Loading...
HomeMy WebLinkAbout25C - AGMT - CATCH BASIN PROJREQUEST FOR COUNCIL ACTION CITY COUNCIL MEETING DATE: NOVEMBER 28, 2011 TITLE: AGREEMENT WITH UNITED STORM WATER INC. AND WEST COAST STORM INC. FOR CATCH BASIN SCREEN INSTALLATION PROJECTS ALE?ITY MANAGER RECOMMENDED ACTION CLERK OF COUNCIL USE ONLY: APPROVED ? As Recommended ? As Amended ? Ordinance on 15' Reading ? Ordinance on 2"d Reading ? Implementing Resolution ? Set Public Hearing For_ CONTINUED TO FILE NUMBER Authorize the City Manager and the Clerk of the Council to execute the attached agreements with United Stormwater, Inc. and West Coast Storm, Inc., each in an amount not to exceed $110,000 for catch basin screen installation projects, subject to nonsubstantive changes approved by the City Manager and City Attorney. DISCUSSION The City has applied for and been awarded funds from the OCTA Measure M2 Environmental Clean Up - Tier 1 Water Quality Grant Funding Program (ECPF) for two catch basin screen installation projects. The program designates funds for projects with a transportation nexus that reduces storm water pollution related to transportation-related runoff. OCTA, in coordination with the County of Orange, has prequalified contractors to provide purchase and installation services for automatic retractable screens, connector pipe screen full capture systems and catch basin inserts under the ECPF. Based on the qualifications and experience with storm water treatment technology, United Stormwater, Inc. and West Coast Storm, Inc. are approved by OCTA and the County to provide the catch basin installation services proposed in the City's successful grant application. Five contractors submitted proposals, and three were prequalified for the work to be funded by the ECPF program. Based on cost and experience, staff selected two of the three contractors to construct the approved catch basin screen installation projects. 25C-1 Agreement with United Stormwater Inc. and West Coast Storm Inc. November 28, 2011 Page 2 ENVIRONMENTAL IMPACT This project will help to protect the environment by preventing trash and debris from entering the city catch basins and eventually emptying into the ocean. FISCAL IMPACT Funds are available in the Measure M2 Street Construction Fund (accounting unit 03217662- 66220). v Raul Godinez II Executive Direct Public Works Agency APPROVED AS TO FUNDS AND ACCOUNTS: Francisco Gutierrez Executive Director Finance & Management Services Agency RG:JP Exhibit: 1. Agreement 25C-2 Account (3u machons To W, CSV Export 3,. ,stn=s,, _ ?ra.,?p... ?.,xRendstnres J J J Page 1 of 1 11/22/2011 Next Page ---?- _... Remaimng Tr,ai r:xs5 23,4,0M https://Iawson.cosa.private/lawson/portal/forms/forMZ§. o* 4rKN=GL94.2& PDL=PROD& CONT AGREEMENT FOR INSTALLATION OF CATCH BASIN SCREENS THIS AGREEMENT, made and entered into this 28'h day of November, 2011, by and between United Stormwater, Inc., a California corporation (hereinafter referred to as "CONTRACTOR" ) and the City of Santa Ana, a charter city and municipal corporation organized and existing under the Constitution and laws of the State of California (hereinafter referred to as ("CITY"). RECITALS: A. CITY desires to enter into a contract for the provision and installation of "Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Systems and Catch Basin Inserts" (hereinafter referred to as "Catch Basin Screens") in the Wintersburg Channel located in the City of Santa Ana; and B. OCTA has awarded funding for the Project through its Measure M2 Environmental Clean Up- Tier I Water Quality Grant Funding (ECPF) Program for the installation of Catch Basin Screens in the Wintersburg Channel ("the Project"); and C. The County of Orange, entered into Agreement MA-080-11011795 by which Contractor has agreed to assume all responsibilities and obligations inherent with the procurement and installation of Catch Basin Screens through the ECPF Program; and D. Contractor has agreed to procure and install Catch Basin Screens for the Project in conformance with the terms and conditions set forth in Orange CountyAgreement MA-080-11011795, and as further agreed herein. WHEREFORE, for and in consideration of the respective and mutual covenants and promises hereinafter contained and made, and subject to all the terms and conditions hereof, the parties hereto do hereby agree as follows: 1. SCOPE OF WORK Contractor agrees to provide all supervision, technical personnel, labor, materials, machinery, tools, equipment and services, security measures to protect its equipment and materials, as well as necessary permits to procure and install United Stormwater's Drain PacTm Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Systems and Catch Basin Inserts, as set forth in Exhibit A, attached hereto. Said Catch Basin Screens will be installed in the Wintersburg Channel, as shown on the map attached hereto as in Exhibit A-l. All attachments to this Agreement are hereby incorporated by reference. The Contractor shall execute the work in accordance with the safety provisions of applicable laws and the building construction codes. Contractor shall keep the Property clean and orderly during the course of the work and remove all debris upon completion of the work. The Contractor shall be responsible for any damages to property and/or injuries to persons (on or off site) as a result of their execution of the work required by the Contract. 2. REPRESENTATIVES AND NOTICE For the purposes of implementing this Agreement, the representative of the City shall be the Executive Director of the Public Works Agency or his designated representative. The representative of 25C-4 the Contractor shall be . Except as may be otherwise stated, such representatives shall have the authority to act on behalf of their respective parties in carrying out the terms of this Agreement. Any notice or instrument required to be given or delivered to either party to this Agreement may be remitted by personal delivery or by depositing the same in the United States mail, postage prepaid, addressed to: If to the CITY: City of Santa Ana Public Works Agency - Design Engineering P.O. Box 1988, M-36 Santa Ana, CA 92702-1988 If to the CONTRACTOR: United Stormwater, Inc. 1400 E. Valley Blvd. City of Industry, CA 91746 Any notice of a change of address shall be delivered in the same manner as any other notice provided herein. Notice by mail shall be effective three days after mailing by the above-described procedure. 3. COMPENSATION A. City agrees to pay, and Contractor agrees to except as total payment for any and all services under this Agreement, the rates and charges attached hereto as Exhibit B. The total amount to be paid for procurement and installation of all Catch Basin Screens shall not exceed One-Hundred Thousand Dollars ($100,000). B. Payment due Contractor for completed and accepted work shall be paid within thirty (30) calendar days after the City's acceptance of the work, receipt of Contractor's invoice and satisfactory releases of liens or claims for liens by Contractor, subcontractors, laborers, and material suppliers for completed work or installed materials. C. Payments may be withheld on account of defective work not remedied, claims filed, failure of Contractor to make payments properly to subcontractors or for labor, materials, or equipment, damages by another Contractor, or unsatisfactory prosecution of the work by Contractor, as determined by the City. 4. STANDARD OF PERFORMANCE In undertaking the performance of this Agreement, Contractor represents that it is proficient in the field of storm water catch basin installation. Work performed by the Contractor under this Agreement will be accomplished in compliance with such standards as may reasonably be expected from a contracting firm in that field or trade. Contractor shall perform the work in a professional manner with quality workmanship. 5. CORRECTION AND DEFECTS Contractor shall correct any work that fails to conform to the requirements of this Agreement or any documents pursuant hereto, where said failure to conform appears during the progress of the work. Contractor shall remedy any defects due to faulty materials, equipment or workmanship which appear within a period of one (1) year from the date of recording of the Notice of Completion by the City, or within such longer period of time as may be prescribed by law or by the terms of any applicable special guarantee required by this Agreement or any document pursuant thereto. 2 25C-5 6. GUARANTEE Contractor guarantees the work performed for a period of one (1) year from the date of final acceptance of all the work required by this Agreement. Contractor guarantees all materials to be as specified and all work to be completed in a professional manner according to standard practice. Unless otherwise specified, all materials shall be new. Contractor shall leave the work in a finished condition as determined by acceptable building standards and to the satisfaction of the City. 7. TIME FOR COMPLETION/ TERM OF AGREEMENT Contractor shall commence work on the Project upon City's Notice to Proceed, and shall complete the project in a timely manner. The Term of this Agreement is from the date first stated above through June 30, 2012. 8. COMPLIANCE WITH ENVIRONMENTAL LAWS. Contractor agrees to comply with all applicable laws and governmental regulations including, without limitation, all applicable federal, state, and local laws pertaining to air and water quality, hazardous waste, waste disposal, and other environmental matters, including, but not limited to, the Clean Water, Clean Air, Federal Water Pollution Control, Solid Waste Disposal, Resource Conservation Recovery and Comprehensive Environmental Response Compensation and Liability Acts, and the California Environment Quality Act, and all applicable federal, state, and local agencies. 9. INSPECTIONS City shall have the right to inspect any work performed hereunder to ensure that the work is being and has been performed in accordance with the applicable federal, state and/or local requirements and this Agreement. Contractor agrees that all work found by such inspections not to conform to the applicable requirements shall be corrected by Contractor, and City shall have the right to withhold payment to Contractor until it is so corrected. 10. CHANGE ORDERS Any changes or deviations from Bid/Proposal, Specification, and approved Project Drawings, or the terms of this Agreement shall be effective only upon written consent of City and the Contractor. All change orders will specifically describe the work and/or changes, the new agreement price and time for completion. 11. INDEMNIFICATION Contractor agrees to indemnify, defend and hold harmless the City of Santa Ana, its officers, agents and employees from and against any and all loss or damage to property and from all injuries or death of any person or persons in the performance of the work under this Agreement. Contractor agrees to indemnify, defend and hold harmless the City of Santa Ana, its officers, agents and employees from and against any and all suits, actions or proceedings of any kind or nature arising out of the acts or omissions of employees or agents of Contractor or its subcontractors. 3 25C-6 12. INSURANCE With respect to performance of work under this Agreement, Contractor shall maintain and shall require its subcontractors to maintain insurance as described below: (1) Workers' compensation insurance with statutory limits, and employer's liability insurance with limits of not less than $1,000,000 per accident. (2) Commercial general liability insurance or equivalent form, with a combined single limit of not less than $1,000,000 per occurrence. Such insurance shall name Orange County and the City of Santa Ana and their officers, agents and employees as Additional Insured. (3) Business automobile liability insurance, or equivalent form, with a combined single limit of not less than $1,000,000 per occurrence. Such insurance shall include coverage for owned, hired and non-owned automobiles. All insurance coverages required pursuant to this section shall be primary and not contributory with respect to insurance or self-insurance programs maintained by Orange County and/or City; contain standard separation of insured provisions and provide waiver of subrogation clauses. Contractor shall furnish properly executed certificates of insurance and Additional Insured Endorsements to City prior to the commencement of work under this Agreement. Such certificates shall clearly evidence all coverage required above and provide that such insurance shall not be materially changed or terminated except on thirty (30) days prior written notice to City. Contractor shall maintain such insurance from the time work first commences until completion of the work under this Agreement, and replace such certificates for policies expiring prior to completion of work under this Agreement. 13. ASSIGNMENT Contractor shall not assign any rights under this Agreement except upon prior written authorization of City provided that claims or money due or to become due from City under this Agreement may be assigned to a bank, trust company, financial institution or to a trustee in bankruptcy without such approval. Notice of any such assignment or transfer shall be promptly furnished to City. Contractor shall not subcontract any of the services required by this Agreement without written approval of City. Contractor shall not delegate any authority or responsibility that would in any way purport to relieve it of any obligation imposed by this Agreement. 14. CONFLICT OF INTEREST Contractor covenants that it is an independent contractor and not an employee of the City and that its personnel, employees and subcontractors are not employees of the City. Contractor presently has no interest, and shall not have any interest, direct or indirect, which would conflict in any manner with the performance of the work under this Agreement. 15. UNAVOIDABLE DELAYS AND DEFAULTS The time of completion of this Agreement shall be extended by the number of calendar days which Contractor is prevented from performing work as a result of. inclement weather, acts of City not contemplated by this Agreement, the unavailability of workers or materials due to strikes, accident, acts of God, fire, unusual delays in transportation, unavoidable casualties, causes beyond Contractor's control, or any cause which the City may determine justifies the delay. The Contractor shall not be entitled to an extension in the number of calendar days for completion, unless, within five (5) days from the beginning of such delay, it notifies the City in writing of the causes of the delay, which causes must be acceptable to the City. 4 25C-7 16. JURISDICTION/VENUE This Agreement has been executed and delivered in the State of California and the validity, interpretation, performance, and enforcement of any of the clauses of this Agreement shall be determined and governed by the laws of the State of California. Both parties further agree that Orange County, California, shall be the venue for any action or proceeding that may be brought or arise out of, in connection with or by reason of this Agreement. 17. ATTORNEY'S FEES Should any litigation be commenced between the parties to this Agreement concerning the work which is the subject of this Agreement, any provision of this Agreement, or the rights and obligations of either in relation thereto, each party shall be responsible for its own attorney's fees and costs. 18. TIME OF ESSENCE Time is of the essence in performance of this Agreement. 19. EXCLUSIVITY OF AGREEMENT This Agreement supersedes any and all other agreements, either oral or in writing, between the parties hereto with respect to hiring of Contractor by City, and contains all the covenants and conditions between the parties with respect to such employment in any manner whatsoever. Each party to this Agreement, acknowledges that no representations, inducements, promises, or agreement, orally or otherwise, have been made by any party, or anyone acting on behalf of any party, which are not embodied herein, and that any other agreement or amendment to this Agreement shall be effective only if executed in writing and signed by City and Contractor. 21. MISCELLANEOUS PROVISIONS a. Each undersigned represents and warrants that its signature hereinbelow has the power, authority and right to bind their respective parties to each of the terms of this Agreement, and shall indemnify City fully, including reasonable costs and attorney's fees, for any injuries or damages to City in the event that such authority or power is not, in fact, held by the signatory or is withdrawn. b. All Exhibits referenced herein and attached hereto shall be incorporated as if fully set forth in the body of this Agreement. /// 5 25C-8 IN WITNESS WHEREOF, the parties hereto have executed this Construction Agreement on the date and year first above written. ATTEST: Maria D. Huizar Clerk of the Council Approved as to form: By: Laura Sheedy Assistant City Attorney CITY OF SANTA ANA Paul M. Walters Interim City Manager UNITED STORMWATER, INC. (NAME) (Title) Tax ID# Recommended for Approval: Raul Godinez, It Executive Director Public Works Agency 6 25C-9 EQUIPMENT DESIGN & SPECIFICATIONS REPORT: DRAINPACTm CATCH BASIN INSERT Description/Design/Engineering Full Trash Capture United Storm Water's DralnPacT"' meets the full trash capture definition of the RFP as it is capable of trapping all particles larger than 5 mm in size. Equipment & Design Elements United's DrainPacTm is a treatment control BMP product that captures and treats urban runoff before it enters the storm drain system (see attached Technical Drawings. This multi-layer filtration devise Is installed in drop inlets or curb inlets in a manner that does not interfere with lateral line water flow. General specifications of this product are as follows: • Frame assembly will be constructed from 12-gauge 304 stainless steel • Filter liner will be fabricated from a combination of 4 oz non-woven polypropylene filter cloth and PVC mesh • Support basket will be constructed from a high density polymer rated at 850 Ib/sq It This product is custom made in-house to fit any shape or size of catch basin utilizing single or multiple units as required. The smallest workable catch basins for this product would be 6" x 6. The largest size of a single DrainPacTm unit would be 48" x 48" for drop inlets and 82" x 12" for curb inlets. Catch basins larger than these standard sizes would be fitted with multiple units. Installation Specifications The DrainPacT"' could be used in conjunction with a CleanScreen"A Automatic Retractable Screen (ARS) and/or Connector Pipe Screen (CPS) for added effectiveness based on the level of trash and debris that commonly accumulates at the site. Field inspections of catch basins will determine if this product is appropriate for each respective storm drain. For drop inlets the product will be gravity held in place and will rest on the existing catch basin grate shelf. For curb inlets the product will be mounted to the forward wall of the catch basin below the flow line. Materials The DrainPacTM is constructed from non-corrosive materials with the frame and mounting brackets made from stainless steel; the filter liner is composed of PVC mesh (sides only) for overflow bypass, and non-woven polypropylene (bottom only) for treating petroleum hydrocarbons; and the support basket Is made from a high density biaxial geogrid material. See attached Technical Drawings for drop inlet and curb inlet configurations and material specifications. Flow Rating Site appropriate maintenance frequencies of this product will help to ensure effective and trouble free functioning of this product. Insufficient inspection and/or cleaning frequencies that allow an excess amount of material to accumulate in the filter liner can significantly affect the flow rate of water through the product. See Filter Testing Report for observations regarding head loss and Flow Rate Testing and Flow Rate Capacity reports for additional data. Estimated Design Life Design life of the DrainPacTAI is dependent on the flows to the site. Average life of a properly maintained unit is three to five years for the filter liner before requiring liner change-out, and the stainless steel frame it reusable for liner replacement which is generally only required due to mishandling/abuse of the product. p. 3 25C-10 EXHIB11" A Performance Effectiveness Targeted Pollutants This product has demonstrated both in the field and in the laboratory to be an effective structural treatment control BMP for capturing trash, sediment, gross solids, oil and grease, and total metals. Recent testing of the DrainPacTm was conducted by California Polytechnic State University San Luis Obispo resulted in 83% to 91% removal efficiency of fine suspended solids with the best removal observed at lower flow rates, and oil and grease removal efficiency varied from 40% to 80% under the test conditions. Higher rates of oil and grease removal can be achieved by adding an absorbent sock around the periphery of the products frame (optional). See attached Filter Testing Report for additional information. Trash Capture & Storage Capacity A DrainPacTm has a trash capture and storage capacity equivalent to the area of each unit. For drop inlets the product will cover the entire length and width of the drain inlet point and standard filter depths are 12" yet can/will be fabricated shallower to prevent the device from obstructing the outlet pipe of the catch basin. For curb inlets the product will be fabricated to the length of the curb inlet opening with 12" wide by 12' deep standard dimensions. Wider and/or shallower devices will be fabricated if/as required based on catch basin configuration. Overflow or Bypass Flow Capacity Drop inlet configurations of the DrainPacTm are designed with a center overflow bypass port to prevent flooding in the event that a unit is full of trash and is no longer filtering. Curb inlet configurations of this product do not require any type of special overflow bypass feature. If a unit is full of trash and Is no longer filtering water entering the catch basin will merely flow over the 12" wide device into the catch basin. Maximum Overflow or Bypass Flow Capacity The overflow bypass features of the DrainPacT'" described have been proven in the field to withstand a 10-year storm event without causing flooding. Siting, Operational & Maintenance Installation Process Before the start of installation United's Project Manager will coordinate with the County's Project Manager to discuss the proposed installation schedule by service zones. For work performed in areas that encroach on traffic right-of-way, an encroachment permit will be obtained from the appropriate entity and United will develop a written and approved traffic plan. When proposed work zones have been accepted United will install DrainPacsT"' in the designated storm drains. Devices installed in drop inlets will be gravity held in place and will rest on the existing catch basin grate shelf. For this configuration Installation will require United's Service Staff to remove the traffic grate using a 'traffic grate puller" tool and will require approximately five minutes to install each device. Devices installed in curb inlets will be mounted to the forward wall of the catch basin approximately 4' below the flow line or as required based on catch basin design and/or other Storm Water Devices that may be installed in the same catch basin. This configuration will require drilling of the interior of the catch basin and Installation of support/mounting brackets (see attached Technical Drawing) and will require approximately fifteen minutes to install each device. Site Specific Measurements The County would have to provide United with storm drain maps, inlet location where the product is proposed for installation, and approximate lengths and widths of drop inlet openings and lengths of curb inlet openings in order to provide Entities with cost estimates. Devices would thereafter be custom made to fit each respective storm drain based on measurements taken by United's Service Staff. This device could be used in conjunction with a CleanScreen"m ARS and/or CPS for added effectiveness based on the level of trash and debris that commonly p. 4 25C-11 accumulates at the site. Field inspections of catch basins will determine if this product is appropriate for each respective storm drain. Regulatory Permits Required for Installation No regulatory permits are required for the installation of this product. Maintenance Requirements For best performance of the DrainPac'm United Storm Water recommends cleaning by means of industrial vacuum (usually does not require confined space entry) once during the dry season (June-September) and as often as monthly during the wet season (October-May) for effective filtration and to prevent the possibility of flooding. Average number of cleanings is three to four per year. Cleaning is particularly important prior to the wet season and after the first storm event of 3/4° of rain to prevent the possibility of flooding. Actual scheduling will be based on United recommendations and customer approval based on county stormwater management ordinances and the storm drain flows and loads subjected to the site. Per the local Stormwater Management and Discharge Control Ordinance, BMPs at manned facilities must be inspected by the discharger before and following predicted rain events, and BMPs at unmanned facilities must be inspected by the discharger at least once during the rainy season and at least once between each rainy season. For best performance of the DratnPacTM United Storm Water recommends inspections as often as once during the dry season (June-September) and in the wet season (October-May) between or during scheduled cleaning events (depending on actual established schedule). Average number of separate inspections Is three per year. Actual scheduling will be based on United recommendations and customer approval based on county stormwater management ordinances and the storm drain flows and loads subjected to the site. Inspection services will ensure that the product is functioning property and will aid in establishing/changing cleaning schedules accordingly. Any items in need of repair/replacement should be performed as soon as it is safe to do so. If failure of the product indicates that it is inappropriate or inadequate to the circumstances, the product must be modified or upgraded to prevent any further failure in the same or similar circumstances. Durability The DrainPacTm is constructed from high quality materials that can withstand normal wear and tear. Any damage that may be caused by fire, sharp objects, vandalism, or other forms of product mistreatment can be repaired by replacing the filter liner and/or support basket as needed utilizing the original frame. The durability of this product will in no way be affected by external factors such as street sweeping and car parking. United Storm Water is not aware of any incidents of vandalism of the product and may be due in part to the need of special tools for removing traffic grates and/or manhole covers in order to access the product. Replacement Parts & Life Expectancy Any damage that may be caused by fire, sharp objects, vandalism, or other forms of product mistreatment can be repaired by replacing the filter liner and/or support basket as needed utilizing the original frame. Not only are our standard rates for new filters economical, yet filter replacements (filter liner and support basket material) that may be required due to normal wear and tare can be provided at 50% of the cost of a same size new DrainPac7m. No other replacement parts are required. Life expectancy of the DrainPacTm is dependent on the flows to the site. Average life of a property maintained unit is three to five years for the filter liner before requiring liner change-out, and the stainless steel frame it reusable for liner replacement which is generally only required due to mishandling/abuse of the product. Warranty Coverage United Storm Water agrees to repair and or replace the frame assembly of this product at no cost to the purchaser for a period of ten (10) years from the date of delivery should failure occur during normal use. The purchaser of this product must be aware that the filter cloth and support basket may become damaged or tom due to retention of items such as sharp objects, corrosives, or enflamed items. Such damage falls outside of the coverage of this p. 5 25C-12 warranty yet may be replaced at a discounted rate to the purchaser. See attached DrainPacT"" Warranty. Aesthetics & Safety For both drop inlet and curb inlet configurations the DralnPacTM is out of sight and not easily visible by pedestrians. No part of an installed device can come in contact with a pedestrian and is considered "safe". Uniqueness of Device The DrainPacTM is unique in that it is both versatile and economical. All products are custom made to fit any shape or size of catch basin and United Storm Water will design filter configurations for special/uncommon applications. The standard filter cloth used for this product is 4.0 oztsq yd, yet heavier fabric weights are available upon request. This product is also easy to clean and does not necessarily require the use of additional media for absorbing petroleum hydrocarbons (depending on site conditions), yet absorbent sock material can be easily added to the frame as an option. Vendor's Installation Background United Storm Water has been manufacturing custom-made DrainPacsTM In-house using United employees since 1999. We have the equipment, facility, and manpower necessary for providing eligible Entities within Orange County with this product and have experience in working on projects of a similar type and scale as the scope of work of this RFP. United employs a team of competent manufacturing personnel who are experienced in interpreting technical drawings, machining, and welding. These individuals are not only quality conscious in their work, but also offer insight and practical know-how that contributes to improved functionality and streamlined design of our products. United's Service Staff performs storm drain cleaning and maintenance services on a daily basis and have successfully cleaned and installed thousands of BMPs yearly for various private and government entities throughout California. Our highly experienced, professional service staff have received in-class and in-the-field training regarding the environmental regulations that govern our industry and are trained and medically monitored in accordance with O.S.H.A. Title 29 CFR 1910.120 to conduct tasks involving storm drain maintenance and the handling of or exposure to hazardous materials, substances, or waste including: • 40-Hour HAZWOPER Training & 8-Hour Annual Refresher Courses • Traffic Control Training Per Caltrans Chapter 8 Standards • Confined Space Entry Training • Confined Space Rescue Training • DOT HM-126F, HM-180 & HM-181 • Bloodborne Pathogens Training • Medical Surveillance Program • O.M.V. & D.O.T. Drug & Driving Record Programs • CPR & First Aid Training • LiveScan (Required by Transportation Security Administration) p. 6 25C-13 .................. .tj ?...... ............ ....._.. i,........... t t ?, • LA . f ----- -- ----- - , y --_ t1 ? S:.v a if t Tl .E it /\}J 1 r = - si C- 25C-14 Estimated Ca pital Costs Item # Description Unit Quantity Unit Price Amount 1 ARS & CPS and Catch Basin Inserts (opt. 6) United Stot <4' 5 $ 897 S 4,487 2 ARS & CPS and Catch Basin Inserts (opt, 6) United Stot 4.1'-6' 7 S 1,343 S 9,399 3 ARS & CPS and Catch Basin Inserts (opt. 6) United Stot 6'-10' 35 $ 1,450 S 50,754 4 ARS & CPS and Catch Basin Inserts (opt. 6) United Stot 10.1'-16' 15 $ 1,794 S 26,908 5 ARS & CPS and Catch Basin Inserts (opt. 6) United Stoi > 16' 3 S 2,344 $ 7,031 S - $ - S $ - Total Catch Basins 65 Subtotal: 598,580 Estimated Installation Costs Item # Description Unit Quantity Unit Price Amount S - $ - S - $ - $ - $ - S - S - S $ - S $ S $ - Subtotal: SO Other Costs Item # Description Hour dollars/hour Amount S S - Catch Basin Inspections by City Staff 227.5 S 51 S 11,575 65 catch basins at 3x / year for 10 years S S (assuming 7 minutes per inspection) S - S - 3x I year is dependent on storm events S S - EA Dollam/year total / 10•yr Contracted BMP Cleaning and Maintenance 65 S 70.00 S 45,500 65 catch basins at min. 2x/yr. for 10 years. S - $ - 2x / year is dependent on storm events Subtotal: 557,075 'TOTAL PROJECT COST $155,655 EXHIBIT Page8 25C-15 AGREEMENT FOR INSTALLATION OF CATCH BASIN SCREENS THIS AGREEMENT, made and entered into this 28`h day of November, 2011, by and between West Coast Storm, Inc., a California corporation (hereinafter referred to as "CONTRACTOR" ) and the City of Santa Ana, a charter city and municipal corporation organized and existing under the Constitution and laws of the State of California (hereinafter referred to as ("CITY"). RECITALS: A. CITY desires to enter into a contract for the provision and installation of "Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Systems and Catch Basin Inserts" (hereinafter referred to as "Catch Basin Screens") in the Downtown Business District/ Civic Center located in the City of Santa Ana; and B. OCTA has awarded funding for the Project through its Measure M2 Environmental Clean Up- Tier 1 Water Quality Grant Funding (ECPF) Program for the installation of Catch Basin Screens in the Wintersburg Channel ("the Project"); and C. The County of Orange, entered into Agreement MA-080-11011795 by which Contractor has agreed to assume all responsibilities and obligations inherent with the procurement and installation of Catch Basin Screens through the ECPF Program; and D. Contractor has agreed to procure and install Catch Basin Screens for the Project in conformance with the terms and conditions set forth in Orange CountyAgreement MA-080-11011795, and as further agreed herein. WHEREFORE, for and in consideration of the respective and mutual covenants and promises hereinafter contained and made, and subject to all the terms and conditions hereof, the parties hereto do hereby agree as follows: 1. SCOPE OF WORK Contractor agrees to provide all supervision, technical personnel, labor, materials, machinery, tools, equipment and services, security measures to protect its equipment and materials, as well as necessary permits to procure and install Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Systems and Catch Basin Inserts, as set forth in Exhibit A, attached hereto. Said Catch Basin Screens will be installed in the Downtown Business District / Civic Center, as shown on the map attached hereto as in Exhibit A-1. All attachments to this Agreement are hereby incorporated by reference. The Contractor shall execute the work in accordance with the safety provisions of applicable laws and the building construction codes. Contractor shall keep the Property clean and orderly during the course of the work and remove all debris upon completion of the work. The Contractor shall be responsible for any damages to property and/or injuries to persons (on or off site) as a result of their execution of the work required by the Contract. 2. REPRESENTATIVES AND NOTICE For the purposes of implementing this Agreement, the representative of the City shall be the Executive Director of the Public Works Agency or his designated representative. The representative of 25C-16 the Contractor shall be . Except as may be otherwise stated, such representatives shall have the authority to act on behalf of their respective parties in carrying out the terms of this Agreement. Any notice or instrument required to be given or delivered to either party to this Agreement may be remitted by personal delivery or by depositing the same in the United States mail, postage prepaid, addressed to: If to the CITY: City of Santa Ana Public Works Agency - Design Engineering P.O. Box 1988, M-36 Santa Ana, CA 92702-1988 If to the CONTRACTOR: West Coast Storm, Inc. 654 South Lincoln Ave. San Bernardino, CA 92408 Any notice of a change of address shall be delivered in the same manner as any other notice provided herein. Notice by mail shall be effective three days after mailing by the above-described procedure. 3. COMPENSATION A. City agrees to pay, and Contractor agrees to except as total payment for any and all services under this Agreement, the rates and charges attached hereto as Exhibit B. The total amount to be paid for procurement and installation of all Catch Basin Screens shall not exceed One-Hundred Thousand Dollars ($100,000). B. Payment due Contractor for completed and accepted work shall be paid within thirty (30) calendar days after the City's acceptance of the work, receipt of Contractor's invoice and satisfactory releases of liens or claims for liens by Contractor, subcontractors, laborers, and material suppliers for completed work or installed materials. C. Payments may be withheld on account of defective work not remedied, claims filed, failure of Contractor to make payments properly to subcontractors or for labor, materials, or equipment, damages by another Contractor, or unsatisfactory prosecution of the work by Contractor, as determined by the City. 4. STANDARD OF PERFORMANCE In undertaking the performance of this Agreement, Contractor represents that it is proficient in the field of storm water catch basin installation. Work performed by the Contractor under this Agreement will be accomplished in compliance with such standards as may reasonably be expected from a contracting firm in that field or trade. Contractor shall perform the work in a professional manner with quality workmanship. 5. CORRECTION AND DEFECTS Contractor shall correct any work that fails to conform to the requirements of this Agreement or any documents pursuant hereto, where said failure to conform appears during the progress of the work. Contractor shall remedy any defects due to faulty materials, equipment or workmanship which appear within a period of one (1) year from the date of recording of the Notice of Completion by the City, or within such longer period of time as may be prescribed by law or by the terms of any applicable special guarantee required by this Agreement or any document pursuant thereto. 2 25C-17 6. GUARANTEE Contractor guarantees the work performed for a period of one (1) year from the date of final acceptance of all the work required by this Agreement. Contractor guarantees all materials to be as specified and all work to be completed in a professional manner according to standard practice. Unless otherwise specified, all materials shall be new. Contractor shall leave the work in a finished condition as determined by acceptable building standards and to the satisfaction of the City. 7. TIME FOR COMPLETION/ TERM OF AGREEMENT Contractor shall commence work on the Project upon City's Notice to Proceed, and shall complete the project in a timely manner. The Term of this Agreement is from the date first stated above through June 30, 2012. 8. COMPLIANCE WITH ENVIRONMENTAL LAWS. Contractor agrees to comply with all applicable laws and governmental regulations including, without limitation, all applicable federal, state, and local laws pertaining to air and water quality, hazardous waste, waste disposal, and other environmental matters, including, but not limited to, the Clean Water, Clean Air, Federal Water Pollution Control, Solid Waste Disposal, Resource Conservation Recovery and Comprehensive Environmental Response Compensation and Liability Acts, and the California Environment Quality Act, and all applicable federal, state, and local agencies. 9. INSPECTIONS City shall have the right to inspect any work performed hereunder to ensure that the work is being and has been performed in accordance with the applicable federal, state and/or local requirements and this Agreement. Contractor agrees that all work found by such inspections not to conform to the applicable requirements shall be corrected by Contractor, and City shall have the right to withhold payment to Contractor until it is so corrected. 10. CHANGE ORDERS Any changes or deviations from Bid/Proposal, Specification, and approved Project Drawings, or the terms of this Agreement shall be effective only upon written consent of City and the Contractor. All change orders will specifically describe the work and/or changes, the new agreement price and time for completion. 11. INDEMNIFICATION Contractor agrees to indemnify, defend and hold harmless the City of Santa Ana, its officers, agents and employees from and against any and all loss or damage to property and from all injuries or death of any person or persons in the performance of the work under this Agreement. Contractor agrees to indemnify, defend and hold harmless the City of Santa Ana, its officers, agents and employees from and against any and all suits, actions or proceedings of any kind or nature arising out of the acts or omissions of employees or agents of Contractor or its subcontractors. 12. INSURANCE With respect to performance of work under this Agreement, Contractor shall maintain and shall require its subcontractors to maintain insurance as described below: 3 25C-18 (1) Workers' compensation insurance with statutory limits, and employer's liability insurance with limits of not less than $1,000,000 per accident. (2) Commercial general liability insurance or equivalent form, with a combined single limit of not less than $1,000,000 per occurrence. Such insurance shall name Orange County and the City of Santa Ana and their officers, agents and employees as Additional Insured. (3) Business automobile liability insurance, or equivalent form, with a combined single limit of not less than $1,000,000 per occurrence. Such insurance shall include coverage for owned, hired and non-owned automobiles. All insurance coverages required pursuant to this section shall be primary and not contributory with respect to insurance or self-insurance programs maintained by Orange County and/or City; contain standard separation of insured provisions and provide waiver of subrogation clauses. Contractor shall furnish properly executed certificates of insurance and Additional Insured Endorsements to City prior to the commencement of work under this Agreement. Such certificates shall clearly evidence all coverage required above and provide that such insurance shall not be materially changed or terminated except on thirty (30) days prior written notice to City. Contractor shall maintain such insurance from the time work first commences until completion of the work under this Agreement, and replace such certificates for policies expiring prior to completion of work under this Agreement. 13. ASSIGNMENT Contractor shall not assign any rights under this Agreement except upon prior written authorization of City provided that claims or money due or to become due from City under this Agreement may be assigned to a bank, trust company, financial institution or to a trustee in bankruptcy without such approval. Notice of any such assignment or transfer shall be promptly furnished to City. Contractor shall not subcontract any of the services required by this Agreement without written approval of City. Contractor shall not delegate any authority or responsibility that would in any way purport to relieve it of any obligation imposed by this Agreement. 14. CONFLICT OF INTEREST Contractor covenants that it is an independent contractor and not an employee of the City and that its personnel, employees and subcontractors are not employees of the City. Contractor presently has no interest, and shall not have any interest, direct or indirect, which would conflict in any manner with the performance of the work under this Agreement. 15. UNAVOIDABLE DELAYS AND DEFAULTS The time of completion of this Agreement shall be extended by the number of calendar days which Contractor is prevented from performing work as a result of. inclement weather, acts of City not contemplated by this Agreement, the unavailability of workers or materials due to strikes, accident, acts of God, fire, unusual delays in transportation, unavoidable casualties, causes beyond Contractor's control, or any cause which the City may determine justifies the delay. The Contractor shall not be entitled to an extension in the number of calendar days for completion, unless, within five (5) days from the beginning of such delay, it notifies the City in writing of the causes of the delay, which causes must be acceptable to the City. 4 25C-19 16. JURISDICTION/VENUE This Agreement has been executed and delivered in the State of California and the validity, interpretation, performance, and enforcement of any of the clauses of this Agreement shall be determined and governed by the laws of the State of California. Both parties further agree that Orange County, California, shall be the venue for any action or proceeding that may be brought or arise out of, in connection with or by reason of this Agreement. 17. ATTORNEY'S FEES Should any litigation be commenced between the parties to this Agreement concerning the work which is the subject of this Agreement, any provision of this Agreement, or the rights and obligations of either in relation thereto, each party shall be responsible for its own attorney's fees and costs. 18. TIME OF ESSENCE Time is of the essence in performance of this Agreement. 19. EXCLUSIVITY OF AGREEMENT This Agreement supersedes any and all other agreements, either oral or in writing, between the parties hereto with respect to hiring of Contractor by City, and contains all the covenants and conditions between the parties with respect to such employment in any manner whatsoever. Each party to this Agreement, acknowledges that no representations, inducements, promises, or agreement, orally or otherwise, have been made by any party, or anyone acting on behalf of any party, which are not embodied herein, and that any other agreement or amendment to this Agreement shall be effective only if executed in writing and signed by City and Contractor. 21. MISCELLANEOUS PROVISIONS a. Each undersigned represents and warrants that its signature hereinbelow has the power, authority and right to bind their respective parties to each of the terms of this Agreement, and shall indemnify City fully, including reasonable costs and attorney's fees, for any injuries or damages to City in the event that such authority or power is not, in fact, held by the signatory or is withdrawn. b. All Exhibits referenced herein and attached hereto shall be incorporated as if fully set forth in the body of this Agreement. 5 25C-20 IN WITNESS WHEREOF, the parties hereto have executed this Construction Agreement on the date and year first above written. ATTEST: Maria D. Huizar Clerk of the Council Approved as to form: By: Laura Sheedy Assistant City Attorney CITY OF SANTA ANA Paul M. Walters Interim City Manager WEST COAST STORM, INC. (NAME) (Title) Tax ID# RECOMMENDED FOR APPROVAL: Raul Godinez, 11 Executive Director Public Works Agency 6 25C-21 (West Coast Storn nc. Storm Water and Environmental Solutions West Coast Storm Screen Automatic Retractable Screen (ARS) Equipment Design and Specification Report Page 1 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 Telephone 909.890.5700 Facsimile 909.890.5988 Website wnvw.wcstorm.net California General A/IIAZ Contractor License Number: 888152 25C-22 EXHIi3n" rV West Coast Stot-m,lnc. Storm Water and EnWronmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of TVorlc) A. Description/Design/Engineering. The West Coast Storm Screen (Automatic Retractable Screen) Device meets the minimum Hydraulic and Operation Criteria. The West Coast Storm Automatic Retractable Screen (ARS) prevents trash and debris from entering the catch basin during dry weather and moderate storm flows, thereby maintaining trash and debris within the street to be collected by street sweeping and other equipment. The ARS device opens automatically with minimal obstruction to the curb opening before the depth of the storm flow in the street exceeds 3 inches. This device is an approved ARS by the City and County of Los Angeles utilized in their on-going TMDL projects. The West Coast Storm Screen is designed, fabricated, and installed according to the County of Los Angeles specifications and is an approved device by the County of Los Angeles Department of Public Works Design Division specifications: "When in the open position, the ARS must not reduce the hydraulic capacity of the catch basin by more than 10% over the mid and high flow range of the catch basin." The West Coast Storm Screen devices are utilized in the current City of Los Angeles' mandated Regional Water Quality Control Board's Total Maximum Daily Load (TMDL) Catch Basin Opening Screen Cover Project. The County of Los Angeles is included in the City of Los Angeles' Contract with West Coast Storm, Inc. and all units are subject to daily shop and installation inspections to ensure our products meet the County and City specifications. Additionally, West Coast Storm, Inc. completed the County of Los Angeles River Trash Total Maximum Daily Load Full Compliance, Catch Basin Retrofit- Phase 4 Project, which included installation of CPS and ARS devices. Page 2 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-23 61tvv st St ol-m,Inc. Storm ff-'ater and Environmental Sohrtions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) West Coast Storm Automatic Retractable Screens Operation Criteria The ARS device swings open and remains open as long as the flow depth exceeds specified height and return to the mechanically locked and closed position as the flow of water recedes. The West Coast Storm Screen device meets the following criteria: 1) Screens cover the entire existing curb opening. The maximum clear opening between the top, bottom, and sides of the curb opening and the screen or frame of the screen shall be '/z inch. 2) The Device has no springs, pulleys, buckets, troughs or protruding tracks, thereby enabling the full capture trash system to function without obstruction. 3) In curb openings with support bolts, multiple units shall be installed between the existing support bolt(s) to span the entire curb opening width. 4) The existing support bolt(s) shall be protected in place and the operation of the units shall not be hindered by the support of the bolt(s). 5) The maximum clear opening between adjacent screens, adjacent fixed frame members, or between the screens and support bolts shall be ''h inch. 6) At no point in its range of motion shall any part of the screen or the operating mechanism interfere with the function of a CPS device or its bypass. 7) If any part of the frame of the unit is fixed and does not swing open, the maximum allowed width of the fixed part of the frame is 1.5 inches per side per unit. No fixed parts shall obstruct the top or bottom of the catch basin opening. 8) All screens shall be fabricated from twelve (12) gauge (0.105 inches), with %-inch diameter holes, and with a total open area of not less than 50 percent. 9) The edges of the screen shall be ground to remove all sharp edges. 10) The ARS device can be adjusted to open (unlock) at a specific height specified. 11) The operational (locking) mechanism is isolated from the storm drain and debris. A built in 0.50 inch gap between the main screen and ARS ends also insures the mechanism isolation. Page 3 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A1HAZ Contractor License Number: 888152 25C-24 vv? (west Coast Storm,Inc. Storm IVater arrd Enrironme»tal Solullons County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) 12) All ARS devices have a locking mechanism that in the closed position prevents the brushes of street sweeping equipment from opening the screen when sweeping in front of the screen. The mechanism is a gear designed to automatically release and allow the screen to fully open with the flow of water per Operation Section below. 13) The gear locking mechanism for automatically opening the screen is opened by the force of water acting on the inner screen adjusted to open at specified water flow height. Manual release of the screen: push a screwdriver into any lower main screen hole and push the inner screen back to release main screen. 14) The main screen extension is adjusted to specified gap from bottom of catch basin curb opening. The main screen extension is used to insure a uniform %z inch gap from the bottom of the screen to the bottom of the catch basin curb opening across uneven surfaces. 15) The ARS device must open as required when the screen is partially blocked with trash. Note: As an approved County device, the West Coast Storm Screen passed testing by the County of Los Angeles which included hydro-testing and trash and debris blocking requirements. Fabrication The ARS device meets the following requirements: 1) The ARS device is fabricated with a built in overflow or top gap specified. 2) The main screen has 0.75 inch round openings with a 50% open pattern. The main screen extension has 0.75 inch round openings as well. 3) Inner screen extension is adjusted for required water height opening (unlocking) per specifications. 4) A standard 0.50 inch gap between the main screen and the ARS device ends is built in. 5) Parts are CNC punched to -f-/- 0.005 tolerance. 6) All parts are released for fabrication with applicable shop drawings and CNC programs. 7) Completed ARS devices are marked with location ID. 8) Completed ARS devices include all hardware and extensions. 9) ARS devices are shipped completely assembled. Page 4 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-25 West Coast Storm,Inc. Storm Dater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Device Assembly, Manufacturing. The ARS device is assembles according to the following requirements: I ) CNC punch all individual parts. 2) Place main screen extension onto main screen with bend facing up. 3) Secure extension to main screen using 10-32 screws and washers. 4) Place inner screen ends into sides of main screen. Place inner screen over the ends with holes aligned. 5) River inner screen to ends as shown insuring there is a minimum amount of lateral play. 6) Insert inner screen extension to inner screen. Secure inner screen extension to inner screen using 10-32 CRES screws and washers. 7) All screws will have an application of loctite in the field after adjustment to catch basin curb opening. 8) Gears assembled into sides and apply loctite. Insure gears move freely. 9) Place main screen assembly into ends. Place frame member onto ends and rivet together. 10) Seam weld in four places per drawings. Weld anti-theft washers to top pivots according to drawings. 11) Follow Quality Control Procedures to insure free movement of screen and locking mechanism functions properly. 12) Main screen extension is adjusted by loosening the 4 adjustment screws. The extension is lowered to a minimum 0.50 inch to a maximum 0.75 inch from the bottom of the drain opening. 13) Inner screen extension is adjusted by loosening the 3 adjustment screws. The extension can be lowered per specification. For example, if the desired screen opening is 1 inch water depth, the inner screen extension should be lowered to a one inch distance between the bottom of the extension and the bottom of the drain opening. 14) In grate installations, a grate filler plate is fabrication to ARS length. See drawings for more details. 15) ARS devices are shipped completely assembled. Field adjustments are made based on extension needs. No field welding of the ARS device is necessary. All sharp parts/edges are grinded at factory and in field as needed. Page 5 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-26 Y We! st Coast Stol n,lnc. Storm {Yater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-59I792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Installation and Removal. The screens are bolted to the concrete walls and soffit of the catch basin. No part of the screen or mechanism shall interfere with the removal of any existing gratings. Standard Design Elements (ARS): 12 gauge stainless steel screen with 3/4 -inch diameter holes with at total open area of not less than 50%. Locking mechanism prevents the brushes of street sweeping equipment from opening the screen while sweeping. The locking mechanism also prevents tampering of the units. The West Coast Storm Screen is specifically designed to open automatically by force of water during a rain event. The locking mechanism operates on horizontal pressure, not vertical pressure; this design keeps the units free of debris and sediment. The CAM gear design of the locking mechanism means no springs that break, no pulley or counter weights that require frequent maintenance, adjustment, or replacement. The ARS design has few moving parts, a simpler design is a more efficient, ease of maintenance, and working design. The gate closes upon water receding, no drainage of weeping buckets or cleaning out of operation components are needed. Below is an example of an installation in Coral Gables, Florida demonstrating an area where install conditions were good. Page 6 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-27 v West Coast Stonn,Inc. Storm JMater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Below is an installation of a long length drain at an Orange County installation site Buena Vista and Olive, EN showing multiple cell installations. Whether the drain is long or short, West Coast Storm, Inc. is able to retrofit according to needs. Page 7 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-28 wv? West Coast Storm.hlc. Storm O'ater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Tailored Design Elements: Device is manufactured to specification based on curb inlet height and length. The design can accommodate small to long inlets, any height, any curb length. Curved inlets can be fitted to meet capture needs, variable heights accommodations, out of square configurations. Drop down attachments allow unit conformity in even the most challenging dimensions, irregularities, and poor masonry workmanship. See the South Carolina installation photo below where the drain conditions were far from perfect. Installation was successful and assisted Richland County to remain in compliance. Page 8 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-29 West Coast Storm.] nc. Storm 11'ater a?rd Environmental Solutiars County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) CAD Files for the West Coast Storm Screen Device Automatic Retractable Screens Page 9 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General AMAZ Contractor License Number: 888152 25C-30 v West Coast Stonn,inc. 'Storm Maier and Emph-onmenial Sohilions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under .4 ttachnientA. Scope of Work) Materials. The West Coast Storm Screen ARS device meets the following requirements: 1) The ARS device is fabricated from 8-304 stainless steel. The structural members have a minimum thickness of 3/16 inches. 2) All S-304 structural shall be welded by a certified welder. 3) The ARS device is constructed of 12 gauge S-304 stainless steel except for the inner sail which is 20 gauge S-304 stainless steel. 4) All mounting hardware, bolts, screws, anchors, nuts, and washers are comprised of S-304 stainless steel. 5) Main Gear (locking mechanism) is integrated in the device. The locking mechanism is isolated from the storm drain and debris. A built in 0.50 inch gap between the main screen and ARS ends also insures the mechanism isolation. Flow or Range of Flows. The West Coast Storm screen is an approved automatic retractable screen device passing certain testing and specifications set forth by the City and County of Los Angeles. The West Coast Storm Screen is designed, fabricated, and installed according to the County of Los Angeles specifications and is an approved device by the County of Los Angeles Department of Public Works Design Division specifications: "When in the open position, the ARS must not reduce the hydraulic capacity of the catch basin by more than 10% over the mid and high flow range of the catch basin." The West Coast Storm Screen is also an approved device by the San Francisco Bay Regional Water Quality Control Board. Estimated Design Life. 25 years. Page 31 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-31 v X851 COI't11,I11C. Storm iVater a?rd Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP## 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) B. Performance Effectiveness for Connector Pipe Screens and Catch Basin Inserts. Automatic retractable screen are utilized to prevent trash from entering the storm drain during dry weather. Southern California's dry climate in a majority of the year. It is imperative to prevent trash from entering storm drains, enabling easy trash removal. According to a study carried out by the City of Los Angeles and approved by the Los Angeles Regional Water Quality Control Board. According to the City of Los Angeles, the effectiveness of the ARS helps reduce trash levels in storm drains by approximately 80%. C. Siting, Operational, and Maintenance. Installation Process. I . Prior to installation, measuring information is input into the ACCESS database. The sharing municipality can look at the information provided. This reporting process gives the municipality the information it needs to decide whether to proceed with installing at sites specified or not. 2. Our Santa Ana location provides West Coast Storm, Inc. with the ability to get our products and crews to any location within the County of Orange in minutes, not hours. 3. Up to 25 Two-man installation crews are ready to begin work. Each Crew consists of a Supervisor responsible for completion of all paperwork, correct Confined Space Entry procedures and traffic control protocol. All crews are equipped with a Company marked van; all installation tools and equipment necessary to complete the job. All traffic control devices, confined space entry equipment including 4-gas meter, man-lift tripod and harness are kept in the van. Vans are equipped with storage of all installation parts, and spare parts as needed. 4. Crews must set up traffic control and confined space procedures prior to installation. All of West Coast Storm field personnel, including Project Managers, are annually confined space rescue, confined space entry, and traffic control trained. 5. Project Managers meet with crews prior to installations daily. The Project Manager oversees units staging and distribution, parts distribution, and leads the mandatory daily tailgate safety meeting according to OSHA requirements. Page 32 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-32 v V k," West Coast Storm, Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) 6. Installation crews are provided a scheduled list of drains for installation on a daily basis. Each crew must report all confined space entries on forms provided. Each installation is reported on a BMP report form to record all installation procedures and quality control tests. 7. Crews are required to call into the office upon completion of every drain installation: time spent at drain, ARS length, CPS type, and any additional information. This real-time dispatch enables health & safety tracking, OSHA logs for confined space entry, and maintain cost controls for labor. 8. Paperwork from the day's installation includes BMP report forms on every install, work orders, time sheets, and confined space entry logs. When the paperwork arrives to the office the data from BMP report forms and the real-time dispatch is entered into the ACCESS database. Entering installation information on a daily basis ensures each drain is tracked and reported timely and accurately. 9. In addition to database input, a daily installation report of installs is sent to the municipality. Communication of daily installs ensures the job is progressing and continuing as scheduled. 10. Project Managers perform QAQC: Quality Assessment and Quality Control everyday. Managers are required to visit installations sites and perform health and safety checks. This process ensures public safety, workforce safety, no damage to property, as well as device installation ensuring it is complete and functioning properly. 11. Estimated time required to install each device is 20 minutes. West Coast Storm Screen Installation Process. 1. Before cutting the child safety bar you must slide the ARS unit into the drain opening for a test fit. If the unit slides in, pull the units back out and cut the child safety bars off if necessary. Do not cut the vertical support bar off. 2. Set the ARS unit(s) in front of the drain numerically from left to right. 3. Attach the mounting brackets (85-009) and hand-tighten the 3/8-16 hex nuts onto the ARS unit(s). 4. Place the unit(s) in the catch basin opening with the technician. 5. The technician will slide the unit 1-inch from curb batter. Using a tape measure, verify f - inch horizontally from center of front screen to curb batter line. Page 33 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-33 (west Coast Stonn.Inc. Storm Water and Cnvironinental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 0$0-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Altachment A. Scope of Work) 6. Place a level on the front end (85-001), and verify the unit is vertically level. Upon adjustment of the unit to vertical level position, ensure positioning is 1-inch horizontally from center of front screen to curb batter line. 7. Once the unit is level and proper positioning is verified, the technician will secure the unit for installation. 8. Slide the mounting brackets (85-009) up and/or down until they meet the wall face. 9. Tighten the 3/8-16 hex nuts to the ARS unit utilizing Loctite Red (thread locker). 10. Utilizing the Hammer Drill, drill two 3/8-inch pilot holes into the concrete. Drill the two holes a minimum of 6 inches apart in the sidewalls. 11. Hammer the 3/8-inch drop anchor SS sleeve as straight as possible until it is imbedded a minimum of 3-inches into the wall. 12. Place the standard washer and 3/8-16 nuts onto the 3/8-inch concrete drop anchor. Drill the two holes a minimum of 6 inches apart in the sidewalls. 13. Use a 14mm open-end wrench or socket ratchet and tighten until secure. Utilize Loctite Red (thread locker) before securing. Site-specific Measurements Required. West Coast Storm, Inc. requires minimum information prior to measuring, only drain location. In the even there is not clear data on drain locations, we can locate them upon municipality approval. Information provided to municipalities will include GPS coordinates, address, as well as catch basin measurements. We can and will work with municipal staff to acquire the proper information needed to import into a GIS mapping layer database. Equipped with an industry leading ACCESS database helps us export the information to create GIS mapping layers. Page 34 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General AMAZ Contractor License Number: 888152 25C-34 .. v V '.. ?J West Coast Storm, Inc. Storm it'ater and Envirortntental Soltitions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of fVork) Regulatory Permits Required for Installation. Confined space entry permitting is required on all drain installations. 40-hour HAZWOPER training is required for storm drain entry. Maintenance Requirements. Preventative Maintenance of regular street sweeping will prevent debris from building up in front of the unit. Suggested Yearly Maintenance. Inspections consist of visually inspecting the unit from street level and performing an opening-lock function check. Visual Inspection: 1. Clean away any built-up debris and foreign object debris. Remove any visible debris that may be on, in front of, and nearby the unit. 2. Look for any visible signs of vandalism or damage that may compromise the unit's ability to properly function. Attempted vandalism and slight damage should be inspected closely to ensure no future damage may result. Opening-Lock Function Check: I . Using a pen or screwdriver, insert it through the perforated openings at the center of the main screen in order to make contact with the sail (locking mechanism). 2. Push forward until the screen unlocks and hinges open. 3. Place your opposite hand against the screen so it does not close, slowly remove the pen or screwdriver from hole. 4. Slowly guide the screen down just before it locks, remove your hand letting the weight of the screen lock itself. 5. If the unit is not opening and closing to the standard in which it was installed and the unit is not hindered by debris or F.O.D. (foreign object debris) then the unit may be damaged and replacement may be necessary. Contact West Coast Storm, Inc. for further assistance. Page 35 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-35 RWPoast Storm.Inc. Scorn: Water and Environmental Sohrtions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of YFork) Durability. The West Coast Storm Screen locking mechanism prevent tampering and opening of the unit during street sweeping. No components of the unit protrude beyond the curb face whether in the locked or open position. Therefore, parked cars, moving cars, bicyclists, or pedestrians are not exposed to any protruding safety hazards and cannot damage the unit as a result. The unit's stainless steel construction allows us to offer a ten year warranty without hesitation. Availability of Replacement Parts and Life Expectancy. Manufacturing all components in-house is key, we are not subject to outside vendors or distributors out of inventory. In the event, replacement parts are needed, we will have your item readily available. Life expectancy is minimum 25 years. Stainless steel components should last the lifetime of the drain itself. Waranty. All parts and labor is covered for 10 years. Aesthetics and Safety. All manufacturing is performed with aircraft precision equipment. No manufacturing of units are performed in the field. Units are delivered assembled and ready for installation.Al1 parts are put through a timesaver deburring rough edges, resulting in a product that has no sharp edges. No components of the unit protrude beyond the curb face whether in the locked or open position. Therefore, parked cars, moving cars, bicyclists, or pedestrians are not exposed to any protruding safety hazards and cannot damage the unit as a result. Uniqueness. The locking mechanism operates on horizontal pressure, not vertical pressure; this design keeps the units free of debris and sediment. The CAM gear design of the locking mechanism means no springs that break, no pulley or counter weights that require frequent maintenance, adjustment, or replacement. The ARS design has few moving pants, a simpler design is a more efficient, ease of maintenance, and working design. The gate closes upon water receding, no drainage of weeping buckets or cleaning out of operation components are needed. Page 36 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-36 v v '?.J West Coast Stonminc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) D. Vendor's Installation Background. West Coast Storm, Inc. is a General A Engineering contractor with a hazardous substances removal certification combining storm water services and manufacturing in one company. Certified welders, certified fabrication machine operators, and up to 25 Two-man installation crews are ready to begin work. Our Santa Ana location provides West Coast Storm, Inc. with the ability to get our products and crews to any location within the County of Orange in minutes, not hours. All of West Coast Storm, Inc. operations personnel are fully trained under the following minimum requirements: - 40-Hour Hazardous Waste Operations Emergency Response (HAZWOPER) training in accordance with 29 Code of Federal Regulations (CFR) 1910.120 - 8-1-lour Hazardous Waste Operations Refresher training in accordance with 29 CFR 1910.120 - Confined Space Rescue and Entry training in accordance with 29 CFR 1910 In Addition, every operating employee of West Coast Storm, Inc. is enrolled in the Department of Motor Vehicles (DMV) Employee Pull Notice (EPN) Program as well as a Department of Transportation (DOT) Approved Random Drug and Alcohol Testing Program. All installation crews undergo rigorous installation training, emphasizing safety and quality control. Installers have hours of experience on many ARS & CPS installation projects performed countrywide. Page 37 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-37 e est Coast Storln,Inc. .................... ---=-. Storm Uater and Lnrlronmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Frill Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Screen Automatic Retractable Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) West Coast Storm, Inc. (WCS) has extensive experience in projects similar to that called for by present RFP. WCS has worked with public and private entities. All operations for the measuring, manufacturing and installation of the products are handled solely by WCS, no subcontractors are needed. Experience in municipal ARS &CPS projects includes finding drain locations, measuring and compiling reports to municipalities on the status of drains measured, upon release of the measured drains by the municipality (Purchase Order) manufacturing operations begin as soon as measurements are released by WCS, shipments are sent daily from Santa Ana to install crews, meeting sites are coordinated by Project Managers to best accommodate installation areas, installations are performed with proper traffic control measures and confined space entry protocol, real-time dispatch reporting from field to WCS office upon completion of each drain, daily reports are comprised and sent to the municipality upon QC, direct contact liaison relationships are established between project managers, office personnel, and municipalities. Handling the job from beginning to finish had proven to clients we are a simple, effective, and efficient way to do business. Similar product installations of Connector Pipe Screen and/or Automatic Retractable Screen projects include the County of Los Angeles, City of Rancho Palos Verdes, City of Anaheim, City of Beverly Hills, City of San Bernardino, City of Perris, City of Burlingame, City of Oceanside, City of Pico Rivera, City of Torrance, City of Fort Worth, Texas, Richland County (South Carolina); the State of Florida Department of Transportation and many others. Page 38 of 45 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-38 West Coast S gn-n,tnc. Storm {rater and Environmental SOlntions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) A. Description/Design/Engineering. The West Coast Storm.Connector Pipe Screen (CPS) Device meets the full trash capture definition set forth by the Los Angeles Regional Water Quality Control Board. West Coast Storm, Inc. (WCS) has successfully performed three County of Los Angeles contracts requiring Connector Pipe Screen (CPS) installations. All CPS devices were fabricated and installed per the Los Angeles Regional Water Quality Control Board approved specifications for the County of Los Angeles Connector Pipe Screen Device Full Capture System. See Certifications at the end of this section. Additionally, the West Coast Storm Connector Pipe Screen is San Francisco Bay Water Board Certified Device for frill capture. See Certifications at the end of this section. Description and Design Elements. General. The CPS prevents trash and debris from entering the storm drain lateral system by keeping the trash and debris inside the catch basin. West Coast Storm CPS Design. The CPS device is designed to retain all trash larger than 5 mm in the catch basin, thereby meeting the Regional Water Quality Control Board's definition of full capture in both Los Angeles and San Francisco Regions. 1) The CPS is designed and installed to maximize the trash capture volume of the catch basin. 2) The CPS bypass accommodates the catch basin design capacity if the screen becomes clogged. 3) The CPS does not interfere with the operation of the West Coast Storm Screen ARS devices. 4) The CPS is designed with a structural integrity to withstand a force of standing water (62.4lb/ft3) within the catch basin area if the screen is 100% clogged. 5) The center horizontal brace further secures the screen to the frame and add additional strength against severe water force. 6) The CPS is designed with a structural frame built to withstand a significant amount of force. The 5mm mesh is secured to the framework further enhancing the structural integrity of the unit. Page 2 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-39 v k,. pest WCoast Storin,Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of JVork) 7) The CPS is located or configured with deflector plates or screens such that street flows will be prevented from falling between the screen and the connector pipe. Any deflector plate shall be able to support a constant load of 10 lbs per linear foot. 8) The bottom and sides of the CPS unit is fabricated to conform tightly to the catch basin with a maximum gap of 5mm 9) The CPS shall be able to retain the trash and debris and prevent it from scouring and discharging with subsequent rain events. 10) The perimeter of the CPS includes a structural frame for stiffness, designed keyhole slots to fasten the CPS to the wall of the catch basin enabling complete removal of the unit if needed. 11) All components of the CPS are designed to remain secure during foreseeable storm water and debris flows and cleaning. The CPS is removable solely by the removal of mounting screws/bolts. 12) All parts/components of the CPS are sized to fit through the catch basin's manhole opening when the unit is disassembled. 13) Keyhole mounting provides for easy removal. 14) Bypass access door allows vertical access to the outlet pipe for cleaning. The access opens 90 degrees allowing the unit to stay open during cleaning. Stop supports are built into the bypass hatch frame to prevent the door being forced inward by water pressure or debris. Standard Design Elements (CPS): 5mm screen mesh, keyhole mounting slots, center and side extensions, 1 inch return flange, single wall mount unit, double wall mount, structural frame, bypass maintenance hatch. Tailored Design Elements: Bypass top with height variable supports, corner mount unit, angles units, floor units, removable bypass screen tops, top deflector plate, and an entirely removable unit. Page 3 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General AIHAZ Contractor License Number: 888152 25C-40 e)? v v %.. - West Coast Storm,inc. Storm {rater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFPH 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Mork) Sizing. The smallest workable catch basin dimension are H18" by W18." There is no restriction on large catch basins. Catch Basin Types & Configurations. Designed to address most types of catch basins: Types 300, 301, 302, 303, 305, 306, 307 to name a few. The CPS device is fabricated and installed to conform to the various configurations of the catch basin, keeping in mind the various layouts of the connector pipe, including designing a CPS with deflector plates or screen to prevent trash from falling between the screen and connector pipe. Page 4 of 41 654 South Lincoln Avenue, San Bernardino, CA 92448 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number 888152 25C-41 West Coast Stonn,Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A Scope of Mork) Materials. The CPS device meets the following requirements: 1) The CPS frame is manufactured/fabricated from 5-304 stainless steel. The structural members have a minimum thickness of 3/16 inches. 2) The CPS screen is manufactured/fabricated from perforated metal of Type 304 stainless steel. The geometrical opening shape is a diameter of 5mm. 3) The screen material used is at least 50% open area. 4) Any edge of the CPS that is not flush with the wall or floor of the catch basin shall be smooth with no prongs or jagged edges. 5) The assembly bolts, screws, nuts, and washers are fabricated entirely from S-304 stainless steel. Fabrication. The CPS device meets the following requirements: 1) CPS devices are fabricated to individual field measurements. 2) Bypass height is specified with the field measurements. 3) The need for a bypass top is specified with the field measurements: 4) Horizontal and vertical members are modified to the necessary measurements, drawings, and CNC programs are released. 5) Parts are CNC punched to +/- 0.005 tolerance. 6) Parts are formed to +/- 0.015 tolerance. 7) Parts are assembled and welded to +/- 0.030 tolerance. 8) All pants are released for fabrication with applicable shop drawings and CNC programs. 9) CPS assembly is by seam welding. 10) Completed CPS devices are marked with location ID. 11) Completed CPS devices include all hardware and bottom extensions. 12) CPS devices are shipped completely assembled. Page 17 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-42 West Coast Stonn,lnc. Storm lVater and Envirownental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Device Manufacturing Assembly. The CPS device is assembled accordu1g to following requirements: 1) CNC punch all individual parts. 2) Form (bend) all parts to the appropriate drawing. 3) Insert all necessary hardware into the required parts. 4) Seam weld the vertical members to the horizontal members ]Waking the frame. 5) Be sure frame is square. 6) Cut individual perforated screen for necessary areas. 7) Tack weld the perforated screen into the frame. 8) Using the 10-32 CREW screws, attach the appropriate bypass supports (if needed). 9) Using the 10-32 CREW screws, attach the appropriate bypass top (if needed). 10) Using the 10-32 CREW screws, attach the bottom extensions. 11) Mark the CPS device with the applicable location ID. 12) CPS devices are shipped completely assembled. Most CPS devices will fit through the man hole assembled. If they don't fit, the bypass top and supports can be removed and re- assembled in the storm drain. Flow or range of flows for which device is rated (in cubic feet per second). The table below provides an example of screen capacity in cubic feet per second based on a catch basin with a 3.5' V-depth. V-depth (ft) CB width Max 10-yr. flow rate (efs) Bypass Height (in) Freeboard (in) Screen Height (in) Max 1-yr. flow rate (cfs) Clearance (in) Screen Length (ft) Screen Capacity (cfs) 3.5 3.5 2.8 6.0 6.0 18 0.6 10.0 1.5 1.5 3.5 7.0 5.3 6.0 6.0 18 1.2 10.0 2.9 2.9 3.5 10.0 7.5 6.0 5.0 18 1.7 10.0 3.8 3.8 3.5 14.0 10.0 8.0 0 18 2.2 8.0 3.1 3.1 3.5 21.0 13.9 8.0 0 18 3.1 8.0 4.3 4.3 3.5 28.0 17.3 12.0 0 18 3.8 4.0 3.9 3.9 Note: Results were obtained from the California Regional Water Quality Control Board, Los Angeles Region Approved County ofLos Angeles Connector Pipc Screen Design Technical Report, page 12. Page 18 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-43 v V ?St clesoltC-ost Slorm,lnc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Estimated design life of equipment. Minimum 25 years. B. Performance Effectiveness for Connector Pipe Screens and Catch Basin Inserts. Performance. The purpose of the Connector Pipe Screen is designed to retain all trash larger than 5mm in the catch basin, it prevents trash and debris from entering the storm drain lateral keeping the trash inside the catch basin. When trash is prevented from entering the lateral system a reduction in clogged and standing trash and debris within drain laterals result. Trash reduction meets requirements approved by the County of Los Angeles Regional Water Quality Control Board. Capturing trash and enabling water flow keeps the storm drain system operating at its engineered design capacity. Trash Capture. Capacity is determined by the dimensions of the catch basin, which is utilized as the receptacle to hold trash captured. For example, a three and a half foot catch basin "V-depth" will hold an eighteen inch tall screened device with a G inch bypass. The device is designed to capture trash up to the device's bypass within the catch basin. Page 19 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number. 888152 25C-44 West Coast Stomi Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Overflow or bypass flow capacity. The bypass structure must pass the maximum catch basin flow in order to provide proper flow protection. The West Coast Storm CPS is designed to meet this requirement established by the California Regional Water Quality Control Board, Los Angeles Region Approved County of Los Angeles Connector Pipe Screen Design. For an example of maximum 10-year and 1-year flows see the table provided see below. V-depth (ft) CB Width Max 10-yr. flow rate (cfs) Bypass Height (in) Freeboard (in) Screen Height (in) Max 1-yr. flow rate (cfs) Clearance (in) Screen Length (ft) Screen Capacity (cfs) 3.5 3.5 2.8 6.0 6.0 18• 0.6 10.0 1.5 1.5 3.5 7.0 5.3 6.0 6.0 18 1.2 10.0 2.9 2.9 3.5 10.0 7.5 6.0 5.0 18 1.7 10.0 3.8 3.8 3.5 14.0 10.0 8.0 0 18 2.2 8.0 3.1 3.1 3.5 21.0 13.9 8.0 0 18 3.1 8.0 4.3 4.3 3.5 28.0 17.3 12.0 0 18 3.8 4.0 3.9 3.9 Now Xesuits were obtained from the California Regional Water Quality Control Board, Los Angeles Region Approved County of Los Angeles Connector Pipe Screen Design Technical Report, page 12. Page 20 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/FIAZ Contractor License Number: 888152 25C-45 West Coast Stol`111,Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) C. Siting Operational, and Maintenance. Installation Process. 1. Prior to installation, measuring information is input into the ACCESS database. The sharing municipality can look at the information provided. This reporting process gives the municipality the information it needs to decide whether to proceed with installing at sites specified or not. 2. Our Santa Ana location provides West Coast Storm, Inc. with the ability to get our products and crews to any location within the County of Orange in minutes, not hours. 3. Up to 25 Two-man installation crews are ready to begin work. Each Crew consists of a Supervisor responsible for completion of all paperwork, correct Confined Space Entry procedures and traffic control protocol. All crews are equipped with a Company marked van, all installation tools and equipment necessary to complete the job. All traffic control devices, confined space entry equipment including 4-gas meter, man-lift tripod and harness are kept in the van. Vans are equipped with storage of all installation parts, and spare parts as needed. 4. Crews must set up traffic control and confined space procedures prior to installation. All of West Coast Storm field personnel, including Project Managers, are annually confined space rescue, confined space entry, and traffic control trained. 5. Project Managers meet with crews prior to installations daily. The Project ]Manager oversees units staging and distribution, parts distribution, and leads the mandatory daily tailgate safety meeting according to OSHA requirements. 6. Installation crews are provided a scheduled list of drains for installation on a daily basis. Each crew must report all confined space entries on forms provided. Each installation is reported on a BUT report form to record all installation procedures and quality control tests. 7. Crews are required to call into the office upon completion of every drain installation: time spent at drain, ARS length, CPS type, and any additional information. This real-time dispatch enables health & safety tracking, OSHA logs for confined space entry, and maintain cost controls for labor. Page 21 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-46 yW e st ast Storln,lnc. Storm TYaler and Environmental Sohnions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) 8. Paperwork from the day's installation includes BMP report forms on every install, work orders, time sheets, and confined space entry logs. When the paperwork arrives to the office the data from BMP report forms and the real-time dispatch is entered into the ACCESS database. Entering installation information on a daily basis ensures each drain is tracked and reported timely and accurately. 9. In addition to database input, a daily installation report of installs is sent to the municipality. Communication of daily installs ensures the job is progressing and continuing as scheduled. 10. Project Managers perform QAQC: Quality Assessment and Quality Control everyday. Managers are required to visit installations sites and perform health and safety checks. This process ensures public safety, workforce safety, no damage to property, as well as device installation ensuring it is complete and functioning properly. 11. Estimated time required to install each device is 20 minutes. Connector Pipe Screen Device Installation Process. 1. Bring the CPS unit into the catch basin and set in front of outlet hole. The unit may . require that you detach the bypass component depending on the size of the catch basin opening. Establish a definite location and then mark your holes for drilling. Make sure to mark in a spot that will allow for unit removal through the predrilled keyhole slots. 2. Remove the CPS unit from the installation wall. Drill 3/8" holes where you marked. Make sure to drill straight into the catch basin wall to avoid mounting difficulties. 3. Hammer 3/8"035" stainless steel anchor bolts into the holes. 4. After all of the anchor bolts are hammered into place, attach the CPS onto the anchor bolts to assure a proper fit. 5. Remove the bypass top screen with bypass supports. Then position the drop down panels inside the body of the CPS unit to estimate for custom cuts. The drop- down panels are designed to bridge the gap between the bottom of the CPS unit and the bottom of the catch basin which is usually concave. Carefully mark onto the drop down panel where your custom cuts should go. 6. Make cuts using a compact grinder. Be sure to sand off any sharp edges. 7. Once the drop down panels are custom cut to conform with the catch basin surface, attach the panels to the body of the CPS unit using bolts provided. 8. Replace the bypass roof and vertical legs to the CPS body. Tighten with bolts provided. 9. Tighten the nuts on all of the anchor bolts and assure a tight fit. Page 22 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-47 West Coast S ol-n,1nc, Storm Waler and Environmental Solnlions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Site-specific Measurements Required. West Coast Storm, Inc. requires minimum information prior to measuring, only drain location. In the even there is not clear data on drain locations, we can locate them upon municipality approval. Information provided to municipalities will include GPS coordinates, address, as well as catch basin measurements. We can and will work with municipal staff to acquire the proper information needed to import into a GIS mapping layer database. Equipped with an industry leading ACCESS database helps us export the information to create GIS mapping layers. Regulatory Permits Required for Installation. Confined space entry permitting is required on all drain installations. 40-hour HAZWOPER training is required for storm drain entry. Maintenance Requirements. Preventative Maintenance. Maintenance crews should regularly check catch basins and establish a maintenance schedule based on the level of debris collected. Some areas will require more frequent cleaning than others. Catch basins should be cleared of debris to allow for water to freely flow through the screens. Pressure-washing the unit may additionally benefit but is not necessary. Suggested Yearly Maintenance. Visual Inspection: 1. Built-up debris and foreign object debris can hinder the unit's operation. Remove any visible debris that may be on, in front of, and nearby the unit. 2. Look for any visible signs of vandalism or damage that may compromise the unit's ability to properly function. Attempted vandalism and slight damage should be inspected closely to ensure no future damage may result. Page 23 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General AIHAZ Contractor License Number. 888152 25C-48 West Coast Storm, Inc. Storm lf?ater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) Durability. The stainless steel structural framework (ecto-skeletal frame) provides structural integrity to withstand extreme amounts of water pressure. Installation within the catch basin ensures no external factors present to damage unit. The unit's stainless steel construction allows us to offer a ten year warranty without hesitation. Availability of Replacement Parts and Life Expectancy. Manufacturing all components in-house is key, we are not subject to outside vendors or distributors out of inventory. In the event, replacement parts are needed, we will have your item readily available. Life expectancy is minimum 25 years. Stainless steel components should last the lifetime of the drain itself. Waranty. All parts and labor is covered for 10 years. Aesthetics and Safety. All manufacturing is performed with aircraft precision equipment. No manufacturing of units are performed in the field. Units are delivered assembled and ready for installation. All parts are put through a timesaver debuiring rough edges, resulting in a product that has no sharp edges. Uniqueness. The stainless steel structural framework (ecto-skeletal frame) provides structural integrity to withstand extreme amounts of water pressure. The bypass maintenance hatch is specially designed for ease of drain cleaning operations. Drop down extension plates enable conformity to the catch basin interior without compromising the unit's and structural strength. Page 24 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-49 West Coast StornInc. Storm TYater and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (Information provided to the City as requested in the RFQ documents under Attachment A. Scope of Work) D. Vendor's Installation Background. West Coast Storm, Inc. is a General A Engineering contractor with a hazardous substances removal certification combining storm water services and manufacturing in one company. Certified welders, certified fabrication machine operators,and up to 25 Two-man installation crews are ready to begin work. Our Santa Ana location provides West Coast Storm, Inc. with the ability to get our products and crews to any location within the County of Orange in minutes, not hours. All of West Coast Storm, Inc. operations personnel are fully trained under the following minimum requirements: - 40-Hour Hazardous Waste Operations Emergency Response (HAZWOPER) training in accordance with 29 Code of Federal Regulations (CFR) 1910.120 - 8-Hour Hazardous Waste Operations Refresher training in accordance with 29 CFR 1910.120 - Confined Space Rescue and Entry training in accordance with 29 CFR 1910 In Addition, every operating employee of West Coast Storm, Inc. is enrolled in the Department of Motor Vehicles (DMV) Employee Pull Notice (EPN) Program as well as a Department of Transportation (DOT) Approved Random Drug and Alcohol Testing Program. All installation crews undergo rigorous installation training, emphasizing safety and quality control. Installers have hours of experience on many ARS & CPS installation projects performed countrywide. Page 25 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-50 West Coast Storm.Inc. Storm Water and Environmental Solutions County of Orange, OC Public Works Automatic Retractable Screen Excluders, Connector Pipe Screen Full Capture Trash Systems, and Catch Basin Inserts RFP# 080-591792 West Coast Storm Connector Pipe Screen Equipment Design and Specification Report (information provided to the City as requested in the RFQ documents under Attachment A. Scope of TYork) West Coast Storm, Inc. (WCS) has extensive experience in projects similar to that called for by present RFP. WCS has worked with public and private entities. All operations for the measuring, manufacturing and installation of the products are handled solely by WCS, no subcontractors are needed. Experience in municipal ARS &CPS projects includes finding drain locations, measuring and compiling reports to municipalities on the status of drains measured, upon release of the measured drains by the municipality (Purchase Order) manufacturing operations begin as soon as measurements are released by WCS, shipments are sent daily from Santa Ana to install crews, meeting sites are coordinated by Project Managers to best accommodate installation areas, installations are performed with proper traffic control measures and confined space entry protocol, real-time dispatch reporting from field to WCS office upon completion of each drain, daily reports are comprised and sent to the municipality upon QC, direct contact liaison relationships are established between project managers, office personnel, and municipalities. Handling the job from beginning to finish had proven to clients we are a simple, effective, and efficient way to do business. From 2009 to 2010, WCS was honored to perform under contract with the County of Los Angeles for multiple projects including the manufacturing and installation of over 1,800 Connector Pipe Screen (CPS) devices and 2,500 Automatic Retractable Screen (ARS) devices for the County of Los Angeles River Trash Total Maximum Daily Load Full Compliance, Catch Basin Retrofit-Phase 4; manufacturing and installation of over 1,000 Connector Pipe Screen (CPS) devices for the Los Angeles River Trash Full Capture City of Los Angeles High Trash Generation Area Catch Basin Retrofit; installation of 101 Connector Pipe Screen (CPS) devices for the Ballona Creek Trash TMDL Full Compliance Phase 2, Catch Basin Retrofit project in the unincorporated community of View Park. Similar product installations of Connector Pipe Screen and/or Automatic Retractable Screen projects include the City of Los Angeles, City of Rancho Palos Verdes, City of Anaheim, City of Beverly Hills, City of San Bernardino, City of Perris, City of Burlingame, City of Oceanside, City of Pico Rivera, City of Torrance, City of Fort Worth, Texas, Richland County (South Carolina), the State of Florida Department of Transportation and many others. Page 26 of 41 654 South Lincoln Avenue, San Bernardino, CA 92408 - Telephone 909.890.5700 Facsimile 909.890.5988 California General A/HAZ Contractor License Number: 888152 25C-51 i D oy a 'iu Ml.?CAOY 0 •, o r ti LsGIVVI CM ti r 1+ ?u?t1 0 "Ja 1 1- 0 LL M oil FA? e t. to 25C-52 EX PART TWO: FUNDING (continued) Estimated Capital Costs Item H Description Unit Quantity Unit Price Amount 1 ARS & CPS Nest Coast Storm <4' 9 $ 674 $ 6,066 2 ARS & CPS Nest Coast Storm 4.1'-G 6 S 900 $ 5,400 3 ARS & CPS West Coast Storm 61-10' 25 $ 996 $ 24,900 4 ARS & CPS West Coast Storm 10.11-16 36 $ 1,190 S 42,840 5 ARS & CPS West Coast Storm >16, 13 $ 1,590 $ 20,670 Total Catch Basins 89 Subtotal: $99,876 Estimated Installation Costs Item # Description Unit Quantity Unit Price Amount S - S - S - S - S - $ - S - S - S - S - S - S - S - S - Subtotal: SO Other Costs Item # Description Hour dollars/hour Amount S - S - Catch Basin Lispections by City Staff 311.5 $ 51 S 15,849 89 catch basins at 3x / year for 10 years S - S - (assuming 7 munUes per inspection) $ $ _ 3x / year is dependent on storm events $ _ S - EA Dollars/year total/ 10-yr Contracted BNtP Cleaning and Maintenance 89 $ 70.00 S 62,300 89 catch basins at min. 2x1yr. for 10 years. S - $ - 2x f year is dependent on store events Subtotal: $78,149 TOTAL PROJECT COST $178,025 Page 8 25C-53 25C-54