Loading...
HomeMy WebLinkAboutItem 22 - Ordinance Establishing Approval of Changes Affecting the City’s Drinking Water Quality Standards & Regulations Public Works Agency www.santa-ana.gov/pw Item # 22 City of Santa Ana 20 Civic Center Plaza, Santa Ana, CA 92701 Staff Report October 20, 2026 TOPIC: Ordinance Establishing City Council Approval of Changes Affecting Drinking Water Quality Standards and Regulations AGENDA TITLE Adopt an Ordinance Establishing City Council Approval of Changes Affecting the City's Drinking Water Quality Standards and Regulations (Continued from the Regular City Council meeting of October 6, 2026) RECOMMENDED ACTION Adopt an Ordinance Establishing City Council Approval of Changes Affecting the City's Drinking Water Quality Standards and Regulations. ORDINANCE NO. NS-XXXX entitled AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA ANA, CALIFORNIA, ADDING SECTION 39-43 TO ARTICLE II OF CHAPTER 39 OF THE SANTA ANA MUNICIPAL CODE TO ESTABLISH CITY COUNCIL APPROVAL OF CHANGES AFFECTING DRINKING WATER QUALITY STANDARDS AND REGULATIONS [includes determination that ordinance adoption is not subject to California Environmental Quality Act (CEQA) requirements pursuant to CEQA Guidelines Sections 15060(c)(2), 15060(c)(3), 15061(b)(3), 15378, and 15378(b)(5)] GOVERNMENT CODE §84308 APPLIES: No DISCUSSION On May 18, 2026, the U.S. Environmental Protection Agency (EPA) announced a proposal to revise federal drinking water Maximum Contaminant Levels (MCLs) for two per- and polyfluoroalkyl (PFAS) compounds: perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS), and a proposal to rescind drinking water standards for four additional PFAS compounds: perfluorohexane sulfonic acid (PFHxS), hexafluoropropylene oxide dimer acid (HFPO-DA), perfluorononanoic acid (PFNA) and perfluorobutane sulfonic acid (PFBS), as well as Hazard Index mixtures of these PFAS chains. It is important to note that these proposed rules are still being considered by the EPA and have not yet gone into effect. However, the recent proposals from the EPA have City Council 22 — 1 10/20/2026 Ordinance Establishing City Council Approval of Changes Affecting Drinking Water Quality Standards and Regulations October 20, 2026 Page 2 demonstrated that government requirements and standards for drinking water can change to either strengthen or relax water quality standards. On June 16, 2026, in response to the proposed EPA rule revisions, the City Council directed staff to prepare an ordinance that would codify the requirement for staff to bring any proposed change in drinking water standards to the City Council for review and approval before local implementation. The City's drinking water system is classified as a public water system and exists under a permit from the State of California, as amended on July 30, 2026 (Exhibit 1). As such, the City is required to comply with all federal standards and the requirements set forth in the California Safe Drinking Water Act, Health and Safety Code and any regulations, standards, or orders adopted thereunder. The City adheres to the set of standards in effect as of today and will continue do so as they maintain a higher standard than the proposed EPA rule revisions. In response to Council direction, staff has prepared a proposed ordinance (Exhibit 2) that would require City Council review and approval of any change to drinking water standards and regulations while preserving the City's ability to comply promptly with federal and state law, public water system permit conditions, binding regulatory orders, and emergencies affecting public health or water service. The proposed ordinance will allow for transparency and the continued protection of our City's drinking water in spite of changes to federal and state regulations that may diminish water quality standards. The proposed ordinance also recognizes that the City, under its public water supplier permit, may be required to enact mandatory water quality standards and treatment measures. In which case, the proposed ordinance provides a compliance process for such future requirements to be presented to the City Council for consideration. Adoption of the ordinance would strengthen transparency and accountability, support informed long-term decision-making, and reinforce public confidence in the City's continued commitment to providing safe, reliable, and high-quality drinking water. ENVIRONMENTAL IMPACT The City Council finds and determines, in accordance with the California Environmental Quality Act (CEQA) and the CEQA Guidelines, that the introduction and adoption of this ordinance is not subject to CEQA because the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment (Title 14 California Code of Regulations (CCR) § 15060(c)(2) and the activity is not a project as defined in Section 15378 of the CEQA Guidelines because the ordinance is an organization administrative activity which establishes a process for City Council review and approval of discretionary and mandatory changes to City drinking water standards and regulations and does not itself authorize or require any physical alteration, construction, expansion, or other physical change to the City's public water system or the City Council 22 — 2 10/20/2026 Ordinance Establishing City Council Approval of Changes Affecting Drinking Water Quality Standards and Regulations October 20, 2026 Page 3 environment. (14 CCR §§ 15060(c)(3) and 15378(b)(5).) Additionally, the ordinance is exempt from CEQA because it can be seen with certainty that there is no possibility that the adoption of this ordinance may have a significant effect on the environment. (14 CCR § 15061(b)(3).) FISCAL IMPACT There is no fiscal impact associated with this action. EXHIBIT(S) 1. Public Water System Permit 2. Ordinance Submitted By: Rodolfo Rosas, P.E., Acting Executive Director of Public Works Agency Approved By: Alvaro Nunez, City Manager City Council 22 — 3 10/20/2026 Exhibit 1 GAvtiv NEWMOM uortnxx c a 1...... 0 YSECRETARY FOR Y'+�r�Y�Y7i Y000A OAFCIA Water CfF1'ROM IFCfITAL I`£ITE{:81ilM1l State Water Resources Control, Board D vis,en of Drinking Water Sent via email: CBARRERA ANTA-ANA-0RG July 30, 2026 Mr_ Cesar Barrera Deputy Public Works DirectorJWater Resources Manager City of Santa Ana 220 S. Daisy Avenue, M-65 P_0_ Box 1988 Santa Ana, CA 92703 Gear Mr. Barrera: SYSTEM N0. 30100 38—P E RM I T A M E ND M E NT NO. 05-08-2 PA-006 FOR CHANGE OF STATUS FOR ACTIVE WELL 32 AND ASSOCIATED NITRATE BELNDING FACILITY TO STANDBY In a permit amendment application to the Division of Drinking Water (Division) on July 24. 2026, the City of Santa Ana (City) requested a change of status for Well 32 and associated nitrate blending facility from active to standby. Well 32 has been changed status from inactive to active on September 30, 2025, after building a transmission line from well site to Garthe Reservoir Nitrate Blending Facility. Water from Well 32 is not served to the distribution system since due to pending approval of the Garthe NitrateIPFAS Blending and Monitoring Plan (Plan). The Plan was approved on July 6, 2026. However, the City decided to change the status from active to standby because PFOA and PFHxS are all above the response levels when well samples were collected during pump to waste operation. As a result of the changes, Domestic Water Supply Permit No_ 05-08-10P-001 issued to the City on May 26, 2010, is hereby amended to change the status of Well 32 from active to standby subjectto the following conditions: 1 . The sources approved 4or domestic use are listed in Tables 1 , 2 and 3, as follows: Table 1 — Ground Water Sources Source Capacity (gpm) Status PS Code Well 20 3,000 Active 30100 8_021_021 E. ,J4AMIN ESQuIVEL' CHAIR I ERIc OPPENHEIMEF[i EXECUTIVE DIfRECTGR 2 MACARTHIUR PL., STE 160, SnntoL Ana,CA 9.2707 1 "Ww WaLlaFeQyrd5.GM.0*V City Council 22 — 4 10/20/2026 - 2- July 30, 2026 Source Capacitor (9PM) Status PS Cade WeI121 3,000 Active 3010038_022_022 ''Nell26. 2,100 Active 3010038_026_026 Well2? 3,050 Standby 3010038027027 Well28 2-760 Standby 3010038_028_028 Well 29 2,750 Active 30100 8_029_029 Well30 3,000 Active 3010038_030_030 Well31 2,700 Standby 3010038031031 Well32 2,500 Standby 3010038_032_032 Well 33 2,800 Active 30100 8_033_03 Well 34 1 ,600 Active 3010038_034_034 Well 35 3,000 Active 30100 8_037_037 Well 36 3,600 Active 3010038_035_035 Well 37 3,000 Active 3010038_038_038 Well 38 2,500 Active 30100 8_039_039 Well39 3,000 Active 3010038_061_061 Well40 2,500 Active 3010038_073_073 Well41 3,000 Standby 3010038_074_074 Table 2 — Surface Water Sources Source Capacity (Cfs) Status PS Cade SA-1 6.5 Active 3010038 066 066 `"' 2 9.7 Active 3010038 067 067 SA-3 6.5 Active 3010038 068 068 A-4 6.5 Active 3010038 069 069 A-5 12.9 Active 3010038 070 070 SA-6 12.0 Active 3010038 071 071 SA-7 16.2 Active 3010038 072 072 City Council 22 — 5 10/20/2026 Mr =esar gar,era - t - July 30, 2026 Table 3 — Interconnections with Neighboring Water Systems Water System Capacity Status PS Code Nate Mesa Water 1 500 Emergency 3010038 8 88 Inflow; Smalley District P — — Rc Sunflower Mesa Water 1,5DO Emergency 3010038_89_89� Inflow; Bear Di stri ct Str' u n fl o er Mesa Water 3,600 Emergency _ Outflow; Harbor Distri ct Blvd/Sunflower City of Fountain 1600 Emergency30100389191 Inflow, Edinger Valley ; _ _ Ave/Driftwood D, City of Tustin 900 Emergency 3010038_93_93 Inflow; McFade-i Village Way Ci-.y of Carden Outflow; Ora°ve 9sJ0 Emergency - Fairview/Huckleberry . The approved domestic water treatment facilities are listed in Table 4, as follower Table 4 Treatment Facilities Treatment Facilities Status PS Cole Treatment Processes Gamthe Reservoir N Vate Wells 10 and 24 blending with Blending Standby 3010038_040_040 Wells 36 and 39 at Carthe Reservoir Chlorination of groundwater OSHG at West Reservoir Active 3010038045045 with sodium hypochlorite for Wells 201, 21 . and 30 OSHG at Well 26 Active 3010038 048 048 Chlorination of groundwater with sodium hypochlorite OSHG at Well '27 Standby 30100 8_049_049 Chlorination of groundwater with sodium hypochlorite OSHG at Well 28 Standby 3010036_0 0_050 Chlorination of groundwater with sodium hypochlorite OSHG at Well 31 Standby 3010038053053 Chlorination of groundwater with sodium hypochlorite O HG at Well 32 Standby 3010038_054_054 Chlorination of groundwater with sodium hypochlorite City Council 22 — 6 10/20/2026 Mr_ Cesar Barrera - 4- July 30, 2026 Treatment Facilities Status PS Code Treatment Processes OSHG at Well 34 Active 3010038 056 056 Chlorination of groundwater with sodium hypochlorite OSHG at Well 35 Active 3010038058058 Chlorination of groundwater with sodium hypechlorite Chlorination of groundwater OSHG at Well 36 Active 30100 6_057_057 with sodium hypochlorite for Wells 18 and 36 OSHG atWell 37 Active 3010038042042 Chlorination of groundwater with sodium hypochlorite Chlorination of groundwater OSHG atlell 39 Active 3010038_062_062 with sodium hypochlorite for Wells 24 and 3 OSHG at Well 41 Standby 3010038-076_076 Chlorination of groundwater with sodium hypochlorite Chlorination of groundwater OSHG at Walnut Reservoir Active 3010038087087 with sodium hypochlorite for Wells 29 and 33 Reservoir Management System (RMS) with chlorination or chloramination injection system RIv1S with Chlorination or Active - is installed at the followingChloramination reservoirs: Crooke Reservoir, East Reservoir. and South Reservoir Well 40 PFAS Treatment Plant Active 3010038 095 09�, 1 on exchange treat ent of (Plant) — — PFAS from Well 40 Well 38 PFAS I X Treatment Active 3010038 101 1�. 5 1 or e,: change treatment of Plant — PFAS from Well 38 OSHG,. On-site Sodium Hypochlorite Generation System The Primal Station (PS) Codes associated with the PFAS Treatment Plants are provided in Table 5 below: Table 6 — PFAS Treatment Plant Sample Pointe Treatment Facility Sample Point Name PS Code Well 40 PFAS I; ��,lell 4s� ' ]10038 073 �v� Treatment Plant — — City Council 22 — 7 10/20/2026 f-Jr Cesar - F, - July 30, 2026 Treatment Facility Sample Point Name PS Cade WELL 40 DFAS IX TP 1 1 V1 (V110) 3010038 095 095 EFFLUENT —WELL 40 PFAS IX TP T1 V2 (V120) 3010038 095 096 EFFLUENT —WELL 40 PFAS IX TP T2 V1 (V130) 3010038 095 097 EFFLUENT —WELL 40 PFAS IX TP T2 V2 (V140) 3010038 095 098 EFFLUENT —COMBINED IX EFFLUENT 3010038_095_099 Well 38 301OD38_039_039 WELL 38 PFAS IX TP T1 V1 (V110) 3010038 101 101 EFFLUENT WELL 38 PFAS IX TP T1 V2 (V120) 3010038 101' 102 Well 38 PFASIX EFFLUENT — — Treatment Plant WELL 38 PFAS IX TP T2 V1: (V130) EFFLUENT 3010038_101_103 WELL 38 PFAS IX TP T2 V2 (V140) 3010038 101 104 EFFLUENT — — COMBINED IX EFFLUENT 3010038 101 105 3. No changes, additions; or modifications can be made to the sources or treatment facilities listed in Conditions 1 and 2 unless an amended water permit has first been obtained from the Division. 4. The standby wells must be used only for short-term emergencies of five consecutive days or less; and for less than a total of fifteen calendar days a year. 5. The City must monitor the standby wells a minimum of once every compliance cycle for all inorganic; organic, and radiological contaminants with an I ICL unless a waiver has been granted by the Division pursuant to Title 22, California Code of Regulations, Section 64432(m) or (n) for inorganics, or Section 64445(d) for organics. 6. A standby source which has previous monitoring results indicating nitrate or nitrite levels equal to or greater than 50 percent of the I ICL shall collect and analyze a sample for nitrate and nitrite annually. In addition, upon activation of such a source, a sample shall be collected, analyzed for these chemicals and the analytical results reported to the State Board within 24 hours of activation. 7. A standby source for which perch'orate has been previously detected shell have a sample collected :and analyzed for perchlorate annually. Additionally, upon City Council 22 — 8 10/20/2026 Mr_ Cesar Barrera - 6 - July 30, 2026 activation of such a source, a sample shall be collected and analyzed for p9rchlorate, and the analytical result shall be reported to the State Board within 4 hours of activation. & Within three days after the short-term emergency use of a standby source, the City must notify the Division_ The notification must include information on the reason for and duration of the use_ 9. The City must followthe approved Carthe NltrateJPFAS Blending and Monitoring Plan when temporarily using Well 32. 10.f esuIts of PFAS monitoring for stan dby We[Is 27, 28, 31., 32, and 41 must be reported to the Division via California Laboratory Intake Portal (CLIP). All PFAS detections must be reported in the Consumer Confidence Repor. if the standby Well(s) is/are used for short-term emergencies. 11 .If the standby Wells 27, 26, 31, 32, and 41 islare used and any monitoring undertaken results in the water delivered to customers exceed a PFAS response level (PL) as determined using the methodology in the Notification Level Issuance document, the City must provide public notification on the F L exceedance. 12.The status of the designated standby sources must not be changed to that of regular sources of drinking water supply unless the sources meet all existing drinking water standards and approval is obtained from the Division in advance. If you have any questions, please contact Minliang Shih at (714) 8-4707 or Mi n li ang_Shih rc)vvaterboards.ca_gov. S ncerely, f� - Digitally signed by Oliver C. Paeifico, P.E. ` Date:2026.07.30 15:46,44-0TO0' Oliver C. Pacifico, P.E_ District Engineer Santa Ana District cc: Grange County Health Care Agency Patrick Versluis Orange County Dater District Robert Hernandez City of Santa Ana City Council 22 — 9 10/20/2026 I i State of California—Health and Human Services Agency �. California Department of Public Health r x � !)CDPH MARK B HORTON,MD,MSPH ARNOLD SCHWARZENEGGER Director Governor May 26, 2010 Mr. Ray Burk Water Resources Manager City of Santa Ana, 220 South Daisy Avenue Santa Ana, CA 92703 Dear Mr. Burk: SYSTEM NO. 3010038, DOMESTIC WATER PERMIT NO. 05-08-10P-001 am pleased to forward you the Domestic Water Supply Permit, the Certification of Issuance, and the accompanying Engineering Report for the City of Santa Ana to continue the operation of the City of Santa Ana Water System, an existing community water system serving the City of Santa Ana. Please acknowledge receipt of this permit and your willingness to comply with the permit conditions in writing within 15 days. If you have any questions regarding this permit, please call this office at (714) 558-4410. Sincerely, VtUA-i Oliver C. Pacifico, P.E. District Engineer Santa Ana District cc: Orange County Environmental Health -Southern California Drinking Water Field Operations Branch,Santa Ana District 9r',\A/c +C­+n Any RA/H Ri iilriing 9A, Rnnm 49R. Cana Ana, ( A Q97ni City Council Telephone: (714)558-4410 22ax:(p(D4)567-7262 10/20/2026 Internet Address: www.cdph.ca.gov i i Mr. Ray Burk Page 2 May 26, 2010 bcc: Permit Region Reading BB - PICME 1005-COSA-Permit Cover Letter-OCP.doc OCP/BB i City Council 22 — 11 10/20/2026 i STATE OF CALIFORNIA I DOMESTIC WATER SUPPLY PERMIT Issued To OF Ty City of Santa Ana ��P:.• '' ° Ex" `„ s� Public Water System No. 3010038e ' �-..., •-,,�'•„ J-ire^m� By The California Department of Public Health, gLIFORN\P Division of Drinking Water & Environmental Management Branch PERMIT NUMBER 05-08-10P-001 DATE: May 26, 2010 1 WHEREAS; 1. The City of Santa Ana currently operates .the water system under the authority of Domestic Water Supply Permit No. 04-08-97P-001 issued by the California Department of Public Health (Department) on January 6, 1997. Because of the age of the existing permit and multiple changes to the City's water system as documented in four amendments, the Department initiated a permit action. The City of Santa Ana submitted a permit amendment application dated March 21, 2010 to the California Department of Public Health to convert the City's wellhead chlorination facilities from using Chlortec onsite sodium hypochlorite generation system to I MicroChlor onsite sodium hypochlorite generation system. The issuing of a-permit allows the City to continue the operation of the City of Santa Ana Water System, a public water system. 2. This public water system is known as the City of Santa Ana Water System whose headquarters is located at 220 S. Daisy Avenue, Santa Ana, CA 92703. 3. The legal owner of the City of Santa Ana Water System is the City of Santa Ana. The City of Santa Ana, therefore, is responsible for compliance with all statutory and regulatory drinking water requirements and the conditions set forth in this permit. 4. The public water system for which the permit application has been submitted is as j described briefly below (a more detailed description of the permitted system is described in the attached Permit Report): City Council - 1 -22 — 12 10/20/2026 I i The City of Santa Ana Water System is a community water system located in north central Orange County, California. The City serves approximately 353,184 people through 44,578 service connections. The City obtains water from a variety of sources including 12 groundwater wells and treated surface water imported from four connections with the Metropolitan Water District of Southern California (MWDSC). The approved treatment facilities include wellhead chlorination facilities and nitrate blending facilities at the Walnut and Bristol Reservoirs. The City's distribution system conveys water to its customers through about 450 miles of distribution mains. The City has a total of ten reservoirs with a combined storage capacity of 49.3 million gallons (MG) and seven pump stations that are located throughout its service area. 5. The service area of the City of Santa Ana shall be shown on the service area map in Appendix 3 of the attached Permit Report. And WHEREAS; 1. The City of Santa Ana has submitted all of the required information relating to the operation of the City of Santa Ana. 2. The California Department of Public Health has evaluated all of the information submitted by the City of Santa Ana and has conducted a physical investigation .of the City of Santa Ana. i i 3. The California Department of Public Health has the authority to issue domestic water supply permits pursuant to Health and Safety Code Section 116540. I THEREFORE: The California Department of Public Health has determined the following: 1. The City of Santa Ana meets the criteria for and is hereby classified as a community water system. i 2. The applicant has demonstrated that the City of Santa Ana has sufficient source capacity to serve the anticipated water demand for at least ten years. 3. The design of the proposed water system complies with the Water Works Standards and all applicable regulations. i 4. The applicant has demonstrated adequate technical, managerial, and financial capacity to operate reliably the proposed water system. 5. Provided the following conditions are complied with, the City of Santa Ana should be capable of providing water to consumers that is pure, wholesome, and potable and in compliance with statutory and regulatory drinking water requirements at all times. i City Council - 2 -22 — 13 10/20/2026 i THE CITY OF SANTA ANA IS HEREBY ISSUED THIS DOMESTIC j WATER SUPPLY PERMIT TO OPERATE THE CITY OF SANTA ANA j WATER SYSTEM. The City of Santa Ana shall comply with the following permit conditions: Safe Drinking Water Act 1. The City shall comply with all the requirements set forth in the California Safe Drinking Water Act, California Health and Safety Code, and any regulations, standards or orders adopted thereunder. Approved Sources 2. The only sources approved for use are listed in Table I, Table Il, and Table III. Table I — Groundwater Sources Well PS Code Status Capacity, Pump water to Name 9pm Well 16 3010038-018 Active 1,500 Walnut Reservoir Well 18 3010038-019 Active 2,290 John Garthe Reservoir Well 20 3010038-021 Active 3,020 West Reservoir Well 21 3010038-022 Active 2,890 West Reservoir Well 24 3010038-025 Active 1,690 John Garthe Reservoir Well 26 3010038-026 Active 1,290 East Station Reservoir . Well 27 3010038-027 Active 2,080 Crooke Reservoir Well28 3010038-028 Active 2,760 System Well 29 3010038-029 Active 2,520 Walnut Reservoir Well 30 3010038-030 Active 2,530 West Reservoir Well31 3010038-031 Active. 3,020 System Well 33 3010038-033 Active 2,240 System Well 34 3010038-034 Active 2,850 Walnut Reservoir Well 35 3010038-037 Active 1,510 System Well 36 3010038-035 Active . 2,200 System Well 37 3010038-038 Active 3,600 John Garthe Reservoir Well38 3010038-039 Active 2,300 System Well39 3010038-061 Active 3,000 System Well40 3010038-073 Active 2,500 System Well41 3010038-074 Active 3,000 System City Council - 3 - 22 — 14 10/20/2026 I. Table II — Purchased Treated Surface Water Sources Capacity 2007 Source Location (cfs) Actual PS Code Usage (cfs) SA-1 Bristol St. and Santiago Creek 6.5 5.8 3010038-066 SA-2 Bristol St. and First St. 9.7 6.5 3010038-067 SA-3 Bristol St. and McFadden 6.5 5.8 3010038-068 SA-4 Bristol St. and Warner Ave. 6.5 2.6 3010038-069 SA-5 Bristol St. and Alton Ave. 12.9 3.9 3010038-070 SA-6 Tustin Ave. and Santa Clara 12.9 7.8 3010038-071 SA-7 Redhili Ave. and Warner Ave. 16.2 3.9 3010038-072 Table III — Emergency Interconnections with Neighboring Systems Agencies Size Capacity Location Type (I n. gpm Mesa Consolidated 12 5,300 Harbor Blvd and Sunflower Outflow Mesa Consolidated 12 5,300 Smalley Road and Inflow Sunflower Avenue Mesa Consolidated 12 5,300 Bear Street and Sunflower Inflow Avenue City of Fountain Valley 8 2,400 Edinger Ave. and Driftwood Inflow Drive City of Orange 8 2,400 Lawson Way Inflow City of Tustin 8 2,400 McFaden and Village Way Inflow City of Garden Grove 6 900 Fairview and Huckleberry Inflow i i City Council - 4 -22 — 15 10/20/2026 i i Approved Treatment Facilities I 3. The only treatment facilities that are approved for the system are those listed in Table IV: I Table IV-Treatment Facilities Treatment Facility Treatment Processes Wellhead Chlorination Precautionary chlorination with 0.8 percent sodium hypochlorite solution from onsite generators at all wells. Nitrate Blending Well 16 blending with Wells 29 and 33 At the Walnut reservoir. Nitrate Blending Well 18 blending with Wells 24, 36, and 39 At the Bristol reservoir. I Permit Amendment 4. No changes, additions, or modifications shall be made to the sources or treatment facilities outlined in Conditions 2 and 3 unless an amended permit has first been obtained from the Department. Operator Certification 5. All personnel who operate the distribution system of the City of Santa Ana shall be certified in accordance with Section 63770, Title 22 of the California Code of Regulations (CCR). The City of Santa Ana is classified as a D5 water distribution system. Therefore, the Chief and Shift Operator(s) for the distribution facilities shall have, at minimum, D5 and D4 certification, respectively. 6. All personnel who operate the City's treatment facilities shall be certified in accordance with Section 63765, Title 22 of the CCR. The iron and manganese sequestering equipment at Well 16 is classified as a T3 treatment facility. The minimum grade requirement for the Chief and Shift operator(s) for this treatment facility is T3 and T2 certification, respectively. Water Quality i j 7. All water supplied by the City for domestic purposes shall meet all Maximum Contaminant Levels (MCLs) established by the Department. If the water quality does not comply with the California Drinking Water Standards, treatment shall be provided to j meet standards. City Council - 5 -22 — 16 10/20/2026 8. The City shall ensure that all water quality monitoring is completed in accordance with Title 22, Chapter 15 of CCR and the Department's Vulnerability Assessment and Monitoring Frequency Guidelines. 9. Unless specified by regulations, all water samples for compliance purposes shall be analyzed by a laboratory certified by the Department's Environmental Laboratory Accreditation Program (ELAP)for each analytical technique. 10. Except for bacteriological analyses and constituents without chemical storet numbers, all water quality monitoring results obtained at a certified laboratory shall be submitted to the Department by Electronic Data Transfer (EDT) using the PS Codes listed in Condition 2. Cross-Connection Control Program 11. The City shall comply with Title 17 of the CCR to prevent the water system and treatment facilities from being contaminated by possible cross-connections. The City shall maintain a program for the protection of the domestic water system against backflow from premises having dual or unsafe water systems in accordance with Title 17. All backflow prevention devices shall be tested annually. Treatment Plant Operation and Maintenance 12. All treatment facilities shall be- operated in accordance with a Department-approved Operation, Monitoring, and Maintenance Plan. 13. All treatment facilities shall be maintained in accordance with the manufacturer's specification. 14. Pursuant to § 64590, Title 22 of the California Code of Regulations (CCR), no chemical or product shall be added to drinking water by the City unless the chemical or product is certified as meeting the specifications of NSF International/American National Standard Institute (NSF/ANSI) 60-2005 (Drinking Water Treatment Chemicals-Health Effects). 15. Pursuant to § 64591, Title 22 of the CCR, the City shall not use any chemical, material, lubricant, or product that may come into contact with the drinking water that has not been tested and certified as meeting the specifications. of NSF/ANSI 61-2005 / Addendum 1.0-2005. This includes process media (carbon, sand), protective materials (coatings, linings, liners), joining and sealing products (pipes, tanks, fittings), and mechanical devices used in the production, treatment or distribution of drinking water and treatment/transmission/distribution systems (valves, chlorinators, separation membranes). Annual Report 16. The City shall submit an Annual Report on the status and condition of the domestic I water system as directed by the Department. City Council - 6 -22 — 17 10/20/2026 This permit supersedes all previous domestic water supply permits issued for this public water system and shall remain in effect unless and until it is amended, revised, reissued, or declared to be null and void by the California Department of Public Health. This permit is non- transferable. Should the City of Santa Ana undergo a change of ownership, the new owner must apply for and receive a new domestic water supply permit. I Any change in the source of water for the water system, any modification of the method of treatment as described in the Permit Report, or any addition of distribution system storage reservoirs shall not be made unless an application for such change is submitted to the California Department of Public Health. This permit shall be effective as of the date shown below. FOR THE CALIFORNIA DEPARTMENT OF PUBLIC HEALTH U6 Oliver Pacifico, P.E. District Engineer Santa Ana District i Dated: May 26, 2010 I City Council - 7 - 22 — 18 10/20/2026 California Department of Public Health Division of Drinking Water and Environmental Management Drinking Water Field Operations Branch Engineering Report For Consideration of the Permit Application from City of Santa Ana Orange County May 26, 2010 Prepared By: Bruce Berger, Sanitary Engineer Santa Ana District Reviewed and Approved By: q Oliver Pacifico, P. , Dist ict Engineer Santa Ana District City Council 22 — 19 10/20/2026 TABLE OF CONTENTS SECTION PAGE I. INTRODUCTION 1 A. Purpose of Report 1 B. Permit Status 1 C. Brief Description of System 2 D. Area Served 2 E. Source of Information 2 II. INVESTIGATION FINDINGS 2 A. Sources of Supply 2 1. Groundwater 3 2. Treated Surface Water 4 3. Emergency Interconnections 5 B. Treatment 7 a. Bristol (Garthe) Reservoir Nitrate Blending Facilities 8 b. Walnut Reservoir Nitrate Blending Facilities 9 C. Distribution System 9 1. Storage Reservoirs 9 i 2. Pressure Zones 11 5. Pipelines 13 6. Monitoring Equipment and Reliability 13 D. Operation and Maintenance 13 2.1 Distribution System Operator Certification 14 i E. Water Quality and Monitoring Plan 17 2. Surface Water Treatment Rule (SWTR) 17 4. Lead and Copper Rule 17 F. Environmental Review Error! Bookmark not defined. III. IMPROVEMENT PROGRAM 19 IV. APPRAISAL OF SANITARY HAZARDS AND SAFEGUARDS 19 V. RECOMMENDATIONS 20 VI. APPENDICES 23 i City Council 22 — 20 10/20/2026 i I Engineering Report— City of Santa Ana Pagel of 25 I. INTRODUCTION A. Purpose of Report i The City operates the water system under the authority of Domestic Water Supply Permit No. 04-08-97P-001 issued by the California Department of Public Health (Department) on January 6, 1997. Since the issuance of the existing permit, five permit amendments have been issued to the City by the Department. Because of the age of the existing permit and multiple changes to the City's water system as documented in the four amendments, the Department initiated a permit action. i This report is to describe and evaluate the water system and to make i recommendations regarding the issuance of a revised domestic water supply 1 permit to the City. In addition, the City of Santa Ana (City) submitted a permit 7 amendment application dated March 21, 2010 to convert the City's wellhead chlorination facilities from using Chlortech onsite sodium hypochlorite generators to using Microchlor onsite sodium hypochlorite generators. B. Permit Status The City is currently operating under the authority of Water Supply Permit No. 04- 08-97P-001 issued by the Department on January 6, 1997. As summarized in Table 1, four permit amendments have been issued since the issuance of the existing permit. Table 1. Summary of permit and amendments i Permit/Amendment No. Date Purpose 04-08-97P-001 January 6, 1997 Water Supply Permit Permit Amendment 1 November 9, 1999 To convert Well 28 from gas Well 28 to Liquid NaOCI chlorine to liquid sodium hypochlorite generation system for disinfection Permit Amendment 2 September 8, 2000 To convert the gaseous chlorine Wells 27, 32, and 35 to feed systems at Wells 27, 32 and Liquid NaOCI 35 to liquid sodium hypochlorite on-site generation systems Permit Amendment 3 July 18, 2002 Add Well 39 as additional water Add Well 39 source PA #05-08-07PA-047 December 11, 2007 Add wells 40 and 41 as additional Add Wells 40 AND 41 water sources City Council 22 — 21 10/20/2026 Department of Public Health Drinking Water Field Operations Branch. Engineering Report—City of Santa Ana Page 2 of 25 I I C. Brief Description of System The City is a community water system located in central Orange County, California. It serves a population of approximately 351,697 through 44,677 service connections in the city of Santa Ana in Orange County. The water system includes 20 active groundwater wells (Wells 16, 18, 20, 21, 24, 26, 27, 28, 29, 30, 31, 33, f 34, 35, 36, 37, 38, 39, 40, and 41) with a combined capacity of 62 million gallons per day (MGD), seven purchased treated surface water connections (SA-1, SA-2, SA-3, SA-4, SA-5, SA-6 and SA-7) to the Metropolitan Water District of Southern California (MWDSC) with a combined capacity of 38.1 MGD, ten reservoirs with a combined capacity of 49.3 million gallons (MG), seven pump stations, and two pressure zones in the distribution system with approximately 450 miles of pipelines. The City's distribution system is also connected to the water systems of the City of Fountain Valley, City of Orange, City of Tustin, City of Garden Grove, and Mesa Consolidated Water District for emergency supply. A system map is provided in Appendix 2. D. Area Served The City's service area is approximately 30.6 square miles which includes nearly the entire City of Santa Ana. The City service area consists of primarily residential zones with some commercial and industrial developments. The service area elevations range from about 60 feet above mean sea level (ft-msl) to 90 ft-msl. E. Source of Information Information needed for the preparation of this report was obtained from the Department's files, the City of Santa Ana's 2008 Water Master Plan, field reviews of the water system on March 2, 3, and 9, 2010, interviews with Mr. Nabil Saba, P.E. Water Production Supervisor, and interviews and email exchanges with Mr. Thomas Dix, Water Quality Supervisor. The investigation, analysis and preparation of this report were undertaken by Bruce Berger, Sanitary Engineer with the Santa Ana District. The report was reviewed and approved by Oliver Pacifico, P.E., District Engineer, Santa Ana District. i II. INVESTIGATION FINDINGS A. Sources of Supply The City's approved sources of supply include groundwater pumped from 20 active wells and treated surface water imported from seven connections with MWDSC. City Council 22 — 22 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report—City of Santa Ana Page 3 of 25 1. Groundwater The City has 20 active groundwater wells as summarized in Table 2 below. As indicated in Table 2, nine wells pump directly into the distribution system while the remaining eleven wells pump into storage reservoirs. Table 2. Summary of Approved Groundwater Sources Well PS Code Capacity, Sanitary-seal Pump water to Name 9pm depth ft Well 16 3010038-018 1,500 None Walnut Reservoir Well 18 3010038-019 2,290 Unknown John Garthe Res. Well 20 3010038-021 3,020 120 West Reservoir Well 21 3010038-022 2,890 127 West Reservoir Well 24 3010038-025 1,690 Unknown John Garthe Res Well 26 3010038-026 1,290 96 East Station Res Well 27 3010038-027 2,080 100 Crooke Reservoir Well28 3010038-028 2,760 100 System Well 29 3010038-029 2,520 100 Walnut Reservoir Well 30 3010038-030 2,530 100 West Reservoir Well31 3010038-031 3,020 235 System Well 33 3010038-033 2,240 60 System Well 34 3010038-034 2,850 325 Walnut Reservoir Well35 3010038-037 1,510 60 System Well36 3010038-035 2,200 440 System Well 37 3010038-038 3,600 350 John Garthe Res Well 38 3010038-039 2,300 350 System Well39 3010038-061 3,000 50 System Well40 3010038-073 2,500 421 System Well41 3010038-074 3,000 421 System All well sites are secured with fence and are equipped with intrusion alarms. All but Well 16, 18, and 24 have sanitary seals with depth varying from 50 feet to 440 feet. Well 16 has no sanitary seal, and it is unknown whether wells 18 and 24 have sanitary seals. All wellheads are above ground and have surface seals. All wells are fitted with pump to waste line and sampling taps. All the City's pumps are powered by electric motors. All wells are equipped with chlorination equipment. All chlorination facilities use sodium hypochlorite generators for disinfection. Well 41 is one of the eight wells in the Orange County Groundwater Storage Program. OCWD is selected as the lead agency responsible for implementation of the design and construction of individual wells to be used to extract the 20,000 acre-feet per year of MWDSC stored water. The total pumping capacity for the wells is 48,790 gpm (70.3 MGD). A copy of the well data sheets is provided in Appendix 3. City Council 22 — 23 10/20/2026 Department of Public Health Drinking Water Field Operations Branch i I Engineering Report— City of Santa Ana Page 4 of 25 Orange County Groundwater Basin Most wells were drilled approximately between 650 feet and 1 ,000 feet into the Orange County Groundwater Basin aquifer. The aquifer underlies the northern half of Orange County and covers an area of approximately 350 square miles. The aquifer extends over 2,000 feet deep and consists of a complex series of interconnected sand and gravel formations. The aquifer is primarily supplied by runoff from the Santa Ana River watershed, imported water percolated into the aquifer, and recycled wastewater discharges from wastewater treatment plants percolated and directly injected into the aquifer. The basin is not adjudicated and is managed by Orange County Water District (OCWD). The OCWD manages the basin through pumping management and i recharge management programs. Recharge management programs replenish the aquifer by natural or artificial means. Natural recharge includes infiltration of precipitation and runoff. Artificial recharge occurs at developed percolation ponds and via groundwater injection through the Talbert and Alamitos Barriers. The OCWD manages groundwater pumping by establishing a Basin Production Percentage (BPP). Each year, the OCWD recommends a BPP for its 20 groundwater producers within the basin. The BPP is calculated by dividing the producers' optimum groundwater production by the estimated total water demand. I OCWD collects from groundwater producers a replenishment assessment (RA) fee of $237 per acre-feet of groundwater pumped from the basin (2008-2009 rate). i When pumping above the BPP level, groundwater producers must pay an jadditional basin equity assessment (BEA) of $322/acre-feet. For example, the City of Santa Ana's BPP during the period of July 2006 - June 2007 is 69% which means that the City could meet 69% of its total water demand by groundwater pumping without paying BEA. The cost of the City produced groundwater is approximately $367/acre-feet when pumping below the BPP. This cost could increase to $699/acre-feet if the BPP is exceeded. The cost of imported water from MWDSC is $508/acre-feet. 2. Treated Surface Water In 2008 Calendar Year, MWDSC supplied approximately 30% of the City's water (treated surface water) through seven connections and the remaining 70% was supplied by local groundwater wells. The City receives water from two different feeders, which increases its source reliability. Weymouth Plant supplies treated surface water through the Orange County Feeder to SA-1, to SA-2, SA-3 (off at this time), SA-4 and SA-5 connections. Diemer Plant supplies treated surface water through the East Orange County Feeder to SA-6 and SA-7 connections. The following table presents a summary of the City's MWDSC connections. I City Council 22 — 24 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 5 of 25 Table 3 — Purchased Treated Surface Water from MWDSC i Normal Usage Name Name Location Zone (MGD) . i SA-1 Bristol Bristol St. and Santiago Creek Lower 5.2 i SA-2 First First St. and Bristol St. Lower 5.2 SA-3 Mc Fadden Bristol St. and McFadden Lower 5.2 SA-4 Warner Bristol St. and Warner Ave. Lower 4.9 SA-5 Alton Bristol St. and Alton Ave. Lower 4.9 . SA-6 Santa Clara Tustin Ave. and Santa Clara Upper 7.8 SA-7 Redhill Redhill Ave. and Warner Ave. Lower 4.9 Total 38.1 3. Emergency Interconnections The City maintains seven emergency interconnections with neighboring water systems to ensure a backup water supply in emergency events. Each i interconnection consists of a pipeline with two gate valves that need to be opened by each agency to allow water transfer. The direction of the flow is dependent upon the difference in hydraulic grade line (HGL) between the two agencies. Table 4 summarizes the sizes and capacities of these connections and their locations. , Table 4 — Summary of Connections to Other Systems Connection with Size, (inches),, , Capacity`(gpm) Type Mesa Consolidated Emergency/12 inch 3,600 Outflow Mesa Consolidated Emergency/12 inch 1,500 Inflow Mesa Consolidated Emergency/12 inch 1 ,500 Inflow City of Fountain Valley Emergency/8 inch 1,600 Inflow City of Orange Emergency/8 inch 900 Inflow City of Tustin Emergency/8 inch 900 Inflow City of Garden Grove Emergency/6 inch 900 Outflow City Council 22 — 25 10/20/2026 Department of Public Health Drinking Water Field Operations.Branch Engineering Report— City of Santa Ana Page 6 of 25 4. Adequacy of Supply The City's historical water consumption data for the last five years is summarized in Table 5. Table 5 indicates that the maximum day demand (MDD) occurred in 2008 at 65.5 MG, while the monthly maximum demand occurred in 2007 at 1,892 MG. Table 5 - Summary of Historical Water Consumption Data 2004 2005 2006 2007 2008 Service Connections 44,562 44,619 44,641 44,578 44,677 Population Served 337,977 337,977 343,700 353,184 353,184 Annual Water Usage, MG 16,566 15,993 16,032 14,722 13,541 Max. Month Demand, MG 1,736 1,646 1,607 1,892 1,362.5 Max. Day Demand, MG 59.0 56.5 56.6 50.25 65.5 In accordance with Section 64554, Title 22 California Code of Regulations, the adequacy of the City's domestic water supply is evaluated under the following I scenarios: i 1 . Meet the MDD with the largest well (Well 37), which has a capacity of 3,600 gpm or 5.2 MGD, out of service. Groundwater supply capacity not including Well 37 is 65.1 MGD. 2. Meet the MDD with the largest MWDSC connection (SA-6) based on actual use, which in 2007 was 7.8 MGD, out of service. Treated surface water capacity without the SA-6 is 30.3 MGD. 3. Meet four hours of peak hourly demand with all sources and storage. For the purpose of adequacy evaluation, peak hour demand can be calculated using a peak factor of 1.5: 65.5 MG / 24 hr. X 1.5 = 4.1 MG. Four hours of peak hourly demand amounts to:,4.1 MG x 4 = 16.4 MG As indicated in Table 6, in all scenarios, the ratios between supply and demand volumes are greater than one. The City's water supply is adequate. Table 6 —Adequacy of Supply Surface Total Demand Groundwater Supply/Demand Scenario Water Supply - (MG) Supply (MG) Ratio (MG) Supply (MG) (MG) 1 65.5 65.1 38.1 103.2 1.6 City Council 22 — 26 10/20/2026 i Department of Public Health Drinking Water Field Operations Branch I Engineering Report—City of Santa Ana Page 7 of 25 Surface Total Demand Groundwater Supply/Demand Scenario Water Supply' (MG) Supply,(MG) Ratio (MG) Supply,(MG) (MG). 2 65.5 70.3 30.3 100.6 1.5 3 16.4 11.7 6.4 18.1 1.1* I *Excluding 49.3 MG of storage. With storage, the ratio is 4.1. B. Treatment The approved treatment facilities include the well chlorination facilities. 1. Chlorination Facilities Chlorination facilities are operated to maintain a minimum 0.2 to 0.4 mg/L chlorine residual at the weekly bacteriological sample sites located throughout the distribution system. When reservoirs are supplied by more than one well, then at least one of the wells is equipped with a chlorinator to provide reliability in case of equipment failure or maintenance activities. Walnut Reservoir is an exception because the wells discharge into a common header and are chlorinated at the inlet of the reservoir. The City uses On-site Sodium Hypochlorite Generation (OSHG) systems to treat all groundwater. Each chlorine generating system consists of water softening system, brine-salt dissolving tank, brine proportioning pump, electrolytic cells, 500 to 1,000-gallon day-storage tank for sodium hypochlorite solution, and feed metering pump. Water for the brine make-up solution, in each system is obtained from the well discharge line. Water is then softened to remove the calcium and magnesium hardness. The brine solution is made from table salt in the brine tank. The brine tank has two intake ports. The brine is extracted by a brine pump from the ports and fed through the electrolytic cells. In the cells, electrolysis takes place as a low- voltage direct current is passed across the electrodes. As the flow through the cells continues, hydrogen gas and 0.8% hypochlorite solution are generated. The hydrogen gas is vented to atmosphere and the sodium hypochlorite is stored in the day tank. From the day tank, the solution is fed into the well discharge line where water goes into the distribution system or in some situations the chlorine solution is injected into a common line of several wells that blend into a reservoir. The sodium hypochlorite generation is continuous and is controlled by the level of the solution in the day tank. When the solution reaches a certain level in the day tank, generation of sodium hypochlorite stops. When the solution goes down in the tank to a designated level due to usage, the generation process starts again. City Council 22 — 27 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report—City of Santa Ana Page 8 of 25 Each facility is capable of providing precautionary chlorination dosage at normal flows. In emergencies, the chlorination systems need to be augmented with the addition of higher concentration chlorine solution to provide the necessary chlorine dosage. The chlorine feed metering pump is usually set to feed at constant rate. The pump is equipped with a feed calibration setup to allow the operator to establish a correlation between the pump settings and the feed rates at different solution strengths. Dosages can be increased by increasing the feed rate of the pump and/or by using higher concentration solution. It has been documented that on-site sodium hypochlorite generation units produce low concentrations of Chlorine, Chlorine dioxide, Chlorates, Chlorites, and Bromates. With optimized operation and the use of the appropriate raw material (salt), the unit can produce chlorinated water that meet all established maximum contaminant levels and California action levels for the above chemicals. The sodium hypochlorite solution pump feeds the hypochlorite solution at a constant feed rate to achieve a total chlorine residual in the distribution system of 0.2 to 0.4 mg/L. The solution is injected into the well discharge line to the distribution system. Feed rates are adjusted based upon the imported MWDSC water if used along with groundwater sources or if groundwater is the only source of supply. The City personnel indicated that they have no problems maintaining detectable chlorine residual in the distribution system since MWDSC increased the total chlorine residual in the water that they sell to the City. The City's SCADA system monitors the wells' operation. The well sites are visited daily and the chlorine residual is tested daily at the discharge line of the wells. Certified water treatment plant operators that have been certified by the Department at the appropriate grade levels, operate the treatment facilities. The City is in the process of preparing a written Operations Plan for approval by the Department. The plan must include, but not limited to, facility inspections, treated water quality monitoring and testing, calibration of feed pumps, preventive maintenance, emergency disinfection, and records keeping. The system operators must also be trained to be familiar with the hydrogen gas safety. 1­12-gas combines ready with oxidants (02) in violent, explosive reaction. Proper ventilation of the H2 to the atmosphere is essential. The City has marked the sites with proper warning signage. 2. Nitrate Treatment Facilities a. Bristol (Garthe) Reservoir Nitrate Blending Facilities Bristol Reservoir is located in the City's lower distribution system pressure zone and has a total storage capacity of 6.0 MG. The reservoir receives water from Well Nos. 18, 24, 36 and 39. Well Nos. 18 and 24 have shown high nitrate levels, however these high levels have remained below the State MCL. Both wells are blended with Well Nos. 36 and 39 in the Bristol Reservoir. Well No. 18 is blended with Well No. 36 and Well No. 24 is blended with well No. 39. City Council 22 — 28 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 9 of 25 Each of the wells is connected to the City's SCADA which controls the operation of the sources. The process control loop description for the operation of the four wells stagger starts the sources. Well No. 36 is designated as the primary source. Wells No. 18 cannot start unless Well No. 36 is running. Well No. 39 is designated as the primary source. Wells No. 24 cannot start unless Well No. 39 is running. Based upon production rates of each source and historical nitrate concentrations, the water discharged to the Garthe Reservoir should remain in the range of 8 to 24 mg/L as nitrate. On July 6, 2004, the Department notified the City with a letter regarding the reclassification of this treatment facility as a T3. A copy of the revised Treatment Facility Classification is attached. b. Walnut Reservoir Nitrate Blending Facilities Walnut Reservoir is located in the City's lower distribution system pressure zone and has a total storage capacity of 7.0 MG. The reservoir receives water from Well Nos. 16, 29, and 33. Each of the wells is connected to the City's SCADA, which controls the operation of the sources. The process control loop description for the operation of the three wells stagger starts the sources. Since the destruction of Well No. 13, Well No. 33 has been pumping directly to the reservoir without designated order like before. That is Well No. 13 cannot start unless Well No. 33 is running. Well No. 29 is designated as the primary source. Wells No. 16 cannot start unless Well No. 29 is running. Based upon production rates of each source and historical nitrate concentrations the water discharged to the Walnut Reservoir should remain in the range of 8 to 24 mg/L as nitrate. The monthly reports of the nitrate-monitoring levels from the City to this Department from June 2008 to June 2009 are attached. The City has a field nitrate analyzer (HACH 850 Colorimeter) for evaluating nitrate concentrations of its well sources and reservoir outlets. Currently, weekly samples are collected at reservoir outlets using the field test kit. Monthly State certified laboratory samples are being collected from blended wells sources and the outlet of both reservoirs for comparison with field test kit results. C. Distribution System 1. Storage Reservoirs The City maintains and operates ten domestic water reservoirs with a total capacity of 49.3 MG. Several reservoirs have hose bibbs that are used to collect bacteriological water quality samples from common inlet/outlet piping. Water from these reservoirs can be readily transferred from one pressure zone to another. Table 7 — Summary of Reservoir Data Storage Capacity Discharges Type Receives From FacilityMG) To Well Nos. 18, 24, 36, Bristol (John Lower Pressure Garthe) Reservoir 6.0 Concrete 39, Lower Pressure Zone j Zone,& MWDSC SA-1 City Council 22 — 29 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 10 of 25 i (when needed) New North Bristol 5.0 Concrete Well Nos. 18, 24, 36, Reservoir 39, Lower Pr. Zone New South Bristol 5.0 Concrete Well Nos. 18, 24, 36, Reservoir 39, Lower Pr.Zone Elevated Tank 1.0 Steel Lower Pressure Zone South Reservoir 6.0 Concrete Well No. 34 Lower Pressure Zone Well Nos. 16, 29, 33, Walnut Reservoir 7.0 Concrete Lower Pressure Zone, & MWDSC SA-2 West Tank 6.0 Steel Well Nos. 20, 21, & 30 East Tank 6.0 Steel Well Nos. 26, & Lower Pressure Zone Cambridge 1.3 Concrete Upper Pressure Zone Reservoir Well No. 27, 28, Upper Pressure Crooke Reservoir 6.0 Concrete & Upper Pressure Zone Zone TOTAL 49.3 CAPACITY Based on the provided historical water usage data in Table 1, the average City's maximum day water demand during the last five years is 56.86 MGD. The City would be able to supply this average maximum day demand for approximately 20 hours through the use of only its distribution storage reservoirs, assuming that all reservoirs were full. MWDSC recommends that its member agencies maintain a minimum of seven days of storage as indicated in the previous inspection report. Since the City has its own sources it may not be as crucial to meet the entire seven-day storage requirement, but additional storage is recommended to increase the City's storage capability. The City needs to update its master plan and evaluate storage and production requirements to reliably meet water system demands. The September 1987 master plan indicated that reservoir storage would have to be increased by 200 MG. This will provide the City with approximately 4 days of storage under peak flow conditions with no fire flows or sources in use. Seven of the City's ten reservoirs are constructed of reinforced concrete and do not require to be coated to prevent corrosion. The City's remaining three steel reservoirs have epoxy-coated walls and roofs. The floor within the reservoir is coated with coal tar. The Last time the floor of the South Reservoir was re-coated with tar-coating material, objectionable taste and odor forced the City to remove the tar coating and replaced it with properly installed tar coating that did not generate problems of taste and odor. The reservoir is now used in the system. The City's SCADA system controls the operation of wells, and MWDSC connection flow rates based upon reservoir water levels and water quality data. The City inspects the interior of each of its reservoirs once a year and cleans and repairs reservoirs based upon inspection findings. City Council 22 — 30 10/20/2020 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 11 of 25 2. Pressure Zones The City's distribution system is comprised of two major distribution system pressure zones. The Upper Pressure Zone is bounded by the Garden Grove and Santa Ana Freeway and the Lower Pressure Zone located in the southern portion of the City. Pressures in the distribution system range between 35 and 110 psi. The water sources and total quantity of storage in each zone is summarized in the table below. Table 8 — Summary of Pressure Zones Zone Pressure Range Source of Supply Available Service (psi) Storage MG Connections Upper 35 to ) Well Nos. 27, 28 & 38 7 3 5,000 and SA-6 11 /o) Well Nos. 16, 18, 20, 21, 24, 26, 29, 30, 31, 32, 33, 34, 35, 36, 38, 39, 40, & 41 and SA-1, 39,641 42.0 Lower 35 to 110 SA-2, SA-3 (off), SA-4, (89%) SA-5, & SA-7. Also from Upper Zone through four pressure control valves System 35 to 110 20 Wells + 7 MWD Sources 49.3 44,641 3. Pressure Regulating Stations The City currently has sufficient source and storage capacity to reliably meet consumer demands in each distribution system pressure zone. Water is transferred from one zone to another through distribution system booster stations and pressure reducing valve (PRV) stations. The City uses its pressure reducing and relief valves to isolate different pressure zones, relieve excess pressure in the higher-pressure zone, and supply water to the lower pressure zone. Each of these pressure-regulating stations is equipped with a bypass line that is controlled by a gate valve. Pressure reducing stations are summarized below. Table 8. Pressure Regulation Stations Station Location Configuration Name Two way valve — allows water from upper zone to lower PRV#3 Memory zone if pressure exceeds 65 psig or water to go from lower Lane zone to upper zone when pressure in lower zone exceeds 65 psi PRV#6 Grand One way valve from upper to lower zone Avenue City Council 22 — 31 10/20/2026 Department of Public Health Drinking Water Field Operations Branch i Engineering Report— City of Santa Ana Page 12 of 25 PRV#7 Lon One way valve from upper to lower zone Two way valve — allows water from upper zone to lower PRV#8 First zone if pressure exceeds 65 psig or water to go from lower Street zone to upper zone when pressure in lower zone exceeds 65 psig I I 4. Pump Stations The City has seven pump stations that deliver water to the distribution system from the reservoirs. All of the active pump stations were reviewed during the inspection. The pumps operate based on process logic controllers, which can also be controlled by the City's SCADA system. Each station is visited daily and the City retains a record of the daily visit. The pump stations are summarized in Table 9. Table 9 — Summary of Pump Station Data Horse- Station Booster Source of Capacity. Location` Power Number Number Power HP (GPM) 1 Electric 150 2,510 2 Electric 150 2,290 1 West Street 3 Electric 150 2,290 4 Electric 200 4,490 5 Electric 100 2,020 1 Electric 150 2,690 2 Electric 150 3,100 3 Electric 150 3;010 2 Garthe Street 4 Electric 200 4,260 5 Electric 250 3,590 6 Natural Gas 250 4,980 1 Electric 150 2,780 3 Cooke Street 2 Electric 150 2,690 3 Electric 150 2,740 1 Electric 75 1,480 4 Cambridge Street 2 Electric 75 1,440 3 Electric 75 1,530 5 East Street 1 Electric 125 2,650 2 Electric 125 2,600 6 South Street 1 Electric 150 2,240 2 Electric 150 2,240 1 Electric 200 3,500 2 Electric 200 3,500 7 Walnut Street 3 Electric 200 3,460 4 Electric 150 2,740 5 Electric 100 1,750 City Council 22 — 32 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 13 of 25 i In addition to distribution system pressure regulation stations, the City maintains pressure-regulating valves on each of its connections with MWDSC. 5. Pipelines The existing domestic water distribution system consists of approximately 450 miles of water mains ranging in diameter from 4 to 30-inches. Approximately 85% of the distribution system is comprised of cast or ductile iron pipe and a majority of the remainder is comprised of asbestos concrete pipe with some PVC and welded steel pipe. Some of the cast iron pipes have lead joints and are installed in corrosive soils. No pipes less than 8-inches in diameter are being installed for fire hydrant supplies. The entire pipeline system is comprised of a network of numerous loops except for approximately 10 miles of dead ends for local services. The water distribution system is laid out and sized to receive water from system reservoirs and MWDSC connections. Service connections within the distribution system range from 3/4 to 10-inches in diameter. The standard small service connection is constructed from 1-inch copper tubing with a 1-inch corporation and meter stops. Residential and other small services are metered by 3/4 and 1-inch meters. The water distribution system was initially constructed over 60 years ago. The majority of the original distribution system is still in service. The City is budgeting adequate funds every year for main replacement. The City continues with the main replacement. 6. Monitoring Equipment and Reliability The City has a comprehensive Water Quality Monitoring Plan dated September 24, 1996 that includes inorganic chemicals, organic chemicals, trihalomethanes (TTHMs), haloacetic acids (HAA5), radioactivity, general minerals and general physical parameters. The plan was updated effective January 1, 2002. The City is a member of the Orange County Water District, who performs almost all the tests required for groundwater sources on the City behalf. D. Operation and Maintenance 1. Organization and Personnel Raymond Burk, Principal Civil Engineer, oversees the Water Administration & Engineering in dealing with Engineering and Water Production and Supply. Nabil Saba (Senior Civil Engineer) supervises the Water Production and Supply daily activities. George Hunt (Water Quality Supervisor) supervises the Water Quality activities. Thomas Dix (Water Quality Inspector) is the designated coordinator for the Cross Connection Control Program and reports to George. A copy of the 2008 Organizational Chart is attached. City Council 22 — 33 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 14 of 25 2. Operator Certification i 2.1 Distribution System Operator Certification In March of 2001 , the Department notified the City through a letter that the City's water system must be operated by qualified operators as required by Section 64413.3 of the Operator Certification Regulations. The City's water system is classified as a D5 distribution system. The City currently employs the following employees with California Distribution System Operator certification as indicated in Table 10. i Table 10. State Certified Distribution System Operators Name Operator number Grade Expire Date Barrera, Cesar 22920 D4 08/01/10 Burk, Raymond L. 22932 D5 07/01/12 Braswell, DeShannon 30501 D2 10/01/10 Carba'al, David 22926 D3 04/01/12 Castro, Joe M. 22910 D1 12/12 Cox, Michael 22931 D2 05/12 Daskalaskis, Craig 02477 D3 05/01/12 Dix, Thomas 05211 D3 07/31/12 Duarte, Frank 06202 D2 03/01/12 Garcia, Michael 06203 D2 08/01/10 Green, Jonathan 06157 D3 03/01/12 Hernandez, Robert 19301 D2 03/01/12 Hunt, George 01759 D3 03/01/12 Kilgore, Bruce 05480 D3 03/01/12 Lopez, Vincent 22921 D2 05/01/10 Merritt, William 06209 D2 07/01/10 Murrietta, Michael 06210 D2 05/01/11 Nunez, Lorenzo 15070 D2 15/01/12 Phan, John 05025 D4 03/01/12 Rodriguez, Gilbert 22934 D1 12/01/12 Saba, Nabil 05781 D5 01/01/11 Seren ber , Richard 02725 D2 04/01/12 Villasenor, Jose 08818 D2 05/01/12 Villela, Edmundo 22933 D2 03/01/11 Vir en, Jose 05631 D2 01/01/12 Yarbrough, Kenneth 06213 D2 04/01/12 3. Cross Connection Program The program is administered by the City and coordinated with the Orange County Health Department. The City's ordinance is adequate and meets minimum requirements of the cross-connection control regulations. Thomas Dix is the designated Cross Connection Control Program coordinator. i City Council 22 — 34 10/20/2026 Department of Public Health Drinking Water Field Operations Branch I Engineering Report— City of Santa Ana Page 15 of 25 The Orange County Health Department and the City have high hazard priority lists that are similar for those services in the City. The City also has low hazard priority list for premises with low hazard cross-connection potential. The initial surveys have been completed and the City is continuing with their follow-up surveys. The program relies on premise isolation and internal protection to provide for protection from backflow. The water user is responsible for maintaining the devices. The City uses this Department's list of approved devices for new installations that are inspected by the City personnel. A total of 1,332 backflow assemblies are installed at the meter for premise isolation of which 56 assemblies were installed in 2008. Also, a total of 2,983 backflow assemblies are installed on- site for internal protection of which 18 assemblies were installed in 2008. Notices are sent out and replies and testing results are documented. All devices were tested; all devices that failed were repaired or replaced as indicated the Table 12. The City reviews its water system on an annual basis to determine if additional backflow devices need to be installed within its distribution system. Adequate test records and files are maintained on each installed device. Notices are sent out and replies and testing results are documented. The City is in compliance with the cross-connection regulations. 4. Recycle Water Use The City distributes Recycled Water purchased from Orange County Water District to eleven sites within the system. Thomas Dix is the designated Recycled Water Program coordinator. RECYCLED WATER USE SITES RECYCLED SITE ADDRESS Adams Park 2302 S. Rait Street Bomo Koral Park 900 W MacArthur Boulevard Centennial Park Soccer Field 3000-C W. Edinger Avenue Chick Fil-A 3601 S. Bristol Street Chroma Systems (Industrial) 3201 S. Susan Street Chroma Systems (Irrigation) 3201 S. Susan Street Kaiser Permanente 3401 S. Harbor Boulevard McFadden Intermediate School 2001 W. Hemlock Santa Ana River Bicycle Trail 3100 W. Edinger Avenue i ! City Council 22 — 35 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 16 of 25 RECYCLED SITE ADDRESS Segerstrom High School 2300 W. Alton Avenue South Coast Village 3951 S. Bear Street 5. Water Quality Complaint Program The City maintains records of water quality complaints. The City's Customer Service staff receives water quality complaints and forwards them to the water quality staff. The City's water quality staff responds to all complaints within 24 hours, investigates and takes proper actions to resolve the problems. There were a total of six customer complaints in 2008. Of these six complaints, four were pressure related and two were color related. All of these complaints were caused by internal plumbing problems. The City's water quality complaint program is adequate. 6. Disaster Response Plan I The City has a comprehensive Emergency Operation Plan dated December 2004. The Plan discusses procedures during an emergency event, chain of communication, and security response measures. The City's Water Quality Emergency Notification Plan is dated March 2009. 7. Consumer Confidence Report The 2008 Consumer Confidence Report (CCR) was mailed to the City's customers on April 15, 2009. The City also attempted to reach non-bill paying customers. by posting the CCR on the City's website. The City has submitted a copy of the 2008 CCR and a completed CCR Certification Form to the Department on July 7, 2009. 8. Flushing and Valve Maintenance Program The average valve spacing in the principal business district is 580 feet and the residential areas are 630 feet. Large valves (greater than 10-inches in diameter) are exercised biannually and smaller valves are inspected annually. All hydrants and valves were inventoried and entered into a system database. Reportedly, there are approximately 4,825 fire hydrants. The City does have a flushing program. Generally, flushing is conducted in response to consumer complaints. 9. Main Disinfection Program The City's distribution crew performs all leak and minor repair. When required, the City conducts main disinfection in accordance with the AWWA specifications. After disinfection, samples are taken and analyzed for bacteriological quality. The mains are placed back into service only if the bacteriological quality is acceptable. City Council 22 — 36 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report—City of Santa Ana Page 17 of 25 New mains are disinfected by contractors and supervised by a City's certified operator. E. Water Quality and Monitoring Plan 1. Bacteriological Water Quality The City collects 50 routine samples weekly in accordance with the approved Bacteriological Sample Siting Plan dated September 22, 2002 from dedicated sample taps located in locked enclosures. The City does not have a history of Total Coliform contamination in its distribution system. The last Total Coliform Rule (TCR) citation (Citation No.: 04-084) the City received was in February 1993. This citation resulted in the City installing chlorinators at key City well sources. Summary of Bacteriological Analyses is attached. The City is currently reliably complying with the TCR. The Department has approved the City's Groundwater Rule Amendment to the Coliform Monitoring Plan in a letter dated November 30, 2009. 2. Surface Water Treatment Rule (SWTR) In addition to total coliform, the City also analyzes all bacteriological water quality samples for chlorine residual. Results are reported monthly to the Department on the Monthly Summary of Monitoring for Surface Water Treatment Regulations. A review of these reports indicates that the City is in compliance with the California SWTR. 3. General Physical Water Quality The City collects thirteen general physical water quality samples per week from-the distribution system. Parameters included in the general physical analysis are pH, turbidity, threshold odor, and apparent color. Sampling locations for general physical analysis are the same as those for bacteriological analysis. The number of general physical samples meets the required minimum of 25 percent of the number of bacteriological water quality samples. A review of these data reveals that general physical water quality of the water supplied by the water system is acceptable. 4. Lead and Copper Rule The City is a large water system under the Lead and Copper Rule. The City recently submitted triennial reduced monitoring schedule analyses results with 50 required tap sampling locations in 2009. The 90th percentile values have never exceeded the action levels for lead and copper of 15 µg/L and 1,300 µg/L, respectively. The water system is in compliance with the Lead and Copper Rule. The next reduced triennial monitoring is scheduled for June, July, August, or September 2012. City Council 22 — 37 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 18 of 25 5. Stage 1 Disinfectants/Disinfection Byproducts Rule (DBPR) Chlorine residuals are monitored on a weekly basis at the 50 bacteriological sample sites. Total and free chlorine residual are measured using a HACH Pocket Colorimeter when a bacteriological sample is collected. The running annual average of chlorine residual level for 2009 is 0.81 mg/L, below the maximum disinfectant residual level (MRDL) of 4 mg/L. The City collects 16 total trihalomethane (TTHM) and 16 haloacetic acid five (HAA5) samples per quarter in accordance with the Department-approved DBPR Monitoring Plan dated December 4, 2001. The 2008 TTHM and HAA5 running annual averages are 8.2 ppb and 2.9 ppb, respectively. These concentrations are below the MCL of 80 ppb for TTHM and 40 ppb for HAA5. The City is in compliance with the Stage 1 DBPR. 6. Stage 2 DBPR The City has completed monitoring for TTHM and HAA5 according to the IDSE Standard Monitoring Plan approved by the Department on December 28, 2006. The City submitted an IDSE Report to the Department on December 22, 2008. The Department has reviewed the report and provided comments via telephone communication with the City's staff on January 5, 2009. The City submitted a revised IDSE Report to the Department in an email dated January 6, 2009. The Department approved the revised report in the letter to the City dated February 22, 2009. As such, the City has fulfilled the IDSE report requirement of the Stage 2 DBPR. The City is strongly suggested to develop and submit a Stage 2 DBPR Compliance Monitoring Plan to the Department for review and approval no later than October 1, 2011. No later than April 1, 2012, the City must also commence its quarterly Stage 2 DBPR compliance monitoring in accordance with the approved Stage 2 DBPR Compliance Monitoring Plan. 7. Source Monitoring MWDSC performs the source water quality monitoring for the surface water purchased by the City. The City samples all the wells monthly for total coliform and heterotrophic plate count (HPC). OCWD conducts Title 22 Source Monitoring for the City's wells in accordance with a Vulnerability Assessment and Waiver Status provided by the Department for each compliance period. The monitoring program includes sampling for VOCs and SOCs, general physical, general mineral, inorganic chemicals, and radionuclides. A review of the Department's water quality database indicates that the source water quality meets all drinking water standards and that the City is in compliance with the source water quality monitoring requirements. I i City Council 22 — 38 10/20/2026 i Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 19 of 25 III. IMPROVEMENT PROGRAM The City has a capital improvement program (CIP) resulting from the 2007 Water Rate Study. The program proposes budgets for improvement projects during the period of 2007-2017. The capital improvement projects includes main replacement, conversion of chlorination facilities from gaseous chlorine to sodium hypochlorite, well rehabilitation and replacement, booster pump replacement, conversion of pumps from natural gas engines to electric motors. The main and booster pump replacement projects are expanded from 2008 to 2016. The City's 2008 Water Master Plan provides recommendations on capital improvement projects for a longer planning horizon, up to the year of 2027. In addition to projects that are in the City's existing CIP for the period of 2007-2017 the Plan recommends two improvement categories: 1. Existing System Improvements: These are water system improvements that address deficiencies in the existing water distribution system. The improvements include the replacement of 63 miles of pipeline, the addition of three portable backup power generators, and the replacement of two wells. 2. Future System Improvements: These are improvements necessary to meet the projected demand in 2027 with the near-term improvements and existing system improvements in place. The projects include the installation of 4,700 feet of pipelines, and 8,000 feet of SA-2 transmission main. i The Diamond Park Mutual Water Company and the Catalina Street Pump Owners Association (two small water systems) have submitted to the Department a pre- application for State Revolving Fund to design and construct facilities to consolidate with the City of Santa Ana. IV. APPRAISAL OF SANITARY HAZARDS AND SAFEGUARDS The City of Santa Ana Water System is adequately maintained and operated. The City has groundwater and purchased treated surface water sources with adequate capacity to meet peak water demand. All groundwater wells are provided with continuous precautionary disinfection. Purchased treated surface water is obtained from MWDSC, which operates under a valid water supply permit. The domestic water supplied by the City meets all drinking water standards. The City's water quality monitoring program is adequate. All wells, reservoirs, pump stations, and other distribution system appurtenances are routinely maintained through a preventive maintenance program and any need for repairs or replacement is performed immediately. The City has an active cross-connection control program with adequate records. The City maintains an up-to-date Water Quality Monitoring Plan and an Emergency Operation Plan. The Department reviewed the plans and specification for the sodium hypochlorite chlorination facilities and found they are in conformance with the Department's City Council 22 — 39 10/20/2026 Department of Public Health Drinking Water Field Operations Branch i Engineering Report— City of Santa Ana Page 20 of 25 Waterworks Standards. The Department also inspected the chlorination facilities and found they have been adequately installed and tested. V. RECOMMENDATIONS The Department finds that the City is capable of supplying safe, wholesome, and potable water to its customers as described in this engineering report. Therefore, issuance of a domestic water supply permit to the City to continue the operation of the City of Santa Ana Water System is recommended subject to the conditions below: i y Safe Drinking Water Act 1. The City shall comply with all the requirements set forth in the California Safe Drinking Water Act, California Health and Safety Code, and any regulations, standards or orders adopted thereunder. Approved Sources 2. The only sources approved for use are listed in Table 1, Table II, and Table III. Table I — Groundwater Sources Well Name PS Code Status :'Capacity' pm Pump water to, Well 16 3010038-018 Active 1,500 Walnut Reservoir Well 18 3010038-019 Active 2,290 John Garthe Res. Well 20 3010038-021 Active 3,020 West Reservoir Well 21 3010038-022 Active 2,890 West Reservoir Well 24 3010038-025 Active 1,690 John Garthe Res Well 26 3010038-026 Active 1,290 East Station Res Well 27 3010038-027 Active 2,080 Crooke Reservoir Well28 3010038-028 Active 2,760 System Well 29 3010038-029 Active 2,520 Walnut Reservoir Well 30 3010038-030 Active 2,530 West Reservoir Well31 3010038-031 Active 3,020 System Well33 3010038-033 Active 2,240 System Well 34 3010038-034 Active 2,850 Walnut Reservoir Well35 3010038-037 Active 1,510 System Well36 3010038-035 Active 2,200 System Well 37 3010038-038 Active 3,600 John Garthe Res Well38 3010038-039 Active 2,300 System Well39 3010038-061 Active 3,000 System Well40 3010038-073 Active 2,500 System Well41 3010038-074 Active 3,000 System Table II — Surface Water Sources i City Council 22 — 40 10/20/2026 Department of Public Health Drinking Water Field Operations Branch I Engineering Report— City of Santa Ana Page 21 of 25 2007" Capacity Actual Source Location (cfs) Usage PS Code cfs SA-1 Bristol St. and Santiago Creek 10 5.2 3010038-066 SA-2 Bristol St. and First St. 10 5.2 3010038-067 SA-3 Bristol St. and McFadden 15 5.2 3010038-068 SA-4 Bristol St. and Warner Ave. 10 4.9 3010038-069 SA-5 Bristol St. and Alton Ave. 5 4.9 3010038-070 SA-6 Tustin Ave. and Santa Clara 20 7.8 3010038-071 SA-7 Redhill Ave. and Warner Ave. 10 4.9 3010038-072 Table III - Emergency Interconnections with Neighboring Systems Agencies Size, Capacity Location Type in. m - Mesa Consolidated 12 3,600 Outflow Mesa Consolidated 12 1,500 Inflow Mesa Consolidated 12 1,500 Inflow City of Fountain Valley 8 1,600 Inflow City of Orange 8 900 Inflow City of Tustin 8 900 Inflow City of Garden Grove 6 900 Fairview and Huckleberry Outflow Approved Treatment Facilities 3. The only treatment facilities that are approved for the system are those listed in Table IV: Table IV- Treatment Facilities Treatment Facility Treatment Processes Wellhead Chlorination Precautionary chlorination with 0.8 percent sodium hypochlorite solution from onsite generators at all wells. Nitrate Blending Well 16 blending with Wells 29 and 33 at the Walnut Reservoir. Nitrate Blending Wells 18 and 24 blending with Wells 36 and 39, respectively, at the Bristol Reservoir. City Council 22 —41 10/20/2026 Department of Public Health Drinking Water Field Operations Branch Engineering Report—City of Santa Ana Page 22 of 25 Permit Amendment 4. No changes, additions, or modifications shall be made to the sources or treatment facilities outlined in Conditions 2 and 3 unless an amended permit has first been obtained from the Department. Operator Certification 5. All personnel who operate the distribution system of the City of Santa Ana shall be certified in accordance with Section 63770, Title 22 of the California Code of Regulations (CCR). The City of Santa Ana is classified as a D5 water distribution system. Therefore, the Chief and Shift Operator(s) for the distribution facilities shall have, at minimum, D5 and D3 certification, respectively. 6. All personnel who operate the City's treatment facilities shall be certified in accordance with Section 63765, Title 22 of the CCR. The minimum grade requirement for the Chief and Shift operator(s) for the treatment facilities are T3 and T2, respectively. Water Quality 7. All water supplied by the City for domestic purposes shall meet all Maximum Contaminant Levels (MCLs) established by the Department. If the water quality does not comply with the California Drinking Water Standards, treatment shall be provided to meet standards. 8. The City shall ensure that all water quality monitoring is completed in accordance with Title 22, Chapter 15 of CCR and the Department's Vulnerability Assessment and Monitoring Frequency Guidelines. 9. Unless specified by regulations, all water samples for compliance purposes shall be analyzed by a laboratory certified by the Department's Environmental Laboratory Accreditation Program Branch (ELAPB) for each analytical technique. 10. Except for bacteriological analyses and constituents without chemical storet numbers, all water quality monitoring results obtained at a certified laboratory shall be submitted to the Department by Electronic Data Transfer (EDT) using the PS Codes listed in Condition 2. Cross-Connection Control Program 11. The City shall comply with Title 17 of the CCR to prevent the water system and treatment facilities from being contaminated by possible cross-connections. The City shall maintain a program for the protection of the domestic water system against " backflow from premises having dual or unsafe water systems in accordance with Title 17.. All backflow prevention devices shall be tested annually. Treatment Plant Operation and Maintenance City Council 22 — 42 10/9012096 Department of Public Health Drinking Water Field Operations Branch Engineering Report— City of Santa Ana Page 23 of 25 12. All treatment facilities shall ,be operated in accordance with a Department- approved Operation, Monitoring, and Maintenance Plan. 13. All treatment facilities shall be maintained in accordance with the manufacturer's specification. 14. Pursuant to § 64590, Title 22 of the California Code of Regulations (CCR), no chemical or product shall be added to drinking water by the City unless the chemical or product is certified as meeting the specifications of NSF International/American National Standard Institute (NSF/ANSI) 60-2005 (Drinking Water Treatment Chemicals-Health Effects). 15. Pursuant to § 64591, Title 22 of the CCR, the City shall not use any chemical, material, lubricant, or product that may come into contact with the drinking water that has not been tested and certified as meeting the specifications of NSF/ANSI 61-2005 / Addendum 1.0-2005. This includes process media (carbon, sand), protective materials (coatings, linings, liners), joining and sealing products (pipes, tanks, fittings), and mechanical devices used in the production, treatment or distribution of drinking water and treatment/transmission/distribution systems (valves, chlorinators, separation membranes). Annual Report 16. The City shall submit an Annual Report on the status and condition of the domestic water system as directed by the Department. VI. APPENDICES 1. System Map and Hydraulic Profile I 2. Service Area Map 3. System Data Sheets 4. Chlorination Equipment Specification 5. Distribution System & Treatment Facility Classification City Council99 —43 1 n 9n 9n76 Department of Public Health Drinking Water Field Operations Branch ,. -----.---•. MWDSC OC FEEDER � r< m - w ri C) in I y a a Ia �cnm j # Cn T y m m •P �3 � i C FA - , i,Y• k 0) n 'JJ w - CDCD ETNkEl " o m n ...s• �-h (D m o m-0 _ � o n o m m o m CD � � �-(n �O m w y G><O i ri CD t " �w Z;a H O mpmCD m C� z m l x o m a o FOUR PRESSURE REDUCING STATIONS m z m co � N o r2 G� T m v N RH %,mo--M- 0 �m K M mm DJ u,m = C� a o >0 m E �� C �a n a Om mcn C Z�1 GMCn (CD Sc'• .O_-I c w cn z Ct � C) (� F+ • -4 W �+ D CD \° A O o o o� C m C z z . CO (n D O o m (D zA ® 7 M m C/) T z 0 v g c� c� p S v n m 0m m O C. om0 �r, m -ZI O m -<c = z29 z ; z Ci - ��_ • crn D O m m o _ • �0 x rn o (Q 00 mCf)� n � 0 rn < z z y m City Council 22 - 4410/20/2026 I � City of Santa Ana 6065 �' Water System IDS ! 85 75 70 60 Monitoring Plan �L ;i '� 80 en-•,(E December 2008 70 ofIx.K. LrI �I1N - rt IIL � I •-'-' I�. p! �i�r ( �3 'SIB hit it , 60 !� �� � 70 GBI:DE-N DRovE -- 'b --��. 5��r is�11 �L � r+M .J �,.�I..=Jill ,„ c r_ I ,L v 111 iif i11��" '. 1� �� —..lc- �... _— I- )l�'`-� Q�.�.I�. �,� 11 ��yJ --�` � = 1, 75 - .- 75 , 4 _1 z1f G�� �@ i _ ! 10, !� �7�� �]�� ,-' t i9l�� j— it Jc I(i p I'ryr�I I� _ 77r11 (�(r T I �� �_ p.� _ „ 80 ._� l ` � �l - 80 ,sli4wJC�L — ) N I A q ��S�r tY s , _ ;��If._t mil`F��L G;!_ �ti� =u� � m ©1 �I'1+ �G .._.— .. rr r r 85 fr T— Cd J L_II .r° a�]G'�CI �7C C Cis C t tLI1J��-7_i ..��., '�'',. �l._'16.71�C � ^•6F57f C � 71 ❑ dH���4jlt-c!�(II � I711 1'.. �I 1' 1 �}a ]Cil(li`'�(] �-0JJ' f L7f-! E .....•,� xa L.�J I�C=J � f F.e..,.. ��!nA-:xW:�.LI `tiJCI C n�;—� �� �► J � '� i,1 �� ,I � �_��-i�... � —r�c� ass--• �cs — �� ��� ij' J;iL1l' (ems ! �] I lalp �r t ti ! �tJ_ I T � !!, ._. ,. � � �.. 5• -> III I l{3fl I r � 90 -u1�e1�, �� �7�fIIfD�� i r t1 6 ` Clf➢fi]�CC)Orlr>J P. ; a'iIE c�� -1�j ��" IAN )w _�, I w.n, �r.:�;. � . `, ate. QJ L� nn(I_a 65 I l Sul .�. l -au t r_ �C_JI (U[� ( (� ii G I I l�CJ'l�R: Ali•, p `�it�1�Ili� 11C_�� `�L.1C�]fi I �iJ�C) °�"�� IL L ggfv/j.�- � J) i�7 ' L I L I I — 11 lr�.E, I�II� '1Oi�iJl �Q I r� I��,•�`�i�lr I ..__ �7 �� ��f, �i 1 IJ FcrwrrAln val.I.E•r '.J"-'. I - ,., Jt 101JUCuTi'uL1I�LlL1u'1JUi.,Jl �L !'u j ��fliQ70 f 4���� rIL l I TUSTna 75 85 � i.�I� _ 5_'�L - ./n;S ,�' �' .c. �.. '��fuli���5h-� (if,l!•,' ��I li��«uI - ��7�a_,F_, ,. II w 90 80 Legend •�'� h".:,, .•_i °w _..JL.I_ 1 te. Praesure Gradient ue°e - = �� �. r '`�• Ila•���- � � Imo• ___ Q Reservoir Site Shmp StMlan rl ....� _J �'JQ�.Jt�l ��j::l I��;"�`-r .��/��`�� �• !/ •1� / • 85 a Wall -� '—.--.J- =r 1 I r MWDCannacllan 95 r��r ? rrT.. l 90 MW D Connection ,I, 0 L, 1 V-,ts -� l�-...I o t�li��°11�. z lI - • �. • IDSE Standard Monllodlg Site l BACTI SamPla Sbdon COST.,IJ"A f' 95 E.nB St. 7 Sampplle Stnllon THMmd HAA5 Proposed S Vg.o J.1 Compllana Manaodrg Stedan ._ �R1:�am 1008.nllnannane:.e. City Council 22 — 45 10/20/2026 ' I i State of California Department of Health Services Drinking Water Field Operations Branch Reservoir Data Santa Ana District System Name: City Of Santa Ana No: 3010038 Source of Information: System Files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name Elevated Tank Walnut Reservoir Date Constructed 1928 1957 _i Purpose (storage, sand trap, etc.) Balancing Storage Capacity 1.0 MG 7.0 MG Location Specific Location Neighborhood Residential Residential Size of Lot 150 feet by 100 feet 300 feet by 350 feet Fencing Chain &Block Wall Chain fence Construction Material Sides Steel Reinforced cement concrete Floor Steel Reinforced cement concrete Cover or Roof Steel Reinforced cement concrete Height Top of Walls Above Ground 140 feet Below Ground Surface Drainage to Reservoir Possible? No No Ventilation Yes Yes Screening Yes Yes Inlet and Outlet Arrangement Inlet - Location Through bottom NW corner Distance Above Bottom 18 inches 7 feet Outlet -Distance From Inlet Common 30 feet Distance Above Bottom -- 3 feet above floor Drain to Where Storm Drain Storm Drain Overflow to Where Storm Drain Storm Drain Sewer or Other Hazardous Connections None None (If so where?) Relation to System Receives From System Wells 13,16,29 and 33 Delivers To System System Defects and Remarks (Include statements on cleaning practices, condition of structure--particularly of roof, Very rusty (tank and Nitrate Blending Site, dimensions and shape of reservoir, leakage, kind roof). Sand Trap and location of access openings,protection against insects,birds,and rodents.) i i City Council 22 — 46 10/20/2026 i I i State of California Department of Health Services Drinking Water Field Operations Branch Reservoir Data Santa Ana District I I System Name: City Of Santa Ana No: 3010038 Source of Information: System Files, City of Santa Ana ' Collected By: Bruce Berger Date: January 2009 I Number or Name West Reservoir East Station Reservoir Date Constructed 1963 1969 Purpose (storage, sand trap, etc.) Storage Storage i Capacity 6.0 MG 6.0 MG Location Specific Location Neighborhood Residential Industrial Size of Lot 300 feet by 204 feet 300 feet by 300 feet Fencing Chain link fence Chain link fence Construction Material Sides Steel Steel Floor Steel Steel Cover or Roof Steel Steel Height Top of Walls Above Ground 32 feet 32 feet Surface Drainage to Reservoir Possible? No No Ventilation Yes Yes Screening Yes Yes Inlet and Outlet Arrangement Inlet - Location SE section of the tank NW side Distance Above Bottom 30 inches 1.5 feet Outlet -Distance From Inlet 160 feet 115 feet Distance Above Bottom 6 inches 6 inches Drain to Where Storm Drain Storm Drain Overflow to Where Storm Drain Storm Drain Sewer or Other Hazardous Connections None None (If so where?) Relation to System Receives From Wells 20, 21 and 30 Well 26 Delivers To System System Defects and Remarks (Include statements on cleaning practices, condition of structure--particularly of roof, dimensions and shape of reservoir, leakage,kind and location of access openings,protection against insects,birds,and rodents.) i I � I City Council 22 —47 10/20/2026 I I State of California Department of Health Services Drinking Water Field Operations Branch Reservoir Data Santa Ana District System Name: City Of Santa Ana No: 3010038 Source of Information: System Files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name Cambridge Reservoir Crooke Reservoir Date Constructed 1928 1979 Purpose (storage, sand trap, etc.) Balancing Storage Capacity 1.3 MG 6.0 MG Location Specific Location Neighborhood Residential Residential Size of Lot 150 feet by 100 feet 1.7 acres Fencing Chain&Block Wall Chain fence Construction Material Sides Steel Reinforced cement concrete Floor Steel Reinforced cement concrete Cover or Roof Steel Reinforced cement concrete Height Top of Walls Above Ground 140 feet 20 feet Surface Drainage to Reservoir Possible? No No Ventilation Yes Yes Screening Yes Yes i Inlet and Outlet Arrangement Inlet - Location Through bottom West side Distance Above Bottom 18 inches 22 feet Outlet-Distance From Inlet Common 75 feet from west inlet& 236 feet from south inlet Distance Above Bottom -- 28 inches above floor Drain to Where Storm Drain Storm Drain Overflow to Where Storm Drain Storm Drain Sewer or Other Hazardous Connections None None (If so where?) Relation to System Receives From Well 22 Well 27 Delivers To System System Defects and Remarks (Include statements on cleaning practices, condition of structure--particularly of roof, dimensions and shape of reservoir, leakage, kind and location of access openings,protection against insects,birds,and rodents.) City Council 22 — 48 10/20/2026 State of California Department of Health Services Drinking Water Field Operations Branch Reservoir Data Santa Ana District System Name: City Of Santa Ana No: 3010038 Source of Information: System Files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name South Reservoir John Garthe (Bristol) (North side) Reservoir Date Constructed 1966 1994 Purpose (storage, sand trap, etc.) Storage,balancing Storage Capacity 6.0 MG 6.0 MG Location Specific Location Neighborhood Industrial Residential Size of Lot 340 feet by 640 feet 5 acres Fencing Chain link fence Chain link &Block wall Construction Material Sides Prestressed Concrete Reinforced Concrete Floor Prestressed Concrete Reinforced Concrete_ Cover or Roof Prestressed Concrete Reinforced Concrete Height Top of Walls Above Ground 16 feet 15 feet Surface Drainage to Reservoir Possible? No No Ventilation Yes, two vents Yes Screening Yes Yes Inlet and Outlet Arrangement Inlet - Location South west side Distance Above Bottom 6 inches Outlet -Distance From Inlet Common Distance Above Bottom -- Drain to Where OCFCD Channel Creek Overflow to Where OCFCD Channel Creek Sewer or Other Hazardous Connections None None (If so where?) Relation to System Receives From System Wells 18, 24 and 36 Delivers To System System Defects and Remarks (Include statements on cleaning practices, condition of structure--particularly of roof, Nitrate Blending Site dimensions and shape of reservoir, leakage,kind and location of access openings,protection against insects,birds,and rodents.) City Council 22 —49 10/20/2026 State of California Department of Health Services Drinking Water Field Operations Branch Reservoir Data Santa Ana District System Name: City Of Santa Ana No: 3010038 Source of Information: System Files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name New North Reservoir New South Reservoir (Bristol Site) (Bristol Site) Date Constructed 2002 2002 Purpose (storage, sand trap, etc.) Storage Storage Capacity 5.0 MG 5.0 MG Location Specific Location Neighborhood Residential Residential Size of Lot 5 acres 5 acres Fencing Chain link &Block wall Chain link & Block wall Construction Material Sides Reinforced Concrete Reinforced Concrete Floor Reinforced Concrete Reinforced Concrete Cover or Roof Reinforced Concrete Reinforced Concrete Height Top of Walls Above Ground ?? feet ?? feet Surface Drainage to Reservoir Possible? No No Ventilation Yes Yes Screening Yes Yes Inlet and Outlet Arrangement Inlet - Location Distance Above Bottom Outlet -Distance From Inlet Distance Above Bottom Drain to Where Overflow to Where Sewer or Other Hazardous Connections (If so where?) Relation to System Receives From Delivers To Defects and Remarks (Include statements on cleaning practices, condition of structure--particularly of roof, dimensions and shape of reservoir, leakage,kind and location of access openings,protection against insects,birds,and rodents.) City Council 22 — 50 10/20/2026 State of California Department of Health Services Drinking Water Field Operations Branch Pumping Station Data. Santa Ana District System Name: City of Santa Ana No: 3010038 Source of Information: System files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name : John Garthe Reservoir West Reservoir Pump Station Pump Station Date Constructed: 1994 1963 Purpose: Boosting pressure Boosting pressure Location : Housing : Concrete Concrete Insulation: None None Heating: None None Pit Depth (if any): None 6 feet Drainage Good Storm drain Relation to System : Receives From: John Garthe Reservoir West Reservoir Delivers To: System System Inlet Pressure: 60 psi Reservoir Level Outlet Pressure: 68 psi 84 psi Maximum Capacity (gpm): 20,750 . 13,140 Flood Hazard : None None Pumping Units : Make: Peerless Vertiline Type: Vertical turbine Vertical turbine No. 1 @ 2,060, No. 1 @ 2,290, Nos. 2 & 3 @ 3,050, No. 2 @ 2,240, Capacity (gpm): No. 4 @ 4,170, No. 3 @2,330, No. 5 @ 4,840, & No. 4 @4,030 & No. 6 (Natural gas) @ 3,580. No. 5 @ 2,250. Lubrication: Water(Oil for natural gas Engine) Water Power: Electric Electric Auxiliary Power: Natural Gas (46) None Control: Auto Auto Frequency of Use: Daily Daily Defects and Remarks : City Council 22 — 51 10/20/2026 State of California Department of Health Services Drinking Water Field Operations Branch Pumping Station Data Santa Ana District System Name: City of Santa Ana No: 3010038 Source of Information: System files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 i i Walnut Reservoir Cambridge Reservoir Number or Name : Pump Station Pump Station Date Constructed: 1957 1965 Purpose: Boosting Pressure Boosting pressure Location : Housing : Concrete None Insulation: None N/A Heating: None N/A Pit Depth (f any): 15 feet N/A Drainage Good N/A Relation to System : Receives From: Walnut Reservoir Cambridge Reservoir Delivers To: System System Inlet Pressure: Reservoir Level Reservoir level Outlet Pressure: 65-70 psi 60-65 psi Maximum Capacity (gpm): 14,780 4,390 Flood Hazard : None None Pumping Units : Make: General Electric Worthington Type: Induction Motor Vertical turbine No. 1 @ 3,540, No. 2 @ 3,490, No. 1 @ 1,480, Capacity (gpm): No. 3 @ 3,450, No. 2 @ 1,430, & No. 4 @ 2,550 & No. 3 @ 1,480. No. 5 @ 1,750. Lubrication: Oil Power: Electric Electric Auxiliary Power: None None Control: Auto Auto Frequency of Use: Daily Daily 1 Defects and Remarks : (Surge tank at site) i City Council 22 — 52 10/20/2026 I State of California Department of Health Services Drinking Water Field Operations Branch pU111�J111g Station Data Santa Ana District System Name: City of Santa Ana No: 3010038 Source of Information: System files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name : Crooke Reservoir East Station Reservoir Pump Station Pump Station Date Constructed: 1978 1969 Purpose: Boosting pressure Boosting pressure Location : Housing : Concrete None Insulation: A/C N/A Heating: None N/A Pit Depth (if any): None N/A Drainage To creek N/A Relation to System : Receives From: Crooke Reservoir East Station Reservoir Delivers To: System System Inlet Pressure: Reservoir Level Reservoir Level Outlet Pressure: 75-80 psi 75-80 psi Maximum Capacity (gpm): 8,910 4,970 Flood Hazard : None None Pumping Units : Make: Aurora Vertiline U.S. Type: Vertical turbine Vertical Turbine No. 1 @ 2,910, No. 1 @ 2,420, & Capacity (gpm): No. 2 @ 3,090, & No. 3 2,910. No. 2 @ 2,550. Lubrication: Water Water Power: Electric Electric Auxiliary Power: None None Control: System Pressure System Pressure Frequency of Use: Daily Daily Defects and Remarks : City Council 22 - 53 10/20/2026 i i State of California Department of Health Services Drinking Water Field Operations Branch Pumping Station Data Santa Ana District System Name: City of Santa Ana No: 3010038 Source of Information: System files, City of Santa Ana Collected By: Bruce Berger Date: January 2009 Number or Name : South Reservoir Pump Station Date Constructed: 1966 Purpose: Boosting pressure Location : Housing : Block Wall Insulation: No Heating: No Pit Depth (if any): No Drainage Catch basin to storm drain Relation to System : Receives From: South Reservoir Delivers To: System Inlet Pressure: Reservoir Level Outlet Pressure: 89-90 psi Maximum Capacity (gpm): 4,040 Flood Hazard : None Pumping Units : Make: Type: Capacity (gpm): No. 1 & 2 @ 2,020 (Standby) Lubrication: Water Power: Electric Auxiliary Power: None Control: System Pressure Frequency of Use: Daily Defects and Remarks : Has two altitude valves & a PRV. Station is now not in use City Council 22 — 54 10/20/2026 WELL DATA SHEET (Page 1 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database' System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 16 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-121-03 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-121-03 Well Status (Active, Standby, Inactive) Active from DHS database' WELL LOCATION Latitude 121500.766 from DHS database Longitude 424358.0010 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 110 Street Address 1011 W. 6th St. Nearest Cross Street 6th St. & Flower St. City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin I Main Basin Ito come from.DWR:. SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 1,902 Distance to Abandoned Wells (ft) 498 Distance to Surface Water(ft) **Size of controlled area around well (square feet) 480 *Type of access control to well site (fencing, building, etc) walls • Surface Seal? (Concrete slab)("YES", "NO"or"UNKNOWN") YES * Dimensions of concrete slab: Len th ft/Width(ft)/Thick in 4/4/6 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") NO Run off:onl ENCLOSURE/HOUSING Enclosure Type (building, vault, none; etc.) walls Floor material black top Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 1/1/1932 Drilling Method Cable Tool Depth of Bore Hole feet below ground surface 978 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-305; 305-542; 542-978 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 20; 20; 16 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 55 10/20/2026 WellData/W16 6/9/2010 WELL DATA SHEET (Page 2 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in jActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) j Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 305 Screened Interval Beginning Depth/Ending Depth (ft below surface); 305-325; 353-384; 712- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 721; 920-950 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 90 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) NO * Depth of Annular Seal (ft) Material of Annular Seal (cement grout, bentonite, etc.) - Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? "YES", "NO"or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 122 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 187 Pumping water level measurement: Date/Method 10/31/2001 WELL PRODUCTION i Well Yield (gpm) 1,290 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? "YES" or"NO" YES Production (gallons per year) 203,102,928 Frequency of Use (hours/year) 2,354 Typical pumping duration (hours/day) 6.5 PUMP Make Goulds Type Vertical Turbine Size (hp) 125 * Capacity (gpm) 1,500 Depth to suction intake ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") NO Runoff only Discharges to: (i.e., distribution system, storage, etc.) Walnut Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 56 10/20/2026 WellData/W16 6/9/2010 WELL DATA SHEET wage 3 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A_if not applicable. '"Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination . Rural, Re=Residential,Co=Commercial, at the reservoir. =Industrial, Mu=Municipal, P=Pristine, 0=Other 2. Conductor Casing-Oversized casing used to stabilize borehole during well j-Sampling taps are construction. Should be removed during installation of annular seal` Ilocated at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called sanitary seal". City Council 22 — 57 10/20/2026 WellData/W16 6/9/2010 WELL DATA SHEET (Page 4 of 3 j Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database: Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 j WELL IDENTIFICATION j *Well Number or Name Well No: 18 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-01 E02 S DWR Well Log on File? ("YES" or"NO") —' State Well Number(from DWR) 05S/10W-01E02 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121568.508 from DHS database' Longitude 424375.312 from DHS database. Ground Surface Elevation (ft above Mean Sea Level) 123 Street Address 2401 N. Bristol St. Nearest Cross Street Bristol St. & Creek City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin 1to come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR ': SANITARY CONDITIONS I ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimate Distance to Active Wells (ft) 455 Distance to Abandoned Wells (ft) 454 I . Distance to Surface Water(ft) ** Size of controlled area around well (square feet) *Type of access control to well site (fencing, building, etc) walls *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES *Dimensions of concrete slab: Length(ft)/Width ft /Thick(in) 4/4/12 *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES"or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) walls Floor material black top Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION i Date drilled 4/30/1956 Drilling Method Cable Tool Depth of Bore Hole (feet below ground surface) 654 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-623; 623-654 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel i City Council 22 — 58 10/20/2026 WellData/W18 6/9/2010 WELL DATA SHEET (Page 5 of 3 Complete as much information as possible. Leave blank if information_is not available,_ _u_se N.A. if not applicable.--- Indicates items required for Source Water Assessment 1 i _ **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 245 Screened Interval Beginning Depth/Ending Depth (ft below surface); 415; 523-526; 584-590; 2nd Screened Interval Beg. Depth/Ending Depth.; 3rd Screened Interval, etc. 596-623 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 141 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) UNKNOWN * Depth of Annular Seal (ft) - Material of Annular Seal cement grout, bentonite, etc.) - Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts,-clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default *Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") NO Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 124 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 187 Pumping water level measurement: Date/Method 10/30/2001 WELL PRODUCTION Well Yield (gpm) 1,704 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? "YES" or"NO") YES Production (gallons per year) 495,554,201 Frequency of Use (hours/year) 1,932 Typical pumping duration (hours/day) 6 PUMP Make Goulds Type Vertical Turbine Size (h 150 *Capacity (gpm) 2,000 Depth to suction intake (ft below ground surface Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) Garthe Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 59 10/20/2026 Wel]Data/W1 S 6/9/2010 WELL DATA SHEET (Pacie 6 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A.if not applicable_ *Indicates Items required for Source Water Assessment _ �� **Indicates additional items required for assessments and Ground Water Rule NOTES I (I 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru = -Continuous chlorination is I Rural, Re=Residential, Co=Commercial, .provided. I =Industrial, Mu=Municipal, P=Pristine, O=Other —_ 2.Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. _- _ located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal". I I i City Council 22 — 60 10/20/2026 WellData/W18 6/9/2010 WELL DATA SHEET (Page 7 of 3 i Complete as much information as possible. Leave blank if information is not available, use N.A.-if not applicable.-.. _-- *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule j (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION j System Name City of Santa Ana from DHS database System Number 3010038 from DHS.database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 20 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-16B03 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-16B03 S - Well Status (Active, Standby, Inactive) Active 1from DHS database WELL LOCATION Latitude 121476.023 from DHS database Longitude 424533.188 from DHS database'.: Ground Surface Elevation (ft above Mean Sea Level) 67 Street Address 4426 W. 1 st St. Nearest Cross Street 1 st St. & Newhope St. City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file?_("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin t6come from DWR DWR Ground Water Sub-basin Main Basin to come from DWR-` SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 494 Distance to Abandoned Wells (ft) 608 Distance to Surface Water (ft) ** Size of controlled area around well (square feet) 120,000 Estimated *Type of access control to well site (fencing, building, etc) fencing *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick in 4/4/14 Estimated *Within 100 year flood plain? ("YES", "NO"or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) fence Floor material black top Located in Pit? "YES" or"NO" NO .Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 9/11/1962 Drilling Method Direct Rotary Depth of Bore Hole (feet below ground surface) 981 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-120; 120-940; 940-972 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 32; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 61 10/20/2026 WellData/W20 6/9/2010 i WELL DATA SHEET (Page 8 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. ------ *Indicates items required for Source_Water Assessment _C "Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 390 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 390-940 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 550 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 120 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to to ft below ground surface) Total length of gravel pack(ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply: sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default= 0.2) (or"UNKNOWN') UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN') YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 98 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 122 Pumping water level measurement: Date/Method 11/19/2001 WELL PRODUCTION Well Yield (gpm) 3,452 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production gallons per year) 826,455,891 Frequency of Use (hours/year) 5,862 Typical pumping duration (hours/day) 18 PUMP Make Goulds Type Vertical Turbine Size (hp) 150 * Capacity (gpm) 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") NO Run off only Discharges to: (i.e., distribution system, storage, etc.) West Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 62 10/20/2026 i WellData/W20 6/9/2010 WELL DATA SHEET(Page 9 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. .f not applicable. *Indicates items required for Source Water Assessment **Indicates additional items re uired for assessments and Ground Water Rule NOTES _ 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re=Residential, Co=Commercial, provided at reservoir. I=Industrial, Mu=Municipal, P=Pristine,_0=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal"_ _— -Well light indicator was _ Inot working. --- - -- - - -Stagnant water in the -------------------- -- --._...-- -- ---- ------- overflow vault must be --- --- - drained or pumped. i City Council 22 — 63 10/20/2026 Wel[Data/W20 6/9/2010 WELL DATA SHEET (Page 10 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated i field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 21 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-16B02 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-16B02 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121481.641 from.DHS database Longitude 424532.812 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 68 Street Address 4304 W. 1 st St. Nearest Cross Street 1st St. & Newhope St. City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 9) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES i DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin I Main Basin Ito come from DWR, SANITARY CONDITIONS j **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 494 Distance to Abandoned Wells (ft) 395 Distance to Surface Water(ft) **Size of controlled area around well (square feet) 2,600 *Type of access control to well site (fencing, building, etc) walls *Surface Seal? (Concrete slab)("YES", "NO"or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 4/4/9 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) walls Floor material gravel Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION j Date drilled 9/25/1962 Drilling Method Direct Rotary Depth of Bore Hole (feet below ground surface) 986 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-127; 127-400;400-960 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 32; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 64 10/20/2026 WellData/W21 6/9/2010 I WELL DATA SHEET (Page 11 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable_— . _ . _. . .. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or,Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 400 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 400-960 * Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 560 _ *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 127 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN') UNKNOWN default * Confining layer (Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 99 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 121 Pumping water level measurement: Date/Method 11/19/2001 WELL PRODUCTION Well Yield (gpm) 3,060 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 873,639,116 Frequency of Use (hours/year) 3,413 Typical pumping duration (hours/day) 10 PUMP Make Vertiline Type Vertical Turbine Size (hp) 150 *Capacity (gpm 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") NO lRuh off only Discharges to: (i.e., distribution system, storage, etc.) West Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 65 10/20/2026 WellData/W21 6/9/2010 WELL DATA SHEET (Pa- a 12 of 3 Complete as much information as possible, Leave blank if information is not available, u_seN.A_.if not applicable._ *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru = -Continuous chlorination is Rural, Re=Residential,Cc=Commercial, provided. I = Industrial, Mu=Municipal, P=Pristine,O=Other 2, Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction, Should be removed during installation of annular seal, located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. City Council 22 — 66 10/20/2026 WellData/W21 6/9/2010 I WELL DATA SHEET (Page 13 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source WaterAssessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION j System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (welllog, DHS/County,files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 7/14/2004 WELL IDENTIFICATION *Well Number or Name Well No. 22 from DHS database * DHS Source Identification Number FRDS ID No.) 023 DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 04S/09W-32P01 S Well Status (Active, Standby, Inactive) Abandoned from DHS database WELL LOCATION Latitude 121592.094 from DHS database Longitude 424238.188 from.DHS database Ground Surface Elevation (ft above Mean Sea Level) 203 Street Address 2736 N. Cambridge Ave Nearest Cross Street Garden Grove Freeway City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin Main Basin to come from DWR SANITARY CONDITIONS "*Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) Distance to Active Wells (ft) 143 Distance to Abandoned Wells (ft) 729 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) *Type of access control to well site (fencing, building, etc) * Surface Seal? (Concrete slab)("YES", "NO"or"UNKNOWN") * Dimensions of concrete slab: Len th(ft)/Width(ft)/Thick in *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) Floor material Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 5/21/1963 Drilling Method Direct Rotary Depth of Bore Hole feet below ground surface) 1,202 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-94; 94-1200; 1200-1202 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 30; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 67 10/20/2026 WellData/Well 22 Abandoned 6/9/2010 WELL DATA SHEET (Page 14 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable_ *Indicates items required for Source Water Assessment_ **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) j Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 510 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 510-1200 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 690 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 94 Material of Annular Seal (cement grout, bentonite, etc. Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack ft AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 214 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 292 Pumping water level measurement: Date/Method 7/26/1996 WELL PRODUCTION Well Yield (gpm) 1,670 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 10/25/1995 Is the well metered? "YES" or"NO") YES i Production(gallons per year) Frequency of Use (hours/year) Typical pumping duration (hours/day) PUMP j Make Type Size (hp) *Capacity (gpm) Depth to suction intake (ft below ground surface) Lubrication Type Type of Power: (i.e., electric, diesel, etc.) Auxiliary power available? ("YES"or"NO") Operation controlled by: (i.e., level in tank, pressure, etc. Pump to Waste capability? ("YES" or"NO") Discharges to: (i.e., distribution system, storage, etc.) REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 68 10/20/2026 WellData/Well 22 Abandoned 6/9/2010 WELL DATA SHEET (Page 15 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. Indicates items required for Source Water Assessment *`Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area (list all that apply):A=Agricultural, Ru = -Abandoned Well. Rural, Re= Residential, Co= Commercial, 7/14/04 I = Industrial, Mu=Municipal, P= Pristine, 0=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Phyically disconnected construction. Should be removed during installation of annular seal. _from distribution system. 3.Annular Seal-Seal of grout in the space between the well casing and the wall! of the drilled hole. Sometimes called"sanitary seal'. j I City Council 22 — 69 10/20/2026 WellData/Well 22 Abandoned 6/9/2010 WELL DATA SHEET (Page 16 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. " Indicates items required for Source Water Assessment_ **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in jActual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION j j System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 24 from DHS database. * DHS Source Identification Number(FRDS ID No.) 05S/10W-02K02 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-02K02 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION i Latitude 121562.875 from DHS.database Longitude 424409.906 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 108 Street Address 1800 W. 22nd St. Nearest Cross Street 22nd St. &Avalon St. City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR .' DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS j ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 543 Distance to Abandoned Wells (ft) 360 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 602 *Type of access control to well site (fencing, building, etc) fencing * Surface Seal? (Concrete slab)("YES", "NO"or"UNKNOWN") YES * Dimensions of concrete slab: Len th(ft)/Width(ft)/Thick in 5/5/9 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN') NO * Drainage away from well? ("YES" or"NO") YES ENCLOSUREIHOUSING Enclosure Type (building, vault, none, etc.) fencing Floor material gravel Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION j Date drilled 5/3/1965 Drilling Method Cable Tool Depth of Bore Hole (feet below ground surface) 688 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-654; 654-682 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel City Council 22 — 70 10/20/2026 WellData/W24 6/9/2010 WELL DATA SHEET (Page 17 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. i *Indicates items required for Source Water-Assessment.- Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO"or"UNKNOWN") * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 352 Screened Interval Beginning Depth/Ending Depth (ft below surface); 352-375; 578-596; 606- 2nd Screened Interval Beg. Depth/Ending,Depth; 3rd Screened Interval, etc. 645; 650-654 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 84 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) UNKNOWN * Depth of Annular Seal (ft) - Material of Annular Seal (cement grout, bentonite, etc.) - Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN') UNKNOWN default *Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN') YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 117 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 263 Pumping water level measurement: Date/Method 10/30/2001 WELL PRODUCTION Well Yield (gpm) 1,620 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 131,285,368 Frequency of Use (hours/year) 1,078 Typical pumping duration (hours/day) 3 PUMP Make Vertiline Type Vertical Turbine Size (hp) 150 *Capacity (gpm) 1,800 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) Garthe Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 71 10/20/2026 WellData/W24 6/9/2010 i WELL DATA SHEET (Page 18 of 3 Complete as much information as possible. Leave blank if information is not available, use_N.A. if-not applicable. *Indicates items required for Source Water Assessment _ _ _ �_ _ **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Off line for maintenance Rural, Re= Residential,Co=Commercial, (vibration). 7/14/04 I=Industrial, Mu= Municipal, P=Pristine, 0=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall; of the drilled hole. Sometimes called"sanitary seal'. I City Council 22 — 72 10/20/2026 WeliData/W24 6l9/2010 WELL DATA SHEET (page 19 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. -- --.--I-----'---- --- - - - - . - - *Indicates items required for Source Wafer Assessment _ _] _ "*Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other DHS Date Information Collected/Updated. 1/27/2009 WELL IDENTIFICATION i *Well Number or Name Well No. 26 from DHS database * DHS Source Identification Number (FRDS ID No.) 05S/09W-19H01 S DWR Well Log on File? ("YES" or"NO") -� State Well Number(from DWR) 05S/09W-19H01 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121406.664 from DHS database Longitude 424272.188 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 76 Street Address 1730 S. Santa Fe Nearest Cross Street Santa Fe & Edinger City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to`come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 4,499 Distance to Abandoned Wells (ft) 697 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) *Type of access control to well site (fencing, building, etc) fencing *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 414/10 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES"or"NO") YES ENCLOSURE/HOUSING Enclosure Type building, vault, none, etc.) fencing Floor material black top Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 11/29/1.967 Drilling Method Reverse Rotary Depth of Bore Hole feet below ground surface 1,186 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-96; 96-1140; 1140-1152 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 1 36; 18; 18 Casing Material; 2nd Casing Material; 3r1 Casing, etc. Steel; Steel; Steel City Council 22 — 73 10/20/2026 WellData/W26 6/9/2010 WELL DATA SHEET (Page 20 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) i Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 330 Screened Interval Beginning Depth/Ending Depth (ft below surface); 890-940; 970-1010; 1110- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 1140 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 546 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 96 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 0 Total length of gravel pack (ft) 1186 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") - YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 117 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 168 Pumping water level measurement: Date/Method 11/28/2001 WELL PRODUCTION I Well Yield (gpm) 1,896 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 596,861,277 Frequency of Use (hours/year) 4,320 Typical pumping duration (hours/day) 12 PUMP Make Vertiline Type Vertical Turbine Size (hp) 150 * Capacity (gpm) 2,050 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary ower available? "YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) t level Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) East Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 74 10/20/2026 WellData/W26 6/9/2010 WELL DATA SHEET(Page 2 of3 Complete as much information as possible. Leave blank if information is not available, use N.A.. if not applicable. *Indicates items required for Source Water Assessment T __ -;—*Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re=Residential,Co=Commercial, provided. I =Industrial, Mu=M_ unicipal, P=Pristine, O=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are I construction. Should be removed during installation of annular seal. located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called "sanitary seal'. City Council 22 — 75 10/20/2026 WellData/W26 6/9/2010 WELL DATA SHEET (Page 22 of 3 Complete as much information as possible: Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment *"Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION i i System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 27 from DHS database * DHS Source Identification Number(FRDS ID No.) 04S/09W-31 Q01 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 04S/09W-31 Q01 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121591.445 from DHS database Longitude 424287.500 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 163 Street Address 730 E. Memory Lane Nearest Cross Street Memory Lane & Creek City Santa Ana County Orange " Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells(ft) 440 Distance to Abandoned Wells (ft) 1,252 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 555 *Type of access control to well site (fencing, building, etc) building * Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width ft /Thick(in) 4/414 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 4/1/1976 Drilling Method Cable Tool Depth of Bore Hole feet below ground surface) 1,152 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-1152 Casing Diameter (inches); 2nd Casing Diameter; 3rd Casing, etc. 16 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel I City Council 22— 76 10/20/2026 WellData/W27 6/9/2010 i I WELL DATA SHEET (Page 23 of 3 Complete as much information as possible. Leave blank if information is not available, use N_.A. if not applicable. *Indicates items required for Source WaterAssessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in jActual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") - * Depth to highest perforations/screens (ft below surface) (or I "UNKNOWN") 396 396-480;528-612;708-732;816- Screened Interval Beginning Depth/Ending Depth (ft below surface); 840;888-912;960-984; 1032- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 1140 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 372 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 100 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply: sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata)above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 174 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 295 Pumping water level measurement: Date/Method 11/28/2001 WELL PRODUCTION Well Yield (gpm) 2,865 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 866,177,128 Frequency of Use (hours/year) 3,344 Typical pumping duration (hours/day) 10 PUMP Make Vertiline Type Vertical Turbine Size (hp) 300 *Capacity (gpm) 2,700 Depth to suction intake (ft below ground surface) Lubrication Type Water Tye of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) Crooke Reservoir REMARKS AND DEFECTS (use additional sheets as necessary)_ City Council 22 — 77 10/20/2026 WellData/W27 6/9/2010 I WELL DATA SHEET (Page 24 of 3 Complete as much information as possible. Leave blank if information is not available,_ _u_se N.A.. if not applicable. *Indicates items required for Source Water Assessment j **Indicates additional items required for assessments and Ground Water Rule 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru = -Continuous chlorination s Rural, Re= Residential, Co=Commercial, provided. I =Industrial, Mu=Municipal, P=Pristine, O= Other 2. Conductor Casing -Oversized casing used to stabilize bore hole during well Sampling taps are construction. Should be removed during installation of annular seal, located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called "sanitary seal'. City Council 22 — 78 10/20/2026 WellData/W27 6/9/2010 WELL DATA SHEET (Page 25 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database ' System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS ' Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION i *Well Number or Name Well No. 28 from DHS database * DHS Source Identification Number(FRDS ID No.) 04S/09W-31 R01 S DWR Well Log on File? ("YES" or"NO") — State Well Number(from DWR) 04S/09W-31 R01 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION i Latitude 121594.797 from DHS database Longitude 424281.312 from DHS database' Ground Surface Elevation (ft above Mean Sea Level) 166.5 Street Address 730 E. Memory Lane Nearest Cross Street Memory Lane & Creek City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin Main Basin Ito come from,DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 440 Distance to Abandoned Wells (ft) 1,175 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 555 *Type of access control to well site (fencing, building, etc) building *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab; Length(ft)/Width(ft)/Thick(in) 4/4/4 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 3/17/1976 Drilling Method Cable Tool Depth of Bore Hole (feet below ground surface) 1,200 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-990 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel City Council 22 — 79 10/20/2026 WellData/W28 6/9/2010 WELL DATA SHEET (Page 26 of 3 Complete as much information as possible. Leave blank if information is not available,_ use N.A, if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 250 Screened Interval Beginning Depth/Ending Depth (ft below surface); - 5 ; 5 - 5 - 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 790; 810-850; 890-980 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 550 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES -� * Depth of Annular Seal (ft) 100 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default=0,2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO"or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 165 Static water level measurement: Date/Method 11/27/2001 Pumping water level ft below ground surface 257 Pumping water level measurement: Date/Method 10/30/2001 WELL PRODUCTION Well Yield (gpm) 2,404 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production gallons per year) 417,154,450 Frequency of Use (hours/year) 3,412 Typical pumping duration (hours/day) 10 PUMP Make Goulds Type Vertical Turbine Size (hp) 350 *Capacity (gpm) 2,500 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) pressure Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) distribution system REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 80 10/20/2026 WellData/W28 6/9/2010 WELL DATA SHEET(Page 27 of 3 Complete as much information as possible, Leave blank If information is not available, use N.A.if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re=Residential, Co=Commercial, i provided. I= Industrial, Mu=Municipal, P= Pristine, O=Other 2.Conductor Casing-Oversized casing used to stabilize bore hole during well I-Sampling taps are construction. Should be removed during installationof annular seal_ _ ,located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. City Council 22 — 61 10/20/2026 WellData/W28 6/9/2010 WELL DATA SHEET (Page 28 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. _ *Indicates items required for Source Water Assessment _ T **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 29 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-13B09 S DWR Well Log on File? ("YES" or"NO") _1 State Well Number(from DWR) 05S/10W-13B09 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121482.945 from DHS database Longitude 424350.906 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 101.81 Street Address - Nearest Cross Street First St. & Flower City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR, DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS j **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 283 Distance to Abandoned Wells (ft) 169 Distance to Surface Water(ft) **Size of controlled area around well (square feet) 2,460 *Type of access control to well site (fencing, building, etc) fence Surface Seal? (Concrete slab)( YES , NO or UNKNOWN ) YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 5/5/8 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") NO Run off only. ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) fencing Floor material concrete Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION j Date drilled 12/23/1980 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,090 Casing Beginning Depth/Ending Depth(ft below surface); 0-100; 100-1050; 1050- 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 1070 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 20; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 82 10/20/2026 WellData/W29 6/9/2010 WELL DATA SHEET (Page 29.of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *indicates items required for Source_Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN') NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 450 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 450-1050 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 600 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 100 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft-below ground surface) 100 Total length of gravel pack (ft) 990 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply: sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default= 0.2) (or"UNKNOWN') UNKNOWN default * Confining layer(Impervious Strata)above aquifer? ("YES", "NO"or"UNKNOWN') - YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 135 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 214 Pumping water level measurement: Date/Method 10/31/2001 WELL PRODUCTION Well Yield (gpm) 2,448 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES i Production (gallons per year) 784,584,038 Frequency of Use (hours/year) 4,378 Typical pumping duration (hours/day) 12 PUMP Make Goulds Type Vertical Turbine Size (hp) 200 * Capacity (gpm) 2,500 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES" or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? "YES"or"NO") NO Run off only Discharges to: (i.e., distribution system, storage, etc.) Walnut Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 83 10/20/2026 WellData/W29 6/9/2010 WELL DATA SHEET (Pacie 30 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source WaterAssessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru = -Continuous chlorination is Rural, Re= Residential, Co=Commercial, provided. I = Industrial, Mu =Municipal, P= Pristine, O=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well '-Sampling taps are construction. Should be removed during installation of annular seal. located at discharge 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. i I I I City Council 22 - 84 10/20aq?� WeIIDat /W29 I WELL DATA SHEET (Page 31 of 3 i Complete as much information as possible. Leave blank if information is_not available, use N.A. if not applicable__ *Indicates items required for Source WaterAssessment L **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 30 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-16B04 S DWR Well Log on File? ("YES" or"NO") State Well Number (from DWR) 05S/10W-16B04 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION j Latitude 121469.953 from DHS database Longitude 424532.594 from DHS database, Ground Surface Elevation (ft above Mean Sea Level) 63.2 Street Address 207 S. Mountain View Nearest Cross Street Mnt.View&Newhope City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin Ito.come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 567 Distance to Abandoned Wells (ft) 668 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 4,000 *Type of access control to well site (fencing, building, etc) fence * Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 4/4/9 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") NO I Run off only ENCLOSURE/HOUSING j Enclosure Type building, vault, none, etc.) fencing Floor material concrete Located in Pit. "YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 10/16/1982 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 989 Casing Beginning Depth/Ending Depth(ft below surface); 0-100; 100-280; 280-900; 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 900-920 Casing Diameter (inches); 2nd Casing Diameter; 3rd Casing, etc. 30; 18; 14; 14 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel; Steel City Council 22 — 85 10/20/2026 Well Data/W30 6/9/2010 WELL DATA SHEET (Page 32 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule it (separate multiple entries in Actual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN') NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 440 Screened Interval Beginning Depth/Ending Depth (ft below surface); 440-580; 600-740; 760- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 900 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 420 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 100 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 0 Total length of gravel pack (ft) 989 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default * Confining layer (Impervious Strata) above aquifer? ("YES", "NO"or"UNKNOWN') YES Thickness of confining layer, if known (ft) Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 96 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 119 Pumping water level measurement: Date/Method 11/19/2001 WELL PRODUCTION Well Yield (gpm) 2,321 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 759,949,702 Frequency of Use (hours/year) 4,435 Typical pumping duration (hours/day) 12 PUMP Make Vertiline Type Vertical Turbine Size (hp) 150 *Capacity (gpm) 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") NO Run off only Discharges to: (i.e., distribution system, storage, etc.) West Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) I City Council 22 — 86 10/20/202� WellData/W30 6/9/20 0 WELL DATA SHEET (Page 33 of 3 Complete as much information as possible. Leave blank if information is not available, use_N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule _ _NOTES__ 1 Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re= Residential, Cc=Commercial, provided at reservoir. I =Industrial, Mu = Municipal, P= Pristine, O= Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall! of the drilled hole. Sometimes called "sanitary seal'. j City Council 22 — 87 10/20/2U� WellDa a/W30 6/9/20 WELL DATA SHEET (Page 34 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 31 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/09W-17B01 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/09W-17B01 Well Status (Active, Standby, Inactive) Active from DHS database ` WELL LOCATION Latitude 121474.820 from DHS database Longitude 424223.188 from.DHS database. Ground Surface Elevation (ft above Mean Sea Level) 128.68 Street Address 1815 E. Chestnut St. Nearest Cross Street Chestnut&SA Freeway City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come from DWR DWR Ground Water Sub-basin Main Basin to come from DWR ; SANITARY CONDITIONS ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells(ft) 3,855 Distance to Abandoned Wells (ft) 1,703 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 800 *Type of access control to well site (fencing, building, etc) building *Surface Seal? (Concrete slab)("YES", "NO"or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick in 5/5/18 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING j Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO" NO - Pit depth (feet) (if applicable) WELL CONSTRUCTION Date drilled 9/29/1984 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,310 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-296; 296-1260 Casing Diameter (inches); 2nd Casing Diameter; 3rd Casing, etc. 20; 16 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel i City Council 22 — 88 10/20/2026 WellData/W31 6/9/2010 i WELL DATA SHEET (Page 35 of 3 Complete as much information as possible. Leave _b lank if information t-io n-is.not available, lable,—us-e N.A, if-n—ot applicable.*Indicates qso res - ---- 1 dicates items dditonal item required oasessments and Ground Water Rule - I (separate multiple entries in lActual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") - * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 465 465-495;555-645;665-685;715- 745;785-805;845-865;885- Screened Interval Beginning Depth/Ending Depth (ft below surface); 1005;1085-1095; 1125-1135; 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 1200-1210; 1230-1240 *Total length of screened interval A (default= 10%pump capacity in gpm) (or"UNKNOWN') 370 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 235 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN') YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 159 Static water level measurement: Date/Method 10/29/2001 Pumping water level (ft below ground surface) 234 Pumping water level measurement: Date/Method 10/30/2001 WELL PRODUCTION Well Yield (gpm) 3,299 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 1,265,214,263 Frequency of Use (hours/year) 4,910 Typical pumping duration (hours/day) 12 PUMP Make Worthington Type Vertical Turbine Size (hp) 400 * Capacity (gpm) 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? "YES" or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) pressure Pump to Waste capability? ("YES" or"NO") NO Run off only Discharges to: (i.e., distribution system, storage, etc.) distribution system REMARKS AND DEFECTS (use additional sheets as necessary) _ City Council 22 — 89 10/20/2026 WellData/W31 6/9/2010 WELL DATA SHEET (Page 36 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *In_dicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule _ NOTES _ 1. Neighborhood/Surrounding Area (list all that apply):A=Agricultural, Ru = -Continuous chlorination is Rural, Re=Residential, Co=Commercial, provided. I= Industrial, Mu = Municipal, P= Pristine, O= Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. I located at discharge pipe. I_ 3.Annular Seal-Seal of grout in the space between the well casing and the wall' of the drilled hole. Sometimes called"sanitary seal'. i i i City Council 22 — 90 10120 qAA 0 WeilDa /W31 i WELL DATA SHEET (Page 37 of 3 \ Complete as much information as possible. Leave blank if information is not available, use N__.A, if not applicable. Indicates items required for Source Water Assessment i **Indicates additional items required for assessments and Ground Water Rule --� (separate multiple entries in jActual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION j System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION j *Well Number or Name Well No. 32 from DHS database * DHS Source Identification Number(FRDS ID No.) 04S/10W-36Q01 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 04S/10W-36Q01 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121588.367 from DHS database Longitude 424365.406 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 114.31 Street Address 2801 N. Westwood Morrison Park Nearest Cross Street Westwood & Corrigan City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin Ito come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR:.. SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 2,174 i Distance to Abandoned Wells (ft) 1,187 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 600 *Type of access control to well site (fencing, building, etc) vault *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 4/4/8 Estimated *Within 100 year flood plain? ("YES", "NO"or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ISUMP pump ENCLOSUREIHOUSING j Enclosure Type (building, vault, none, etc. vault Floor material concrete Located in Pit? "YES" or"NO" YES Pit depth (feet) (if applicable) 25 Estimated WELL CONSTRUCTION Date drilled 8/1/1984 Drilling Method Reverse Rotary Depth of Bore Hole(feet below ground surface) 1,060 Casing Beginning Depth/Ending Depth(ft below surface); 0-290;290-297;297-990;990- i 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 1030 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 28; 20; 16; 16 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel; Steel City Council 22 — 91 10/20/2026 WellData/W32V 6/9/2010 I WELL DATA SHEET (Page 38 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO"or"UNKNOWN") (See Note 2) YES I Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 307 307-367;478-488; 538-578;588- Screened Interval Beginning Depth/Ending Depth (ft below surface); 598;658-758;819-829;869-889; 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval,.etc. 990-1030 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 290 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 290 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 290 Total length of gravel pack (ft) 740 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 116 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 228 Pumping water level measurement: Date/Method 9/26/2001 WELL PRODUCTION Well Yield (gpm) 2,127 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES"or"NO") YES . Production (gallons per year) 642,121,981 Frequency of Use (hours/year) 4,466 Typical pumping duration (hours/day) 12.5 PUMP Make US Motor Type Vertical Turbine Size (hp) 300 *Capacity (gpm) 2,700 Depth to suction intake (ft below ground surface) 270 Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) pressure Pump to Waste capability? ("YES"or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) distribution system REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 92 10/20/2026 WellData/W32V 6/9/2010 WELL DATA SHEET(Page 39 of 3 Complete as much information as possible. Leave blank if information is not available, useN.A.If not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= I-Continuous chlorination is Rural, Re=Residential, Co=Commercial, 'provided. I I= Industrial, Mu= Municipal, P= Pristine, O=Other 2.Conductor Casing-Oversized casing used to stabilize bore hole during well I-Sampling taps are construction. Should be removed during Installation of annular seal. located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. -Equip with 2 online NO3 analyzers due to high (Nitrate levels. City Council 22 — 93 10/20/2026 WeIIDa a/W32V 6/9 2010 WELL DATA SHEET (Page 40 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if no_t applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 33 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-13CO3 S DWR Well Log on File? ("YES" or"NO") -I State Well Number(from DWR) 05S/10W-13CO3 S Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION j Latitude 121480.992 from DHS database Longitude 424354.812 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 99.8 Street Address 917 W. Walnut St. Nearest Cross Street Walnut& Flower City Santa Ana County Orange r * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES - DWR Ground Water Basin OC Groundwater Basin to come from DWR `> DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS j ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 60 Estimated Distance to Active Wells (ft) 434 Distance to Abandoned Wells (ft) 116 Distance to Surface Water (ft) ** Size of controlled area around well (square feet) 6,875 *Type of access control to well site (fencing, building, etc) fencing and building *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES *Dimensions of concrete slab: Length(ft)/Width ft /Thick(in) 5/5112 *Within 100 year flood plain? ("YES", "NO"or"UNKNOWN") NO * Drainage away from well? ("YES"or"NO") I YES IRun off only ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION j Date drilled 10/16/1986 Drilling Method Direct Rotary Depth of Bore Hole feet below ground surface 1,080 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-60; 60-295; 295-1028 Casing Diameter (inches); 2nd Casing Diameter; 3rd Casing, etc. 34; 20; 16 i Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 94 10/20/2026 WellData/W33 6/9/2010 WELL DATA SHEET (Page 41 of 3 Complete as much information as possible. Leave blank if information is not available, use_N.A. if_n_not t applicable. *Indicates items required for Source_Water Assessment _ **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) j Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 425 Screened Interval Beginning Depth/Ending Depth (ft below surface); 425-445;455-515; 555-625;680- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 800;845-855;885-935 *Total length of screened interval A (default= 10%pump capacity in gpm) (or"UNKNOWN") 330 *'Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 60 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 0 Total length of gravel pack (ft) 1028 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default * Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level (ft below ground surface) 133 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 195 Pumping water level measurement: Date/Method 11/30/2001 WELL PRODUCTION j Well Yield (gpm) 2,589 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production gallons per year) 773,830,955 Frequency of Use (hours/year) 4,119 Typical pumping duration (hours/day) 12 PUMP j Make Goulds Type Vertical Turbine Size (hp) 250 * Capacity (gpm) 2,800 Depth to suction intake (ft below ground surface) 270 Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? "YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level in tank Pump to Waste capability? ("YES" or"NO") YES Run off only Discharges to: (i.e., distribution system, storage, etc.) Walnut Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) i i City Council 22 — 95 10/20/2026 WellData/W33 6/9/2010 WELL DATA SHEET(Page 42 of 3 Complete as much information as possible_ Leave blank if information is not available, use N.A. If not applicable__ *Indicates items required for Source _Water Assessment **Indicates additional items required for assessments and Ground Water Rule NOTES 1.Neighborhood/Surrounding Area(list all that apply);A=Agricultural, Ru= !-Continuous chlorination is Rural, Re=Residential,Co=Commercial, provided. I = Industrial, Mu=Municipal, P=Pristine, 0=Other_ _-- 2.Conductor Casing-Oversized casing used to stabilize bore hole during well -Reservoir's level ON @ ! construction. Should be removed during installation of annular seal. _ _ 16 ft and OFF @ 18.5 ft. 3.Annular Seal-Seal of grout in the space between the well casing and the wall I of the drilled hole. Sometimes called"sanitary seal". I i _I i 1 I City Council 22 — 96 10/20/2026 WeIIDa a/W33 6/9/2010 WELL DATA SHEET (Page 43 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source_Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 34 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-26Q02 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-26Q02 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION ( j Latitude 121336.703 from DHS database Longitude 424405.000 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 35 Street Address 1727 W. Alton Ave. Nearest Cross Street Alton & Bear City Santa Ana County Orange *Neighborhood/Surrounding Area see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin Ito come from DWR DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 60 Estimated Distance to Active Wells (ft) 666 Distance to Abandoned Wells (ft) 2,059 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 21,780 0.5 acre *Type of access control to well site (fencing, building, etc) fencing and building *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 4/4/14 *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSUREIHOUSING ! j Enclosure Type (building, vault, none, etc.) fencing Floor material concrete Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - I WELL CONSTRUCTION Date drilled 10/1/1990 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,000 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-520; 520-810; 810-830 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 18; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 97 10/20/2026 WellData/W34 6/9/2010 WELL DATA SHEET (Page 44 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment___ **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) jor Default?. WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO"or"UNKNOWN") - * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 370 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 370-810 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 440 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 325 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 325 Total length of gravel pack (ft) 675 AQUIFER + *Aquifer Materi'als Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default * Confining layer (Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - * Static water level ft below ground surface 86 Static water level measurement: Date/Method 11/20/2001 Pumping water level (ft below ground surface) 160 Pumping water level measurement: Date/Method 10/29/2001 WELL PRODUCTION Well Yield (gpm) 1,626 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES I Production (gallons per ear) 4,464,159 Frequency of Use (hours/year) 1,462 Typical pumping duration (hours/day) 4.5 PUMP Make Flowa Type Vertical Turbine Size (hp) 125 *Capacity (gpm) 1,600 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? "YES"or"NO" NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") YES i Discharges to: (i.e., distribution system, storage, etc.) South Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 98 10/20/2026 WellData/W34 6/9/2010 WELL DATA SHEET(Page 45 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A.if not applicable_ *Indicates items required for Source Water Assessment_ _ **Indicates additional items required for assessments and Ground Water Rule _ NOTES _ 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural,Ru= -Continuous chlorination Is Rural, Re=Residential, Co=Commercial, provided. I=Industrial, Mu=Municipal, P=Pristine, 0=Other 2. Conductor Casing-Oversized casing used to stabilize borehole during well FLower Zones are sealed construction, Should be removed during installation of annular seal. -off at 530 ft to isolate high _ 3.Annular Seal-Seal of grout in the space between the well casing and the wall color H2O. i of the drilled hole. Sometimes called"sanitary seal'. I ; i I " City Council 22 — 99 10/20/2026 WeIIDa a/W34 6/9/2010 WELL DATA SHEET (Paq a 46 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database j System Number 3010038 from DHS database . Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 35 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-03R03 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-03R03 Well Status (Active, Standby, Inactive) Active from DHS database: WELL LOCATION Latitude 121538.367 from DHS database' Longitude 424458.312 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 95 Street Address 1718 N. Sydney Place Nearest Cross Street Sydney&Westminster City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin ItocomefromDWR, DWR Ground Water Sub-basin I Main Basin I to<come:from DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 100 Estimated Distance to Active Wells (ft) 1,988 Distance to Abandoned Wells (ft) 422 Distance to Surface Water(ft) ** Size of controlled area around well (square feet) 6,840 *Type of access control to well site (fencing, building, etc) walls *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 5/5/12 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING j Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 5/6/1992 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,520 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-50; 50-1500 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 33.62; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. I Steel; Steel City Council 22 — 100 10/20/2026 Well Data/W35 6/9/2010 WELL DATA SHEET (Page 47 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment j **Indicates additional items required for assessments and Ground Water Rule I (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 429 429-449;499-519; 559-669;729- Screened Interval Beginning Depth/Ending Depth (ft below surface); 809;869-969; 1149-1380; 1430- 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 1480 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 610 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 60 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 370 Total length of gravel pack (ft) 1150 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default ( *Confining layer(Impervious Strata)above aquifer? I ("YES", "NO" or"UNKNOWN') YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - i *Static water level (ft below ground surface) 125 Static water level measurement: Date/Method 1128/01 Pumping water level (ft below ground surface) 163 Pumping water level measurement: Date/Method 11/19/2001 WELL PRODUCTION Well Yield (gpm) 2,379 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 966,734,747 Frequency of Use (hours/year) 6,682 Typical pumping duration (hours/day) 20 PUMP Make Byron Jackson Type Vertical Turbine Size (hp) 350 * Capacity (gpm) 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Tye of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc. pressure Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) distribution system REMARKS AND DEFECTS (use additional sheets as necessary) City Council 22 — 101 10/20/629 WellData/W35 WELL DATA SHEET (Page 48 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. `Indicates items required for Source Water Assessment ___ **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination isl Rural, Re= Residential, Co=Commercial, provided. I = Industrial, Mu= Municipal, P= Pristine, 0=Other 2. Conductor Casing -Oversized casing used to stabilize bore hole during well -Sampling taps are construction. Should be removed during installation of annular seal. !located at discharge pipe. 3.Annular Seal-Seal of grout in the space between the well casing and the wall) of the drilled hole. Sometimes called"sanitary seal'. II I J 1 City Council 22 — 102 10/201202� WeIIDa a/W35 WELL DATA SHEET (Page 49 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 36 from DHS database * DHS Source Identification Number (FRDS ID No.) 05S/10W-01 E03 S DWR Well Log on File? ("YES"or"NO") —� State Well Number(from DWR) 05S/10W-01 E03 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121569.148 from DHS database Longitude 424380.688 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 12.25 Street Address 2415 N. Bristol St. Nearest Cross Street Bristol & Santa Clara City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin o come from DWR DWR Ground Water Sub-basin Main Basin ito come.from DWR SANITARY CONDITIONS *" Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 100 Estimated Distance to Active Wells (ft) 455 Distance to Abandoned Wells (ft) 140 Distance to Surface Water(ft) *`Size of controlled area around well (square feet) 1,200 20x60 *Type of access control to well site (fencing, building, etc) fencing and building * Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 5/5/20 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSUREIHOUSING Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 12/7/1987 Drilling Method Direct Rotary Depth of Bore Hole (feet below ground surface) 1,510 Casing Beginning Depth/Ending Depth(ft below surface); 0-350; 350-1310; 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 1310-1290 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 1 20; 18; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. I Steel; Steel; Steel City Council 22 — 103 10/20/2026 WellData/W36 6/9I2010 WELL DATA SHEET (Page 50 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source_Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) lor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) NO Conductor casing removed? ("YES", "NO" or"UNKNOWN") { *Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 570 Screened Interval Beginning Depth/Ending Depth (ft below surface); 570-630;680-770;850-950; 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 1030-1130; 1190-1290 " Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 450 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 440 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 440 Total length of gravel pack (ft) 870 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply: sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default *Confining layer(Impervious Strata) above aquifer? ("YES", "NO"or"UNKNOWN") YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 147 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface) 178 Pumping water level measurement: Date/Method 11/30/2001 WELL PRODUCTION Well Yield (gpm) 3,131 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 1,118,972,334 Frequency of Use (hours/year) 4,731 Typical pumping duration (hours/day) 14 PUMP ; l Make Ingersoll Type Vertical Turbine Size (hp) 250 * Capacity (gpm) 3,600 Depth to suction intake (ft below ground surface) 270 Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? "YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level in tank Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) John Garthe Reservoir REMARKS AND DEFECTS (use additional sheets as necessary) I City Council 22 — 104 10/20/2026 WellData/W36 6/9/2010 WELL DATA SHEET (Page 51 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items re uired for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule _ NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re= Residential, Cc=Commercial, provided. I= Industrial, Mu=Municipal, P= Pristine, O=Other 2. Conductor Casing-Oversized casing used to stabilize bore hole during well -Reservoir's level ON @ construction. Should be removed during installation of annular seal. I25 ft and OFF @ 28 ft. 3. Annular Seal-Seal of grout in the space between the well casing and the wall' of the drilled hole. Sometimes called "sanitary seal". City Council 22 — 105 10/20/202� WellDa a/W36 i I I Complete as much information as possible. Leave blank if information is not available, w *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in field with semi-colon) DATA SHEET GENERAL INFORMATION System Name City of Santa Ana System Number 3010038 Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS j Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 37 ' DHS Source Identification Number(FRDS ID No.) 05S/10W-14L01 S DWR Well Log on File? ("YES"or"NO") State Well Number(from DWR) 05S-10W-141-01 Well Status (Active, Standby, Inactive) Active WELL LOCATION Latitude 121590.906 Longitude 424237.594 Ground Surface Elevation (ft above Mean i Sea Level) 200 Street Address 2736 N. Cambridge St. Nearest Cross Street Fairhaven & Cambridge City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin DWR Ground Water Sub-basin Main Basin SANITARY CONDITIONS ** Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 100 Distance to Active Wells (ft) 1,283 Distance to Abandoned Wells (ft) 845 Distance to Surface Water(ft) **Size of controlled area around well (square feet) 21,780 *Type of access control to well site (fencing, building, etc) fencing and building *Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/ Width(ft)/Thick(in) 5/5/16 *Within 100 year flood plain? ("YES", "NO" or "UNKNOWN") NO *Drainage away from well? ("YES" or"NO") YES City Council 22 — 106 10/20/2026 i ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) fencing Floor material concrete Located in Pit? ("YES"or"NO") NO Pit depth (feet) (if applicable)WELL CONSTRUCTION Date drilled 8/18/1992 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,510 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 59.5;1300 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 33.25; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel (separate multiple entries in field with semi-colon) WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO"or i "UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO'-' or "UNKNOWN") UNKNOWN 7 Depth to highest perforations/screens (ft below surface) (or"UNKNOWN") 399 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 399-429; 509-649; 879-959; 3rd Screened Interval, etc. 1109-1269 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or "UNKNOWN") 410 *Annular Seal?("YES", "NO"or "UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 350 Material of Annular Seal (cement grout, bentonite, etc.) Cement Grout Sanitary Seal Gravel pack, Depth to top (ft below ground surface) 350 Total length of gravel pack (ft) 950 AQUIFER *Aquifer Materials (list all that apply.,sand, silt, clay, gravel, rock, fractured rock) Sands, silts, clays, gravel, rocks * Effective porosity(decimal percent) (default = 0.2) (or"UNKNOWN") UNKNOWN *Confining layer(Impervious Strata) above aquifer? ("YES", "NO"or"UNKNOWN") YES City Council 22 — 107 10/20/2026 i Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 211 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 305 Pumping water level measurement: Date/Method 11/28/2001 WELL PRODUCTION Well Yield (gpm) 1,819 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES"or"NO") YES Production (gallons per year) 698,233,523 Frequency of Use(hours/year) 4,312 Typical pumping duration (hours/day) 12 PUMP Make Johnston Type Vertical Turbine Size (hp) 350 *Capacity (gpm) 2,500 Depth to suction intake(ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ('YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) pressure Pump to Waste capability? ("YES"or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) distribution system REMARKS AND DEFECTS(use additional sheets as necessary) NOTES 1. Neighborhood/Surrounding Area(list all that -Continuous chlorination is apply):A=Agricultural, Ru = Rural, Re= provided. Residential, Co= Commercial, I = Industrial, Mu= Municipal, P= Pristine, 0= Other 2. Conductor Casing -Oversized casing used to -Sampling taps are located at stabilize bore hole during well construction. discharge pipe. Should be removed during installation of annular seal. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. City Council 22 — 108 10/20/2026 -Brine solution line has an excessive leak. 7/14/04 II I I City Council 22 — 109 10/20/2026 i I se N.A. if not applicable. i Actual, Estimated or Default? from DHS database from DHS database I from DHS database from DHS database from DHS database from DHS database to come from DWR to come from DWR Estimated .5 acre Estimated City Council 22 — 110 10/20/2026 i Actual, Estimated or Default? I default City Council 22 — 111 10/20/2026 i VFD I I j I City Council 22— 112 10/20/2026 WELL DATA SHEET(Page 59 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 38 from DHS database * DHS Source Identification Number(FRDS ID No.) 04S/09W-32P02 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 04S/09W-32P02 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION j Latitude 121590,906 from DHS database Longitude 424237.594 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 200 Street Address 2736 N. Cambridge St. Nearest Cross Street Fairhaven &Cambridge City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES"or"NO") YES DWR Ground Water Basin OC Groundwater Basin Ito`come from DWR DWR Ground Water Sub-basin Main Basin I to come from DWR',' SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) 100 Estimated Distance to Active Wells (ft) 1,283 Distance to Abandoned Wells (ft) 845 Distance to Surface Water(ft) **Size of controlled area around well (square feet) 21,780 .5 acre *Type of access control to well site (fencing, building, etc) fencing and building * Surface Seal? Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 5/5/16 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING j Enclosure Type (building, vault, none, etc.) fencing Floor material concrete Located in Pit? ("YES" or"NO") NO Pit depth (feet) (if applicable) - - WELL CONSTRUCTION Date drilled 8/18/1992 Drilling Method Reverse Rotary Depth of Bore Hole (feet below ground surface) 1,510 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 59.5;1300 Casing Diameter (inches); 2nd Casing Diameter; 3rd Casing, etc. 33.25; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel City Council 22 — 113 10/20/2026 WellData/W38 6/9/2010 WELL DATA SHEET (Page 60 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source_Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO"or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") UNKNOWN * Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 399 Screened Interval Beginning Depth/Ending Depth (ft below surface); 399-429; 509-649; 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 879-959; 1109-1269 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 410 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 350 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) 350 Total length of gravel pack (ft) 950 AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply:sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity (decimal percent) (default= 0.2) (or"UNKNOWN") UNKNOWN default *Confining layer(Impervious Strata) above aquifer? ("YES" "NO" or"UNKNOWN") - YES Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 211 Static water level measurement: Date/Method 11/27/2001 Pumping water level (ft below ground surface) 305 Pumping water level measurement: Date/Method 11/28/2001 WELL PRODUCTION Well Yield (gpm) 1,819 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 7/5/2001 Is the well metered? ("YES" or"NO") YES Production (gallons per year) 698,233,523 Frequency of Use (hours/year) 4,312 Typical pumping duration (hours/day) 12 PUMP Make Johnston Type Vertical Turbine Size (hp) 350 * Capacity (gpm) 2,500 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) Electric Auxiliary power available? ("YES" or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) pressure Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) distributions stem REMARKS AND DEFECTS (use additional sheets as necessary) I City Council 22 — 114 10/20/�P WellData/W38 9/ 10 WELL DATA SHEET (Page 61 of 3 Complete as much information as possible. Leave blank if information is not available, use_N.A.if not applicable. _ *Indicates items required for Source_Water Assessment —— — **Indicates additional items required for assessments and Ground Water Rule _NOTES 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, Ru = -Continuous chlorination is Rural, Re=Residential,Co=Commercial, provided. I=Industrial, Mu=Municipal, P=Pristine,0=Other 2. Conductor Casing-Oversized casing used to stabilize borehole during well I-Sampling taps are construction. Should be removed during installation of annular seal. jlocated at discharge pipe. 3.Annular Seal Seal of grout to the space between the well casing and the wall of the drilled hole Sometimes called "sanitary seal'. -Brine solution line has an excessive leak. 17/14/04 City Council 22 — 115 10120139��o WellData/W38 WELL DATA SHEET (Page 62 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable.- *Indicates items required for Source WaterAssessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in Actual, Estimated field with semi-colon) or Default? DATA SHEET GENERAL INFORMATION System Name City of Santa Ana from DHS database System Number 3010038 from DHS database Source of Information (well log, DHS/County files, system, etc) DHS files, system Organization Collecting Information (DHS, County, System, other) DHS Date Information Collected/Updated 1/27/2009 WELL IDENTIFICATION *Well Number or Name Well No. 39 from DHS database * DHS Source Identification Number(FRDS ID No.) 05S/10W-01 E04 S DWR Well Log on File? ("YES" or"NO") State Well Number(from DWR) 05S/10W-01 E04 Well Status (Active, Standby, Inactive) Active from DHS database WELL LOCATION Latitude 121565.383 from DHS database . Longitude 424381.188 from DHS database Ground Surface Elevation (ft above Mean Sea Level) 117.7 Street Address 2315 N. Bristol St. Nearest Cross Street Bristol St. & Santa Clara City Santa Ana County Orange * Neighborhood/Surrounding Area (see Note 1) Re, Mu, Co, I Site plan on file? ("YES" or"NO") YES DWR Ground Water Basin OC Groundwater Basin to come.from DWR i DWR Ground Water Sub-basin Main Basin Ito come from DWR SANITARY CONDITIONS **Distance to closest Sewer Line, Sewage Disposal, Septic Tank(ft) >50 Estimated Distance to Active Wells (ft) 383 Distance to Abandoned Wells (ft) 245 Distance to Surface Water(ft) **Size of controlled area around well (square feet) •Type of access control to well site (fencing, building, etc) fencing and building * Surface Seal? (Concrete slab)("YES", "NO" or"UNKNOWN") YES * Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 5/5/18 Estimated *Within 100 year flood plain? ("YES", "NO" or"UNKNOWN") NO * Drainage away from well? ("YES" or"NO") YES ENCLOSURE/HOUSING Enclosure Type (building, vault, none, etc.) building Floor material concrete Located in Pit? "YES" or"NO" NO Pit depth (feet) (if applicable) - WELL CONSTRUCTION Date drilled 6/13/2000 Drilling Method Reverse Rotary Depth of Bore Hole feet below ground surface 1,350 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 50; 360; 1310 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 37.25; 20; 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Steel; Steel; Steel City Council 22 — 116 10/20/2026 WellData/W39 6/9/2010 WELL DATA SHEET (Page 63 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicate_s items required for Source Water Assessment "*Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in lActual, Estimated field with semi-colon) jor Default? WELL CONSTRUCTION (continued) Conductor casing used? ("YES", "NO" or"UNKNOWN") (See Note 2) YES Conductor casing removed? ("YES", "NO" or"UNKNOWN") NO Depth to highest perforations/screens (ft below surface) (or "UNKNOWN") 360 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. 360-1310 *Total length of screened interval (ft) (default= 10%pump capacity in gpm) (or"UNKNOWN") 950 *Annular Seal?("YES", "NO" or"UNKNOWN") (See Note 3) YES * Depth of Annular Seal (ft) 50 Cement Grout Sanitary Material of Annular Seal (cement grout, bentonite, etc.) Seal Gravel pack, Depth to top (ft below ground surface) Total length of gravel pack (ft) AQUIFER *Aquifer Materials Sands, silts, clays, gravel, (list all that apply: sand, silt, clay, gravel, rock, fractured rock) rocks * Effective porosity(decimal percent) (default=0.2) (or"UNKNOWN") UNKNOWN default *Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") YES - Thickness of confining layer, if known (ft) - Depth to confining layer, if known (ft below ground) - *Static water level (ft below ground surface) 134 Static water level measurement: Date/Method 11/19/2001 Pumping water level (ft below ground surface Pumping water level measurement: Date/Method WELL PRODUCTION Well Yield (gpm) 3,500 Well Yield Based On (i.e., pump test, etc.) Actual use Date measured 12/3/2001 Is the well metered? ("YES" or"NO") YES Production gallons per ear) Frequency of Use (hours/year) Typical pumping duration (hours/day) PUMP Make Johnston Type Vertical Turbine Size (hp) 250 *Capacity (gpm) 3,000 Depth to suction intake (ft below ground surface) Lubrication Type Water Type of Power: (i.e., electric, diesel, etc.) electric Auxiliary power available? ("YES"or"NO") NO Operation controlled by: (i.e., level in tank, pressure, etc.) level Pump to Waste capability? ("YES" or"NO") YES Discharges to: (i.e., distribution system, storage, etc.) Garthe Reservoir REMARKS AND DEFECTS (use additional sheets as necessary)___. --- ----- ------------ City Council 22 — 117 10/20/2026 WellData/W39 6/9/2010 WELL DATA SHEET(Page 64 of 3 Complete as much information as possible. Leave blank if information is not available, use N.A. if not applicable. *Indicates items required for Source WaterAssessment �- j **Indicates additional items required for assessments and Ground Water Rule NOTES 1. Neighborhood/Surrounding Area (list all that apply):A=Agricultural, Ru= -Continuous chlorination is Rural, Re= Residential, Co=Commercial, provided. I = Industrial, Mu=Municipal, P= Pristine, O=Other __ __ 2. Conductor Casing-Oversized casing used to stabilize bore hole during well Sampling taps are construction. Should be removed during installation of annular seal. ;located at discharge pipe. I 3. Annular Seal-Seal of grout in the space between the well casing and the wall' of the drilled hole. Sometimes called"sanitary seal'. I I City Council 22 — 118 10/20/202� WeIIDa a/W39 6/9/20 Complete as much information as possible. Leave blank if information is not available, use N.A. if I Indicates items required for Source Water Assessment Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in field with semi-colon) D R� AT-., ATASHEETI GENERA System Name City of Santa Ana System Number 3010038 Source of Information (well log, DHS/County files, sXstem, etc) System Organization Collecting Information (UHS, County, System, other) System Date Information Collected/Updated 1/27/2009 WELL IDENTIFUQATION' *Well Number or Name Well 40 * DHS Source Identification Number 3010038-073 DWR Well Log on File? (yes or no) Yes State Well Number (from DWR) 05S/09W-08G02 Well Status (Active, Standby, Inactive) Active V LL A Latitude 33,753 Longitude 117.8422 Ground Surface Elevation (ft above MSL) 153 Street Address 1301 Mabury Park Nearest Cross Street Fruit St./Mabury St. City Santa Ana County Orange *Neighborhood/Surrounding Area (see Note 1) Re/Co Site plan on file? (yes or no) Yes DWR Ground Water Basin Yes DWR Ground Water Sub-basin SANITARY' '['p CONDITIONS'C Distance to closest Sewer Line,Sewage Disposal, Septic Tank (ft) >50 Distance to Active Wells (ft) 4000 Distance to Abandoned Wells (ft) 1500 Distance to Surface Water(ft) >5000 Size of controlled area around well (square feet) 2,655 Type of access control to well site (fencing, building, etc) building 7Surface Seal? (Concrete slab)(yes or no) Yes *Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 40 x 65 x 6 7Within 100 year flood plain? (yes or no) No 7Drainage away from well? (yes or no) Yes ENCLO9UREIHOUSINGJ,: Enclosure Type (building, vault, none, etc.) Building lFloor material Concrete Located in Pit? (yes or no) No Pit depth (feet) (if applicable) WELL'COINSTRUCTIIOM:' ._�," Date drilled 11/23/2004 Drilling Method Reverse circulation City Council 22 - 119 10/20/2026 I Depth of Bore Hole (feet below ground surface) 1,318 Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-50, 0-528, 528-1300 etc. 34, 18, 18 Casing Material; 2nd Casing Material; 3rd Casing, etc. Type 304 SS I WELL,CONST:RUCTION (cor ttnu;ed)__ rnlfr,e,, with semi colon);' Conductor casing used? (yes, no or not sure) (See Note 2) Yes Conductor casing removed? (yes, no or not sure) No * Depth to highest perforations/screens(ft below surface) 550 surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd 550-1305 capacity in gpm) 224 ;Annular Seal?(yes, no, or not sure) (See Note 3) Yes *Depth of Annular Seal (ft) 470 Material of Annular Seal (cement grout, bentonite, etc.) Cement grout Gravel pack, Depth to top (ft below ground surface) 475 Total length of gravel pack (ft) 890 ;A4UIFER qui er aterla s (list all that apply:sand, silt, clay, gravel, rock, fractured rock) Sand and gravel Effective porosity ecima percent) eau = or "UNKNOWN") 0.3 Confining layer(impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") yes Thickness of confining layer, if known (ft) 75 Depth to confining layer, if known (ft below ground) 400 *Static water level (ft below ground surface) 152 Static water level measurement: Date/Method 3/21/2005 Pumping water level (ft below ground surface) N/A Pumping water level measurement: Date/Method WELL PRODUCTION Well Yield (gpm) 2,500 Well Yield Based On (i.e., pump test, etc.) pump test Date measured 3/1/2005 Is the well metered? ("YES" or"NO") yes Production (gallons per year) N/A Frequency of Use (hours/year) N/A Typical pumping duration (hours/day) N/A PUMP Make Sulzer Type DWT Size (hp) 450 *Capacity (gpm) 2500 Depth to suction intake (ft below ground surface) 335 Lubrication Type water Type of Power: (i.e., electric, diesel, etc.) electric Auxiliary power available? ("YES" or"NO") no Operation controlled by: (i.e., level in tank, pressure, etc.) system pressure Pump to Waste capability? ("YES" or"NO") yes Ru= Rural, Re= Residential,Co=Commercial, I = Industrial, Mu=Municipal, P = Pristine, 0=Other during well construction. Should be removed during installation of iannular seal. City Council 22 — 120 10/20/2026 1 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal". I City Council 22 — 121 10/20/2026 not applicable. Actual, Estimated or Default? r ri Actual Actual Actual Actual )y �I Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual from UC Davis from UC Davis Actual Actual Actual Actual Estimated Actual Actual Estimated Actual Actual Actual Actual Actual Actual Actual Actual City Council 22 — 122 10/20/2026 Actual Actual Actual Actual Actual',,;E!stim'ated or Default?' Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Estimated Estimated Estimated Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual City Council 22 — 123 10/20/2026 i i I i Complete as much information as possible. Leave blank if information is not available, use N.A. if no *Indicates items required for Source Water Assessment **Indicates additional items required for assessments and Ground Water Rule (separate multiple entries in field with semi-colon) DATA SHEET GENERAL INFORMATION, System Name City of Santa Ana System Number 3010038 Source of Information (well log, DHS/County files, system, etc) System Organization Collecting Information (DHS, County, System,' other) System j Date Information Collected/Updated 1/27/2009 1 ; WELL IDENTIFICATION' *Well Number or Name Well 41 *DHS Source Identification Number 3010038-074 DWR Well Log on File? (yes or no) Yes State Well Number(from DWR) 05S/10W-121_05 Well Status (Active, Standby, Inactive) Active W,ELLLOC�4TION Latitude 33.749699 Longitude 117.876404 Ground Surface Elevation (ft above MSL) 110 Street Address 907 3/4 Flower St Nearest Cross Street Flower St./6th St. City Santa Ana li County Orange * Neighborhood/Surrounding Area (see Note 1) Re/Co Site plan on file? (yes or no) Yes DWR Ground Water Basin Coastal Plain of O.C. DWR Ground Water Sub-basin None SANITARY,C.ONDITION ** Distance to closest Sewer Line,Sewage Disposal,Septic Tank (ft) >50 Distance to Active Wells (ft) 450 Distance to Abandoned Wells (ft) 2,000 Distance to Surface Water(ft) 9,600 ** Size of controlled area around well (square feet) 1,733 7 Type of access control to well site (fencing, building, etc) building *Surface Seal? (Concrete slab)(yes or no) Yes *Dimensions of concrete slab: Length(ft)/Width(ft)/Thick(in) 44.5 x 26 x 6 *Within 100 year flood plain? (yes or no) No *Drainage away from well? (yes or no) Yes 'ENCLOSURE/HOUSING" Enclosure Type (building, vault, none, etc.) Building Floor material Concrete Located in Pit? ( es or no) No Pit depth (feet) (if applicable) N/A W_ ELL CONSTRUCTI;ON`f. 1 Date drilled 11/1/2004 City Council 22 — 124 10/20/2026 i ! Drilling Method Reverse circulation Depth of Bore Hole (feet below ground surface) 1,010 Casing Beginning Depth/Ending Depth(ft below surface); 2nd Casing Beginning Depth/Ending Depth; 3rd Casing, etc. 0-50, 0-504, 0-990 Casing Diameter(inches); 2nd Casing Diameter; 3rd Casing, etc. 34, 18, 18 Mild Steel, HSLA Steel, Casing Material; 2nd Casing Material; 3rd Casing, etc. Type 304 SS (separate multiple,entnes � , WELL CON$;,tA CT10N (continued) ,'`. „ . ',;, �n fieId Withsemlrcolon) Conductor casing used? (yes, no or not sure) (See Note 2) Yes - Conductor casing removed? (yes, no or not sure) No * Depth to highest perforations/screens(ft below surface) 525 Screened Interval Beginning Depth/Ending Depth (ft below surface); 2nd Screened Interval Beg. Depth/Ending Depth; 3rd Screened Interval, etc. .525-978 *Total length of screened interval (ft) (default= 10% pump capacity in gpm) 235 *Annular Seal?(yes, no, or not sure) (See Note 3) Yes * Depth of Annular Seal (ft) 421 Material of Annular Seal (cement grout, bentonite, etc.) Cement grout Gravel pack, Depth to top (ft below ground surface) 421 Total length of gravel pack (ft) 594 *Aquifer Materials (list all that apply:sand, silt, clay, gravel, rock, fractured rock) Sand and gravel * Effective porosity(decimal percent) (default= 0.2) (or "UNKNOWN") 0.3 *Confining layer(Impervious Strata) above aquifer? ("YES", "NO" or"UNKNOWN") yes Thickness of confining layer, if known (ft) 50 Depth to confining layer, if known (ft below ground) 225 *Static water level (ft below ground surface) 107 Static water level measurement: Date/Method 2/22/2005 Pumping water level (ft below ground surface) 312 Pumping water level measurement: Date/Method N/A WELL PRODUCTION Well Yield (gpm) 3,000 Well Yield Based On (i.e., pump test, etc.) Proposed Date measured N/A Is the well metered? ("YES" or"NO") yes Production (gallons per year) N/A 1 Frequency of Use (hours/year) N/A Typical pumping duration (hours/day) N/A Make Sulzer Type Vertical Turbine Size (hp) 450 *Capacity (gpm) 3,000 i City Council 22 — 125 10/20/2026 i Depth to suction intake (ft below ground surface) 335 Lubrication Type water Type of Power: (i.e., electric, diesel, etc.) electric Auxiliary power available? ("YES"or"NO") no' Operation controlled by: (i.e., level in tank, pressure, etc.) system pressure Pump to Waste capability? ("YES" or"NO") yes Discharges to: (i.e., distribution system, storage, etc.) distributions stem REMARKS AND DEFECTS (use additional sheets as necessary) 1. Neighborhood/Surrounding Area(list all that apply):A=Agricultural, t Ru = Rural, Re= Residential, Co=Commercial, I = Industrial, Mu= Municipal, P=Pristine, O=Other 2.Conductor Casing-Oversized casing used to stabilize bore hole during well construction. Should be removed during installation of annular seal. 3.Annular Seal-Seal of grout in the space between the well casing and the wall of the drilled hole. Sometimes called"sanitary seal'. i City Council 22 — 126 10/20/2026 i -t applicable. � Actual, Estimated or Default? Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual j Actual Actual Actual Actual from UC Davis from UC Davis Actual Actual Actual Actual Estimated Actual Actual Estimated Actual Actual Actual Actual Actual Actual I Actual City Council 22 — 127 10/20/2026 i Actual Actual Actual I Actual Actual k }. Actual, Estimated or, ®efaul$th i Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual k A , Actual i Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Actual Estimated Estimated Estimated Actual Actual Actual Actual City Council 22 — 128 10/20/2026 Actual Actual Actual Actual Actual Actual Actual City Council 22 — 129 10/20/2026 I Remarks and Defects I j I Well Data Sheet Supplement REMARKS AND DEFECTS jUse or note these items as appropriate) **indicates items pertinent to Ground Water Rule Distance (ft)to other sanitary concerns: _ ** Type_of Sanitary Concem_ ---- - -- - - - - l - - - -- ** Type of Sanitary Concem: ** Type of Sanitary Concern: Type of Sanitary Concern: ** Type of Sanitary Concern: Raw Water Quality concerns? (Yes or Noj ** Microbiological (coliform) _ Chemicals other(list) **Continuous Chlorination provided? Yes or No) _ ____ - Condition of enclosure or housing Pit Drained? (if applicable) Pitless Adaptor? Make and Model Height of pump base(inches) Casing Vent?. _(yes or no).. - Air/Vacuum Release? (yes or now Sampling..Taps?-(yes or no) Location of sampling taps _ Wellhead Riser? (yes or no), height_above well Other i - j Wefff3efeiBefeefe aioronn City Council 22 — 130 10/20/2026 if1� I, y�Q t7 -`55 �� �- ..... �I +'�GI"y� L1�- t +t a•t t t , ��: I. r ,•,.. �':, _-_f ,rt {+� ,.fit t ..� it��i t ,tv �, ti: t N' �,' .'.'• .iN l4.*Si 1���..: 1. �...� �•• �'t`•�h Ski 4:� }•✓, 4 i'� . ��' ® 0 • • O, r ^• • iv kit: '`' ..-K.��t :k kp �1*` 7 th�.,� .,,�•- r .s � '{ � �t )AiSY"1�a`Yy� �7rr,' N�.J•t �' t.•, .F - ut� r Y � f 4t �, 5 .,`•' "� �,'.. �: .� - �dry fin,-_ t $t j.,t ��iY\Siifc y Fv ... �� � ''�"1 t�, M 1 xP��!.`G�1,�',}�,, u 4; '�3 t' �� � �u �i �• � � ��'b'�f` �m�..� �°� rt'� f± �vy�13� m� � -t„ y �,�S�;-� t,, •c�, 1 ' t 1 ',x !',� � �r. YNyks� 1- p z.Y� -t ::y � .,•� S� :� �+.^�4 j;4t f t• k R�y� �i t * �1. ,- r tr�t�4/,� t F`s t $�t ,fit,t� ••,�... � _ x .. .3 - { $tY d. t i_ ,H w� :.: t � v �. . �a x�tC 1�-5 _ ,48`�� 1•r t{fn 4 � j' mc,�Yy�fixt,xT x 1,. _.�t-j;.. ah�r 117 Wk •W4 S� ,rJ� ' �.. �• �t kYJ{y,�; �Aa[. __ .•.I �t SAY � f .L,s � d t! �c�� 3� f V r kj In � r 5 I.. t t MI �r S 4 a CR LOR Operation&Maintenance Manual Table of Contents 1 Introduction MicrOclor System Overview 2 Environmental & Safety Considerations 2.1 Environmental & Safety Considerations 2.2 Hydrogen Vent Piping 2.3 Sodium Hypochlorite Piping & Storage Tank Recommendations 2.4 Sodium Hypochlorite Incompatibility 3 Installation & System Start-up 3.1 Delivery of Equipment& Storage of equipment prior to installation 3.2 Precommissioning 3.3 Startup Procedure 4 System Operation 4.1 Recommendations for Salt,Water Quality, Inlet Water Temperatures & Pressures 4.2 Theory of Operation-Normal Operation of System 4.3 Emergency Shut Down Procedure&Restart Procedure 5 Storage of Operating System 5.1 Short Term Storage (0-10 days) 5.2 Long Term Storage(Over 10 days) 5.3 Restarting the system after Long Term Storage 6 Maintenance 6.1 Recommended Maintenance Schedule 6.2 Acid Wash Procedure 6.3 Brine Solution &Feed Adjustment 6.4 Tank Ventilation Procedure 6.5 Chlorine Test Guide ' 6.6 Neutralization of Acid 6.7 Specific Gravity Testing 6.8 Electrolytic Cell Torque Specifications 6.9 Water Hardness Testing Guide 6.10 Lubrication of system 6.11 List of required maintenance tools &equipment 6.12 Special Tools 6.13 Miscellaneous Service Procedures i��+cennc Inr City Council 22 — 132 10/20/2026 i MICROcLo P. Operation&Maintenance Manual 7 Troubleshooting System Troubleshooting Guide PLC Alarms 8 Chemical Documentation MSDS for: 0.8% Sodium Hypochlorite Sodium Chloride (Salt used for brine solution) Muriatic Acid NSF Certification 9 Auxilliary Equipment -Dosing Pumps -Heaters/Chillers System Specifications &Drawings Warranty Contact information for Manufacturer,Manufacturer's Local Service Representative& subcontractors System Specifications Summary Sheet Mechanical Drawings PLC Drawings PLC &HMI Data Sheets Allen Bradley PLC Panel View Plus HMI Water Softener Hydrogen Dilution Blower Recommended Spare Parts List PSL r ess soi lions.Inc. City Council 22 — 133 10/20/2026 MICROcLoR Operation&Mairate77ance Manual Introduction Welcome to the fast growing family of MICROCLORTM On:Site Sodium Hypochlorite Generation System operators. The advanced design and simplicity of this system allows for ease of operation and maintenance for the operator and the highest efficiencies of operation in the industry. This manual has been prepared to provide the operator with information and instructions regarding the installation,use,maintenance and troubleshooting of your MICROCLOR system. IMPORTANT PRIOR TO OPERATING OR SERVICING YOUR MICROCLOR SYSTEM,THIS MANUAL MUST BE READ AND UNDERSTOOD. KEEP THIS AND OTHER ASSOCIATED MANUALS FOR FUTURE REFERENCE AND FOR NEW OPERATORS. This publication may.not be.reproduced in whole.or part.without the express-written_ permission of Process Solutions,Inc. Process Solutions,Inc.reserves the right to change the contents of this publication without notice. Considerable care was taken in preparing this manual. If,however,you have questions about any part of the manual, or note mistakes or inaccuracies,please contact us at: Process Solutions,Inc. 1077 Dell Ave Suite A, Campbell, CA 95008 Phone number(408) 370 6540 www.4psi.net • Section 1—Introduction City CO 7OCess — 10/20/2026 process solutions,inc, MICROCLOlt Operation d Maintenance Manual Principle of Operation - MICROCLOR On Site Sodium Hypochlorite Generation System (OSHG) Sodium Hypochlorite is generated using the raw materials of salt, water and DC current. A 0.8% Sodium Hypochlorite solution is formed using the basic equation: NaCl +H2O+Electrical Power=NaOC1 +H2 The only byproduct of the process is a small amount of hydrogen gas It takes approximately 3 lbs of salt, 15.gallons of water and 2 kWh of power to create the equivalent of 1 lb of chlorine gas (approximately equivalent to 1 gal of 12.5% commercial strength sodium hypochlorite) How it Works 0C MICR IANI nr I {I I s IIYOROGW ,r 'I _� .� of ✓•t t vF '� . MCTEPoNG PUMP HYPOCHSORITE TANK MICRMOR WN[tANI WATERSORTNER The MICROCLOR system works by feeding softened water into the brine tank to form a saturated (30%) salt solution. This brine solution is pumped via a gear driven pump to a stream of softened water and diluted to approximately 3% salt concentration (a 10:1 ratio of softened water to concentrated brine). . This 3% brine solution is fed into the electrolytic cell (s). A DC voltage from the rectifier is applied to the electrolytic cell, and the brine solution is converted to a 0.8% concentration of sodium hypochlorite. During this conversion, a small amount of hydrogen is produced by the electrolytic process. This hydrogen is released safely through a vent pipe at the top of the electrolytic cell. On larger systems, the small amounts of hydrogen gas are further diluted at a ratio of nearly 100:1 Ee Section I—Introduction City CO rocess 3011111017S,117C.E_ esei red 10/20/2026 process solutions,inc. MICROra oR Operation d'c Maintenance Manual using a dilution air blower which reduces the hydrogen concentration to less than '/a of the Lower Flammable Limit(LFL) of hydrogen gas. The MicrOclor system under normal operation is designed to start and stop sodium hypochlorite production based upon the storage tank level. When the level reaches a preset low level point,the system will automatically turn on. When the tank is full, and the high level point is reached, the MICROCLOR system will turn off. Typically this storage tank is sized for 1-3 days of product requirements. I • Section I—Introduction City COU rocess o u ions,lnc.E_r eser•ve 10/20/2026 process sol Lions,Inc. MICRCLOR .Operation &Maintenance Manual 2.1 Environmental & Safety Considerations General Requirements Alk General Caution: When the MicrOclor system is in operation,there is a potential 150 VDC from the outer most cells to the cell rack frame or earth ground. Furtbernlore, there can be up to 300 VDC between cell 1 and cell 5 on a 5 cell system. The Microclor system should never be operated with the cell guards removed. All service to the system should be performed with the system in the disable mode and the power disconnect in the off position. Smoking should not be allowed near the On-Site Generation System (OSHG) or sodium hypochlorite product storage tanks. No Smoking signs should be posted. Equipment should be installed using good installation practices. These include: • Anchoring liquid tanks and equipment suitable for local environmental conditions including earthquakes &winds. • In areas with freezing weather-Heat tracing of water &brine lines &tanks as - required. + Lightning protection of all at-risk equipment including hydrogen vent stack. • Housekeeping pads for OSHG,tanks,rectifiers and blowers if possible. • Floor Drains near OSHG if possible. • Building construction of non or low combustible materials if possible. • Non-slip flooring (ie. Epoxy floor coating with sand)if possible Environmental Conditions The OSHG is designed for use in an enclosed and ventilated environmentally controlled area. This includes: • OSHG located out of direct sunlight • Temperatures between 40°F & 120°F • Freezing temperatures must be avoided to prevent damage to the electrolytic cell. • Room Ventilation Room Ventilation During system operation and start-up,there should be ventilation in the room. This ventilation may be active ventilation or passive room air changes. Room ventilation is a precautionary measure that will allow for dispersion of any hydrogen gas in the room to quickly disperse in the event that the OSHG piping is damaged. As hydrogen gas rises to the highest point in the room,the ventilation system or passive vents should be located near this high point. In regions of moderate climate,the ventilation can be passive and • Section 2—Environmental&Safety Conditions 2-1 City Co @ipcesssowtions,Inc, 22 — 37 10/20/2026 MICR C;LOR Operation&Maintenance Manual provided by screened openings or louvers. As a general guideline,the inlet&outlet openings should have a minimum total area of 1 ft2/1000 ft3. Inlets should be near the floor and outlets near the ceiling to facilitate natural convective airflow. If the room requires heating or cooling, and it is not practicable to allow large amounts of unconditioned air to enter the building, a small outside vent can be used in addition to the heating/cooling system. NFPA Standard 1 recommends 1 ft3/min/ft2 (0.3048 m3/min/m2). Hydrogen Detection Alarm Depending upon the capacity of the OSHG and the room environmental conditions, a hydrogen detection alarm may be recommended as part of your MICROCLOR system. Hydrogen is a gas that is much lighter than air. It is very difficult to concentrate or trap in a building however it will typically be most concentrated at a high point in the building ceiling near the OSHG. If a hydrogen detector is used,the detector should be installed at a high point in the building a minimum of 3 feet from any hypchlorite sampling ports which may release hydrogen during sampling and trigger a false alarm. Design of the Hydrogen alarm system is site specific. Typically the detector will provide a warning alarm at 20 ppm of hydrogen gas and stop the production of sodium hypochlorite at 50 ppm. Rectifier heat load The rectifier for the OSHG may also create a heat load for the room which should be considered in the room design and may require cooling or ventilation. The rectifier will produce 4,100 Btu/hr(1.2 kW) for every 100 lb/day of chlorine production capacity. • Section 2—Environmental&Safety Conditions mf 2-2 City Co COCess SO-Iritions,Inc, ' _ 10/20/2026 MI CR CLOR Operation&Maintenance Manual 2.2 Hydrogen Vent Piping An important part of any OSHG system is the hydrogen vent piping from the electrolytic cell. This piping removes the produced hydrogen gas from the electrolytic cell to be dispersed to the environment in a safe location. On larger systems,this vent piping may include a dilution air blower system which combines large amounts of air with the produced hydrogen (typically in a 100:1 ratio) in order to ensure that the concentration of hydrogen is well below the lower flammable limit(LFL) of 4%. A 100:1 ratio will reduce the concentration of hydrogen to less than 1%, which is '/a of the LFL. When designing a vent piping systems the following design considerations should be kept in mind: • Ducting should be sized per Process Solutions recommendations or system specifications. The vent stack outlet should be at least 2 feet above the roof line for at least 15-20 feet in all directions. • A general rule of thumb would be to limit the length_(if possible) of the venting system to less than 15 feet for smaller OSHG systems (capacities less than 50 lbs/day) and no longer than 50 feet in length for larger systems. Process Solutions should be consulted in the implementation of venting systems with longer pipe runs. Pipe elbows and other air flow restrictive fittings should be kept to a minimum—typically no more than 6 elbows • Vent outlets should not terminate anywhere where people can pass by or congregate. Additionally,there should be no air inlets,heaters, windows, air conditioners or other sources of ignition within 15 feet of the outlet. • Horizontal vent lines should be kept to a minimum. All horizontal lines should have a minimum upward slope toward the vent outlet of approximately '/a in/ linear.foot. This will prevent any hydrogen from being trapped in the system, and allow for proper drainage. • Do not use the pressure created in the electrolytic cell to transfer the'produced 0.8%hypochlorite to distant tanks. If the hypochlorite storage tank is located further than 15 feet above the generator or more than 100 feet away, Process Solutions recommends that a transfer pump in conjunction with a day tank or transfer vessel be used for pumping the hypochlorite. • Section 2—Environmental&Safeo) Conditions 2-3 City Co upipcess sol tions,Inc, 22 — 39 10/20/2026 MICROCLOR Operation&Maintenance Manual TYPICAL VENT PIPING NINIMIN ARRANGEMENT ILLUSTRATION I INDIUM SLOPE 1/A• PER rUDOXX LINEAL FOOTow _ LW T M r"W rdm 10..Ew K PM=rim 1 61 I O 0 OSHG BLOWER VENT OUTLET TO ATMOSPHERE BLOWER VENT FROM HYPO STORAGE TAMS O 3' IIN NECK VALVE _. _.. _. .. Osm OUTLET PIPE 6' H DRIP LEG OF CLEAR PVC VITH VALVE 2'MIN MIN 2'OF 2X DIAMETER OF MLET P HYPOCHLOtITE NININUN SLOPE STORAGE TANK HYDROGEN DILUTION BLOWER I/+'PER DUCTING & PIPING LINEAL n3OT RECOMMENDATIONS FOR THE MICROCLOR OSHG • When designing venting systems for multiple OSHG systems, it is a preferred practice to provide separate vent systems for each OSHG. Multiple OSHG's can be vented into the same ducting,however it is recommended that Process Solutions be consulted in the proper sizing of ducting for multiple generation systems. • All ventilation duct components to be fabricated of Schedule 80 PVC and pipe fittings. If the PVC will be exposed to sunlight,Process Solutions recommends painting the PVC to prevent UV degradation. • PVC joints should use a PVC primer and gray IPS weld- On 724 CPVC cement (or equivalent) for improved resistance to sodium hypochlorite • Air dilution blowers should be located low-often near ground level and no higher than 2/3 the height of the hypochlorite storage tank. This is to prevent hydrogen gases from being in contact with the blower. A check valve and drip leg for condensation are also recommended in blower installations to reduce the •lL . Section 2—Environmental&Safeo,Conditions 2-4 City Co e1T_cess solutions,Inc, 22 — 140 10/20/2026 MICROC;LOIR Operation&Maintenance Manual corrosion of the blower by limiting off-gases and condensated from contacting the blower components. .• In very cold environments, it may be necessary to use polyethylene piping for the exterior piping, as this is less brittle than PVC in freezing cold environments. Heat tracing should be applied to the exposed areas. • A screened vent cap should be used to terminate the hydrogen vent stack to the atmosphere. Depending upon the location of the installation, this vent cap may need lightning protection. iiL Section 2—Environmental&SafeO,Conditions ns 2-S 0 f"""em City Co ess sot tions,Inc. 22 — 141 10/20/2026 M1CR rLoR Operation&Maintenance Manual 2.3 Sodium Hypochlorite Piping Plastics Compatible material for 0.8% sodium hypochlorite systems include: PVC,Teflon a (PTFE), FRP,polyethylene and KynarOO (PVDF). CPVC can also be used,however has a tendency to become brittle over time when exposed to sodium hypochlorite. Gasket Material Gaskets for use with sodium hypochlorite should be Teflon or Viton material.EPDM gaskets should not be used. Metals Hastelloy C-276 &titanium are the most common compatible metals used with sodium hypochlorite. Gold,platinum,tantalum, &silver are compatible with sodium hypochlorite, however tend to be used only for minor components due to the costs of material. Valves Valves should have seals & O-rings constructed of Teflon or Viton. 0.8% sodium hypochlorite does not need vented valve balls. If there is the possibility that the piping could be used for 12% sodium hypochlorite, it is recommended that the ball valves have a small vent hole drilled through the side of the ball. When turned to the closed position,the hole allows any liquid or gas in the ball to flow freely in and out of the ball. Thus the liquid remains in contact with the upstream side, or it simply vents away f downstream, depending on which direction the valve is i T installed. Without a vent of some sort, sodium hypochlorite would be trapped inside the ball whenever it is in the closed position, and give off gas (outgas).The trapped gas could eventually cause the body of the ball valve to burst as the concentrated sodium hypochlorite degraded and the valve body over-pressurized. Piping Piping for low pressure 0.8% sodium hypochlorite systems are typically Schedule 80 grey PVC (Type I grade 1). Whenever possible use socket solvent welded connections to reduce the possibility of leaking threaded fittings. It is recommended that a high quality CPVC glue such as IPS brand Weld-On 724 CPVC be used. CPVC glue has better resistance to sodium hypochlorite. Piping may need to be heat traced if exposed to freezing temperatures for extended periods of time. •�� Section 2—Environmental&Safety Conditions �S I 2-6 Clty COUII�Pcess sol tions,inc. r Tbzcf°" "22t 1�42 ��e� e� 10/20/2026 MICROam Operation&Maintenance Manual Storage Tanks 0.8% strength sodium hypochlorite falls below the hazardous materials threshold (1.0%) and is typically exempt from EPA (RMP) and HazMat regulations. Consequently, storage tanks do not typically require a double walled storage vessel or a containment system unless specified by local codes. Tanks should be placed on a smooth, clean, debris free concrete pad to prevent damage to the tank bottom. The tank supplier can provide specific instructions about placement and mounting of the tank. Considerations When Installing a Tank The tank should be fastened down with a tie down system that is appropriate for the seismic activity or wind activity that can occur in a particular site. Tanks for sodium hypochlorite are typically polyethylene or FRP construction. Fiberglass tanks are an excellent choice for hypochlorite storage. A well designed tank can last 20-30 years with proper maintenance. When choosing a polyethylene"poly"tank, either linear polyethylene or cross linked polyethylene can be used. Cross=linked polyethylene is recommended for larger tanks-as the tank is less likely to have a split that will propagate and become a large leak. It is suggested that the tank be installed indoors or under a sunshade whenever possible. This will prevent UV damage to the tank and extend the life of the tank, and also reduce degradation effects to the sodium hypochlorite. When it is possible, it is recommended that two storage tanks be installed instead of one storage tank. If there is a problem with a tank due to leaking or damage,there is a back- up tank already on-site. Sodium hypochlorite will off-gas small amounts of hydrogen as the chemical naturally degrades. Locate lighting and electrical components away from tank vents or manholes. A hydrogen alarm may be needed near the sodium hypochlorite tanks. Tanks should be vented with a screen vent pipe or hydrogen dilution blower system depending upon the size of the tank and the recommendations of Process Solutions. Venting of the tanks is needed to prevent damage to the tanks during filling or emptying of the tanks. This will prevent damage due to over-pressurization or vacuum conditions. If a tank will be exposed to freezing conditions,heat tracing of the tank and piping may be necessary. 0.8% sodium hypochlorite has a freezing point that is very close to the freezing point of plain water (32'F or 0° C). On poly tanks, one of the primary locations of failure is the bulkhead fittings located near the base of the tank. This failure can be greatly reduced by the following practices: • Use molded tank fittings whenever possible. *A Section 2—Environmental&Safety Conditions ng, 2-7 City Co efpcess solutions,Inc. 22 — 143 10/20/2026 MICROCLOR Operation&Maintenance Manual • Use"bolt-thru"bulkhead fittings instead of compression fittings for fittings larger than 2". • Do not locate the bulkhead fittings too close to the base. • Recognize that the walls of the tank will expand as the tank is filled particularly near the bottom of the tank. Use flexible tubing (such as reinforced flexible PVC tubing) instead of hard piping connections to the bulkhead fittings to transition to the piping system. If a tank is placed inside of a building, consideration should be given in the placement of the tank and other equipment in the building to allow for ease of tank replacement at a later time. Ensure that there are ladders,manways, or handrails that will allow for access to all serviceable components of the system,including tank level sensors &blowers. Lighting should be adequate for maintenance and operation of the equipment. luo%k All hypochlorite storage tanks should be considered a confined space and may contain hydrogen gas. Never remove a hatch or work on the storage tank until the tank has been purged of hydrogen or other gases and site confined space entry procedures have been followed. • Section 2—Environmental&Safety Conditions ePmumn 6� h - 2-8 City Co efpcess soT tions,Inc. 22 — 144 10/20/2026 MICROCLOR Operatiorr&Maintenance Manual 2.4 Sodium Hypochlorite Incompatibility Chart Do NOT mix Sodium Hypochlorite(bleach)with ANY other chemical unless adequate engineering controls and personal protective equipment(PPE) are in place. Accidental mixing may cause dangerous conditions that could result in injury to personnel and/or damage to property or the environment. Incompatible Material Mixing MAY Result In Acids,Acidic Compounds and Acid Based Cleaning Release of chlorine gas,may occur violently Compounds such as: Alum(aluminum sulfate) Aluminum Chloride Ferrous or Ferric Chloride Ferrous of Ferric Sulfate Chlorinated Solutions of Ferrous Sulfate Hydrochloric Acid(HCL) Sulfuric Acid Hydrofluoric Acid Fluorosilic Acid Phosphoric Acid Brick and Concrete Cleaners Chemicals and Cleaning Compounds containing Fonnation of Explosive Compounds. ammonia such as: _ - Anunonium Hydroxide Release of Chlorine or Other noxious gases. Ammonium chloride Ammonium Silicofluoride Ammonium Sulfate Quaternary Ammonium Salts(Quats Organic Chemicals and Chemical Compounds such Formation of chlorinated organic compounds. as: Solvents and Solvent Based Cleaning Formation of explosive compounds. Compounds Release of chlorine gas,may occur violently. Fuel and Fuel Oils Amines Propane Organic Polymers Ethylene glycol Inseciticides Methanol Metals such as: Release of oxygen gas,generally does not occur Copper violently. Could cause overpressure/rupture of a Nickel closed system. Cobalt Iron Avoid piping and material handling equipment containing stainless steel,aluminum,carbon steel or other corm-non metals Hydrogen Peroxide Release of oxygen gas,may occur violently. Reducing agents such as: Evolution of heat,may cause splashing or boiling. Sodium Sulfite Sodium Bisulfite Sodium Hydrosulfite Sodium Thiosulfate • Section 2-EnWronmental&Safety Conditions n. 2-9 City Copcess solutions,Inc. 22 — 45 10/20/2026 DISTRIBUTION SYSTEM CLASSIFICATION Name: City of Santa Ana Number: 3010038 Engineer: Fand Rizk Date: 02/16/2001 Rev. 03/16/2001 DISTRIBUTION SYSTEM CLASSIFICATION: D5 No. Criteria Assigned Points 1 Pressure Zones Points Three Zones or less 0 0 Four to ten Zones 4 More than ten Zones 6 2 Disinfectants Points No Disinfectant is applied in the distribution system and no more than one 0 type of disinfectant residual is entering the distribution system 8 One single disinfectant or ammonia is applied in the distribution system 5 Multiple disinfectants in the system 8 3 Distribution System Pumps Points No Distribution system Pumps 0 6 Largest single system pump is 50 horsepowers or less 4 Largest single system pump is more than 50 horsepowers 6 4 Distribution System Storage Reservoirs Points No Reservoirs 0 6 One to five reservoirs 4 More than five reservoirs 6 5 Uncovered Distribution System Reservoirs Points j 0 0 One or more uncovered reservoirs or 10 6 Service of Non-potable water to customers Points Any customers also receiving non-potable water services. This does not 0 6 apply to wholesalers if the only customers receiving non-potable water are or served by its retailers. 6 TOTAL 26 Population Served 312,000 Classification D5 City Council 22 — 146 10/2®/gQgf6 TREATMENT FACILITY CLASSIFICATION System Name: Santa Ana, City of System No.: 3010038 Treatment Facility: Nitrate Blending Facility at Bristol Reservoir Capacity (mgd): 7.24 Date Classified: April 22, 2002 Date Revised: July 6, 2004 Engineer: Anthony Nhan Classification Assigned to This Treatment Facility: T3 Criteria For Classification Point Value Calculation 1 Source Water Used by the Facility Groundwater and/or purchased treated water meeting primary and Na'`+ � n secondary drinking water standards, as defined in section 116275 of I {2; 2 the Health and Safety Code Water that includes any surface water or groundwater under the direct 5 influence of surface water 2 Influent Water Median Coliform Density, MPN Less than 1 per 100 mL 1 through 100 per 100 mL 2 0 Greater than 100 through 1,000 per 100 mL 4 Greater than 1,000 through 10,000 per 100 mL 6 Greater than 10,000 per 100 mL 8 3 Maximum Influent Turbidity Level, NTU Less than 15 MOB o f 15 through 100 2 Greater than 100 5 4 Influent Water Nitrate and Nitrite Data Average Less than or equal to the maximum contaminant level (MCL) 0 5 Greater than the MCL53t ,. 5 Influent Water Chemical and Radiological Contaminant Data Less than or equal to the MCL 0 2 Greater than the MCL RE� a '" 5 Times the MCL or greater 5 6 Surface Water Filtration Treatment Conventional, direct, or inline 15 Diatomaceous earth 12 0 Slow sand, membrane, cartridge, or bag filter 8 Backwash recycled as part of process 5 Not applicable IrW 7 Other Treatment for Primary MCL Exceedance The point value for each treatment process utilized by the facility and not included in No. 6 above that is used to reduce the concentration of one or more contaminants for which a primary MCL exists, pursuant to 0 or 10 10 Table 64431-A,Table 64444-A, and Table 4 of section 64443, is 10. Blending is only counted as a treatment process if one of the blended sources exceeds a primary MCL, Br�rv' Ram 4 F�oi�nan City Council 22 — 147 10/20/2026 8 Other Treatment for Secondary MCL Exceedance The point value for each treatment process not included in Nos. 6, or 7 that is used to reduce the concentration of one or more contaminants 0 for which a secondary MCL exists, pursuant to Tables 64449-A and 0 or 3 64449-B, is 3. Blending is only counted as a treatment process if one of the blended sources exceeds a secondary MCL. 9 Corrosion Control or Fluoridation The point value for each treatment process not included in Nos. 6, 7, or 0 or 3 0 8 that is used for corrosion control or fluoridation is 3. (10) Disinfection for Inactivation of Giardia Cysts and Viruses Ozone 10 Chlorine and/or chloramine 10 0 Chlorine dioxide 10 Ultra violet(UV) 7 Not applicable , p0 ,, 11 Disinfection/Oxidation without Inactivation Credit Ozone 5 Chlorine and/or chloramine NEMIROW Chlorine dioxide 5 5 Ultra violet(UV) 3 Other oxidants 5 Not applicable 0 12 Treatment for Physical/Chemical Characteristics The points for any other treatment process that alters the physical or 0 chemical characteristics.of the drinking water and,that was not included 0 or 3 in Nos. 6, 7, 8, 9, 10, or 11 is 3. (13) Facility Capacity The point value for facility flow is 2 per million gallons per day or fraction thereof of maximum permitted treatment facility capacity, up to a maximum of 50 points; except that for facilities utilizing only blending, 16 the point value is based on the flow from the contaminated source and Max. 50 the dilution flow required to meet the MCL(s) specified in Tables 64431- A, 64444-A, 64449-A, 64449-B, and Table 4 of section 64443. TOTAL POINTS 40 Treatment Facility Classification Total Point Class <20 T1 20-39 T2 40-59 T3 60-79 T4 80 or more T5 Bristol Pagc Z aiaronjn City Council 22 — 148 10/20/2026 Exhibit 2 ORDINANCE NO. NS-XXX AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA ANA, CALIFORNIA, ADDING SECTION 39-43 TO ARTICLE II OF CHAPTER 39 OF THE SANTA ANA MUNICIPAL CODE TO ESTABLISH CITY COUNCIL APPROVAL OF CHANGES AFFECTING CITY DRINKING WATER QUALITY STANDARDS AND REGULATIONS WHEREAS, the City of Santa Ana owns and operates a public water system that provides drinking water to residents, businesses and other customers within its service area; and WHEREAS, the City's public water system is subject to applicable federal and state drinking water laws and regulations, including requirements administered by the California State Water Resources Control Board, Division of Drinking Water, as well as the City's Domestic Water Supply Permit and any binding orders issued by regulatory agencies with jurisdiction over the City's water system; and WHEREAS, California Health and Safety Code section 116375 authorizes the State Water Resources Control Board to adopt primary drinking water standards. State law establishes statewide drinking water requirements that public water systems must meet. However, City may establish drinking water standards that are more protective than applicable state or federal minimum requirements, but may not adopt or implement standards that are less protective than mandatory state or federal requirements; and WHEREAS, federal and state drinking water standards and regulations may be adopted, amended, suspended, rescinded, waived or otherwise modified over time. Such changes may increase, decrease or otherwise alter regulatory requirements applicable to the City's water system; and WHEREAS, changes to drinking water standards and regulations may affect public-health protections, treatment requirements, monitoring and reporting, water- system operations, infrastructure planning and costs; and WHEREAS, on June 16, 2026, the City Council approved an item directing staff to draft an ordinance requiring City Council review and approval of any changes to the City's Drinking Water Standards and Regulations; and WHEREAS, the City Council intends this approval requirement to apply to changes that affect the City's drinking water quality standards and regulations, while allowing City staff to comply promptly with mandatory federal or state law, permit requirements and binding regulatory orders; and Ordinance No. NS-XXX City Council 22 — 149 1 / 0 6 WHEREAS, certain requirements imposed by federal or state law, the City's Domestic Water Supply Permit, or a binding regulatory order may become effective there is sufficient time to complete the City Council process. Nothing in this ordinance is intended to authorize, require, or result in any violation of the City's compliance with such requirements; and WHEREAS, the City Council also desires timely public review of proposed federal or state regulatory changes that may affect the City's drinking water standards so that the City may evaluate the potential effects, participate in regulatory proceedings when appropriate and consider whether a more protective local standard is legally permissible. NOW, THEREFORE, the City Council of the City of Santa Ana does hereby ordain as follows: SECTION 1. The recitals above are true, correct and each incorporated herein by reference and adopted as findings by the Santa Ana City Council ("City Council"). SECTION 2. Section 39-43 is hereby added to the Santa Ana Municipal Code to read in full as follows: Sec. 39-43. City Council review and approval of changes to City drinking water quality standards and regulations. (a) Purpose. The purpose of this section is to provide for transparent public review and City Council approval of discretionary changes to the City drinking water quality standards and regulations, whether a proposed change would increase, decrease or otherwise modify the applicable level of protection, while preserving the City's ability to comply fully and without delay with federal and state law, applicable permits, binding regulatory orders, and emergencies affecting public health or water service. (b) Definitions. For purposes of this section, the following definitions shall apply: 1. Applicable requirement means any federal or state law or regulation, permit condition, legally binding directive, compliance schedule, enforcement order or other legally binding requirement applicable to the City's public water system. 2. Change means the adoption, amendment, suspension, rescission, waiver or other modification of a City drinking water standard or regulation. A change does not include a routine operational, maintenance, treatment, engineering, monitoring, testing, reporting, or administrative decision that does not itself adopt, amend, suspend, rescind, waive or otherwise modify a City drinking water standard or regulation. Ordinance No. NS-XXX City Council 22 — 150 1 6/N"2 6 3. City drinking water standard or regulation means any ordinance, resolution, formally adopted policy, rule, or other requirement adopted by the City that establishes a requirement, limitation, performance standard, or objective concerning the quality, treatment, monitoring, testing, reporting, or delivery of drinking water by the City's public water system. (c) City Council approval required. 1. No change to a City drinking water standard or regulation shall be adopted without first being presented to and approved by the City Council, except as provided in subsection (e) for compliance with a mandatory external requirement or subsection (f) for emergency or protective actions. 2. The approval requirement applies whether the proposed change originates with City staff or is necessary to conform to a final federal or state requirement, permit condition, or binding regulatory order; provided, however, that subsection (e) shall govern when compliance is required before City Council approval can reasonably be obtained. 3. For a change within the City's discretion, the City Council may approve, modify or reject the proposed change or direct staff to conduct additional analysis before implementation. No Council action under this subsection may authorize a violation of an applicable requirement. 4. City Council approval may be provided by resolution or through another form of Council action determined appropriate by the City Attorney. (d) Review of proposed federal or state regulatory changes. 1. When a federal or state agency proposes a regulatory change that may reasonably require or result in a change to a City drinking water standard or regulation, the Executive Director of Public Works, or designee, shall present the matter to the City Council when reasonably practicable and sufficiently in advance of the applicable public-comment deadline. 2. If a public-comment deadline does not permit sufficient time to obtain prior City Council direction, the City Manager or Executive Director of Public Works may submit technical comments or other comments within the scope of their existing authority on behalf of the City to meet the applicable deadline. Any such comments submitted shall be reported to the City Council at the next available regular meeting. (e) Final or mandatory external requirements. 1. When a federal or state requirement, applicable permit condition, or binding regulatory order becomes final and requires a change to a City drinking water standard or regulation, the Executive Director of Public Works, or designee, shall present the conforming change to the City Council for approval before the Ordinance No. NS-XXX City Council 22 — 151 1 d/N"2 6 date by which the City's standard must be changed, when reasonably practicable. 2. If a mandatory implementation deadline, permit requirement, regulatory order, public health condition, or need to maintain reliable water service requires action before City Council approval can reasonably be obtained, City staff may take the operational, treatment, monitoring, reporting, notification or other action necessary to comply with the applicable requirement. 3. When City staff acts under paragraph (2), the Executive Director of Public Works, or designee, shall present any necessary conforming change to a City drinking water standard or regulation to the City Council for approval as soon as reasonably practicable. Staff shall also report the action already taken to maintain compliance. (f) Emergency and protective actions. Nothing in this section shall prevent the City Manager, the Executive Director of Public Works or their authorized designees from temporarily suspending, modifying, or deviating from a City drinking water standard or regulation when reasonably necessary to: 1. Protect public health; 2. Respond to a water-quality condition or emergency; 3. Prevent or correct a violation of an applicable requirement; 4. Comply with the City's Domestic Water Supply Permit or a binding regulatory order; or 5. Maintain reliable water service. Any temporary suspension, modification, or deviation under this subsection shall remain in effect only for the duration reasonably necessary to address the emergency or comply with the applicable requirement. Any such action shall be presented to City Council as soon as reasonably practicable, and any resulting change to a City drinking water standard or regulation shall be presented to the City Council for approval. (g) Preservation of operational authority. Nothing in this section shall be construed to limit the authority otherwise provided by law, permit, ordinance, resolution, policy, or City Council action to City officers, employees, operators, engineers, or other authorized personnel to operate, maintain, monitor, test, treat, or manage the City's public water system, provided that such actions do not themselves constitute a change to a City drinking water standard or regulation. SECTION 3. Environmental Review. Ordinance No. NS-XXX City Council 22 — 152 1 / 0 6 The City Council finds and determines, in accordance with the California Environmental Quality Act (CEQA) and the CEQA Guidelines, that the introduction and adoption of this ordinance is not subject to CEQA because the activity will not result in a direct or reasonably foreseeable indirect physical change in the environment (Title 14 California Code of Regulations (CCR) § 15060(c)(2) and the activity is not a project as defined in Section 15378 of the CEQA Guidelines because the ordinance is an organization administrative activity which establishes a process for City Council review and approval of discretionary and mandatory changes to City drinking water standards and regulations and does not itself authorize or require any physical alteration, construction, expansion, or other physical change to the City's public water system or the environment. (14 CCR §§ 15060(c)(3) and 15378(b)(5).) Additionally, the ordinance is exempt from CEQA because it can be seen with certainty that there is no possibility that the adoption of this ordinance may have a significant effect on the environment. (14 CCR § 15061(b)(3).) SECTION 4. Severability. If any section, subsection, sentence, clause, phase, or portion of this Ordinance is for any reason held to be invalid or unconstitutional by the decision of any court of competent jurisdiction, such decision shall not affect the validity of the remaining portions of this Ordinance. The City Council hereby declares that it would have adopted this Ordinance, and each section, subsection, subdivision, sentence, clause, phrase or portion thereof, irrespective of the fact that any one or more sections, subsections, subdivisions, sentences, clauses, phrases or portions might subsequently be declared invalid or unconstitutional. SECTION 5. Effective Date. This Ordinance shall become effective thirty (30) days after its adoption. SECTION 6. Publication. The City Clerk shall certify the adoption of this Ordinance and shall cause the same to be posted as required by law. Ordinance No. NS-XXX City Council 22 — 153 1 / 0 6 ADOPTED this day of 12026. Valerie Amezcua Mayor APPROVED AS TO FORM: Sonia R. Carvalho, City Attorney 'e Nellesen Assistant City Attorney AYES: Councilmembers: NOES: Councilmembers: ABSTAIN: Councilmembers: NOT PRESENT: Councilmembers: CERTIFICATE OF ATTESTATION AND ORIGINALITY I, Jennifer L. Hall, City Clerk, do hereby attest to and certify the attached Ordinance No. NS-XXXX to be the original ordinance adopted by the City Council of the City of Santa Ana on 12026. Date: City Clerk City of Santa Ana Ordinance No. NS-XXX City Council 22 — 154 1 / 0 6