SETTLEMENT AGREEMENT
G AND MUTUAL RELEASE OF CLAIMS
This Settlement Agreement and Mutual Release of Claims (hereinafter referred to as the
1- "AGREEMENT ") is entered into by and between ARNIE PIKE (hereinafter referred to as
"PIKE "), and the CITY OF SANTA ANA (hereinafter referred to as "CITY "). PIKE and the
k�, CITY may individually be referred to as a PARTY or collectively as the "PARTIES ".
This AGREEMENT acts exclusively to settle PIKE'S claims for removal of the
architectural barriers to disabled access he alleges exist at the Bowers Museum, located at 2002
N. Main Street, Santa Ana, California 92706 (the "PREMISES "). The PARTIES agree that the
terms of this AGREEMENT will satisfy all of PME'S claims regarding the removal of the
architectural barriers to disabled access at the PREMISES, In order to avoid the costs, expense,
and uncertainty of protracted litigation, the PARTIES hereby enter into this Agreement as set
forth below.
RECITALS
This AGREEMENT is based on the following facts:
A. On or around March 4, 2013, PIKE addressed a letter to the CHARLES W.
BOWERS MUSEUM CORPORATION (hereinafter referred to as "BOWERS ") and the CITY
in which he notified BOWERS and the CITY of certain alleged barriers to disabled access at the
PREMISES, including, but not limited to, inaccessible parking for persons with disabilities and
inaccessible paths of travel to and throughout the PREMISES.
B. Without any admission of liability or any admission that the PREMISES do not
meet accessibility standards and codes, the CITY has agreed to undertake remedial work at the
PREMISES to improve and ensure accessibility for persons with mobility disabilities.
Page I
C. In order to avoid the cost, expense, and uncertainty of litigation, the PARTIES
have reached an agreement on PIKE'S claims regarding the removal of alleged access barriers at
the PREMISES. Attachment "A" identifies the work to be performed by the CITY as agreed to
between the PARTIES. Said Attachment is hereby incorporated by reference as if fully set forth
herein as the full and complete agreement between the PARTIES for settlement of all of PIKE'S
claims regarding the removal of accessibility barriers at the PREMISES. The PARTIES
acknowledge that there may be a deviation as it pertains to the path of travel from the South
Parking lot towards the Museum inasmuch as the Bowers Museum is listed in the Santa Ana
Register of Historical Property and is categorized as a "Landrnark." However, any change in
such path of travel must be certified and supported in any updated CASp report commissioned
by the City.
D. The PARTIES agree that the work as outlined in Attachment "A" will be
completed no later than December 31, 2015.
E. The CITY will be responsible for the path of travel over the public right of way;
BOWERS to oversee path of travel on museum grounds leading to doors.
F. Within thirty (30) days of cornpleting all items and conditions described in
Attachments A the CITY shall advise counsel for PIKE. in writing that all items have been
completed. PIKE shall then have the right to complete an inspection of the subject property by
PIKE'S representative within forty -five (45) days of being provided the Notice of Completion.
In the event that PIKE believes that the CITY has not complied with the terms of this
AGREEMENT, Counsel for PIKE will inform Counsel for the CITY of the alleged breach and
allow for thirty (30) days for a good faith negotiation of a resolution. PIKE may immediately
file a lawsuit to compel enforcement in the event that the PARTIES are unable to resolve their
Page 2
dispute within thirty (30) days of notice. In any action to enforce the terms of this
AGREEMENT, or for breach or for declaratory relief or appropriate legal or equitable relief, the
prevailing party shall be entitled to his or its reasonable attorneys' fees and costs.
G. The PARTIES acknowledge and agree that the terms of this AGREEMENT are
fair, reasonable, adequate, in their mutual best interest, and the product of joint negotiation
through counsel.
H. The PARTIES agree that this AGREEMENT satisfies all of PIKE'S claims
regarding the removal of architectural barriers at the PREMISES. The PARTIES acknowledge
that they are waiving significant legal rights and /or claims by entering into this AGREEMENT.
Each PARTY has consulted with legal counsel, has a full and complete understanding of the
terms and legal effect of the AGREEMENT, and intends to be bound thereby.
TERMS OF AGREEMENT
1. Payment: The Parties agree to settle this matter for the sum of $48,000.00. This
Settlement amount constitutes the total settlement to resolve all claims for removal of the
architectural barriers to disabled access alleged to exist at the Bowers Museum, and includes
claims for attorneys' fees and costs. The CITY as soon as practical after fill execution of this
Agreement, but in no event later than twenty (20) days thereafter, shall pay $48,000.00 via wire
transfer or check to the Metz & Harrison client trust account.
2. Releases: Except for the obligations expressly set forth in this AGREEMENT, the
CITY agrees to release and forever discharge PIKE and PIKE agrees to release and forever
discharge the CITY and their parent companies, officers, directors, shareholders, partners,
Page 3
members, agents, insurers, employees, attorneys, successors and assigns, parents, affiliates,
subsidiaries, related entities and all of their officers, directors, shareholders, partners, members,
agents, insurers, employees, attorneys, successors and assigns and each of them, from any and all
claims, demands, grievances, liabilities, debts, accounts, obligations, costs, expenses, liens,
actions or causes of action, of every kind and nature whatsoever, existing as of the date of this
AGREEMENT, whether known or unknown, anticipated or not, suspected or not, arising directly
and /or indirectly from or directly and /or indirectly connected to the AGREEMENT.
Notwithstanding the foregoing, PIKE does not hereby waive any claims for damages, attorneys'
fees, litigation expenses and costs, which have not been resolved by way of this AGREEMENT.
5. Waiver of Civil Code section 1542: The PARTIES acknowledges that he, she or it,
as applicable, is familiar with and has been advised by his, her or its, as applicable, attorney with
respect to the provisions of California Civil Code Section 1542, which provides:
A GENERAL RELEASE DOES NOT EXTEND TO CLAIMS
WHICH THE CREDITOR DOES NOT KNOW OR SUSPECT
TO EXIST IN HIS OR HER FAVOR AT THE TIME OF
EXECUTING THE RELEASE, WHICH IF KNOWN BY HIM
OR IIER MUST HAVE MATERIALLY AFFECTED HIS OR
HER SETTLEMENT WITH THE DEBTOR.
The PARTIES acknowledge that he, she or it, as applicable, may have sustained damages,
losses, fees, costs or expenses that are presently unknown and unsuspected, and that such damages,
losses, fees, costs or expenses might give rise to claims in the firture. Nevertheless, the PARTIES
acknowledge that this AGREEMENT has been negotiated and agreed upon in light of such possible
damages, losses, fees, costs or expenses and acknowledges and waives such claims. .
6. Release Effective Upon Subsequent Discovery of Existing Facts: PIKE
acknowledges and agrees that even if he later discovers facts in addition to, or different from,
Page 4
those which either he now knows or believes to be true with respect to the subject matter of this
AGREEMENT, that it is his intention to fully settle and release and forever discharge all of the
claims that are released and discharged by this AGREEMENT. The releases herein shall be, and
shall remain in effect, as full and completed releases, notwithstanding the discovery or existence
of additional or different facts. PIKE accepts and assumes the risk that such facts may be in
addition to or different from the facts now known or believed to be true and agrees that the
releases herein shall remain in all respects effective and shall not be subject to termination or
rescission by reason of any such additional or difference in fact.
7. Severability: If any term of this AGREEMENT is determined by any court to be
unenforceable, the other terms of this AGREEMENT shall nonetheless remain in full force and
effect.
8. Non - Assignment: Each PARTY hereby represents and warrants that they or it, as
applicable, has not heretofore assigned or transferred, or purported to assign or transfer, to any
person or entity any of the claims, demands, grievances, liabilities, debts, accounts, obligations,
costs, expenses, liens, actions or causes of action released by this AGREEMENT.
9. Authoritv: Each PARTY hereby represents and warrants that the party executing
this AGREEMENT is a duly authorized signatory.
10. Independent Advice: Each PARTY acknowledges and agrees that he, she or it, as
applicable, has been represented throughout the negotiation and docrunentation of this
AGREEMENT by counsel of the PARTY'S choice and has been advised by such counsel with
respect to this AGREEMENT and the effect of the releases given in this AGREEMENT. Each
PARTY further acknowledges and agrees that he, she or it, as applicable, has read this
AGREEMENT, knows its contents and effect and, in executing this AGREEMENT, has relied
Page 5
solely on their or its, as applicable, own judgment, belief and knowledge and the advice and
recommendations of such PARTY'S counsel. Neither PARTY has been induced to enter into
this AGREEMENT by any representation or statement of any other party not expressly contained
in this AGREEMENT.
11. Successors and Assigns: This AGREEMENT shall be binding upon the
successors and assigns of the PARTIES to this AGREEMENT.
12. Integration: Conditions Precedent: This AGREEMENT shall be of no force or
effect, and will be neither binding nor enforceable, unless and until the AGREEMENT has been
fully executed by the PARTIES. No other agreements, covenants, representations or warranties,
express or implied, oral or written, have been made by any PARTY to any other PARTY with
respect to the subject matter of this AGREEMENT. All prior and contemporaneous
conversations, negotiations, possible and alleged agreements, representations, covenants and
warranties with respect to the subject matter hereof are of no force or effect.
13. No Admission of Liability: Each PARTY acknowledges and agrees that this
AGREEMENT accomplishes the compromise of disputed claims and is not intended to
constitute an admission of liability, wrongdoing or error on the part of PARTY. Any liability,
wrongdoing or error is expressly denied by each PARTY to this AGREEMENT.
14. Additional Documents: In addition to the documents as provided for in this
AGREEMENT, each of the PARTIES agrees to promptly execute and deliver such additional
documents and take such other action as may be reasonably required to carry out the terms of
this AGREEMENT.
15. Titles and Captions: Titles and captions contained in this AGREEMENT are
inserted as a matter of convenience and for reference, and are not intended and shall not be
Page 6
construed to define, limit, extend or otherwise describe the scope of this AGREEMENT or any
provision of this AGREEMENT.
16. Modification and Amendment: No modification or amendment of any of the
terns or provisions of this AGREEMENT shall be binding upon any PARTY unless made in
writing and signed by such PARTY or by a duly authorized representative or agent of such
IV\._N"
17. Governing Law: This AGREEMENT shall be governed by and construed in
accordance with the laws of the State of California applicable to contracts entered into and
wholly performed within said state.
18. No Construction: No PARTY or PARTY'S counsel shall be deemed to be the
drafter of this AGREEMENT for purposes of interpreting or construing any of the provisions of
this AGREEMENT. This AGREEMENT shall be interpreted in accordance with the fair
meaning of its language and not strictly for or against any of the PARTIES to this
AGREEMENT.
19. Execution in Counterparts: This AGREEMENT may be executed on separate
counterparts and will become effective upon signature by all PARTIES upon one or more of
such counterparts.
IN WITNESS THEREOF, the following have signed this AGREEMENT on the dates
indicated below.
Page 7
RECEIVED 12(0512014 16:56
Dec 05 1405:05p Pike 714- 961 -1810 p.2
L�t�A 7 F �
ARNIE T. PIKE
ATTEST:
J MAIta ID HUIZAR
lJ Clerk of the Council
APPROVED AS TO FORM:
SONIA R. CARVALHO
City Atwwy I
.toso S� %ncltw��i�i
Cl K Assistant City Attorney
APPROVED AS TO FORM:
METZ & HARR[SON, LLP
C1 r
JC� t. A. HAD fSON -
SAR \ PE7. ', I�iiOPOUR
Attorneys for ARNM PIKE
Date;
!TySANTA A
DA VAZOS
City Manager
rig, a
B 0 W E R S
M U S E U M
Access Compliance Survey Report
August 2014
z
Bowers Museum - Bowers Museum Facility SALLY SWANSON
August 2014 ARCHITECTS, INC,
1 4154453Q 5 , F 416 445 2055
SSA Project # 14048 M $ANSOME STRUT, SWT� 1TW ' SAR FRANCISCO, CA a4 04
VJW'VV,MV ARA f I C H, COM
August 27, 2014 SSA Project #14048
SALLY SWAN ON
ARCHITECTS, INC.
August 27, 2014
Mr. Jose Sandoval, Esq.
Chief Assistant City Attorney
City of Santa Ana
20 Civic Center Plaza
Santa Ana, CA 92701
RE: Limited Access Compliance Survey Report
Bowers Museum
2002 N. Main Street Santa Ana, California
Dear Mr. Sandoval:
Please find included herewith, the Limited Access Compliance Survey Report for the above referenced
property. This report addresses the findings of a facility review that was conducted on July 29, 2014,
of the Bowers Museum and site. The review was based on the 2010 ADA Standards for Accessible
Design and the 2013 California Building Standards Code and conducted in accordance with the
disabled access review provisions of the State of California Senate Bill 1608. This review was prepared
in a response to a request disabled access received by the Consultant from the City of Santa Ana.
Please contact me at the number above or by e-mail at blee(aswanarch.com if you have any
questions.
Respectfully Submitted,
Brian H. Lee
AIA / CBO / CASp
Sr. Technical Architect
August 27, 2014 SSA Project #14048 Page 1 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
+�a +
A review of the site and public access interior areas of the building was performed on July 29, 2014.
The review has been prepared as a request received by the Consultant from the City of Santa Ana for
the property commonly known as:
BOWERS MUSEUM
2002 N. Main Street
Santa Ana, California
At the time of the review, the property was found to generally be in generally good compliance
standing summarily however, those elements reviewed and found to be in non - compliant condition
concerned the areas of improvement as follows:
➢ Building Blocks
➢ Accessible Routes of Travel
➢ General Site Elements
➢ Plumbing Elements and Facilities
➢ Communication Elements
➢ Special Rooms, Spaces, and Elements
➢ Built -In Elements
A copy of the mandated CASp Notification has been provided and is attached to this report as an
exhibit. Since non - compliant conditions were identified during the review, the site and improvements
cannot be designated as "CASp Inspected." Until any and all discovered non - compliant conditions
are corrected, determinations are provided by the appropriate Authority Having Jurisdiction (AHJ - i.e.
the Department of Justice, Building Official, or other) regarding any equivalent facilitation, hardship or
similar, and a CASp re- inspection is performed to verify completion and compliance of said
corrections, the project status is established and will remain as "CASp Determination Pending."
August 27, 2014 SSA Project #14048 Page 2 of 28
Y
4ll
r
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
A&GHITSCM INC,
A field evaluation was conducted on July 29, 2014 of the site conditions and the public areas of the
building. Weather conditions were sunny and the temperature at the time of the start of the inspection
was approximately 720 degrees Fahrenheit.
Physical measurements were taken at selected and strategic locations to observe compliance
conditions. Continuous measurements of all possible variances in all actual field conditions were not
performed and thus, it is possible that variances in the irregularity of a surface or material could occur
and reflect a non - compliant condition where an otherwise compliant condition was noted. An
example of such condition might include the width of a walkway or change in the slope of a floor
surface that might result in slight a convex (hump) or concave (bird -bath) condition where
measurements taken in all directions, locations and in a continuous manner could reflect that
dimensional requirements were non - compliant.
In addition to the above, although professional care was taken with obtaining all measurements, it is
noted that no inordinate measures were utilized to verify true line, distance, bearing, level or plumb
conditions. Measurements that are not stated in the codes as between a "minimum" and "maximum"
or that are within a specified range of dimensions are considered absolute. Such absolute dimensions
are subject to conventional industry tolerances as allowed by both the ADAAG and Title 24
requirements but do not fall under the purview of this CASp review for determination. Rather, such
determinations for acceptable tolerances are to be made by the Building Official, the Division of the
State Architect, the Department of Justice or other Authority Having Jurisdiction. An example of such
might include the issue that there is no change in level permitted within a required clear or
maneuvering space. Strict adherence could never be achieved since there are changes in level
between any materials or within a single material whether a tape measure or high -power microscope
is used.
Professional -grade equipment and instruments were used to obtain reasonably accurate field
measurements. Use of digital levels, calipers, shape- measuring gages, stop - watches, door - pressure
gages, templates and other instruments necessary to the measurement of a specific item were used
where appropriate. It is noted that no readings of sound, lighting, or color shade, contrast or index
levels were taken as part of this evaluation. Such readings require the service of an appropriately
licensed engineer or contractor to assist with such determinations where required. Examples of such
include measurements for alarm systems, elevators, lighting levels for egress systems, contrast between
surface colors, and etcetera. Metal -blade measuring tapes and digital levels were used to record the
dimensions. Since the dimensions reviewed were not of significant length and the ambient
temperature was not of significance range, no adjustments to any dimensions were made for any
expansion or calibration of any measuring device(s) at the time of the inspection. Digital equipment
was calibrated in accordance with manufacturer recommended procedures at the time of the
inspection.
August 27, 2014 SSA Project #14048 Page 3 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
AfiGHYECYB, INC.
It is noted that as part of this compliance- review that certain items regulated under the codes may or
may not have been constructed, installed, or otherwise provided at the site or the facility. Although
regulations govern the accessibility of a project by the disabled, the lack of provision of a specific code
regulated item should not necessarily cause the reader to arrive at the conclusion that the project is
not in compliance. The lack of provision may only mean that the specific regulations do not apply in
this instance or, that the AHJ may have made a determination that the specific item is not required at
this time or, that a determination of equivalent facilitation may have been previously made by the
AHJ.
This report does not attempt to identify all provisions of Federal or State codes, regulations,
determinations or policies related to a development project. Rather, the purpose of this report is to
only identify if physical barriers to access have been removed or that the required items are in
compliance with current Federal and /or State disabled access requirements. This report further does
not intend to provide any interpretations, establish policy or make any determinations. If any such
interpretation, policy or determination is found to be expressed or implied, such interpretation, policy
or determination is not valid and must not be relied upon as "fact" as it must be first confirmed by the
responsible AHJ or the DOJ prior thereto.
"The responsibility for demonstrating equivalent facilitation in the event of a challenge rests with the
covered entity. With the exception of transit facilities, which are covered by regulations issued by the
Department of Transportation, there is no process for certifying that an alternative design provides
equivalentfacilitation. "
Therefore, when an apparent item involving equivalent facilitation is found under this review, that item
will be strictly excluded from any implicit or explicit CASp certification.
When dimensions are specified by either the Federal or State regulations, they are often stated as a
"minimum" or "maximum" or they must fall within a "range" of acceptable dimensions. When no such
qualifier is given, the dimensions are to be considered as "absolute." During this review, no attempt
has been made to define if the dimension for a particular item falls within any industry- standard or
other construction tolerance limit and no such predetermined specific limits are prescribed by law. It
is the opinion of this consultant that absolute dimensions will always require some limit of tolerance
whether they are measured in fractions of an inch, a micron, or of an atom as there is never a perfectly
even surface. Acceptance of a construction tolerance is a function strictly reserved by law for the
interpretation by the Building Official, the Division of the State Architect, the Department of Justice or
other Authority Having Jurisdiction and is not a determination that a CASp is entitled to render. For that
reason, any items specified with an absolute dimension by any applicable code and /or regulation will
be considered in this review as "non- compliant" and no certification of compliancy of said work will
be able to be rendered by this reviewer. For guidance purposes however, in a September 30, 2004,
letter from the DOJ to the State of California that included a side -by -side comparison of the two codes,
the definition used by the State was considered compatible with the ADA Title III requirements and are
provided as follows:
ADAAG:
3.2 Dimensional Tolerances. All dimensions are subject to conventional building industry tolerances for
field conditions.
August 27, 2014 SSA Project #14048 Page 4 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
4
SALLY SWANSON
ARCHITECTS, WC-
ICC /ANSI A 117.1 -2003:
104.2 Dimensions. Dimensions that are not stated as "maximum" or "minimum" are absolute. All
dimensions are subject to conventional industry tolerances.
CCR, TITLE 24, PART 2:
11 B- 104.1.1 Construction and Manufacturing Tolerances. All dimensions are subject to conventional
building industry tolerances except where the requirement is stated as a range with specific minimum
and maximum end points.
In light of the immediately above definition provided in the California Building Code (CCR, Title 24, Part
2), the Division of the State Architect has issued an Interpretation of Regulations Document (DSA /AC)
IR 1 1 B -8 "Use of Predetermined Construction Tolerance Guidelines for Accessibility" (revised 1/1 /2011),
where a strong caveat is presented against use of pre- determined construction tolerances. In the IR,
the State Attorney General has stated:
"We are concerned that the local building offeials and the members of the general public, when they consult
Construction Tolerance Guidelines,...may assume that they have been adopted by a state agency and therefore,
have the force ofstate law, which they do not. Such reliance, in our view, may result in violations of the California
Building Code and, possibly, litigation against the local building officials and /or property owners. "
Added to IR 1 1 B -8 is the following quotation from a United States District Court:
""at is an acceptable `dimensional tolerance' will vary, depending in part to the purpose for the standard and
the technological capacity to closely adhere to the target dimensions."
Similar to dimensioning, the Building Official, the Division of the State Architect, the Department of
Justice (DO-1), or other Authority Having Jurisdiction are charged with the respective issues such as;
considerations and determinations relating to equivalent facilitation, readily achievable,
disproportionate cost, unreasonable hardship, structural impracticability, technically infeasible, and
the like.
The observations and findings contained herein are limited in scope. Approvals, permits, and
inspections may likely be required by the Authority Having Jurisdiction (AHJ) for any correction required
to achieve compliance. This report does not intend to address the code compliant status of non -
accessibility items either implicitly or explicitly. Always check with the AHJ for local codes and
regulations that also may apply. Appropriate legal counsel should be retained concerning any
responsibilities, exposure to liability or other risks that the property owner could encounter.
August 27, 2014 SSA Project #14048 Page 5 of 28
August 27, 2014 Bowers Museum, SSA Project #14048 SALLY SWANSON
ARCHITECTS, INC_
SCOPING
PROJECT SCOPE
This limited investigational review is prepared under the guideline provisions for disabled access
compliance as identified by the State of California Senate Bill 1608 for the project as follows:
BOWERS MUSEUM
2002 North Main Street Santa Ana, California
The report has been prepared for the stated City Attorney's Office of the City of Santa Ana.
This report is intended to be investigational and informational in nature and concerns access by the
disabled community to an existing public museum. The scope of the project has been limited, to
address the exterior and interior (public spaces only) state and federal disabled access requirements.
The property is located within the incorporated boundaries of the Santa Ana, California. The overall
site comprises several land parcels that are improved with buildings, surface -level paved parking
spaces, walkways, landscaping and other appurtenant improvements. A "remote" parking lot
(located across and to the south side of 20th Street) that is used by patrons of the facility was also
reviewed.
The site is large and relatively rectangular in shape. The museum itself, is bounded on the east by Main
Street, on the south by 20th Street, along the west with a mix of residential and commercial properties,
and to the north with commercial properties. Main Street is a 4 -lane arterial street that is provided with
full public improvements (i.e. curb, gutter and sidewalk). A site view is provided below:
GOOSIC earth f aua A
(11E 3atl
The site slopes very gently and at an angle of approximately less than five (5 %) percent overall. It is
developed with multiple buildings that are interconnected and used as part of the museum. The site
also is improved with surface -level parking area located to the north of the facility and with a detached
surface -level parking area located to the south of 201h Street.
August 27,
Page 6 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
MI
SALLY SWANSON
ANC" STECTS, INC.
Access to the site is provided for pedestrians, passenger vehicles and both small van and delivery -type
vehicles. Pedestrian access is provided along the Main Street and 20th Street frontages and from the
on -site parking area.
A regionally- connecting public transit system (bus stop) is located on Main Street and is immediately
adjacent to the remote surface -level parking area south of 20th Street.
August 27, 2014 SSA Project #14048 Page 7 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCHITECTS. INC-
The site is used as a public museum facility where the general public is commonly invited. Areas under
this review (the exterior site and interior public areas) are considered to be places of public
accommodation.
August 27, 2014 SSA Project #14048 Page 8 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
i
SALLY SWANSON
ARCHITPSVS. Mo.
The property is under public ownership and the facility is considered a place of public
accommodation. Public funds have been used for the physical development or operational programs
of this facility. Therefore, the project qualifies for review under the Title II and Title III of the Federal ADA
requirements and under Title 24 of the California Building Standards Codes with respect to requirements
for access by the disabled and for associated barrier removal.
August 27, 2014 SSA Project #14048 Page 9 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCHITECTS, INC.
All newly constructed places of public accommodation and commercial facilities must be accessible
to individuals with disabilities to the extent that it is not structurally impracticable. For additions and
alterations, the new construction requirements apply to any facility occupied after January 26, 1993,
for which the last application for a building permit or permit extension is certified as complete after
January 26, 1992. According to the DOJ, full compliance will be considered "structurally impracticable"
only in those rare circumstances when the unique characteristics of terrain prevent the incorporation
of accessibility features (e.g., marshland that requires construction on stilts).
If an entity constructs or alters the required elements of the path of travel in accordance with the 1991
ADA Standards or the UFAS before March 15, 2012, then the entity is not required to retrofit any such
elements included in the 2010 ADA Standards solely because of an alteration to a primary function
area served by a path of travel. In accordance with the California Building Standards Code
requirements, a project must comply with the code underwhich that portion of the work was permitted
and inspected and of which also received a final certificate of occupancy or other approval. Certain
'grandfather' considerations are already being addressed with regards to compliance with the 2010
CBC, the emergency adoptions by the CBSC in August 2013, and the issuance of the new 2013 CBC
requirements (effective January 1, 2014).
August 27, 2014 SSA Project #14048 Page 10 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
AfICkiYCCYS. INC-
According to the owner's representative the original portion of the museum is greater than 50 years
old and is listed as a significant historical resource. Newer portions of the facility (located to the north)
are less than 50 years old and do not qualify as historically significant. Special considerations may be
granted by the AHJ to the portions of the facility that has historical significance and where related to
such issues as the provision of equivalent facilitation.
August 27, 2014 SSA Project #14048 Page 11 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
$ALLY SWANSON
ARCH[Ti CIS, INC.
As stated previously, the property is used for the operations of a public museum. Related to the
museum function is a restaurant, gift shop and lecture hall facilities. The spacial floor area volume and
number of occupants permitted at the site requires the facility to be provided with multiple exits. The
use is not of a type that requires additional accessible parking be provided (e.g. a medical facility).
August 27, 2014 SSA Project #14048 Page 12 of 28
August 27, 2014 Bowers Museum, SSA Project 414048
SALLY SWANSON
ARCHITECTS, LNG_
The subject property slopes in a general downward direction from the north property line of the site to
the south property line. The average slope appears to be approximately less than ten (10 %) percent
as it slopes from north to south. Since the site is less than ten (10 %) percent in slope, no special
consideration for accessibility should be given for the facility.
August 27, 2014 SSA Project #14048 Page 13 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCHITECTS. INC.
Given the above facility characteristics, and in accordance with the 1991 and the 2010 ADA
Standards, readily achievable barriers limiting or preventing use by the disabled are required to be
removed to the maximum extent possible that they are readily achievable and not structurally
impracticable or technically infeasible. It is noted that although the existing property conditions and /or
proposed improvements may be accepted by a local Authority Having Jurisdiction, any determination
of 'structurally impracticable,' 'technically infeasible,' 'equivalent facilitation,' 'unreasonable
hardship' relating to disproportionate cost, or similar that is present or proposed may not provide the
level of protection as full compliance with ADA Standards and CBC. The Building Official for the AHJ
has authority for making certain determinations as they relate to the California Building Standards
Code while the DOJ, or other AHJ, may have the authority for making determinations and decisions as
they relate to the ADA Standards. That said, an advisory has been published by the DOJ in the 2010
ADA Standards for Accessible Design regarding equivalent facilitation indicating that:
"The responsibility for demonstrating equivalent facilitation in the event of a challenge rests with the
covered entity. With the exception of transit facilities, which are covered by regulations issued by the
Department of Transportation, there is no Process for certifying that an alternative design provides
equivalent facilitation. "
Therefore, when an apparent item involving equivalent facilitation is found under this review, that item
is strictly excluded from any implicit or explicit CASp certification.
August 27, 2014 SSA Project #14048 Page 14 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
qTflr s
SALLY SWANSON
ARCH"ECTS, INC�
As noted in the section above, there are certain elements that are common to access of a building or
facility by a disabled individual that are known as the "building blocks" of accessibility. The elements
are part of those items that a disabled person encounters in the "approachability" of whatever they
are attempting to access that may include, but are not limited to, approaching a door, an ATM device,
an accessible parking space or a ramp. The items may allow, inhibit or altogether prohibit access by
a disabled individual when designed and /or constructed incorrectly and thus become an
architectural barrier to the user in and of them. Such universal elements for access include but, are
not limited to, the items as listed below:
➢ Floor or Ground Conditions
➢ Changes in Level
➢ Turning and Maneuvering Spaces
➢ Clear Spaces
➢ Knee and Toe Spaces
➢ Protruding Objects
➢ Hazards
➢ Reach Ranges
➢ Operable Parts
August 27, 2014 SSA Project #14048 Page 15 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCNITcCTS, INC.
Surfaces along a ROT that are required to be accessible must be firm, stable and slip- resistant.
Requirements apply to materials used for flooring, walks, curb ramps, pedestrian crossings, ramps, stairs,
and similar surfaces. Special provisions concerning cushions, pads, backing, pile -type, installation
methods and trims also apply when carpets or carpet tiles are used. Openings along the ROT may
also create hazard in the surface and often apply within exterior conditions where site drainage is also
a factor.
Factors to consider for compliance with surface conditions include the items as follows:
• Surface material
• Surface finish
• Slip- resistance
• Contrast in color or texture
• Change in sound of surface
• Openings
Where carpets are used or where grates occur along the ROT, samples of solutions to those conditions
are depicted in the figures as follows:
CARPET SURFACES
OPENINGS IN ROT
DOOR MATS
moil A40.Y Finki PLUSH on
AFIE:. PHUMMME
August 27, 2014 SSA Project #14048 Page 16 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCHITECTS. INC.
Changes in level along an accessible ROT may not exceed ' /a" maximum vertically or Y2" maximum
when beveled at a 1:2 slope (with up to 1/4" in vertical change allowable). Vertical changes greater
than 1/2" must comply with ramp feature requirements. Certain hazards may also be present due to
changes in surface levels (i.e. drop -offs) where adjacent to the ROT.
Factors to consider for compliance with changes in levels include the items as follows:
• Changes in level within the ROT • Thresholds
• Changes in level at area adjacent to ROT • Door mats
• Floor material transitions • Gratings
Samples of solutions to the above conditions are depicted in the figures as follows:
VERTICAL CHANGE IN LEVEL
'
THRESHOLD DESIGN
1/27 MAX
P X.
VERTICAL CHANGE IN LEVEL WITH BEVEL
a
August 27, 2014 SSA Project #14048 Page 17 of 28
August 27, 2014 Bowers Museum, SSA Project #14048 SALLY SWANSON
Aaew17e0M INC.
TURNING SPACE
An accessible ROT is required to maintain specific clear and level spaces used for turning and
maneuvering. The space required is commonly considered as a circular space that is 60" in diameter
or a T- shaped space that fits within a 60" square. The leg and top of the T -shape are each 36" wide
(see figure below).
Turning spaces are allowed to overlap required knee and toe spaces and, with limitations, doors are
allowed to encroach into the required area. Turning and maneuvering spaces are subject to surface
condition requirements and they must be level (1:48 or 1:50 maximum slope in any direction and
depending upon the date of applicable regulation). The surface may not contain any abrupt changes
in level, have items projecting into the space (again with limitations) or have unmitigated hazards
present.
Requirements for turning and maneuvering spaces generally include, but are not limited to, the
following conditions and /or locations:
• Doorways
• Landings
• ROT with passing space
• ROT with door encroachment
• Constricted ROT
• Projections in ROT
Samples of required turning and maneuvering spaces are as follows:
CIRCULAR SPACE
T- SHAPED SPACE
August 27, 2014 SSA Project #14048 Page 18 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
4
SALLY SWANSON
AHCfHTECM INC-
Similar to turning and maneuvering spaces is the concept of clear space. Clear space is a floor area
that is 30" x 48" or, under given conditions is 36" x 48" or 30" x 60 ", in size. It is the space that allows
forward or parallel ( "side ") approach to a given accessible element of the facility (e.g. a lavatory or
water closet, drinking fountain, TTY telephone, sales counter, interpretive display or the like). Additional
clear space requirements apply at each side of the door (i.e. the "pull" or "push" sides). They must be
connected to an accessible ROT and they often allow encroachment under counters, sinks or other
spaces for knee and toe space. Clear spaces are, again, subject to surface condition requirements
and they must be level (1:48 maximum slope in any direction. They may not contain any abrupt
changes in level, have items projecting into the space (again with limitations) or have unmitigated
hazards present.
Details specific to clear space provision requirements may be found under the related specific sections
of the report (e.g. under doorway or sanitation requirements) however, generally applicable figures
are as shown on the page that follows:
CLEAR FLOOR SPACE
t
€ -- -- A
e �
8
r r
L
FRONT APPROACH AT AN ALCOVE
FRONT APPROACH AT ALCOVE >24" DP
August 27, 2014 SSA Project #14048 Page 19 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
PARALLEL APPROACH AT AN ALCOVE
CLEAR SPACE AT TABLES / SEATING
PARALLEL APPROACH AT ALCOVE >15" DP
I!U!!Inninim��
SALLY SWANSON
ARCHITECTS, INC.
August 27, 2014 SSA Project #14048 Page 20 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCH ITVCTR, INC.
Knee and toe space applies generally to forward approach conditions and is to be provided when a
turning or maneuvering space or a clear floor space passes under an accessible facility element.
Examples of such spaces include the area under a work or sales counter, under a lavatory or drinking
fountain, under an interpretive table display or similar type conditions.
Knee space is required to be 30" wide minimum and is defined as the area between 9" and 27" above
the finish floor (AFF). It is permitted to extend to a maximum of 25" in depth under an element. That is
not to say that an element cannot have greater than 25" in clear depth but rather, to say that only 25"
D maximum is allowed for the "required" portion thereof. Where the knee space is an extension of the
required clear space the dimensions reduce. In these conditions, the depth is limited to an 11"
projection at 9" AFF and 8" at a point 27" AFF. Between 9" and 27" AFF, the knee space clearance
reduces on a straight -line ratio of 1 "D:6 "H (see the graphic below). As noted above, open spaces
provided beyond the required spaces are not permitted to be included within the clear or knee space
allowances.
Toe space is defined as the area from 0" to 9" AFF. Similar to knee space, the toe space may extend
to a maximum of 25" in depth under an element. Where part of the required clear floor space, the
depth of the toe space is limited to a 6" projection beyond the required and available knee space.
Therefore, if conditions permit, the toe space is limited to 11" (for the knee space) plus an additional
6" for the toe space or, 17" maximum total.
Section 4.2.3 of the 1991 Standards and Section 304.3 of the 2010 Standards allow turning space to be
either a circular space or a T- shaped space. Section 304.3 permits turning space to include knee and
toe clearance complying with section 306. Section 4.2.3 of the 1991 Standards did not specifically
permit turning space to include knee and toe clearance.
The Department of Justice recognizes that the technical specifications for T- shaped and circular
turning spaces in the 1991 and 2010 Standards, which are based on manual wheelchair dimensions,
may not adequately meet the needs of individuals using larger electric scooters. However, there is no
consensus about the appropriate dimension on which to base revised requirements. The Access Board
continues to conduct research to study this issue in order to determine if new requirements are
warranted.
The Department plans to wait for the results of this study and action by the Access Board before
considering any changes to the Department's rules. The Department has issued a statement indicating
that covered entities may wish to consider providing more than the minimum amount of turning space
in confined spaces where a turn will be required. Appendix section A4.2.3 and Fig. A2 of the 1991
Standards provide guidance on additional space for making a smooth turn without bumping into
surrounding objects.
August 27, 2014 SSA Project #14048 Page 21 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
KNEE AND TOE SPACE
August 27, 2014 SSA Project #14048 Page 22 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SALLY SWANSON
ARCHITECTS, INC_
Objects that protrude into the accessible ROT must be in some manner protected from causing injury
to individuals moving along the path. Protrusions are not permitted beyond a projection that is greater
than 4" as measured at a height of between 27" and 80" (84" for residential occupancies) AFF. Two
exceptions do apply that include the projection of handrails of up to 41/2" for handrails and door closers
and door stops shall be 78" minimum AFF. The required clear width of a ROT shall not be reduced by
any protruding objects.
When objects are mounted on a post, the maximum permitted overhand is again 4" unless there is a
physical barrier provided that reduces the clear height of the bottom of the object to less than 27" or
above 80" AFF. Where objects, such as an 'open" underside of a stair or other object allows an
individual to enter an area where the overhead projection is less than 80" or greater than 27" AFF it is
required to be protected with a physical barrier such as a guardrail or other acceptable barrier.
PROTRUDING OBJECT LIMITATIONS
POST- MOUNTED OBJECTS
in'o
August 27, 2014 SSA Project #14048 Page 23 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
SIDEWALK OBSTRUCTIONS
FACE Ot
CURB
STREET
PACE
CURB
sm
REDUCED VERTICAL CLEARANCES
F:�
u
August 27, 2014 SSA Project #14048 Page 24 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
Used in conjunction with the concepts of clear space forward and parallel approach. Reach ranges
are those limitations on spaces that allow a disabled individual the ability to reach an item on a shelf
or the operation of such items as a thermostat or an ATM device. Consideration of reach limitations
is also a factor when considering if the reaching movement involves an unobstructed reach or, the
reach over an obstruction such as a countertop.
ADA UNOBSTRUCTED FORWARD REACH
CBC UNOBSTRUCTED FORWARD REACH
(SIMILAR TO ADA)
ADA OBSTRUCTED HIGH FORWARD REACH
(B)
(b)
CBC OBSTRUCTED FORWARD REACH
(SIMILAR TO ADA)
NOTE:
X SHALL Be LESS THAN OR EQUAL TO 25 INCHES Z SHALL BE GREATER
THAN OR EQUAL TO X. WHEN X IS LESS THAN 20 INCHES, THEN Y SHALL
BE 48 INCHES MAXIMUM, WHEN X 13 20 TO ?S INCHM THEN Y 3HAL4 Be
44 INCHES MAXIMUM,
August 27, 2014 SSA Project #14048 Page 25 of 28
August 27, 2014 Bowers Museum, SSA Project #14048
ADA UNOBSTRUCTED SIDE REACH
ADA / CBC OBSTRUCTED SIDE REACH
CBC SIDE REACH (SHELVES)
255.010
CBC SIDE REACH (CLOSETS)
SALLY SWANSON
AnGHIYEGTS, INC.
August 27, 2014 SSA Project #14048 Page 26 of 28
August 27, 2014 Bowers Museum, SSA Project 414048
$AMY SWANSON
ARCHITeCTS, 1 %C.
Wherever items require a disabled person to operate a device, that device must be located along an
accessible ROT and the allowable heights of the device may vary depending on if a front approach
(forward reach) or side approach (side reach) range applies. Operation of the item shall be able to
be performed with the use of one hand and cannot require tight grasping, pinching of the item, or
twisting of the wrist. The maximum for required to operate a device is 5 pounds of force with exceptions
such as operating a fire - resistant rated door or the operation of a gasoline pump nozzle.
August 27, 2014 SSA Project #14048 Page 27 of 28
Bowers Museum - Bowers Museum Facility- ACS
i
r'
SSA Project # 14048
_ SALLY SWANSON
AugusT2014 ar:cnirecrs, INC. .�s,
aorv?i "Al .z"'MAN' t<"� "*,4"Fi1f
Bowers Museum Access Compliance Survey Report Navigation and Legend
Report Format
PY Y Y ; T '"C (P Q
Bowers
Mus um Acg6ss Complianci Survey ReiVrt
Ca
pus: Bow rs Mu s um Faci y Part: xterior
Floor: On-Site
Ad
ress:2002 North ain St, Vanta Ana CA 92706
4. As- Built:
Existing conditions /dimensions.
Existin Architect al Barrier
Description of steps necessary to remove barrier and, if applicable, an interim solution or notes.
Its
No. and N me and roposed S uh.n Codes /Mitigation Q
Unit
- REF: data shown for reference only [scope of work related to or covered by other item]:
i4?�`L,iig4
gip( �tr m_aeseairrngtS��te fb�Er�ti
-NT: non - typical problem or solution.
2311 =01.
11585 Sldewafl{
accessibility codes.
-As -Built Des crlp on: PCODE EA05 50
JOB
Cross slope mor than 1/4 ".12" (2 %). ADAAG 443
Unit of measurement used to compute cost estimate. LF= linear feet; SF= square feet: JOB =lump sum.
CSAS
112913.3.3
-As- built. 3.5% ADA 2010 502.4
- Proposed Solution:
Modify cross slope.
Notes: Maintain area.
1. Item Number:
Number corresponding to the number on the Barrier Location Map which identifies the general location
of identified barriers.
2. Item Name:
Describes the barrier location I item title (e.g.: parking lot, room name).
3. As -Built Description:
Description of identified barrier based on applicable accessibility codes.
4. As- Built:
Existing conditions /dimensions.
5. Proposed Solution:
Description of steps necessary to remove barrier and, if applicable, an interim solution or notes.
6. Codes I Info:
- PCODE: specifies the relevant SSA database code. Database code plus suffix:
- REF: data shown for reference only [scope of work related to or covered by other item]:
-NT: non - typical problem or solution.
- ADAAG, ADA 2010, PROW and CSAS: specifies applicable sections of Federal and State
accessibility codes.
7. City:
Number of units required.
8. Unit:
Unit of measurement used to compute cost estimate. LF= linear feet; SF= square feet: JOB =lump sum.
9. ID No: Specifies Facility Number, Area Number: 1= Interior/ 0 =Exterior, and Part/ Floor Number.
SSA Project # 14048 _ SALLY SWANSON �^
August2014 ARCHITECTS, INC.
Bowers Museum - Bowers Museum Facilitv- ACS
N Uff on W
ABA
Architectural Barriers Act
Lav
Lavatory
ADA
Americans With Disabilities Act
lbs
Pounds
ADAAG
ADA Accessibility Guidelines
LF
Linear foot
ADACO
ADA-Coordinator
Lib
Library
AFF
Above finished floor
MOD
Modernization project
SCS
Baby Changing Station
MGM
Method of mitigation
CA
State of California
MID
Master priority
GSAS
CA State Accessibility Standards
MRR
Men's restroom
ANSI
American National Standards Institute
NA.R.
No action required
C.T.P.
Contact third party
NT
Non-typical
cl
Center line
OX.
On center
CMGR
City Manager
OIR
Official responsible
D-A_
Designated accessible
P.A.
Physical alteration
DOS
Diaper changing station
P.M.
Program modlifcallon
OF
Drinking fountain
POM
Plant Operations & Maintenance
Dlr.
Director
POT
Path of travel
E.F.
Equivalent facilitation
PROW
Public Right-cf-Way
EHD
Electric Hand Drier
PTD
Paper towel dispenser
FO
Fire Chief
PW
Public Works
FD
Finance Director
City
Quantity
FDC
Facilities Design & Construction
REF
Reference
FTD
Feminine Tissue Dispenser
ROB
Rear grab bar
FHAAG
Fair Housing Act Accessibility Guidelines
BCD
Seat cover dispenser
Fig-
Figure
SID
Soap dispenser
FM&O
Facilities, Maintenance & Operations
sec-
Second
FND
Feminine napkin disposal
SF
Square foot
FTD
Feminine tissue dispenser
SGB
Side grab bar
Gov-
Government
tbd
To be determined
HQ
Headquarters
TPD
Toilet paper dispenser
HWB
Hazardous waste bin
UFAS
Uniform Federal Accessibility Standards
PC
International Building Code
WC
Water closet
CC
international Code Council
WRR
Women's restroorn
ISA
International Symbol of Accessibility
WT
Water treatment facility
JOB
per one job (lump sum)
WWT
Waste water treatment facility
SSA Project 9 14048 SALLY SWANSON ^,J
Augusi-2014 ARCHITCCTS, INC.
Bowers Museum - Bowers Museum Facility- ACS
SSA Project # 14048 SALLY 8WANSON v
August 2014 AHONIrEC4s, INC.
Bowers Museum Access Compliance Survey Report
Address: 2002 N Main St, Santa Ana, CA 92706
:acuity °' Bowers Museum ?rea 'Exterior �-
1 North Lot Van Space (East)
2 POT along North Lot
3 North Lot Acc Spaces (4)
4 South Lot
5 POT From South Lot to Historical Entrance
6 POT From Historical Entrance to Cultural Arts Entrance
7 Historical Plaza
8 Main Entrance
9 Side Entrance
10 Ramped Exit Main St.
0 Auditorium
1 Auditorium Lobby
2 Auditorium Lobby Women's Restroom
3 Auditorium Lobby Men's Restroom
4 Lee Court
5 Ancient Art of China - East West Bank Gallery
6 Anderson Hsu Tu Gallery
7 Thompson Foyer
8 Thompson Foyer - Women's RR
9 Thompson Foyer - Men's RR
10 Main Entrance Lobby
11 Chandler Gallery
12 Freedman Foundation Gallery
13 Muth Wing
14 Ruth Gallery
15 Ettinger Gallery
16 Elevator Adjacent to Ruth Gallery
17 Restroom Lobby
18 Unisex Restroom
19 Main Gallery
20 Gift Shop
21 Tangata Restaraunt
August 25, 2014 Sally Swanson Architects, Inc. Project#14048 ItemNames - Pagel
w
i
in
ae
SFS'ti�v
8R
y
1
�y
R
a
e•
Moil
d
1
Y m
�
Y
fi Y
71 Y..,. `..
..
g
fi
a
aka „. y
..
Y§
}' 8
....
IM
..
An
w.�
\\
!§
\:
`)f
\
i`
ff)
--
.\\\
C)
/{
■■
co
■■
/\
\\
mow«
/u
\f
< �
j
O
AN
IN
E }
\ )
I I
/ (
/ `2
)/
LL
/ 0a
9 �)
&
ff)
IN
E }
\ )
I I
/ (
/ `2
)/
LL
/ 0a
9 �)
&
Bowers Museum - Bowers Museum Facility- ACS Report
SSA Project # 14048 _ SALLY SWANSON 6"
August2014 ARCHITECTS, INC.
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Cross done
1fo • As -Built Description: PCODE EE07
Cross slope more than 1":48" (2.083%).
ADAAG 4.3,7
• As- Built: 3.0% ADA 2010 403.3
• Proposed Solution:
Modify cross slope at change of direction along CBC 2010 1133B.7.1.3
walk. CBC 2013 11B -403.3
Curb Ramp
fog • As -Built Description:
Less than 48" level space at top and 1:12 flared
sides not provided.
• As- Built., 15 " -48"
• Proposed Solution:
Extend top landing to provide 48" depth for full
width of ramp.
toe As -Built Description:
Detectable warning not provided where pedestrian
crosses vehicular area.
• Proposed Solution:
Provide detectable warning surface (i.e. in -line
truncated domes) at regular curb ramp.
f11 • As -Built Description:
Curb ramp: 12" wide grooved border not provided
(CA requirement only).
PCODE EH05B
ADAAG 4.7.5; Fig.12(a)
ADA 2010 406.4
CBC 2010 1127B.5.4
CBC 2013 1111- 406.5.3
PCODE EH07A
ADAAG 4,7,7
ADA 2010 705.1
CBC 2010 1127B.5.7
CBC 2013 11B- 705.1.2.2
PCODE E1107B
CBC 2010 1127B.5.6
• As- Built: 11" CBC 2013 11B- 406.5.11
• Proposed Solution:
Provide 12" wide grooved border per CBC when
remodeling.
32 SF
1 JOB
1 JOB
1
August 27, 2014 Sally Swanson Architects, Inc. Projectn 14048 SurveyData -Pagel
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Floor or Ground Surfaces
107 • As -Built Description:
PCODE EA05
Polliaat of accessible parking space along curb has
slope greater than 114 ":12" (2 %). ADAAG 4,63
ADA 2010 502.4
• As-Built 2.3-2,5%
• Proposed Solution: CBC 2010 1129B.3.3
Modify slope at accessible parking space. CBC 2013 10 -502.4
Parking
aos • As -Built Description.
PCODE EA02A
Accessible parking space smaller than 8' wide (CA
only: 9' X 1&').
ADAAG 4.63
ADA 2010 5022
• AS-Built: $`11" wide
• Proposed Solution:
CBC 2010 112911.3.1
Re- stripe creating full -width parking space and
CBC 2013 1113-502.2
provide Y wide min. aisle adjacent to parking
space. Relocate van space to westerly group of
accessible parking.
• Notes:
overall space curb to curb 1" short
103 • As -Built Description:
PCODE EA04D
The words "NO PARKING" not painted(faded) on
the ground within loading and unloading access
CBC 2010 1129B.3.1
aisle (12" nun high white letters), located so that it
is visible to traffic enforcement officials (required
CBC 2013 I IR- 502.3.3
in CA only).
As-Built: Wording is faded.
• Proposed Solution:
Provide the words "NO PARKING" in each access
aisle, painted in 12" high letters, when altering area.
�m • As -Built Description:
Parking sign is not located at 60" mix. above the PCODE EA04H
finish floor or ground surface measured to the ADAAG 4.6.4
bottom of the sign. ADA 2410 502.7
As- Suitt: 40" CBC 2010 1129B.4
• Proposed Solution: CBC 2013 11B -502.6
Provide compliant reflectorized sign at 60" min.
high.
• Notes:
133 spaces
6 accessible
Ivan
30 SF
1 JOB
1 JOB
2 JOB
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s, in C. f r pi e c t 4 14048 Survey Data - Page 2
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
106 • As -Built Description:
CA only: The area within the blue borderlines not
marked with hatched lines a maximum of 36" on
center.
• As- Built: One striping line missing
• Proposed Solution:
Restripe to provide hatched lines at 36" on center
within access aisle.
Parking9ignage
¢02 • As -Built Description
No "Tow Away" sign at parking lot entrance
(required in CA only).
• As- Built: Tree is blocking view of existing
sign.
• Proposed Solution:
Provide additional "Tow Away" sign at parking lot
entrance.
104 • As -Built Description:
Sign for "Van Accessible" space is located at stall
where the van accessible aisle is located on the
driver side of the vehicle.
• Proposed Solution:
Replace with compliant sign.
Notes:
Remove van sign from right side
Codes I Mitigation Info
PCODE EA04I
CBC 2010 1129B.3.1
CBC 2013 IIB- 502.3.3
PCODE EA04C
CBC 2010 1129BA
CBC 2013 1111- 502.81
PCODE EA04EREF
ADA 2010 502.3.4
CBC 2010 1.1.2911.4
CBC 2013 11B- 502.3.4
Qty Unit
1 JOB
1 JOB
[.7M
27 2014 S a l l y S w a n s o n A r c h i t e c t s, Inc. P r o j e c t 8 14048 Survey Data -Page 3
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Detectable Warning
ate • As -Built Description.
36" wide band of truncated domes not provided at
walkway or crossing adjoining a vehicular way, if
surfaces are not separated by a curb, railing, or
other element.
• As- Built: Sloped walls to main gate.
• Proposed Solution:
Provide 36" wide, contrasting color, band of
truncated domes between pedestrian and vehicular
area
Q&
113 • As -Built Desorption:
Surface of'required maneuvering clearance at gater
slopes more than 1l4 ":12" (2.0 °l0).
• As -Built 2.3 -2.4%
• Proposed Solution:
Modify surface slope at gate.
Notes:
Determine if gate remains open during regular
business hours.
Route Sign
f27 • As -Built Description:
No sign by inaccessible route directing persons to
an accessible route.
• Proposed Solution:
Provide directional sign.
• Notes:
Determine if gate is open during regular
business hours and provide appropriate signage
if required.
PCODE EG09
ADAAG 4,29.5
CBC 2010 113311A.5
CBC 2013 1111- 705.1.2.6
PCODE B}11
ADAAG 4,13,6
ADA 2010 404.2,4.4
CBC 2010 1133B.2.4
CBC 2013 1111- 4114.2.4
PCODE SA20
ADAAG 35.163(b)
ADA 2010 216.3
CBC 2010 112713.3
20 LF
80 SF
August 27, 2014 S a l l y S tc a n s o n Architects, 1 n c. P r of e c t# 14048 Survey Data - Page 4
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Codes I Mitigation Info
age
123 As -Built Description:
PCCDE SA14
No signs at non - accessible entrances directing
persons to an accessible entrance of the building.
ADAAG 4.1.2(7)(c)
- Proposed Solution.
ADA 2010 216.6
Provide directional signage to indicate route to the
DEC 2010 1127B3
nearest accessible entrance.
- Notes:
If side entrance is used at North lot during
business hours, designate North gate entrance
with tSA.
Qty Unit
1 JOB
August 27, 2014 S o l i ) , .S w a n t o n A r c h i P e c l s, In c, P r o j e c t# 14048 Survey Data - Page 5
Bowers Museum Access Compliance Survey Report 1-0-1
Facility: Bowers Museum Part: Exterior Floor: On-site
Address: 2002 N Main St, Santa Ana, CA 92706
117 • As -Built Description
Slope greater than 1.12 (8.3%).
• As-Built.' Right ramp 890/0
• Proposed Solution:
Demolish existing and provide new curb ramp.
As-Built Description:
Slope greater than 1:12 (8.3%).
• As-Buttt: 8.8-9.0%
• Proposed Solution
Demolish existing and provide new curb ramp.
Ila • As-Built Description:
Cross slope greater than 2%
• As-Butt: 2.3%
• Proposed Solution:
Demolish existing and provide new curb ramp,
PCODE E1102A
ADAAG 4.7,2
ADA 2010 406.1
CBC 2010 1127B,53
CBC 2013 1113-406.2.1
PCODE EB02A
ADAAG 4,7.2
ADA 2010 406.1
CBC 2010 1127B,53
CBC 2013 1IB-406.2.1
PCODE EI-102F
ADAAG 4.8.6
ADA 2010 4053
CBC 2010 1133M.3.1
CBC 2013 1 IB-406.5.7
1 JOB
1 JOB
1 JOB
August 27, 2014 Sally Siianson A, chilects, lnc- Projecilf 16048 Survey Data - Page 6
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
115 As -Built Description:
Detectable warning not provided where pedestrian
crosses vehicular area.
• Proposed Solution:
Provide detectable warning surface (i.e. in -line
truncated domes) at regular curb ramp.
123 As -Built Description:
Detectable warning not provided where pedestrian
crosses vehicular area.
• Proposed Solution:
Provide detectable warning surface (i.e. in -line
truncated domes) at regular curb ramp.
119 As -Built Description.:
Curb ramp: 12" wide grooved border not provided
(CA requirement only).
• As- Built. 11"
• Proposed Solution:
Provide 12" wide grooved border per CBC when
remodeling.
Codes I Mitigation Info
PCODE EH07A
ADAAG 4,7.7
ADA 2010 705.1
CBC 2010 112711.5.7
CBC 2013 1111- 705.1.2.2
PCODE EH07A
ADAAG 4,7.7
ADA 2010 705.1
CBC 2010 1127B.5.7
CBC 2013 1111- 705.1.2.2
PCODE EH07BNT
CBC 2010 1127B.5.6
CBC 2013 1111- 406..5.11
Eloor or Ground Surfaces
125 As -Built Description:
Accessible parking space has slope greater than PCODE EA05
1/4 ":12" (2 %). ADAAG 4.6.3
• As- Built: 2,7.4.3% along back of spaces ADA 2010 502.4
• Proposed Solution: CBC 2010 1129B.3.3
Modify slope at accessible parking space. CBC 2013 11B -502.4
• Notes:
Also paint and striping is faded.
Qty Unit
1 JOB
1 JOB
4 JOB
120 SF
August 27, 2014 Sally Swanson Architects, Inc. Project # 14048 Survey Data - Page 7
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. B Name and Proposed Solution Codes I Mitigation Into
Gale
116 As -Built Description:
PCODE IDII
Surface of required maneuvering clearance at door
zu
slopes more than 114 ":12" (10 %). ADAAC 4.13.6
• As- Buttt: Service entrance/bottom landing:
2.3%
• Proposed Solution:
Modify surface slope at gate.
• Notes:
Service Gate
Parking
122 • As -Built Description.:
The words "NO PARICING" not painted on the
ground within loading and unloading access aisle
(12" thin high white letters), located so that it is
visible to traffic enforcement officials (required in
CA only).
• As- Built: Paint is faded
• Proposed Solution:
Provide the words "NO PARKING" in each access
aisle, painted in 12" high letters, when altering area.
121 • As -Built Description:
Parking sign is not located at 60" min. above the
finish floor or ground surface measured to the
bottom of the sign.
• As- Built: 40"
• Proposed Solution:
Provide compliant reflectorized sign at 60" min.
high.
Parking fit nage
124 • As -Built Description:
CA only: Additional Sign or additional language
below the symbol of accessibility stating
"Minimum Rine $250" not provided.
• Proposed Solution:
Provide compliant parking signage that includes
fine information at each accessible parking stall.
ADA 2010 4042.4.4
CBC 2010 1133B1.4
CBC 2013 IIB- 404.2.4
PCODE EA04D
CBC 2010 1129113.1
CBC 2013 11B- 502.3.3
PCODE EA04H
ADAAO 4.6.4
ADA 2010 5017
CBC 2010 11299.4
CBC 2013" 1111-502.6
PCODE EA04G
CBC 2014 1129BA
CBC 2013 1113- 502.61
Qty Unit
20 SF
1 JOB
4 JOB
6 JOB
August 27, 2014 Salty Sir anson Archr tec is, Inc. Project.°. -. 14048 Survey Data - Page 8
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Curb Ramn
140 • As -Built Description:
Transition from ramp to gutter does not have a
PCODE FH02DRFF
smooth transition.
ADAAG 4.7.2
ADA 2010 406.2
• As- Built.' 0.75"
• Proposed Solution:
CBC 2010 1133B.5.3
Provide smooth transition.
CBC 2013 11B- 406.5.8
136 • As -Built Description:
Maximum slope of adjoining gutters, street surface
at bottom of ramp exceeds 5% (1:20).
• As- Built., 10%
• Proposed Solution:
Modify road /gutter slopes. Demolish existing and
provide new curb ramp when resurfacing rough
pavement at parking.
t3s • As -Built Description.:
Detectable warning not provided where pedestrian
crosses vehicular area.
• Proposed Solution:
Provide detectable warning surface (i.e. in -line
truncated domes) at regular curb ramp,
138 • As -Built Description:
Curb ramp: 12" wide grooved border not provided
(CA requirement only).
• Proposed Solution:
Provide 12" wide grooved border per CBC when
remodeling.
PCODE BH02E
ADAAG 4.7.2
ADA 2010 406.2
CBC 2010 1127B.5.3
CBC 2013 11B- 4116.5.8
PCODE EH07A
ADAAG 4.7.7
ADA 2010 705.1
CBC 2010 1.127B.5.7
CBC 2013 10- 705.1.12
PCODE EH07B
CBC 2010 1127B.5.6
CBC 2013 11B- 406.5.11
REF
1 JOB
1 JOB
1 JOB
August 27, 2014 S a l l y S w a n s o n A i c h l t e cis, Inc. P r o j e c t M 14048 Survey Data - Page 0
Sowers Museum Access Compliance Survey Report
Facility: Sowers Museum Part: Exterior Floor: On -site
Address: 2402 N Main St, Santa Ana, CA 92706
• As- Built: Rough irregular surface
• Proposed Solution:
Modify slope at accessible parking space.
uar • As -Buiit Description
Accessible parking space has slope greater than
1/4 ":1.2" (2 %).
• As- Built: Gutter within 18' aisles. 10%
Proposed Solution:
Modify slope at accessible parking space,
Idea 'fication
129 • As -Built Description:
Sign for accessible parking space is missing or non -
compliant.
As- Built. 2 of the 4 signs missing
• Proposed Solution:
Provide compliant parking signage.
Minimum Number
tsr • As -Built Description:
At parking tot with 10 1- 15 0 spaces, the number of
accessible spaces is less than required by code; 5
spaces required.
• Proposed Solution:
Provide required accessible parking spaces with
signs including a minimum of one van space.
• Notes:
127 tot
4 spaces
2 van signs, 0 van spaces
5' aisles
ADA 2010 502.4
CBC 2010 1129B3.3
CBC 2013 11B -502.4
PCODE EA05REF
ADAAG 4.6.3
ADA 2010 502.4
CBC 2010 11298.3.3
CBC 2013 11B -902.4
PCODE EA04B
ADAAG 4.6.4
ADA 2010 502.6
CBC 2010 112913.4
CBC 2013 1113-502.6
PCODE EA01E
ADAAG 4.1.2(5)*
ADA 2010 208.2
CBC 2010 Tbl, 1113-6
CBC 2013 1113-2081 Tbl. 1113
-208.2
1i3
2 JOB
JOB
August 27, 2014 S a l t y S ,» a r s o n A r c h i t e c Is, I n c . Project # 14048 Survey Data -Page 10
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior
Address: 2002 N Main St, Santa Ana, CA 92706
Floor: On -site
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes i Mitigation Info Qty Unit
Parking
134 • As -Built Description: REF
Accessible parking space smaller than 8' wide (CA PCODE EA02AREF
only: 9'x 18'), ADAAG 4,6.3 "e „3, v rt,
kr e�na '
• As- Built: Striping faded ADA 2010 502.2
• Proposed Solution: CBC 2010 11298.3.1
Modify parking space(s) to create accessible space. CBC 2013 IIB -502.2
130 As -Built Description:
Disabled persons must wheel or walk behind parked PCODE EA03
car(s) other than their own. ADAAG Fig.9
• Proposed Solution: ADA 2010 502.3
Relocate parking and provide curb ramp to CBC 2010 1129B.3.1
accessible route. CBC 2013 IIB- 502.7.1
135 • As -Built Description: PCODE EA04DREF
The words "NO PARKING" not painted on the
ground within loading and unloading access aisle CBC 2010 1129B.3.1
(12" min high white letters), located so that it is CBC 2013 11B- 502.3.3
visible to traffic enforcement officials (required in
CA only).
• As- Built: Striping faded
• Proposed Solution:
Provide the words "NO PARKING" in each access
aisle, painted in 12" high letters, when altering area.
Parking Sig_ gnage
132 • As -Built Description:
Sign for "Van Accessible" space is located at stall PCODE EA04E
where the van accessible aisle is located on the ADA 2010 502.3.4
driver side of the vehicle. CBC 2010 1129B.4
• Proposed Solution: CBC 2013 I IB- -502.3.4
Remove the words "Van Accessible" from existing
sign at non van space.
1 JOB
REF
1 JOB
August 27, 2014 Sally Swanson Architects, Inc. P r o j e c t N 14048 Survey Data - Page 11
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Parr Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Codes I Mitigation Info
Qty Unit
131 • As -Built Description:
PCODE EA04G
4 JOB
CA only: Additional Signor additional language
INMI_Z'A
below the symbol of accessibility stating
CBC 2010 1129B.4
`_
"Minimum Fine $250" not provided.
CBC 2013 118- 5016.2
• Proposed Solution:
Provide compliant parking signage that includes
fine information at each accessible parking stall.
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s, Jac. P r o j e c i g 14048 Survey Data - Page 12
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Public Righ t of Way
142 • As -Built Description: REF
143
FEE
Srn�naue
• As -Built Description: PCODE SA01 1 JOB
Exterior signage at inaccessible entrances to
provide direction to accessible entrances is missing ADAAG 4,1.2(7)(c) �.
or noncompliant. ADA2010 216.6i+iatis 1=4'
• As -Built Directional route needed to main CBC 2010 1117B.5.8.1.2
ace. entrance
• Proposed Solution:
Provide signage sufficient to guide persons to
accessible entrances.
Walk
• As -Built Description:
PCODE EFIO
Walk: Irregular surface along walkway.
ADAAG 4,5,2
• As- Built: Cracks & uneven surfaces
ADA 2010 303.1; 302.1
• Proposed Solution:
Repair surfaces where necessary. To infill cracks
CBC 2010 1133B.7.1
greater the 0.5" wide and surfaces with cross slopes
CBC 2013 11B- 303.1; 11B -302.1
greater than 1:48.
60 SF
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s, Inc. P r o j e c 14 14048 Survey Data - Page 13
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
6 +POT From Historical Entranee`,ta CuitUral Arts Entrance
CroSs Slope
146 • As -Built Description: PCODE CF07 400 SF
Cross slope more than 1 "AS" (2.083 %).
ADAAG 4.3.7
• As -Built: 2.3 -5.6% around drainage ADA 2010 403.3
• Proposed Solution: .",.
Modify cross slope, CBC 2010 113311.7.1.3
CBC 2013 116 - 40.3.3
14e • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
PCODE >;T07
sides (not required at curb ramps or adjacent to
ADAAG 4,3.7
• As -Bull[ 3.3%
ADA 2010 504,6
• Proposed Solution:
ADA 2010 403.3
Modify cross slope.
CBC 2010 11338,7.1.3
• Notes:
CBC 2013 1111-403.3
2 tipper panels
149 • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
PCODE EF07
sides (not required at curb ramps or adjacent to
ADAAG 4.3,7
• As- Built- 3.2 °a
ADA 2010 504,6
• Proposed Solution:
ADA 2010 443J
Modify cross slope.
CBC 2010 113311.7.1.3
Provide new handrail for each side including
CBC 2013 118.403.3
Han�ils
s11 • AS -Built Description:
Handrail not provided at stairs, required on both
PCODE LD01
sides (not required at curb ramps or adjacent to
ADAAG 4.8.5 & 4.9.4
seating areas).
ADA 2010 504,6
• As- Built: no side rails
CBC 2010 11338.4.1.1 & .5.5
• Proposed Solution:
CBC 2013 118 -505.2
Provide new handrail for each side including
extensions. Modify center rail tp provide 12"
extentions.
48 SF
32 SF
10 LF
August 27, 2014 So l I y S w a n s o n A r c h i le c is, In c. P r o f e c t ff 14048 Survey Data - Page 14
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Route Sign
iae - As -Built Description:
PCtrDE SA20
No sign by inaccessible route directing persons to
an accessible route.
ADAAG 35.163 (b)
• Proposed Solution:
ADA 2010 216.3
Provide directional sign.
CBC 2010 1127B.3
Ton & Bottom Extension at Stairs
312 • As -Built Description:
PCCDE ED06
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
ADAAG 4.9.4 (2)
sloped, plus 12" minimum horizontally beyond the
ADA 2010 505.10.2; 505.103
bottom nosing,
CBC 2010 1133B.4.2.2
• Proposed Solution:
CBC 2013 iiB- 505.10.2; 11B
Extend stair handrail at top and bottom.
- 505.10.3
Tread Surface
3113 • As -Built Description:
7 of the tread does not have compliant
PCCDE ECO2
The leading �" p
visual contrast of dark--omrlight or light -on- -dark ADA 2010 504.4
from the remainder of the tread. CBC 2010 1133B.4A
• Proposed Solution: CBC2013 rlB- 504.41
Provide contrasting color stripes at all exterior stair
treads.
1 JOB
IIm.
48 LF
August 27, 2014 S a l l y S n, a n s o n A r c h i t e c t s, Inc. P r o J e c i 8 14048 Survey Data - Page 15
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Into
3YI'dh
147 • As -Built Description: PCODE EFIONT
Walk: Irregular surface along walkway.
AbAAG 4,5,2
• As- Built: Some cracks and uneven surfaces
ADA 2010 303.1; 3421
around drain.
• Proposed Solution: CSC 2010 1133B.7.1
Repair surfaces where necessary. Provide new drain CBC 2013 1 iB- 303,1, 1113 -302.1
cover mesh to provide smooth surface.
• Notes;
Also; Drain grating covering large openings in
grating have sunken into openings creating
uneven surfaces. Replace cover to prevent level
changes and openings more than 0.5"
Qty Unit
26 SF
August 27, 2014 Salty Swanson Architects, Inc. ProJecta 14048 Survey Date -Page 16
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Cross Slone
lea • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
PCODE EF07
floor: Fountain is not accessible to individuals who
ADAAG 4.3.7
• As- Built: 3.3 -9%
ADA 2010 403.3
• Proposed Solution:
CBC 2010 1115B.4.6.1
Modify cross slope.
CBC 2010 1133B.7.1.3
• Notes:
CBC 2013 11B -403.3
compound level changes. uneven stone in patio.
To drinking fountain.
155 • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
PCODE EFW
ADAAG 4.3.7
• As- Built: 3.5%
ADA 2010 403.3
• Proposed Solution:
Modify cross slope.
CBC 2010 1133B.7.1.3
• Notes:
CBC 2013 11B -403.3
Directional sign
Drinking Fountain
156 • As -Built Description:
Where only one drinking fountain is provided per
PCODE IAOIA
floor: Fountain is not accessible to individuals who
ADAAG 4.1.3(10)(a)
use wheelchairs, or to those who have difficulty
ADA 2010 211.1
bending or stooping.
CBC 2010 1115B.4.6.1
• As- Built: Non compliant drinking fountain.
• Proposed Solution:
Provide additional fountain or hi -lo combination
fountain at accessible location.
Handrails
153 • As -Built Description:
Handrail not provided at stairs or ramp, required on PCODE ED01
both sides (not required at curb ramps or adjacent to ADAAG 4,8,5 & 4.9.4
seating areas). ADA 2010 504.6
• Proposed Solution: CBC 2010 1133B.4.1.1 & .5.5
Provide new handrail for each side including CBC 2013 1111-505.2
extensions.
198 SF
32 SF
1 JOB
4 LF
August 27, 2014 S a l l y Swanson Architects, Inc. Project 4 14048 Survey Data -Page 17
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Tabl
lei • As -Built Description:
Knee clearance at minimums 27" high, 30" wide,
and 19" deep is not provided.
As- Built: 16" deep to leg &
lip at base.
• Proposed Solution:
Modify table as required to provide compliant knee
clearance.
Tread Surface
152 • As -Built Description:
The leading 2" of the tread does not have compliant
visual contrast of dark -0n —light or light —on —dark
from the remainder of the tread.
• As- Built: Striping has deteriorated
• Proposed Solution:
Provide contrasting color stripes at all exterior stair
treads.
Codes I Mitigation Info
PCODE N1111A
ADAAG 16.5.4.
ADA 2010 902.2
CBC 2010 1132B.1
PCODE ECO2
ADA 2010 504.4
CBC 2010 1133B.4.4
CBC 2013 1113- 504.4.1
Qty Unit
2 JOB
22 LF
low
August 27, 2014 Sally Svanson Arehile cts, Inc. Project #14048 Survey Data - Page 18
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
8 Maon Entrance
Signage
150 • As -Built Description: 1 JOB
Exterior signage at inaccessible entrances to PCODE SA01 MEN M___
provide direction to accessible entrances is missing ADAAG 4,1.2(7)(c)
or noncompliant. ADA 2010 216.6
• Proposed Solution: CBC 2010 1117B.5.8.1.2
Provide signage sufficient to guide persons to
accessible entrances.
August 27, 2014 S a l l y Swanson Architects, Inc. Project # 14048 Survey Data -Page 19
Bowers Museum Access Compliance Survey Report 1 -0-1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Codes I Mitigation Info Qty
Unit
'
9 Entrance
r
'
,S�de
o <�.
M
seignag e
157 • As -Built Description:
1
JOB
PCODE SA01
Exterior signage at inaccessible entrances to
ADAAG 4.1.2(7)(e)
provide d irection to accessible entrances is missing
smw�n'L'
ADA 2010 216.6
or noncompliant.
,
• As- Bullt: Provide ISA and Directional sign at. CBC 2010 1117B.5.8.1.2
sidewalk
• Proposed Solution:
Provide signage sufficient to guide persons to
accessible entrances.
August 27, 2014 S a l I y S ti, a n s o n A r c h i l e c i s I n c. P r o j e c t# 14048 Survey Data - Page 20
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Into City Unit
Disabled Seating
rsa • As -Built Description:
PCODE GENIE
Aisle to ttns£er seats not provided (5 °,:0 of fatal( fixed
seats, but not less than 1). ADA 2010 802.4
• As- Buttt: 3 provided CBC 2013 118-802.4
• Proposed Solution:
Provide sign or marker identifying existing seat's.
Provide additional seats when remodeling area.
• Notes:
Compliant under 1991 ADA and previous CBC
286 total
2 spaces at top
2 at bottom
3 aisle transfer seats -no isa
Door Closgr
res • As -Built Description:
Excessive force required to open door. PCODE ID03
ADAAG 4.13.11
• As- Built: 16 lbs ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5 CBC 2010 1133B.2.5
lbs rn x.). CBC 2013 1111- 404.2.9
Fixed Seating
162 AS -Built Description:
Proper amount of seating for disabled persons at
public seating is not provided (4 to 25 =1; 26 to
50 °2; 51 to 150 =4; 151 to 300 =5; 301 to 500-6;
501 to 5000 =6 +1 for each hundred; >5001 =46 +1
for each 200.
4 provided
• Proposed Solution:
Nlodi'fy seating to provide clear and level
wheelchair space 33" x 48" or 33" x 60 ", Including
companion seat, as required.
Notes:
Compliant under 1991 ADA and previous CBC
286 total
2 spaces at top
2 at bottom
PCODE GE01
ADA 2010 221.2.1
CBC 2010 1104B.3.4
CBC 2013 11B- 221.2.1
®
L�
August 27, 2014 Sall), Su,anson Arch ire cts. Inc. Project,".- 14048 Survey Data - Page 22
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Handrails
164 • As -Built Description: 24 LF
1landrail not provided at stairs or ramp, required on PCODE 8801
both sides (not required at curb ramps or adjacent to ADAAG 4,8,5 & 4.9.4
seating areas). ADA 2010 MAX
• Proposed Solution: CBC 2010 1133BA3.1 & .5,5
Provide new handrail for each side including CBC 2013 11&505.2
extensions.
Length
163 • As -Built Description:
Landing less than 60" long (CA only: bottom
lending less than 72").
• As- Built No landing at transition and turn
space: 6 -8%
• Proposed Solution:
Modify at least one ramp to have compliant
landing.
Non -Fixed Table
169 • As -Built Description:
Accessible non -fixed table or desk (top 28" to 34"
high; knee space at least 27" high x 19" deep x 30"
wide) not provided.
• As- Built: Speaker podium top: '37.25 ", no knee
space.
• Proposed Solution:
Provide table or desk with accessible dimensions
when purchasing new furniture.
NoSings
166 • M -Built Description:
Stair nosings project more than 1 -1/2" past face of
riser and /or are not beveled on underside 60" lain.
from horizontal.
• As- Built: 1.5" with no bevel
• Proposed Solution.:
Modify stair nosings.
PCODE EB07
ADAAG 4,8.4 (2)
ADA 2010 405.7.3
CBC 2010 1133B.5.4.2
CBC 2013 i1B- 405.7.3
PCODE IN0ZA
ADAAG 4323 &.4
ADA 2010 3061
CBC 2010 112213.3 & 4
CBC 2013 1111-3061 & I I
- 902.3
PCODE ECOI
ADAAG 4.93
ADA 2010 504.5
CBC 2010 1133B.4.5.2
CBC 2013 118 -5043
48 SF
1 JOB
70 LF
August 27, 2014 3 a I l y S ,v a n i on A r c h i l e e t s, In c. P r o f e c t 4 14148 Survey Data - Page 23
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 82706
• Proposed Solution:
Provide raised letter /Braille "EXIT" sign at door.
St:iirway!
165 • As -Built Description :: PCODE I102B 70 LF
The leading 2" of the tread does not have visual
contrast of dark —on —light or light —on —dark from the ADA 2090 504.4
remainder of the tread. CBC 2010 1133B_ A
• Proposed Solution: CBC 2013 1111- 504.43
Provide 2" wide contrasting color stripe I" max.
rrom nosing on top & bottom treads when altering
area.
August 27, 2014 S u l l y Swenson Architects, tea c . Project # 14048 Survey Data - Page 24
• Proposed Solution:
Provide raised letter /Braille "EXIT RAMP
UP /DOWN' sign at door.
nt • As -Built Description:
Existing sign designating permanent room or space
is noncompliant.
• Proposed Solution:
Provide compliant signage.
PCODE SA13
ADAAG 4,1.3(16)(x)
ADA 2010 216.2
CBC 2010 1117B.5
CBC 2013 1113-216.2
2 JOB
August 27, 2014 S a l l y S w a n s o n A r c h i t e c l s , 1 n c . Project it 14048 Survey Data - Page 26
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Aeces'sories
m • As -Built Description:
Toilet paper dispenser less than 15" or more than
48" above floor or not within 7" to 9" from front of
water closet.
• As -Built 0" o.c
• Proposed Solution:
Relocate or provide new toilet paper dispenser.
• Notes:
May be possible to switch with TPD dispenser
where paper location is reversed.
Alarm Signal
Jsr • As -Built Description:
Visual signal (strobe) is mounted on the ceiling,
less than 6" below the ceiling (if the intensity is
increased to penetrate smoke, a shorter dimension
may be permitted by the authority having
jurisdiction).
• Proposed Solution:
Verify compliance acrd AHJ approvals and replace,
relocate or install an extension piece if necessary
• Notes:
Verify with fire marshal
Door Closer
174 • As -Built Description:
Excessive force required to open door.
Codes I Mitigation Info
PCODE WG02
ADAAG 4.16,6
ADA 2010 604.7
CBC 2010 111511.8.4
CBC 2013 11B -604.7
PCODE 1COSDREF
ADAAG 428,3(6)
ADA 2010 702.1
PCODE ID03
ADAAG 4,13.11
• As•Bulit 12 lbs ADA 2010 404.2.9
• Proposed Solution.:
Adjust regular door closer to accessible standards (5 CBC 2010 1133B.2.5
lbs max). CBC 2013 11B404.2.9
Qty Unit
ma
August 27, 2014 S a l t y S ip a n s o n A r c h i t e c is, t n c. P r o j e c t A 14048 Survey Data - Page 26
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No, & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Door Swing
ns • As -Built Description: PCODE ID23ANT
Front approach: At pull side, door does not have
clear and level maneuvering space measuring door ADAAG Fig. 25(a)
width plus 18" x 60 ". ADA 2010 404.2.4
• As- Built: 13" to trash bin CBC 2010 II11- 26A(a)
Proposed Solution: CBC 2013 11B- 404.2.4
Provide recessed trash bin.
Protrusion Limits
178 • As -Built Description:
Protruding objects more than 4" from wall, when PCODE EG04
bottom of object more than 27" or less than 80" ADAAG 4.4.1
above finished floor. ADA 2010 307.2
• Proposed Solution: CBC 2010 1133B.8.6.1
Ensure that BCS is closed when not in use. CBC 2013 II13-307.2
Accessible u -pull or opening device also required.
Sig�nage
172 • As -Built Description.'
Plant within clear floor space of signage.
PCODE SA07BNT
ADAAG 4.30.6
• Proposed Solution:
ADA 2010 703.4.1
Relocate plant.
CBC 2010 1117B.5.7
CBC 2013 11B- 703.4.2
Stall Door
180 • As -Built Description:
Stall door to accessible compartment not self PCODE WB05B
closing. ADAAG 4.22.4
• Proposed Solution:
Adjust closer.
ADA 2010 604.8.1.2
CBC 2010 11158.3.1.4.4
CBC 2013 11B- 604.8.1.2
1 JOB
V
1 JOB
1 JOB
IIm.
August 27, 2014 S a l l y S *r a n s o n Architects, Inc. Project # 19048 Survey Data - Page 27
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. 6 Name and Proposed Solution
Codes I Mitigation Info
179 • As -Built Description:
PCODE WB05C
Stall door does not have accessible operating
hardware (U -pulls on both sides, flip -over or sliding
ADAAG 4.17.5
lock).
ADA 2010 604.8.1.2
• As -Built no upull
CBC 2010 1115B.3.1.4.5
• Proposed Solution:
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and U-
pulls on both sides.
Toilet Stall
176 • As -Built Description:
Toilet stall less than 60" wide. PCODE W1306
ADAAG 4.17,3
• As- Built: 59" wide ADA 2010 604.8.1.1
• Proposed Solution:
Modify stall to provide 60" width. CBC 2010 1115B.3.1.4.1
CBC 2013 1111- 604.8.1.1
Qty Unit
1 JOB
1 JOB
August 27, 2014 Sally Swanson Architects, Inc. Project # 14048 Survey Data - Page 28
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior
Address: 2002 N Main St, Santa Ana, CA 92706
Floor: Ground Floor
ADAAG 4,13.11
• As- Built: 9 lbs ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5 CBC 2010 1133B.2.5
IN max). CBC 2013 11B- 404.2.9
Protrusion Limits
191 • As -Built Description:
Protruding objects more than 4" from wall, when
bottom of object more than 27" or less than 80"
above finished floor.
• Proposed Solution:
Remove /relocate protruding object. Patch existing
surface.
• Notes:
Ensure that BCS is closed when not in use.
Accessible u -pull or opening device also
required.
Si na
163 • As -Built Description:
Plant within clear floor space of signage.
• Proposed Solution:
Relocate plant.
PCODE EG04
ADAAG 4.4.1
ADA 2010 307.2
CBC 2010 1133B.8.6.1
CBC 2013 11B -307.2
PCODE SA07BNT
ADAAG 4,30.6
ADA 2010 703.4.1
CBC 2010 111713.5.7
CBC 2013 I111- 703.4.2
1 JOB
1 JOB
August 27, 2014 S a l l y Swanson Architects, Inc. P r o j e c i H 14048 Survey Data - Page 29
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Stall Door
1e8 • As -Built Description:
WBOSB
Stall door to accessible compartment not self
closing.
ADAAG
ADAAG 4.22.4
ADA 2010 604.8.1.2
• Proposed Solution:
Adjust closer.
CBC 2010 1115B.3.1.4.4
CBC 2013 I113- 604.8.1.2
tae • As -Built Description:
PCODE VV'B05C
Stall door does not have accessible operating
hardware (U -pulls on both sides, flip -over or sliding
ADAAG 4.17.5
lock).
ADA 2010 604.8.1.2
• Proposed Solution:
CBC 2010 1115B.3.1.4.5
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and U-
pulls on both sides.
Toilet Stall
tes • As -Built Description:
PCODE W1106
Toilet stall less than 60" wide.
ADAAG 4,17.3
• As- Built. 59"
ADA 2010 604.8.1.1
• Proposed Solution:
Modify stall.
CBC 2010 1115B.3.1.4.1
CBC 2013 11B- 604.8.1.1
Urinal
187 • As -Built Description:
,
PCODE N U04
30" x 48" clear floor space in front of accessible
urinal not provided.
ADAAG 4.18.3
ADA 2010 605.3
• As- Built: 27.5/8"
• Proposed Solution:
CBC 2010 1115B.4.2.3
Modify mounting of privacy screen.
CBC 2013 II13-605.3
• Notes:
24" deep
1 JOB
1 JOB
1 JOB
1 JOB
August 27, 2014 S a l l y S w a n s o n A r c h i t e c i s , In c. Project # 14048 Survey Data - Page 3O
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes/ Mitigation Info
Water Closet
190 . As -Built Description: PCODE wBOS
Height of water closet seat less than 17" or more
than 19" from floor. ADAAG 4.16.3
• As- Built: 19.5" o.c.
Proposed Solution:
Modify as needed.
ADA 2010 604.4
CBC 2010 1115B.4.1.4
CBC 2013 11B -604.4
Qty unit
ism
27, 2014 Sally Swanson Architects, Inc. Project414048 Survey Data - Page 31
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior
Address: 2002 N Main St, Santa Ana, CA 92706
Floor: Ground Floor
• As- Built: 10 -13 lbs ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5 CBC 2010 1133B.2.5
Ibs max). CBC 2013 11B- 404.2.9
Protrusian Limits
195 • As -Built Description:
Protruding objects more than 4" from wall, when
bottom of object more than 27" or less than 80"
above finished floor.
• Proposed Solution.:
General; Use other displays or roping where lower
protrusions occur.
Public Counter
192 • As -Built Description:
Public Counter (Seated Service): Accessible section
not provided (knee space min. 27" high x 19" deep
x 30" wide, top 28" to 34" high, min. 36" counter
wide).
• As- Built: 43.75'
• Proposed Solution:
Retrofit existing counter to provide accessible
seating section.
Interim solution: Provide auxiliary counter or table.
PCODE EG04REF
ADAAG 4.43
ADA 2010 307.2
CBC 2010 1133B.8.6.1
CBC 2013 11B-307.2
PCODE IN03A
ADAAG 4.32.3 & 4
ADA 2010 226.1
CBC 2010 1122B.3 & 4
REF
August 27, 2014 S a l l y Swanson Architects, Inc. P r o j e c t k 14048 Survey Data - Page 32
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Proposed solution:
Provide raised letter/Braille "EXIT" sign at door.
27, 201 d S a l l y Sip a n s o n A r c h i t e c t s, t o e, Project # 14048 Survey Data - Page 33
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum part: Interior Floor: Ground Floor
Address: 2042 N Main St, Santa Ana, CA 82706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info
Dmu>:
200 • As -Built Description:
PCODE ID24C
Surface of required maneuvering clearance at door
PCODE TDI I
slopes more than 114 ".12" (10%).
ADAAG 4.13.6
latch and closer).
ADA 2010 404.2.4.4
• As- Built: 4 -6%
CBC 2013 11B- 404.2.4
• Proposed Solution:
CBC 2010 11335.2.4
Modify surface slope at door.
CBC 2013 115- 404.14
• Notes:
Corner exit NW, appears to be water damaged
Door.
Door Closer
197 • As -Built Description:
Excessive force required to open door.
PCODE ID03
ADAAG 4.13.11
• As- Built: 11 IN
• Proposed Solution:
ADA 2010 404.2.9
Adjust regular door closer to accessible standards (5
CBC 2010 1133B.2.5
Ibs max).
CBC 2013 10 -40423
Door Swing
199 • As- BuiltDescrietion:
Front approach: At push side, door does not have
PCODE ID24C
clear and level maneuvering space measuring door
ADAAG Fig. 25(a)
width x 48" (door width plus 12" if door has both,
ADA 2010 404.2.4
latch and closer).
CBC 2010 I IB- 26A(a)
• As- Built: 14" deep
CBC 2013 11B- 404.2.4
• Proposed Solutlow
Provide door operator.
202 • As -Burk Description:
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
width x 48" (door width plus 1.2" if door has both,
latch and closer),
• As -BuUk 13,5"
• Proposed Solution;
Provide door operator.
PCODE ID24C
ADAAG Fig. 25(a)
ADA 2010 404.2.4
CBC 2010 I1B- 26A(a)
CBC 2013 115. 404.2.4
Qty Unit
20 SF
1 JOB
WMe-
August 27, 2014 Sally S1a "anson Architects, Inc. Projects 14048 Survey Data - Page 34
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior
Address: 2002 N Main St, Santa Ana, CA 82706
Floor: Ground Floor
• Proposed solution:
Provide raised letter /Braille "EXIT" sign at door.
tot • As -Built Description:
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
• Proposed Solution:
Provide raised letter/Braille "EXIT" sign at door.
PCODE SAIOA
ADAAG 4.1.3(16)
ADA 2010 216.4.1
CSC 2010 1011.3
I96 • As -Built Description.:
At door leading into exit corridor: Where required
PCODE SAND
exit signs are installed, signs to provide exiting
ADAAG 4.1.3(16)
information for people with vision impairment are
ADA2010 216.4.1
not provided.
CBC 2010 1011,3
• Proposed Solution:
CBC 2013 1111- 216.4.1
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
1 JOB
1 JOB
27, 2014 S a t t y Sip a n , s o n A r c h i l e e is, I n e. P r o j e c t 4 14048 Survey Data - Page 35
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Alarm Signal
201 • As -Built Description:
At facility with a fire alarm system, visual signal PCODE IC05
(strobe) not provided at required type of common
ADAAG 4,1.3(14) & 4.28.3
use area. ADA 2010 2151 & 702.1
• Proposed Solution: CBC 2010 1114B.2.2
Provide combination visual J audible signal device
connected to existing fire alarm system.
Door Closer
204 • As -Built Description:
Excessive force required to open door. PCODE ID03
ADAAG 4.13.11
• As- Built. 11 Ibs ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5 CBS 2010 1133B.2.5
Ibs max). CBC 2013 11B- 404.2.9
Door Awing
200 • As -Built Description:
PCODE ID24A
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
ADAAG Fig. 25(a)
width x 48" (door width plus 12" if door has both,
ADA 2010 404.2.4
latch and closer).
CBC 2010 11B 26A(a)
• As- Built. 4" to bench
CBC 2013 11B- 404.14
• Proposed Solution:
Remove or relocate furniture or storage items.
1 JOB
1 JOB
1 JOB
August 27, 2014 Sall), S w a n s o n A r c h i t e c t s, Inc. P r o j e c t# 14048 Survey Data - Pape 36
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info
.slli'511age
205 • As -Built Description:
PCODE SAlOA
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
ADAAG 4.1.3(16)
information for people with vision impairment are
ADA 2010 216.4.1
not provided.
CBC 2010 1411.3
• Proposed Solution:
Provide raised letteriBrailie "EXIT" sign at door.
203 • As -Built Description:
At door leading into exit corridor: Where required PCODE SAIOD
exit signs are installed, signs to provide exiting ADAAO 4.1.3(16)
information for people with vision impairment are ADA 2010 216.4.1
not provided. CBC 2010 1011.3
• Proposed Solution: CBC 2013 1113 - 216.4.1
Provide raised letter /Braille "EXIT ROUTE," sign at
door.
• Notes:
Along once side of the room
TV closed caption decoder
Zoe • As -Built Description: PCODE 11351NT
A means for decoding caption for use by an
individual with impaired hearing is not provided at § 35.160
multimedia display.
• As- Built: No text for persons who are hearing
impaired
• Proposed Solution:
Provide closed captioning text at multimedia
display.
• Notes:
Video displays need text
City Unit
1 JOB
1 JOB
NT
August 27, 2014 S a l l y SIP a n s o n A r c h i t e c is, Inc. P r o j e n f 4 14048 Survey Data - Page 37
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior
Address: 2002 N Main St, Santa Ana, CA 92706
Floor: Ground Floor
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Alarm Signal
210 • As -Built Description:
At facility with a fire alarm system, visual signal PCODE IC05
(strobe) not provided at required type of common ADAAG 4.1.3(14) & 4.28.3
use area. ADA 2010 215.1 & 702.1
• Proposed Solution. CBC 2010 1114$12
Provide combination visual / audible signal device
connected to existing fire alarm system.
Brochure Bins
211 • As -Built Description.:
Information brochure bins mounted above
accessible height of 48 ".
As-Butt, 34 " -57"
• Proposed Solution:
Relocateirenumnt bins at accessible height.
• Notes:
provide same brochures at lower height.
Sr_gnagg
200 • As -Built Description:
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
• Proposed Solution:
Provide raised letter/Braille "EXIT' sign at door.
PCODE IN08
ADAAG 4,2.5 & 6
ADA 2010 308.2.1
CBC 2010 11185.5
PCODE 5A10A
ADAAG 4.1.3(16)
ADA 2010 216.4.1
CBC 2010 1011.3
1 JOB
I
1 JOB
August 27, 2014 S a l l y Swanson A r c h i t e c t s , Inc. P r o j e c t# 14048 Survey Data - Page 38
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Accessible Compartment
217 • As -Built Description:
The location of the stall door is not in front of the PCODE WB05D
clear space (next to the water closet), with a ADAAG 4.17.3 & Pig. 30(a)
maximum stile width of 4 ". ADA 2010 604.8.1.2
• As- Built: 7.5" CBC 2010 1115B.3.1.4.3
• Proposed Solution:
Remodel compartment.
Accessories
222 • As -Built Description:
Dispensers in sanitary facilities, such as for towels,
PCODE WG01A
soap, sanitary napkins, seat covers, etc., and waste
ADAAG 4,23.7
receptacles more than 48" (CA only: 40 ") from
ADA 2010 308.2.1
floor to highest operating slot or control.
CBC 2010 1115B.8.3
• As- Built. SD 41"
CBC 2013 1111 -603.5
• Proposed Solution:
Relocate existing restroom accessories.
214 As -Built Description.:
Toilet paper dispenser less than 15" or more than
48" above floor or not within 7" to 9" from front of
water closet.
• As- Built: 16.5" o.c.
• Proposed Solution:
Switch dispenser with TPD located on closer side.
Cross Slope
220 • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
• As- Built: 4.4 -7% by lavatories
• Proposed Solution:
Modify cross slope.
PCODE WG02
ADAAG 4.16.6
ADA 2010 604.7
CBC 2010 111511.8.4
CBC 2013 11B -604.7
PCODE EF07
ADAAG 4,3,7
ADA 2010 403.3
CBC 2010 1133B.7.1.3
CBC 2013 11 B -403.3
1 JOB
1 JOB
1 JOB
25 SF
August 27, 2014 Sally Srnanson Architects, Inc. Projeel'#14048 Survey Data - Page 39
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Codes / Mitigation Info
Door Closer
212 • As -Built Description:
PCODE ID03
Excessive force required to open door.
ADAAG 4,4,1
above finished floor.
ADAAG 4.13.11
• As- Built: 10 lbs
ADA 2010 404.2.9
• Proposed Solution:
CBC 2013 1111-307.2
Adjust regular door closer to accessible standards (5 CBC 2010 1133B.2.5
lbs max).
CBC 2013 11B- 404.2.9
Grab Bars
216 • As -Built Description:
PCODE WB07B
The rear wall grab is less than 36" min. or does not
extend from the centerline of the water closet 12"
ADAAG 4.17.6
ruin. on one side and 24" min. on the other side.
ADA 2010 604.5.2
• As- Built: L shaped grab bar extends 36" from
CBC 2010 1115B.4.1.3.2
side wall
CBC 2013 11B- 604.5.2
• Proposed Solution:
Provide or relocate accessible rear grab bar.
Lavatory
221 • As -Built Description:
Hot or sharp - surfaced water /drain pipe not insulated
or covered.
• Proposed Solution:
Insulate or cover water /drain pipe.
PCODE WD05
ADAAG 4.19.4
ADA 2010 606.5
CBC 2010 1115B.4.3.4
CBC 2013 1111-606.5
Protrusion Limits
219 • As -Built Description:
PCODE EG04
Protruding objects more than 4" from wall, when
bottom of object more than 27" or less than 80"
ADAAG 4,4,1
above finished floor.
ADA 2010 307.2
• As- Built: PTD: 9" protrusion at 42" AFF
CBC 2010 11.33B.8.6.1
• Proposed Solution.:
CBC 2013 1111-307.2
Remove/relocate protruding object. Patch existing
surface,
Qty Unit
1 JOB
1 JOB
4 JOB
Mariam 40—
2 JOB
August 27, 2014 Sally Swanson Architects, Inc Project 4 14048 Survey Data - Page 40
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
223 • As -Built Description: 2 LF
PCODE EG04A
Protruding objects more than 4" from wall, when Emom bottom of object more than 27" or less than 80" ADAAG 4.41
above (finished floor. ADA 2010 307.2
• As- Built: Counter: 29.5" CBC 2010 1133B.8,6.1
• Proposed Solution: CBC 2013 11B -307.2
Provide cane - detectable railing to mark area of low
clearance.
Semi - Ambulant Stall
224 • As -Built Description:
Semi - Ambulant stall with 36" width, parallel grab PCODE WB06A
bars, and out - swinging door not provided (one ADAAG 4.22.4
required where 6 or more exist). ADA 2010 213,33
• As- Buitt: 11 stalls CBC 2010 1115B.3.1.5
CBC 2013 1113- 604.$1
• Proposed Solution:
Provide 36" wide stall with out - swinging door and
two side grab bars. Remodel restroom as needed.
Stall .Door
tie • As -Buitt Description: PCODE WBO5C
Stall door does not have accessible operating
hardware (U -pails on both sides, flip -over or sliding ADAAG 4.175
lock). ADA 2010 604.81.2
• Proposed Solution: CBC 2010 1115B.31.4.5
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and U-
pulls on both sides.
Vestibule
21, 3 • As - Built Description:
Vestibule length in direction of travel less than PCODE IF02D
width(es) ofdoor(s) swinging into vestibule, plus ADAAG 4.13.7
48 ", ADA 2010 404.16
• As -Built, 39.5" doors in a series CBC 2010 I133B.2.4A
• Proposed Solution: CBC 2013 1113- 404.16
Install automatic, delayed - closing door operators on
existing vestibule doors.
1 JOB
1 JOB
1 JOB
2014 S a l l y Swanson A r c h i t e c t s. I n c. P r o j e c t# 14048 Survey Data - Page 41
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Water Closet
215 • As -Built Description.:
Height of water closet seat less than 17" or more
than 19" from floor.
• As- Built 19.5"
• Proposed Solution:
Provide new accessible water closet.
Codes I Mitigation Info
PCODE WBO8
ADAAG 4,16.3
ADA 2010 604.4
CBC 2010 1H511.4.1.4
CBC 2013 HB -604.4
Qty Unit
1 JOB
August 27, 2014 S a l l y S w a n s o n A r c h i t e c l s , Inc. Project # 14048 Survey Data - Page 42
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Accessories
227 • As -Built Description:
Dispensers in sanitary facilities, such as for towels,
PCODE WG01A
soap, sanitary napkins, seat covers, etc., and waste
ADAAG 4.23.7
receptacles more than 48" (CA only: 40 ") from
ADA 2010 308.2.1
floor to highest operating slot or control.
CBC 2010 111.5B.8.3
• As- Built., 46" to sensor
CBC 2013 1111-603.5
• Proposed Solution:
Relocate existing restroom accessories.
231 • As -Built Description:
Dispensers in sanitary facilities, such as for towels,
soap, sanitary napkins, seat covers, etc., and waste
receptacles more than 48" (CA only: 40 ") from
floor to highest operating slot or control.
• As- Built: SD: 41.5" AFF
• Proposed Solution:
Relocate existing restroom accessories.
232 As -Built Description:
Bottom of flat, not tilted mirror more than 40"
above floor.
• As- Built: 41" AFF
• Proposed Solution:
Relocate or provide new accessible mirror.
Cross Slone
230 • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
• As -Built 3.1% around drain
• Proposed Solution:
Modify cross slope.
PCODE WG01A
ADAAG 4.23.7
ADA 2010 308.2.1
CBC 2010 111511.8.3
CBC 2013 11B -603.5
PCODE WG03
ADAAG 4.19.6
ADA 2010 603.3
CBC 2010 111511.8.1
CBC 2013 1113-603.3
PCODE EF07
ADAAG 4.3.7
ADA 2010 403.3
CBC 2010 1133B.7.1.3
CBC 2013 1111-403.3
JOB
1 JOB
1 JOB
6 SF
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s , Inc. Project if 14048 Survey Data - Page 43
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Protrusion Limits
228 - As -Built Descnpfion: REF FCODE protruding objects more than 4" from wall, when ADAAG 4,41A �F
bottom of object more than 27" or less than 80" ADAAG 4A.I
above finished floor. ADA 2010 307.2
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Urinal
226 • As -Built Description:
36" wide clearance in front of accessible urinal not
provided when walls or partitions protect more than
24" from the front edge of 30" x 48" clear space,
• As- Bulit: 29.5" wide
24.25" deep
• Proposed Solution:
Provide 36" clear floor space in front of accessible
urinal. Remodel restroom as needed.
Codes I Mitigation Info
PCODE WE04A
ADAAG 4.183
ADA 2010 605.3
CBC 2010 1115B.4.2.3
CBC 2013 11B -605.3
Qty Unit
JOB
August 27, 2014 Satty Swanson .d re h i to c is, Inc, Project #14048 Survey Data - Page 45
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Carnetit)oorinat
236 • As -Sviit Description:
PCODE ID03 4 JOB
Doormat not securely attached to around or boor
PCODE rD05A
structure.
ADAAG 4.53
• Proposed Solution:
ADA 2010 302.2
Attach doormat to floor surface or remove doormat.
CBC 2010 1124B.3
12gor Closer
237 • As -Built Description PCODE 1D03
Excessive force required to open door.
ADAAG 4.13.11
• As -Built: 17 lbs ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5 CBC 2010 11338.2.5
lbs max). CBC 2013 I113- 404.2.9
1 JOB
+®"
291 • As -Suitt Description:
PCODE ID03 4 JOB
Excessive force required to open door.
ADAAG 4.13.11
• As- Buick: 10 lbs
ADA 2010 404.29
• Proposed Solution:
if
Adjust regular door closer to accessible standards
(5 CBC 2010 113311.2.5
lbs max).
CBC 2013 11B- 404.2.9
Protrusion Limits
238 • As -BUlif Description: 1 JOB
Protruding objects more than 4" from wall, when PCODE EG04
bottom of object more than 27" or less than 80" ADAAG 4.4.1
qa.
above finished floor. ADA 2010 307.2;
Data - Page 46
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Publie Counter
238 - As -Built Description: PCODE IN03A 1 JOB
Public Counter (Seated Service): Accessible section
not provided (knee space min. 27" high x 19" deep ADAAG 4.32.3 & 4
x 30" wide, top 2811 to 34" high, min, 36" counter ADA 2010 2261
wide). CBC 2010 1122B.3 & 4
• As -Built: 42.25`
• Proposed Solution:
Retrofit existing counter to provide accessible
seating section.
Interim solution: Provide auxiliary counter or table.
Siunnag
235 - As -Built Description:
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
• Proposed Solution:
Provide raised letter /Braille "EXIT" sign at door.
290 - As -Built Description:
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
As -Built: 7b plaza
• Proposed Solution:
Provide raised letter/Braille "EXIT" sign at door.
PCODE SAIOA
ADAAG 4.1.3(16)
ADA 2010 216.4.1
CBC 2010 10113
PCODE SA10A
ADAAG 4.1.3(16)
ADA 2010 216.4.1
CBC 2010 1011.3
MIME
1 JOB
August 27, 2014 S a 1 1 y Sv,anson A c h i re c t s, Inc. Prof cc t ii 1408 Survey Data - Page 47
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
PUb is Counter
240 - As -Bullt Description:
Pubic Counter (Seated Service): Accessible section
not provided (knee space min. 27" high x 19" deep
x 30" wide, top 28" to 34" high, min. 36" counter
wide).
As- Built: 35" top, no knee space
Proposed Solution:
Retrofit existing counter to provide accessible
seating section.
Interim solution: Provide auxiliary counter or table.
TV closed caption decoder
241 - As -Built Description:
A means for decoding caption for use by an
individual with impaired hearing is not provided at
multimedia display.
- Proposed Solution:
Provide closed captioning text at multimedia
display.
- Notes:
closed captioning
PCODE IN03A
ADAAG 4.323 & 4
ADA 2010 226.1
CSC 2010 1122B.3 & 4
PCODE IB51NT
§ 35.160
1 NT
27, 2014 S a l t y S w a n s o n A€ c h i r e c t s, Inc. P r a/ e c t d 14048 Survey Data - Page 48
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigatlon Info Qty Unit
TV closed caption decoder
243 • As -Built Description: pCODE IB51NT 1 NT
A means for decoding caption for use by an
individual with impaired hearing is not provided at § 35.160
multimedia display.
• As- Built: General title 4 requirements closed
captions
• Proposed Solution:
Provide closed captioning text at multimedia
display.
August 27, 2014 Sally Swanson Architects, Inc. Project414048 Survey Data - Page 49
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 82706
Existing Architectural Barrier
254 • As -Suitt Description:
PCODE ID06dNT
Item No. & Name and Proposed Solution
Codes I Mitigation Info
Qty Unit
ADA 2010 404.2.10
• Proposed Solution:
CBC 2010 1133B.2.6
Install kick plate at bottom 10" of door to cover
CBC 2013 11B- 404.2.10
floor latch and floor latch rods.
Corridor
249 • As -Built Description:
5 LF
PCODE IFI03
Corridor less than 36" wide.
•.�.7
ADAAC 43.3
• As -Bunk 35.5° at bottom tiles. 32" deep ADA 2010 403.5.1
• Proposed Solution:
Enlarge corridor to 36" wide; remove tiles along CBC 2010 1133B.3.t
bottom of walls in corridor and refinish. Or identify CBC 2013 11B- 403.5.1
as a qualifying historical feature.
Curb or Barrier
247 • As -Built Description. PCODE EB14
No curb (2" minimum height) or wheel guide
(centered approx. 3" above surface of ramp) at sides ADAAC 4.8.7
of ramp. ADA 2010 405.9.2
Proposed Solution. CBC 2010 1133B.5.6
Provide 2" minimum curb or wheel guide. CBC 2013 11B- 405.9.2
Rou
254 • As -Suitt Description:
PCODE ID06dNT
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface.
ADA 2010 404.2.10
• Proposed Solution:
CBC 2010 1133B.2.6
Install kick plate at bottom 10" of door to cover
CBC 2013 11B- 404.2.10
floor latch and floor latch rods.
1 JOB
2014 Sally Sis,anson Architects, Inc. ProJecig 14048 Survey Data - Page 50
Bowers Museum Access Compliance Survey Report
Facility; Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
• As- Built: Door frame: 79.25'
• Proposed Solution:
Provide new, larger door and frame with new
accessible hardware.
Door Threshold
Zee As-Built Description:
Existing threshold at door is 112" high or less but
without a beveled edge on both sides.
• As- Built: 0.5"
• Proposed Solution:
Move rope and sign back to door for viewing from
corridor.
Protrusion Limits
251 • As -Built Description:
Protruding objects more than 4" from wall, when
bottom of object more than 27" or less than 80"
above finished floor.
• As- Built: Displabox corner 16.25' deep 46"
high
• Proposed Solution:
Provide cane- detectable railing to mark area of low
clearance.
252 • As -Built Description:
Protruding objects more than 4" from wall, when
bottom of object more than 27" or less than 80"
above finished floor.
• As -Built: Display boxes project into
circulation path
• Proposed Solution:
Provide cane - detectable railing to mark area of low
clearance.
Notes:
Provide boxes under display
CBC 2010 11338.1.1.1.1
CBC 2013 11B404.2.3
PCODE ID02NT
ADAAG 4.1.6(3)(d)(ii)
ADA 2010 404.15
CBC 2010 1133B2A.1
CBC 2013 11B- 404.15
PCODE EG04A
ADAAG 4.41
ADA 2010 307.2
CBC 2010 1133B. &6.1
CBC 2013 10-307.2
PCODE EG04A
ADAAG 4.4.1
ADA 2010 307.2
CBC 2010 1133RX6.1
CBC 2013 1111-307,2
1 JOB
1 LF
4 LF
August 27, 2014 Soily S)i,anson Af-rh iJec is, Inc. ProjeciN 74018 Survey Date - Page 51
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info City Unit
Hamps
257 • As -Built Description:
Ramp needed to provide disabled access at steps or PCODE EHO1A
change of level along path of travel. ADAAB 4.1.1
ADA 2010 303.4
• As-Built: 3.75"
• Proposed Solution: CBC 2010 11271#.1
Provide directional sign to accessible exit. CBC 2013 118 -303.4
Route Sign
268 • As -Built Description -
No sign by inaccessible route directing persons to
PCODE SA20REP
an accessible route. ADAAO 35.163(b)
• As- BUllt: provide acc exit ADA 2010 216.3
• Proposed Solution: CBC 2010 11278.3
Provide directional sign.
&gnaae"
253 • As - Built Description:
At final exit door to exterior: Where required exit PCODE SAIL A
signs are installed, signs to provide exiting ADAAC 4.1.3(1.6)
information for people with vision impairment are ADA 2010 216.4.'1
not provided. CBC 2010 10113
• Proposed Solution:
Provide raised letter/Braille 'EXIT" sign at door.
256 As -Built Description:
At final exit door to exterior: Where required exit PCODE SA10A
signs are installed, signs to provide exiting ADAAC 4,1.3(16)
information for people with vision impairment are ADA 2010 216.4.1 .
not provided. CBC 2010 1011.3
• Proposed Solution:
Provide raised letter/Braille "EXIT" sign at door.
6E[i
uio[i
JOB
80111197-1
August 27, 2014 Sally Swanson Architects, Inc. Projects 14048 Survey Data - Page 32
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
• Proposed Solution: CBC 2013 118- 2164.1
Provide raised letter /Braille "EXIT ROUTE" sign at
door.
S10.pc
246 • As -Built Description.:
Slope greater than 1:12 (83 %).
• As- Built: 9% at top of ramp.
• Proposed Solution:
Modify existing ramp and handrails as necessary to
achieve compliance or identify as a qualifying
historical feature. Add caution... insure that
sufficient exiting opportunities are maintained,
• Notes:
Need bldg. official sign off
Top & Bottom Extension at Stairs
248 • As -Built Description:
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width,
sloped. plus 12` minimum horizontally beyond the
bottom nosing.
• As -Built 8" -9"
• Proposed Solution:
Extend stair handrail at top and bottom.
245 As -Built Description:
Stair handrail does not extend horizontally 12"
minimum beyond top nosing, and one tread width
sloped, plus 12" minimum horizontally beyond the
bottom nosing.
• Proposed Solution:
Extend stair handrail at top and bottom.
• Notes.
Verify exception by bldg. official, handrail at
construction joint and fire door.
PCODE EB02
ADAAG 4.8.2
ADA 2010 405.2
CBC 2010 1133B.5.3
CBC 2013 llB4051
PCODE ED06
ADAAG 4.9.4(2)
ADA 2010 50510.2; 505.10.3
CBC 2010 1133BA21
CBC 2013 11.B- 505.10.2; I I B
- 505.10.3
PCODE ED06REF
ADAAG 4.9.4(2)
ADA 2010 505.10.2; 505.10.3
CBC 2010 1133B.4:2.2
CBC2013 1113- 505.10.2; LIB
- .505.10.3
20 SF
2 JOB
REF
27,2014 Sally Swanson Architects, lnc. Project# 14048 Survey Data - Page 53
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
hour No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
TV closed caption decoder
250 - As -&uttt Description. 1 NT
PCODE IB51YF
means for decoding caption for use by an
individual with impaired hearing is not provided at 3 35.160
multimedia display.
- Proposed Solution:
Provide closed captioning text at multimedia
display.
• Notes:
Closed captions
27, 2014 S a l l y S w a n s o n A r c h i t e c t s , I n c . P r o j e c t# 14048 Survey Data - Page 54
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes/ Mitigation Info
Siunage
260 • As -Built Description: PCODE SAIOD
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting ADAAG 4.1.3(16)
information for people with vision impairment are ADA 2010 216.4.1
not provided, CBC 2010 1011.3
• Proposed Solution.: CBC 2013 1113- 216.4.1
Provide raised letter/Braille "EXIT ROUTE" sign at
door.
Qty Unit
1 JOB
August 27, 2014 Sally Swanson Architects, Inc. Project #74045 Survey Data - Page 55
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Door Swing
264 • As -Built Description:
,Latch approach: At pull side, door does not have PCODE ID27B
clear and level maneuvering space measuring door ADAAG Fig. 25(e)
width plus 24" x 48" or 54" if dour has closer. ADA 2010 404.2.4
• As -Bunt 43" at lift, no turning space at lift at CBC 2010 I1B- 26A(e)
lower landing CBC 2013 1111- 404.2.4
• Proposed Solution:
Further design analysis needed; remodel walls as
needed.
Handrails
263 • As -Built Description:
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or adjacent to
seating areas).
• Proposed Solution:
Provide new handrail for each side including
extensions.
Lifla
lei • As -Built Description.:
Wheelchair lilt not independently operated.
I JOB
PCODE ED01 4 LF
ADAAG 4.8.5 & 4.9.4
ADA 2010 504.6
CBC 2010 1133B.4.1.1 & .5.5
CBC 2013 1.111- 505.2
PCODE I002NT 1 JOB
ADAAG 4,11.3
• As -Built Deed key to operate ADA 2010 410.1 & 410.6
• Proposed Solution:
Provide automatic doors at wheelchair lift such that CBC 2010 1116BA
it is not attendant- operated and shall provide CBC 2013 11B- 41.0.1
unassisted entry and exit from the lift.
27, 2014 Sally Swanson Architects, 1 n c . P r o j e c t il 14048 Survey Data - Page 56
Sowers Museum Access Compliance Survey Report
Facility: Sowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
- Proposed Solution: CBC 2013 11B- 544.4.1
Provide 2" wide contrasting color strip 1" max.
from nosing on top & bottom treads when altering
area.
27, 2014 S a l t y S w a n s o n R r c h i t e c e s, Inc. P r o f e e t 4 14048 Survey Data - Page 57
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Into Qty Unit
Flevatol
267 • As -Bunt Description:
REF
PCODE IK04AREF
In an elevator rah with 36" wide side slide opening
doors, cab -size is not 68" min wide and/or 54" min
ADAAG Fig. 22
deep between the back wall and the elevator door,
CBC 2010 1116B.1.8
and 51" ruin deep between the back wall and the
return panel,
CBC 2013 11B- 407.4.1
As•Bullt: 51",56",59"
+ Proposed Solution:
Falls under exception for existing elevator with 18
square feet min. technical infeasibility,
2aa + As -Built Description:
PCODE IK06A 1 JOB
Elevator car lacks emergency conmumication
device that is not dependent on speaking/hearing
ADAAG 4.10.14
ability of elevator passenger.
ADA 2010 407.4.9
• As- Built: And no a -pull
CBC 2010 1116B.L8
• Proposed Solution:
CBC 2013 11B- 407.4.9
Provide elevator communication device that has
combination voice and light signal
communications.
266 • As -Built Description:
1 FLR
PCODE IK09
Call buttons in lobby 1 hall not centered 42" above
floor.
ADAAG 4.10.3
• As -Built: 39"
CBC 2010 1116B.1.10
• Proposed Solution:
Provide new or relocate elevator call buttons to 42"
above floor at exterior landing.
265 • As-Built Description:
Floor numbers not provided at all elevator entrances
with both raised characters 2" high and Braille
numbers, on each entrance jamb.
- Proposed Solution:
Provide compliant floor numbering on elevator
doorjambs,
PCODE IKII
ADAAG 4.10.5*
CBC 2010 1116B.L14
2 JOB
August 27, 2014 Salty Swanson Architects, Inc. P r o j e c I g 14048 Survey Data - Page 58
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
269 • As -Built Description: 1 JOB
Floor numbers not provided at all elevator entrances PCODE B{ll
with both raised characters 2" high and Braille ADAAG 4.10.5*
numbers, on each entrance jamb. CBC 2010 1116B.1.14
• As- Built: No star on ground floor.
• Proposed Solution:
Provide compliant floor numbering on elevator
doorjambs.
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s , Inc. P r o j e c t H 14048 Survey Data - Page 59
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
ADA 2010 505.7
• As -Built. l"
• Proposed Solution: CBC 2010 1133B.4.2.6
Provide new handrail or identify as qualifying CBC 2013 11B -505.7
historical feature and provide signage directing
disabled individuals to accessible elevator.
S4gnage
270 • As -Built Description: PCODE SA10A 1 JOB
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting ADAAG 4.1.3(16)
information for people with vision impairment are ADA 2010 216.4.1
not provided. CBC 2010 1011,3
• Proposed Solution:
Provide raised letter /Braille "EXIT" sign at door.
August 27, 2014 Sally Swanson Architects, Inc. Project # 14048 Survey Data - Page 60
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
• Proposed Solution: CSC 2413 10- 505.10.2; 1 I
Extend stair handrail at top and bottom or identify - 505.10.3
as qualifying historical feature and provide signage
directing disabled individuals to accessible elevator,
27, 2014 S a l l y S m, a n s o n A r c h i tee is, Inc, P r o j e c i# 14048 Survey Data - Page 61
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
• As- Built- 15" o.c. CBC 2010 1115B.8.4
• Proposed Solution: CBC 2013 118-604.1
Relocate or provide new toilet paper dispenser.
tso • As -Built Description:
REF
Bottom of flat, not tilted mirror more than 40"
PCODE WG03REF
above floor,
ADAAG 4,19,(, _
ADA 2010 603.3
• As- Built: Mirror above lav 54.5 "
• Proposed Solution:
CBC 2010 11158.8.1
Relocate or provide new accessible mirror.
CBC 2013 118 -603.3
- Notes:
Compliant mirror provided at side.
August 27, 2014 S a l l y .S w a n s o n A r c h i t e c l s , I n c P r o j e c i hk 11048 Survey Data - Page 62
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Lavatory.
d
278 • As -Built Description:
Wheelchair clearance under lavatory apron or
lavatory counter front edge less than 29" high.
• As -Built: 2$"
• Proposed Solution:
Provide new accessible lavatory.
277 • As -Built Description:
Hot or sharp- surfaced water /drain pipe not insulated
or covered.
• Proposed Solution:
Insulate or cover water /drain pipe.
PCODE WD03
ADAAG 4.19.2
ADA 2010 606.3
CBC 2010 1115$.4.33
PCODE WD05
ADAAG 4.19.4
ADA 2010 606.5
CBC 2010 1115B.4.14
CBC 2013 1111406.5
279 • As -Built Description:
PCODE WDO6REF
Lavatory: Accessible faucet (lever - operated, push-
type or electronically controlled) not provided.
ADAAG 4.19.5
• Proposed Solution:
ADA 2010 606.4
Provide accessible faucet at accessible lavatory.
CBC 2010 1115B.4.3
CBC 2013 IIB -606.4
signage
274 • As -Built Description:
Braille symbols: dots are not 1/10" on centers in
each cell with 2/10" space between cells.
• As -Built. Provide additional sign at door
• Proposed Solution: y
CA only - Provide new compliant signage including
Contracted Grade 2 Braille with Title 24 spacing
requirements - 1/10" on center dots with 2/10"
space between cells.
PCODE SA07C
CBC 2010 1117B.5.6
1 JOB
1 JOB
REF
1 JOB
August 27, 2014 S a t l y S w a n s o n A r c h i t e c! s, I n c, t'r o) e c t 9 14048 Survey Data - Page 63
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
275 • As -Built Description:
Entrance to toilet or bathing facility not identified
with ADAAG compliant signage.
• Proposed Solution:
Provide ADAAG compliant sign mounted 5' high
on center on nearest adjacent wall, on latch side if a
single door (located not to cause a Braille reader to
stand within the door swing).
vs • As -Built Description:
Required in CA only: identification symbol
centered 60" high on sanitary facility door not
provide([ (women: 12" o circle, men: 12" triangle,
unisex: combined symbol).
• As- Built: Not unisex sign
• Proposed Solution:
Provide properly mounted sanitary facility symbol
when altering area. If wheelchair accessible,
include International Symbol of Accessibility on
sign.
PCODE SA11A
ADAAG 4.1.3(16)(x)
ADA 2010 216.8
CBC 2013 11151=216.8
PCODE SA15
CBC 2010 1115B.6
CBC 2013 I IB- 703.7.2.6
1 JOB
1 JOB
Mall 17nor
284 • As -Built Description: 1 JOB
PCODE WB05B
Stall door to accessible compartment not self
closing. ADAAG 4.22.4
• Proposed Solution: ADA 2010 604.8.1.2
Adjust closer. CBC 2010 1115B.3.1.4.4
CBC 2013 11B- 604.8.1.2
285 • As -Built Description.'
1 JOB
PCODE VVB05C
Stall door does not have accessible operating
hardware (U -pulls on both sides, flip -over or sliding
ADAAG 4.17.5
look),
ADA 2010 604.8.1.2
• As -Built: No u-pull
CBC 2010 1115B.3.1.4.5
• Proposed Solution:
Provide new accessible locking hardware that does
not require grasping, pinching, or twisting and U-
pulls on both sides.
August 27, 2014 Salty Swanson Architects, Inc. f r o j e c t il 14048 Survey Data - Page 64
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Toilet Stall
286 • As-Built Description:
Toilet stall less than 60" wide.
• As- Built: 58" tot support
• Proposed Solution:
Modify accessible stall.
PCODE W1106
ADAAG 4.17.3
ADA 2010 604.8.1.1
CBC 2010 11158.3.1.4.1
CBC 2013 1111- 604.8.1.1
Water Closet
281 • As -Built Description.'
Height of water closet seat less than 17" or more PCODE WBOS
than 19" from floor. ADAAG 4.16.3
ADA 2010 604.4
• As -Bunt 16.5" o.c.
• Proposed Solution: CBC 2010 1115B.4.1.4
Provide new accessible water closet. CBC 2013 1111-604.4
1 JOB
I,uj
August 27, 2014 S a l l 7+ Sip a n , s o n A r e h i t e c i s, In c. P i o j e c l# 14048 Survey Data - Page 65
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Proposed Solution:
August 27, 2014 S a l l y Swanson Architects, Inc. Project # 14048 Survey Data - Page 66
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
• Proposed Solution: ADA 2010 302.2
Attach doormat to floor surface or remove doormat. CBC 2010 1124B.3
• Notes:
Throughout gift shop
Corridor
296 • As -Built Description:
Corridor, for occupant load less than 10, less than PCODE 11103A
36" wide. ADAAG 4,3.3
ADA 2010 403.5.1
• As -Built 33.5"
• Proposed Solution: CBC 2010 1133B.3.1
Remove or relocate furniture and storage items. CBC 2013 IIB- 403.5.1
Door Cwins
296 • As -Built Description:
PCODE Ill24Al2EF
Front approach: At push side, door does not have
clear and level maneuvering space measuring door
ADAAG Fig. 25(a)
width x 48" (door width plus 12" if door has both,
ADA 2010 404.2.4
latch and closer).
CBC 2010 1113- 26A(a)
• Proposed Solution:
CBC 2013 1111404.2.4
Remove or relocate furniture or storage items.
1 JOB
REF
August 27, 2014 S a l l y S w a n s o n A r c h i t e c t s , Inc. Project 8 14048 Survey Data - Page 67
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, GA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
)<'ubre Counter
293 • As -Built Description:
Public Counter (Seated Service): Accessible section
not provided (knee space min. 27" high x 19" deep
x 30" wide, top 28" to 34" high, min. 36" counter
wide).
• As- Built.' 42"
• Proposed Solution:
Retrofit existing counter to provide accessible
seating section.
Interim solution: Provide auxiliary counter or table.
Notes.
Modify
sivna e
294 • As -Built Description:
At final exit door to exterior: Where required exit
signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
• Proposed Solution:
Provide raised letter /Braille "EXIT" sign at door.
292 • As -Built Description.,
At door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting
information for people with vision impairment are
not provided.
Codes I Mitigation Info
PCODE IN03A
ADAAG 4.323 & 4
ADA 2010 226.1
CBC 2010 1122E.3 & 4
PCODE SAIOA
ADAAG 4.1,3 (16)
ADA 2010 216.41
CBC 2010 10113
PCODE SAIOD
ADAAG 41,3(16)
ADA 2010 216.4.1
CBC 2010 1011.3
• Proposed Solution: CBC 2013 11B- 216.41
Provide raised letter /Braille "EXIT ROUTE" sign at
door,
Qty Unit
1 JOB
MEN rra
7fmo -
August 27, 2014 Sally Swanson .Architects, Inc. Projector 14048 Survey Data - Page 68
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Door Closer
297 • As -Built Description:
rxeessive force required to open door.
PCODE ID03
ADAAG 4.13.11
• As- Built 10 His
ADA 2010 404.2.9
• Proposed Solution:
Adjust regular door closer to accessible standards (5
CBC 2010 1133B.2.5
lbs max).
CBC 2013 10- 404.2.9
Handrails
Sus • As -Built Descrption.:
PCODE ED01
Handrail not provided at stairs or ramp, required on
both sides (not required at curb ramps or a iacent to
ADAAG 4.85 & 4.9.4
seating areas),
ADA 2010 504.6
• Proposed Sohition:
CBC 2010 1133B.4.1.1 &.5.5
Provide new handrail for each side including
CBC 2013 1113-505.2
extensions.
Non Fixed Table
299 • As -Bunt Description:
Accessible non -fixed table or desk (top 28" to 34"
PCODE IN02A
high; knee space at least 27" high x 19" deep x 30"
ADAAG 432.3 & .4
wide) not provided.
ADA 2010 306.1
• As -Built: 26" high, 12" deep to table leg
CBC 20110 1122B.3 & 4
• Proposed Solution:
CBC 2013 1111-306.1 & 11B
Provide table or desk with accessible dimensions
-902.3
when purchasing new furniture.
• Notes:
7x2 top
15x4 tops
4 bar
1 JOB
24 LF
August 27, 2014 Salty su'anson Architects, Inc. Project #14048 Survey Data - Page 70
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
304 • As -Built Description: 3 JOB
Accessible non -fixed table or desk (top 28" to 34" PCODE IN02A t
high;, knee space at least 27" high x 19" deep x 30" ADAAG 4,32.3 &.4
rte r
wide) not provided. ADA 2010 3061 _
• As- Built: 26.75" high knee space. Also
0,25" level change at plate in clear
space.
• Proposed Solution:
Provide table or desk with accessible dimensions
when purchasing new furniture.
• Notes:
6x4tops
5x2 tons
Public Counter
zsa • As -Built Description:
Public Counter (Seated Service): Accessible section
not provided (knee space min. 27" high x 19" deep
x 30" wide, top 28" to 34" high, min, 36" counter
wide).
• As -Built, 42"
Proposed Solution:
Retrofit existing counter to provide accessible
seating section.
Interim solution: Provide auxiliary counter or table.
Sating
31s • As -Bulk Description,,
Dining area has less than required number of
wheelchair seating spaces; 5% (1 space per 20
seats), not less than one, required.
• Proposed Solution:
Provide wheelchair seating space for dining,
+ Notes:
7x2 top
15x4 tops
4 bar
sae • As -Built Description:
Dining area has less than required number of
wheelchair seating spaces; 5 %(1 space per 20
seats),, not less than one, required.
• Proposed Solution.:
Provide wheelchair seating space for dining.
• Notes:
6x4 tops
5x2 tops
CBC 2010 112211.3 & 4
CBC 2013 1111-3061 & 11 B
-902.3
PCODE IN03 A
ADAAG 4.32.3 & 4
ADA 2010 2261
CBC 2010 112211.3 & 4
PCODE FCOIREE
ADAAG 5,1
CBC 2010 1104B.5.4
CBC 2013 1111-226.1
PCODE FCOIREF
ADAAG &1
CBC 2010 110411.5.4
CBC 2013 11B -226.1
1 JOB
Ted
August 27, 2014 S a l t y S W a 12 S o n .4 r c h i t e e i s. J it C. P r qj e e 14 14048 Survey Data - Page 71
Sowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2402 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Soo • As -Built Description:
At counter or bar where food or drink is served, PCODE FC04
min. 60" of accessible counter, or accessible table ADAAG 5.2
seating within same area, not provided. ADA 2010 226.1
• As -Bunt 43.5" CBC 2010 11045.5.4
• Proposed Solution: CBC 2013 I15 -226.3
Provide accessible section (60" minimum length at
max. 34" height, with min. 27" knee space) at
counter.
I
301 - As -Built Description: PC4DE SAND
door leading into exit corridor: Where required
exit signs are installed, signs to provide exiting ADAAG 4.1,3(16)
information for people with vision impairment are ADA 2010 216.4.1
not provided. CBC 2010 1011.3
• Proposed Solution: CBC 2013 1IB- 216.4.1
Provide raised letter /Braille "'EXIT ROI.JTE" sign at
door.
Top & Bottom Extension at Stairs
s+o • As -Suit Description:
Stair handrail does not extend horizontally 12"
pCCDE ED06
minimum beyond top nosing, and one tread width
ADAAG 4,9.4(2)
sloped, plus 12" minimum horizontally beyond the
ADA2010 505.10.2; 505103
bottom nosing.
CSC 2010 1133B.4.2.2
• Proposed Solution:
CBC 2013 118- 505.10.2; 1 tB
Extend stair handrail at top and bottom.
- 505.10.3
• Notes:
middle only
ilIIMII7
HERO ]
August 27, 2014 S a l l y S it a n s o n Architects, Inc. P r o f e c i g 14048 Survey Data - Page 72
Bowers Museum Access Compliance Survey Report 1 -1 -1
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution
Codes I Mitigation Info Qty Unit
Tread Surface
ace - As -Built Description:
PCODE ECO2 110 LF
The leading 2" of the tread does not have compliant
¢
visual contrast of dark —on —light or light —on —dark
ADA 2010 504.4 ' ,
MEN=
from the remainder of the tread.
CBC 2010 1133B.4,4
- Proposed Solution: CBC 2013 11B- 504.4.1
Provide contrasting color stripes at all exterior stair
treads.
Faclitty Bowers'Museum Area Interior -.
s_ .. S _...
August 27, 2014 S a l l y S iv a n s o n A r c h i t e c t s , I n c . P r o j e c t g 14048 Survey Data - Page 73
August 27, 2014 Bowers Museum, SSA Project #14048 SALLY SWANSON
ARCMTECTS, INC.
NOTICE TO PRIVATE PROPERTY OWNER /TENANT:
YOU ARE ADVISED TO KEEP IN YOUR RECORDS ANY WRITTEN INSPECTION
REPORT AND ANY OTHER DOCUMENTATION CONCERNING YOUR PROPERTY
SITE THAT IS GIVEN TO YOU BY A CERTIFIED ACCESS SPECIALIST.
IF YOU BECOME A DEFENDANT IN A LAWSUIT THAT INCLUDES A CLAIM
CONCERNING A SITE INSPECTED BY A CERTIFIED ACCESS SPECIALIST, YOU
MAY BE ENTITLED TO A STAY (TEMPORARY STOPPAGE) OF THE CLAIM AND
AN EARLY EVALUATION CONFERENCE.
IN ORDER TO REQUEST THE STAY AND EARLY EVALUATION CONFERENCE,
YOU WILL NEED TO VERIFY THAT A CERTIFIED ACCESS SPECIALIST HAS
INSPECTED THE SITE THAT IS THE SUBJECT OF THE CLAIM. YOU WILL ALSO
BE REQUIRED TO PROVIDE THE COURT AND THE PLAINTIFF WITH THE COPY
OF A WRITTEN INSPECTION REPORT BY THE CERTIFIED ACCESS SPECIALIST,
AS SET FORTH IN CIVIL CODE SECTION 55.54. THE APPLICATION FORM AND
INFORMATION ON HOW TO REQUEST A STAYAND EARLY EVALUATION
CONFERENCE MAY BE OBTAINED AT http:// www.courtinfo.ca.gov /selfhelp /.
YOU ARE ENTITLED TO REQUEST, FROM A CERTIFIED ACCESS SPECIALIST
WHO HAS CONDUCTED AN INSPECTION OF YOUR PROPERTY, A WRITTEN
INSPECTION REPORT AND OTHER DOCUMENTATION AS SET FORTH IN CIVIL
CODE SECTION 55.53. YOU ARE ALSO ENTITLED TO REQUEST THE ISSUANCE
OF A DISABILITY ACCESS INSPECTION CERTIFICATE, WHICH YOU MAY POST
ON YOUR PROPERTY.
August 27, 2014 SSA Project #14048 Page 28 of 28
Bowers Museum Access Compliance Survey Report
Facility: Bowers Museum Part: Interior Floor: Ground Floor
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
Change in Direction
307 • As -Built Description:
Landing at change of direction not 60" minimum by PCODE EB08
72" minimum in the direction of downward travel ADAAG 4,8,4(3)
from the upper ramp run. ADA 2010 405.7.4
• As- Built: BL: 56" CBC 2010 1133B.5.4
• Proposed Solution: CBC 2013 11B- 405.7.4
Modify landing at change of direction to 60" x 72 ".
Cross Slope
306 • As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
• As- Built., 2.5 -3.0%
• Proposed Solution:
Modify cross slope.
• Notes:
locate
308 As -Built Description:
Cross slope more than 1 ":48" (2.083 %).
• As- Built: 2.5 -4.6%
• Proposed Solution:
Modify cross slope.
Donr
302 • As -Built Description.:
At push side of door on accessible route, bottom
10" does not have a smooth, uninterrupted surface.
• Proposed Solution.:
Install kick plate at bottom 10" of door to cover
floor latch and floor latch rods.
PCODE EF07
ADAAG 4.3.7
ADA 2010 403.3
CBC 2010 1133B.7.1.3
CBC 2013 11B -403.3
PCODE EF07
ADAAG 4.3.7
ADA 2010 403.3
CBC 2010 1133B.7.1.3
CBC 2013 I111-403.3
PCODE ID06ANT
ADA 2010 404.2.10
CBC 2010 1133B.2.6
CBC 2013 1111- 404.2.10
24 SF
20 SF
120 SF
3 JOB
August 27, 2014 Sally Swanson Architects, Inc. Project 4 14098 Survey Data - Page 69
Bowers Museum Access Compliance Survey Report 1 -0 -1
Facility: Bowers Museum Part: Exterior Floor: On -site
Address: 2002 N Main St, Santa Ana, CA 92706
Existing Architectural Barrier
Item No. & Name and Proposed Solution Codes I Mitigation Info Qty Unit
81=
158 • As -Built Description: PCODE EBOSA
Level (1:48 %) max. landing for ramp not provided.
ADAAG 4.8,4
• As- Built: 2.4% at top landing ADA 2010 405.7.1
• Proposed Solution:
Rebuild to provide landings for each ramp run with CBC 2010 1133B.5.4.1
slopes no greater than (1:48 %) CBC 2013 11B- 405.7.1
Ton and Bottom Extension at
160 • As -Built Description:
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.
• As- Built: 10"
• Proposed Solution:
Provide ramp handrail extension.
yes • As -Built Description:
Ramp handrail does not extend horizontally 12"
past top and / or bottom of ramp.
• As -Built Bottom not parallel to landing. ends
short.
• Proposed Solution:
Provide ramp handrail extension.
PCODE ED05
ADAAG 4.8.5(2)
ADA 2010 505.10.1
CBC 2010 1133B.4.2.2 &
CBC 2013 10- 505.10.1
PCODE ED05REF
ADAAG 4,8,5(2)
ADA 2010 505.10.1
CBC 2010 1133B.4.2.2 &
CBC 2013 11B- 505.10.1
35 SF
4 JOB
REF
August 27, 2014 Sally S w a n s o n A r c h i t e c i s , Inc. P r o j e c 1 8 14048 Survey Data - Page 21