall
coordinate with the
utility company on
the removal of the
transformers.
Prior to the
issuance of grading
permits, the
applicant shall
submit and have
approved a surface
drainage/utility
plan that depicts
all applicable Site
Design Structural
Source Control and
Treatment Control
Best Management
Practices in
accordance with the
Orange COUIlty
Drainage Area
Management Plan and
the City of Santa
Ana local
Implementation Plan.
Prove two copies of
the Water Quality
Management Plan that
include the
following:
Site Assessment
Site design BMPs
Applicable Routine
Source Control BMps
Electing and sizing
the Treatment
Control Blvl:Ps
Resolution No. 2005-114
Page 22 of 31
Prior to
Grading
Permits
Prior to
Grading
Permits
5 of 10
Public Works
Agency
Public Works
Agency
Mechanisms by which
funding for long-
term
operation and
maintenance of all
structural BMPs
shaJ.l be provided
Operation and
Maintenance Plan to
describe the long-
term operation and
maintenance
requirements of all
applicable
structural BMPs and
to identify the
entity in charge of
implementation
Prior to issuance of
grading permits the
project applicant
shall receive
approval of NPDES
Permit for the State
regional Water
Quality Control
Board for proposed
onsite dewatering
operations.
The proposed project
would be subject to
City of Santa Ana
Federal Clean Water
Protection
Enterprise Fees
Prior to issuance of
grading permits the
applicant shall
identify if
dewatering
operations are
necessary for the
construction of the
project.
Prior to
Grading
Permits
Prior to
Grading Permit
Prior to
Grading
Permits
In the
dewatering
operations
event Prior to
Grading
are Permi ts
6 of 1 0
Public Works
Agency
Public Works
Agency
Planningl
Building
Agency
Public Works
Agency
I
I
.
Resolution No. 2005-114
Page 23 of 31
required, prior to
the issuance or
grading permi ts . the
applicant shall
provide proof to the
City of an NPDES
permit from the
Regional Water
Quality Control
Board for ons i te
dewatering
operations.
Prior to issuance of
a grading permit.
the project
applicant shall
submit a final
surface water runoff
evaluation for
rev~ew and approval
showing existing and
proposed facilities
and methods of
draining the site
without exceeding
the capacity of any
street or adjacent
storm drain
fadli ty.
Building Plans shall
reflect that Sound-
Rated windows with a
Sound Transmission
Class (STC) of 30 or
greater shall be
installed on all
windows for the
southern building
fa<;:ade fronting
Edinger Avenue.
Building Plans shall
reflect that Sound-
Rated windows with a
Souno transmission
Class (STCl of 28 or
greater shall be
installed on all
windows for the
Resolution No. 2005-114
Page 24 of 31
Prior to
Grading Permit
Prior to
Building
Permits
Prior to
Building
Permits
7 of 10
Public Works
Agency
Planning/
Building
Agency
Planning/
Building
Agency
eastern building
fac;ade racing
Pairview Street.
Building Plans shall
reflect that Sound-
Rated doors with a
Sound
Transmission Class
(STC) of 30 or
greater shall be
installed on all
doors for the
southern building
fac;ade fronting
Edinger Avenue.
Building Plans shall
reflect that
building facades
facing Edinger
Avenue and Fairview
Street are provided
with mechanical
ventilation with a
minimum of two fresh
air exchanges so
that residential
units can operate
with a closed window
condition.
Building Plans shall
reflect that
building facades
facing Edinger
Avenue and Fairview
Street are provided
with roofing systems
that have a minimum
of ~-inch plywood
sheathing and
minimum insulation
of R-19 for all
i attic spaces.
;
i 1>.11 Attic vents
I, shall be oriented
away from Edinger
i Avenue and Fairview
Prior to
Building
Permits
Prior to
Building
Permits
Prior to
Building
Permits
Prior to
Building
Permits
B of 10
Planning/
Building
Agency
Planning/
Building
Agency
Planning/
Building
Agency
Planning/
Building
Agency
Resolution No. 2005-114
Page 25 of 31
Street
Grading Plans and
Building Plans for
the proposed project
shall note
"Construction
activities on the
project site shall
only take place
between ~he hours of
7:00 a.m. to 8:00
p.m. Monday through
Saturday and no
construction
activity shall take
place on Sundays or
federal holidays".
Grading Plans and
Building Plans for
the proposed project
shall note "No
construction
equipment on the
project site shall
operate including
warming up until
after 7: 00 a.m"_
Grading plans and
Building Plans for
the proposed project
shall note "All
construction
equipment shall be
properly maintained
and tuned to
minimize noise
emissions and all
equipment shall be
fitted with properly
operating mufflers
and air intake
silencers" .
Grading Plans and
Building Plans for
the proposed project
shall note
"Stockpiling and
vehicle staging
Resolution No. 2005-114
Page 26 of 31
Prior to
Grading Permit
and Building
Permit
Prior to
Grading Permit
and Building
Permit
Prior to
Grading Permit
and Building
Permit
Prior to
Grading Permit
and Building
Permit
9 of 10
Planning/
Building
Agency
Planning/
Building
Agency
Planning/
Building
Agency
Planning/
Building
Agency
areas shall be
located away from
existing residential
uses" .
Resolution No. 2005-114
Page 27 of 31
1 0 of 1 0
EXHIBIT B
Conditions for Approval for Variance No. 2005-53
Variance No. 2005-53 (parking) is approved subject to compliance, to the reasonable
satisfaction of the Planning Manager, with all applicable sections of the Santa Ana
Municipal Code, the California Administrative Code, the Uniform Fire Code, the Uniform
Building Code and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this variance.
The applicant must remain in compliance with all conditions listed below throughout the
life of the variance. Failure to comply with each and every condition may result in the
revocation of the variance.
A. Plannina Division
1. The project shall remain in compliance with Site Plan Review DP No. 04-
73.
2. The project shall provide a minimum of 142 parking spaces including 88
enclosed garage spaces and 54 guest parking spaces. The minimum
parking stall size is 8-1/2 feet wide by 18 feet in length. All stalls shall be
double striped and shall not encroach into required landscaped areas.
Resolution No. 2005-114
Page 28 of 31
EXHIBIT C
Conditions for Approval for Variance No. 2005-54
Variance No. 2005-54 (height) is approved subject to compliance, to the reasonable
satisfaction of the Planning Manager, with all applicable sections of the Santa Ana
Municipal Code, the California Administrative Code, the Uniform Fire Code, the Uniform
Building Code and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this variance.
The applicant must remain in compliance with all conditions listed below throughout the
life of the variance. Failure to comply with each and every condition may result in the
revocation of the variance.
A. Plannina Division
1. The project shall remain in compliance with Site Plan Review DP No. 04-
73.
2. The project shall not exceed 35 feet or three stories in height, as
measured from the lowest grade of the structure to the top of the structure.
3. All townhome units facing or immediately adjacent to the northerly
property line at the rear of the project site shall not exceed two stories in
height.
4. Accessory structures shall not exceed 15 feet or one story in height.
Resolution No. 2005-114
Page 29 of 31
EXHIBIT D
Conditions for Approval for Variance No. 2005-55
Variance No. 2005-55 (setbacks) is approved subject to compliance, to the reasonable
satisfaction of the Planning Manager, with all applicable sections of the Santa Ana
Municipal Code, the California Administrative Code, the Uniform Fire Code, the Uniform
Building Code and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this variance.
The applicant must remain in compliance with all conditions listed below throughout the
life of the variance. Failure to comply with each and every condition may result in the
revocation of the variance.
A. Plannina Division
1. The project shall remain in compliance with Site Plan Review DP No. 04-
73.
2. The three-foot reduction in required landscape setback shall not exceed 30
linear feet, as measured from the front property line along Edinger Avenue.
Resolution No. 2005-114
Page 30 of 31
EXHIBIT E
Conditions for Approval for Variance No. 2005-56
Variance No. 2005-56 (floor plan configuration) is approved subject to compliance, to the
reasonable satisfaction of the Planning Manager, with all applicable sections of the Santa
Ana Municipal Code, the California Administrative Code, the Uniform Fire Code, the
Uniform Building Code and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this variance.
The applicant must remain in compliance with all conditions listed below throughout the
life of the variance. Failure to comply with each and every condition may result in the
revocation of the variance.
A. Plannina Division
1. The project shall remain in compliance with Site Plan Review DP No. 04-
73.
Resolution No. 2005-114
Page 31 of 31