HomeMy WebLinkAbout31D - CUP - 1666 N MAIN STREQUEST FOR
COUNCIL ACTION
CITY COUNCIL MEETING DATE:
JUNE 7, 2016
TITLE:
VARIANCE NO. 2016 -04 FOR A REDUCTION
IN REQUIRED PARKING FOR THE SANTA
ANA ARTS COLLECTIVE ADAPTIVE REUSE
PROJECT LOCATED AT 1666 NORTH MAIN
STREET - MICHELLE COULTER, APPLICANT
(STRATEGIC PLAN NOS. 3,2,5; 5, 3,4)
CITY MAN ER
RECOMMENDED ACTION
CLERK OF COUNCIL USE ONLY:
❑ As Recommended
❑ As Amended
❑ Ordinance on 1" Reading
El Ordinance on 2nd Reading
❑ Implementing Resolution
❑ Set Pubilc Hearing For,__
CONTINUED TO
FILE NUMBER
Receive and file the staff report approving Variance No. 2016 -04 as conditioned.
PLANNING COMMISSION ACTION
At its regular meeting on May 9, 2016 by a vote of 4:0 (Alderete, McLoughlin, Verino absent), the
Planning Commission adopted a resolution approving Variance No. 2016 -04 as conditioned to
allow the reduction in required parking for the Santa Ana Arts Collective adaptive reuse project at
1666 North Main Street located in the Midtown Specific Plan (SP -3) zoning district. The Planning
Commission made no changes to the recommendation outlined in the attached staff report
(Exhibit A).
DISCUSSION
Meta Housing Corporation is proposing an adaptive reuse project to convert an existing five -story
office building to residential, commercial, and community uses. The applicant is also proposing to
construct three additional structures and common open space on the site. Two of these structures
would contain two stories and the third would be single -story. All three structures would contain
residential units. A total of 58 affordable residential units and 113 parking spaces would be provided
on site, as well as on -site amenities, open space, galleries, and community rooms. Full -sized plans
are available for public viewing in the Clerk of the Council Office.
The project, pursuant to Section 41 -1903 of the Santa Ana Municipal Code, is exempt from the
Housing Opportunity Ordinance. No Housing Inclusionary Plan is required.
31 D -1
VA No. 2016 -04 — Reduction in Parking for Santa Ana Arts Collective Adaptive Reuse Project —
1666 North Main Street
June 7, 2016
Page 2
STRATEGIC PLAN ALIGNMENT
Approval of this item supports the City's efforts to meet Goal #3 - Economic Development,
Objectives #2 (create new opportunities for business /job growth and encourage private
development through new General Plan and Zoning Ordinance policies), Objective #5 (leverage
private investment that results in tax base expansion and job creation citywide); Goal #5 -
Community Health, Livability, Engagement & Sustainability, Objectives #3 (facilitate diverse
housing opportunities and support efforts to preserve and improve the livability of Santa Ana
neighborhoods), and Objective #4 (support neighborhood vitality and livability).
FISCAL IMPACT
There is no fiscal impact associated with this action.
tl Hassan Haghani, AI
Executive Director
Planning & Building Agency
AP:rb
ap \reports \Staff Reports For CCNA16 -4 Meta Housing Adaptive Reuse, cc
Exhibit: A. Planning Commission Staff Report
31 D -2
REQUEST FOR
Planning Commission Action
TITLE:
PUBLIC HEARING — FILED BY MICHELLE COULTER
FOR VARIANCE NO. 2016 -04 FOR A REDUCTION IN
REQUIRED PARKING FOR THE SANTA ANA ARTS
COLLECTIVE ADAPTIVE REUSE PROJECT LOCATED
AT 1666 NORTH MAIN STREET {STRATEGIC PLAN
NOS. 3,2; 3, 5; 5, 3; 5,4)
Prepared by Ali Pezeshkpour
PLANNING COMMISSION SECRETARY
APPROVED
• As Recommended
• As Amended
• Set Public Hearing For
DENIED
• Applicant's Request
• Staff Recommendation
CONTINUED TO
.._._._._._ Exe ZvelDirector Planning Manager
RECOMMENDED ACTIONS
Adopt a resolution approving Variance No. 2016 -04 as conditioned.
Request of Applicant
Michelle Coulter with Meta Housing Corporation, representing Santa Ana Arts Collective, LP, is
requesting approval of a variance from the provisions of the Adaptive Reuse Ordinance contained
in Santa Ana Municipal Code (SAMC) Section 41 -1652 to allow a reduction in the number of
required parking spaces for a 58 -unit affordable residential housing and commercial adaptive reuse
project. Projects requesting relief from development standards such as parking require approval of
a variance pursuant to SAMC Section 41 -638.
Proeect Location and Site Description
Meta Housing is proposing to renovate and convert an existing five -story office building into
residential, community, and commercial space within the existing structure and in three new
detached structures proposed on the project site. A total of 58 residential units are proposed at the
project. All units are intended to provide affordable housing to artists and their families. The
project site contains 1.11 acres and is located on the south side of Seventeenth Street between
Main and Sycamore streets. In addition to the five -story office building, the site also contains a
gated entry, landscape planters, and 145 parking spaces located in a surface lot (27 stalls) and
underground parking structure (118 stalls). Surrounding land uses include commercial uses in all
directions (Exhibits 1, 2 and 3).
The General Plan land use designation for the site is General Commercial (GC), which allows for
commercial and office uses. General Commercial districts are primarily located on commercial
corridors and major arterial roadways in the City. They provide accessible commercial
EXHIBIT A
31 D -3
Variance No. 2016 -04
May 9, 2016
Page 2
development along the City's arterials as well as provide support facilities and services, including
offices, restaurants and various other services. Pursuant to the provisions of the Adaptive Reuse
Ordinance (SAMC Section 41- 1652), adaptive reuse projects are allowed to convert non-
residential uses to residential, making the project consistent with this General Plan land use
designation.
The site is located within the boundaries of the Midtown Specific Plan (SP -3) area. The SP -3
area allows for commercial and service uses. However, pursuant to the provisions of the
Adaptive Reuse Ordinance (SAMC Section 41- 1651), residential adaptive reuse projects must be
located within one of the Project Incentive Areas, which includes the Midtown Specific Plan area.
Project Description
Meta Housing Corporation is proposing an adaptive reuse project to convert an existing five -story
office building to residential, commercial, and community uses. The applicant is also proposing to
construct three additional structures and common open space on the site. Two of these structures
would contain two stories, and the third would be single -story. All three structures would contain
residential units,
Residential Component
A variety of uses are proposed for the existing five -story building. The ground floor will contain
residential units, live /work studios facing Seventeenth Street, an art garden and sculpture at the
southwest corner of Main and Seventeenth streets, a lobby and gallery to showcase the various
works produced by the artists living at the site, a music and performing arts rooms, and a maker's
space for producing and showcasing art. The ground floor will also contain a community kitchen,
leasing office, and a laundry room. The upper levels of the five -story building will contain residential
units and a laundry room on each level. A total of 48 residential units are proposed in the structure
(Exhibits 4 and 5).
In addition to rehabilitating and renovating the five -story structure, the applicant also proposes to
construct three separate residential structures. Two of these structures would contain two -story
residential townhomes, and one structure, which will face Seventeenth Street, will contain three
single -story residential units with high ceilings to complement the commercial nature of Seventeenth
Street. A total of 10 units are proposed among the three new structures.
The project proposes a variety of floor plans to accommodate the unique needs of the targeted
community living in the project. Studio units will range from 526 to 722 square feet and will make up
31 percent of the unit types in the project. One - bedroom units will range from 636 to 642 square
feet, constituting 14 percent of the project. Two- bedroom units will range from 871 to 965 square
feet and will make up 22 percent of the project, and the three- bedroom units will range
31 D -4
Variance No, 2016 -04
May 9, 2016
Page 3
from 938 to 1,300 square feet and will make up 33 percent of the project. All ground -floor residential
units facing the streets will contain front patios or recessed entries, Moreover, all interior units
whose front entries face common corridors have been designed with recessed entries that enhance
the sense of home and allow for welcome mats, planters, and other embellishments to individualize
each entry.
Parking, Architecture and Landscaping
The project site currently contains 145 parking spaces. The majority of these spaces, 118, are
contained in a subterranean garage, while 27 are contained in a surface parking area. To
accommodate construction of the three new residential buildings and the project's primary open -
space courtyard, all but one of these surface stalls will be removed. To enhance security for the
project, the gated entry will be relocated to the foot of the ramp inside the subterranean garage,
ensuring that only residents and registered visitors access the garage. The subterranean parking
spaces inside the garage will be reconfigured to allow trash enclosures and a bicycle storage facility
inside. Existing elevators and stairwells are proposed to remain, however, one stairwell will be
reconfigured to allow egress from the garage directly to the interior of the project site. All resident
parking inside the garage will be assigned through an on -site parking management plan, and
visitors will need to register with on -site management to park inside visitor stalls.
The streets surrounding the project site will be Improved as part of the project. Although parking is
not allowed on Main, Seventeenth, or Sycamore streets, street reconstruction on Sycamore Street
that is required for the project will result in new bulb -outs for pedestrian safety and additional street
parking options where red striping currently exists. Moreover, sidewalks, curbs, paving, safety
enhancements, and tree wells will be reconstructed or installed as part of the project.
A modern style of architecture is proposed for the project. Enhancements to the existing five -story
Mid - Century building will complement the new construction. These include new paint on spandrel
panels, refinishing exposed concrete, public art sculptures near the main entry, and new ground -
floor finishes and installed art. The three new structures will contain a variety of building materials,
including wood pattern fiber cement panels, clear anodized aluminum plaster reveals, and fiber
cement wall panels (Exhibit 6).
Finally, landscape improvements will result in reconstruction of the planters adjacent to the project
site's main entry, as well as construction of a new tot lot in the interior courtyard, new landscape
planters, and community garden boxes. Landscaping will be added to the entire project perimeter,
and existing street trees will be replaced in accordance with City standards. Trees and landscaping
will also be added to create a buffer between the project and the commercial building to the south of
the project site (Exhibit 7).
31 D -5
Variance No. 2016 -04
May 9, 2016
Page 4
Protect Backaround
The five -story office building and subterranean garage were constructed in 1969 and contained
offices for a variety of banking companies. Since then, a variety of tenant improvements have taken
place inside the building to accommodate various professional offices, including law firms, banks,
and professional services. Because the site was constructed prior to July 1, 1974, and because it is
located in one of the Adaptive Reuse Ordinance's Project Incentive Areas, the site is eligible for an
adaptive reuse project. In 1968, Variance No. 68 -103 was approved to allow construction of the
project and the subterranean garage with a majority of the parking stalls in a tandem stall
configuration. Although the City's parking ordinance did not allow tandem parking at the time, the
application was recommended for approval because the amount of parking proposed exceeded the
minimum requirements for office developments and because an on -site parking attendant would
manage parking during normal business hours. As part of the adaptive reuse project, the applicant
does not propose any substantial modification to the tandem stall configuration that has existed
since 1969; moreover, the applicant will utilize an on -site parking management system to assign
resident and visitor parking stalls, which will be located in a secured area.
Meta Housing Corporation was established in '1993 and is an industry leader in constructing and
managing affordable housing communities throughout California. Meta has developed and
managed over 6,000 residential units in communities in Northern and Southern California, with the
majority located in Los Angeles. Meta projects in Orange County include communities in Yorba
Linda and Lake Forest. The Santa Ana Arts Collective would be Meta's third Orange County
project.
In November 2015, Meta Housing Corporation was awarded $4,635,000 for the Santa Ana Arts
Collective through a competitive Request for Proposal process. Funding sources include $500,000
in Community Development Block Grant (CDBG) funds, $1,875,000 in the City's Inclusionary
Housing Funds, and $2,260,000 in HOME Investment Partnership Program funds. In March 2016,
the applicant submitted plans to develop an artist -and family- oriented affordable housing community
to the City for review by the Development Review Committee. Analysis of the project revealed
substantial conformance to the City's Adaptive Reuse Ordinance, except for the proposed on -site
parking, which is described in further detail in the Project Analysis section. Following comments by
the City, the applicant revised the plans to enhance the street improvements required for the project,
the overall architecture, site design, and onsite amenities.
Pro!Gct Analysis
Variance requests are governed by Section 41 -638 of the SAMC. Variance requests may be
granted when it can be shown that there exists a special circumstance related to the property, such
as size, shape, topography, location or surroundings; that the granting of the variance is necessary
for the preservation and enjoyment of substantial property rights; that the granting of the variance
will not be detrimental to the public or surrounding property; and that the granting of the variance will
not adversely affect the General Plan.
31 D -6
Variance No, 2016 -04
May 9, 2016
Page 5
The applicant is requesting approval of a variance to allow a reduction in parking required by the
Adaptive Reuse Ordinance. Pursuant to SAMC Section 41- 1652(c)(2), new parking spaces are not
required for converted uses within existing buildings. However, new residential units require two
additional spaces per unit. The entire site currently contains 145 parking spaces. Pursuant to the
SAMC, 20 additional parking stalls would be required for the 10 units in the new buildings, bringing
the total required parking to 165. The project proposes 113 parking spaces, resulting in a deficiency
of 52 spaces, or a 32 percent reduction in required parking. Approval of a variance application is
required due to the Adaptive Reuse Ordinance's parking requirements for new residential units,
regardless of the existing parking spaces provided when the project was originally constructed.
To analyze whether the existing parking on the site could accommodate the proposed adaptive
reuse and new construction, and therefore substantiate the variance request, the applicant hired the
traffic engineering firm Park Green to provide a parking analysis for the project, The study also
surveyed other projects developed by Meta Housing and the actual parking demand for their
projects in an effort to provide a realistic parking demand for the project in Santa Ana. Based on
its analysis, the parking study indicates that the 113 parking stalls proposed for the project are
sufficient to meet the needs of the community and visitors to the site (Exhibit 8).
At a rate of 1.95 parking spaces per unit or 1.05 parking spaces per bedroom, the Santa Ana Arts
Collective project will provide approximately 30 percent more than the average parking ratio per
residential unit at other Meta Housing residential developments. Typical parking ratios for Meta
Housing's specialized; family - oriented affordable housing communities range from as low as one
space per unit to 2.26. The Meta Housing projects that provide over two parking spaces per unit
feature primarily two and three - bedroom units, The Santa Ana project, with just fewer than two
parking spaces per unit, will provide approximately half of its floor plans as two- or three - bedroom
units. The parking analysis further supports the 1.95 parking space ratio per unit due to the
project's proximity to multiple transit lines and its location on two significant commercial corridors
(Seventeenth and Main streets), thus reducing the average individual vehicle trips per household.
To supplement the parking analysis, Meta also provided a survey of 18 of their affordable
housing projects in other jurisdictions. The survey includes weekday morning, weekday evening,
and weekend morning parking inventories (Exhibit 9). The survey indicates that for some of the
projects with the lowest parking space ratios per bedroom, the parking vacancy rates were the
highest, All projects surveyed had available parking during all the survey times, with vacancy
rates ranging from four to 73 percent on Monday evenings, 12 to 68 percent on Tuesday
mornings, and three to 68 percent on Saturday mornings. The Grove at Sunset Court in the city
of Brentwood, a recently - completed Meta Housing project that is in a suburban, greenfield setting
near two transit lines, provides 2.02 parking spaces per unit and 1.01 spaces per bedroom unit.
This project experienced parking vacancies ranging between 17 and 32 percent. The Santa Ana
Arts Collective will provide the highest parking space ratio per bedroom out of any Meta Housing
project and is located on a site that is served by four transit lines and is completely surrounded by
commercial land uses. Based on the parking analysis prepared by Park Green and the Meta
Housing parking vacancy site surveys, staff recommends approval of the variance application.
31 D -7
Variance No. 2016 -04
May 9, 2016
Page 6
City staff also reviewed the San Diego Affordable Housing Parking Study, an analysis completed
in 2011 by CDM Smith for the City of San Diego. The Study served to determine links between
affordable housing variables such as income levels, transit accessibility, and local land use
context, in order to develop a consistent regulatory framework for parking requirements. A
survey completed as part of the Study revealed that recently- completed family- oriented
affordable housing projects in San Diego were built with excess parking, and that a 1.1 parking
space ratio per unit was sufficient to meet the needs of the residential communities. At 1.95
parking spaces per unit, the Meta Housing project in Santa Ana significantly exceeds this ratio.
Public Notification
On April 21, 2016 the applicant held a community meeting in accordance with the provisions of the
Sunshine Ordinance (Ordinance No. NS- 2838). Approximately 15 local residents and property
owners attended the meeting, as well as the project developers, architects and City staff. Attendees
asked questions on topics such as minimum requirements to qualify as a resident at the project,
parking, traffic and ingress /egress, and open space. Following the meeting, the applicant provided
an affidavit to City staff containing meeting information, minutes, and a statement that the meeting
was held in compliance with the Sunshine Ordinance's requirements.
The project is not located within the boundaries of an established Neighborhood Association.
However, staff contacted the presidents of the nearby Santa Ana Triangle and French Court
neighborhood associations to ensure that they were notified of this project and to identify any
areas of concern. Neither president identified any concerns with the proposed project. The
project site was also posted with a notice advertising this public hearing, a notice was published
in the Orange County Reporter, and mailed notices were sent to all property owners and tenants
within 500 feet of the project site. At the time of this printing, no correspondence, either written or
electronic, had been received from any members of the public.
0<
In accordance with the California Environmental Quality Act, the proposed project is categorically
exempt from CEQA review per Section 15332. The Class 32 exemption applies to projects
characterized as infill development meeting the following conditions:
• The project is consistent with the applicable general plan designation and all applicable general
plan policies as well as with applicable zoning designation and regulations.
• The proposed development occurs within city limits on a project site of no more than five acres
substantially surrounded by urban uses.
31 D -8
Variance No. 2016 -04
May 9, 2016
Page 7
* The project site has no value as habitat for endangered, rare or threatened species.
• Approval of the project would not result in any significant effects relating to traffic, noise, air
quality, or water quality.
* The site can be adequately served by all required utilities and public services.
In analyzing the variance application, staff finds that the project qualifies for the Class 32 exemption.
The project is consistent with the applicable general plan designation and all applicable general plan
policies as well as with applicable zoning designation and regulations through the Adaptive Reuse
Ordinance. As proposed, the project will meet the intent and standards of the General Plan Land
Use Element and SP -3 zoning district standards. Moreover, the proposed development will take
place within city limits and is on a project site that is less than five acres in size and is surrounded by
urban uses. The project site has no value as habitat for endangered, rare, or threatened species
and is not identified in the General Plan as having such value. Approval of the project will not result
in any significant effects relating to traffic, noise, air quality, or water quality. The City's Planning
Division and Public Works Agency have reviewed the proposed project and have determined that
the amount of traffic, noise, air quality, and water quality impacts are below thresholds that would
warrant further analyses. Finally, the site is already served by all required utilities and public
services as it is located within a heavily - urbanized area near the intersection of Main and
Seventeenth streets. Based on this analysis, a Notice of Exemption for Environmental Review
No. 2016 -17 will be filed for this project.
Strata lc Plan Alignment
Approval of this item supports the City's efforts to meet Goal No. 3 Economic development,
Objectives No. 2 (create new opportunities for business /job growth and encourage private
development through new General Plan and Zoning Ordinance policies) and No. 5 (leverage
private investment that results in tax base expansion and job creation citywide) of the Santa Ana
Strategic Plan. Moreover, approval of this item supports Goal No. 5 Community Health,
Livability, Engagement & Sustainability, Objectives No. 3 (facilitate diverse housing opportunities
and support efforts to preserve and improve the livability of Santa Ana neighborhoods) and No. 4
(support neighborhood vitality and livability).
31 D -9
Variance No. 2016 -04
May 9, 2016
Page 8
Based on the analysis provided within this report, staff recommends that the Planning Commission
approve Variance No. 2016 -04 as conditioned.
Ali Pezeshkpour, AICP
Senior Planner
AP:jm
aplreporWSlaff Reports for PC \VA16 -4 Mete Housing Adaptive Reuse.pc
Attachments:
Exhibit 1 — Vicinity Map
Exhibit 2 — Location Map
Exhibit 3 — Site Photo
Exhibit 4 — Site Plan
Exhibit 6 — Floor Plans
Exhibit 6 — Elevations
Exhibit 7 — Landscape Plan
Exhibit 8 — Parking Analysis
Exhibit 9 — Affordable Housing Project, Survey
31 D -10
R MID
i +on Ks R1 R7 qz G
J` nun
MO y RI
RI RT Pi R7 R Al p -
F c P 58 wo n' Mai„ R7 s PY
R2
Acl Eci cs
R3- q3- R3- p
xPn non xoN � �io�I
nou ' xmi R}
xon
Rz Pz xa r P
Rz Pa na P
ax=
k P aP
a P P `lJ
P EE
ONC(fXIN L'R
P
WON villik 114111
@@ Mi
$V 9P SP M11 PA P3 Q 3 M7
z
M2
M0
5P -9 SPA ~' 1
�' SPP ryo Nj 113
$P -3 M
R2 ?y
�i
R2 sn.a SD- SP -3 5P -R � M,4 nn
75 pa
M
jp� 5P -1 sr
'3 1 ail 'T �',IVVV/�s�
5P-3 S , — nP D
srs �
Al
GENExALAGRWLWIALT
CR
OOMMSUALFE. UDMAL
RI
$NGLEFAMILYRADIEWAL
-R
WNWMODIHCAMON
cc
G0VMMRITCFMR7
R2
TM FAMILYSSOItlCE
GSM
WMMEFCALSOUTH MAIN
M1
UrHTINDUSHAL
R1
MUCHRLDE48TYMUL11R.E
OI
COMMUNITYCOMMMAL
M2
HFAVYINDURTRAL
FAMILYFE3MCE
01-MO
ODMM. C0MMf3GAUMUMJM DISRRCT
MO
MIUAR(OFWRONS
RA
EUSUFF+NARaRIMRJTS
C2
GENIPALCOMMUUAL
O
CIAN9gCE
FE
RMOINTIALEfATE-
Cl
CRNTPALEUSNFM
P
PIDFE9ONAL
so
MMCOEVROWWT'
0-A
CRNTPAL8U$NMARI5TMLLAGE
PCO
RANNEDOOMMUNITYOEVR.OFMW
R'
s`WFICpWI
01
R.ANNO)940PiNG0RNTER
Pv
RANNOOFESORPIALOET3.ORMENT
CA
ARTMALCOMMECIAL
aN VA 2016 -04 k
META HOUSING ADAPTIVE REUSE JCP
1666 NORTH MAIN STREET _ =SOO FEEr
1"= 1000hFET
P L A N ___N I N G A N D B U I L D I N G A G E N C Y
EXHIBIT 1
TUD41
COMME F
C I A L
r
d
u
w
J
d
U
O
v
VA 2016 -04
META HOUSING ADAPTIVE REUSE
1666 NORTH MAIN STREET
P L A N N I N G A N D B U I L D I N G A G E N C Y
LAND USE MAP
EXHIBIT 2
31 D -12
VA 2016 -04
META HOUSING ADAPTIVE REUSE
1666 NORTH MAIN STREET
SITE PHOTO
jjbjJ3 3
ekmrf
AA
- - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - -
M444
M6d,
- - - - - - - - - - - - - - -- - - - - - - - - - - - - - - - - - - - - - - - - - -
M444
(1) Q n, n r) r-.1) rn
EXHIBIT 6
311D.215
D
I
D
-0
gs
-T
flf-
-4 - - - - - - - - - - -
I
io-i
11- 1
j-4—
---
---------
"I -----------------
Iii
7
-------
-
---
A.1
EXHIBIT 6
311D.215
D
I
D
-0
gs
uol�aead�op 8u�snory esay
'a�i49l3NOl•�hi^�� '-•-��
31 [' o%a
I
m
a ra
s} ?1
al
wm..Mnn.. ,.xm,n.w, s,opaos —fop 9ulsnnq xrogaooq��
119e�Ip IN b1+1
4
I
�re
..,_ ,M�`� 1 ,.., � z....6. �
31 `0'=i°
1 -T _(.7
�i
I I I
I I;
I I
I !
I I
1
I
I I*
as I
a I
I
I I'
�r
I
I
ry r rr
1
r r
a r r
r r rn— r—r —rTrrr r—{
�
rdiL91611 �rtk
II
PdLA,dl:
..,_ ,M�`� 1 ,.., � z....6. �
31 `0'=i°
1 -T _(.7
�i
I I I
I I;
I I
I !
I I
1
I
I I*
as I
a I
I
I I'
S-Pen H =W
G) Q (M G
V V & ts) le)
p e4of4
I
b0
L-
ED
--- — ----- ...
. . ...... . ...
-------------
V V & ts) le)
p e4of4
I
b0
L-
ED
�-. W-1, -__ qj..W.p
III
, -Rlmw
ct
rim
-I
31
I I
I M_
2 of 5
E Mj
qi
� uoHxaoJa —ap Baj /Sln /o�H Wept'
N
�a
66
ss2
kW
s
z
r!
J
4
$
1
H U
h M1
3 r{► p 13 of 5
F1
4
s
E
x
R
_ ,opxanmup auk :nnw waw
- e
9
316-22 of 5
P
b i b ti
a
d
3.
a
=I
a
ti a
s
v
- e
9
316-22 of 5
P
b i b ti
a
d
11 AAA 13MT]
\�\ }
'Wriligm.
V4�lH�gdiP� BV�SngH ea9W
e3ais3- ,,, :r,, �.' 4__ __- ___EXHIBIT 7
parking design group
April 20, 2016
Mr. David Sabunas, AIA, ASLA
Senior Associate, Project Design Director
studioneleven
at Perkowitz + Ruth Architects
111 West Ocean Blvd, 20th floor
Long Beach, California 50802
Cark reen t0
Pork Doerr, LLC is a wholly -awned subsidlafy of Parkin {f Design Group, !1P
Regarding,
Meta Housing - Santa Ana Arts Collective Parking Analysis, Santa Ana, CA
Dear Mr. Sabunas:
The following is our final submittal for the parking analysis for the Meta Housing — Santa Ana Arts Collective
in Santa Ana, CA. Upon your review, comments and updates, we will provide the final analysis for your
distribution.
Project Description
The scope of our work efforts for this analysis was three -fold:
Work Effort #1. Re- design parking layout to provide maximized efficiency and parking capacity (see
attached drawing).
Work Effort #2. Provide an analysis of an operations plan supporting the application for a variance to
code and provide input to support the variance application.
Work Effort #3. Develop a Traffic Intensity Factor (TIF) Analysis (a.k.a. Traffic Queue Study) to
determine level of service (LOS) for the traffic flow at the parking garage.
Parking Layout Recommendations
The attached drawing (Exhibit "A ") reflects our recommended parking layout for the subterranean parking
level. This parking layout results in a parking capacity of 112 spaces, including five (5) accessible parking
Spaces and one (1) van accessible parking space, in addition, the proposed design of this project also shows
one (1) parking space located at the Grade Level of the site. This space will be designated as a van
accessible parking space as per the Americans with Disabilities Act (ADA) and the California Building Code
(CBC) Title 24. The total proposed project parking capacity will then be 113 spaces.
parking design group _a___- _ __ - — ------ _..
b 6 E. Padfic Coast Highway SWlo 200 tong Beach, CA 90804 56P. 98a 7105
300468
META Housing - Santa Ann Arts Collective Parking Analysis
April 20, 2016
Page 2
Application for Parking Variance to Code
The Meta Housing - Santa Ana Arts Collective Project is classified as an adaptive re -use type. The previous
use of the building was an office building. The existing parking for this office building was provided on an at-
grade parking lot with a parking capacity of approximately of 27 spaces and a one -level subterranean
parking garage with a parking capacity of approximately 118 spaces, fora total of approximately 145 parking
spaces.
The existing parking layout in the subterranean parking garage does not conform to code as it relates to the
Americans with Disabilities Act (ADA) and the California Building Code (CBC) Title 24 for accessible
parking requirements. As provided, there are no accessible parking spaces.
As currently designed and proposed, this project has a parking requirement based on the City of Santa Ana
Adaptive Re -use Code of 165 spaces. As previously mentioned, the parking provided in the proposed
subterranean parking garage is 112 spaces, plus one (1) parking space (van accessible) at the Grade Level
for a total provided parking capacity of 113 spaces. This results in a deficit of 52 spaces (165 required — 113
provided = 52 deficit),
Therefore, a variance for the parking component of this proposed project will be required to meet the City's
parking requirements. Some of the factors for consideration in supporting a variance to the Santa Ana
Adaptive Re -use Code:
The proposed Meta Housing —Santa Ana Arts Collective Project is an adaptive re -use project.
META Housing's historical data on parking provided at other facilities indicates that the Santa Ana
Arts Collective project will be parked at approximately 28% (1.95 — 1.53 = .45/1.53 = 27.5 %) over
the parking ratio per residential unit average of what is found at other Meta Housing Family
Developments (see Table A below).
Consideration to proximity to mass transit stops and mass transit usage. The Orange County Transit
Authority (OCTA) operates several transit lines adjacent to the community along N. Main Street and
W. Seventeenth Street. These transit lines are the 60, 83, 53, and 757 lines with multiple transit
stops within one block of the building. These transit lines provide easy access to many parts of the
City, as well as the ARTIC Transit Center in Anaheim which is a hub for OCTA and Amtrak. The
31 D -26
META Housing- Santa Ana Arts Collective parking Analysis
April 20, 2016
Page 3
ARTIC (Anaheim Regional Transportation intermodal Center is Southern California's newest transit
hub, providing stress -free commuting and access to many destinations throughout the Los Angeles
area, It is located next to Angel Stadium of Anaheim and Honda Center with the Disneyland Resort
just a few miles away.
Parking supply at Meta's 18 Family Developments.
Meta currently operates 18 Family (as defined by TCAC) developments throughout California, in
municipalities as far north as Brentwood and as far south as Lake Forest. All of these developments
serve households earning between 30 -- 60% Area Median Income, and none serve Special Needs or
formerly Homeless households, Because the distribution of unit sizes varies widely, the parking
analysis below compares parking spaces to bedrooms (P:BR) as opposed to parking spaces per unit.
(In other words, while 3- bedroom units make up 30% of some developments, there are as high as
80% 3- bedrooms in other developments).
To provide a basis of comparison to Santa Ana Arts Collective (SAAC), it is useful to note the
Following.
- SAAC's proposed parking to bedroom ratio (P:BR) is 1.03.
- SAAC's Walkscore is 86, meaning most errands can be accomplished on foot.
SAAC's Transit Score is 49, meaning that there a few nearby public transportation options.
Observations from Meta's 18 operating family projects:
- At 1.03, the P:BR ratio proposed at SAAC is higher than any Meta family project. Meta's
P:BR ratio ranges from 0.44 to 1.01, and averages 0,76.
- The Grove at Sunset, located in Brentwood, CA is Meta's highest P:BR site. However, The
Grove Isn't comparable to SAAC because its Walkscore is far lower at 53, meaning
"somewhat walkable." Plus Brentwood has no transit options.
- With a P:BR ratio of 0,93, Long Beach & Burnett is the 2 "d heaviest parked of Meta's family
developments. This may be comparable to SAAC, in that the Walkscore is 85.
Geographically, the closest two projects to SAAC are in Yorba Linda and Lake Forest, both in
Orange County.
o Yorba Linda has an 81 Walkscore, similar to Santa Ana's 86 Walkscore, The P: BR
ratio is 0.78, well below SAAC's proposed P:BR ratio of 1,01
31 D -27
META Housing — Santa Ana Arts Collective Parking Analysis
April 20, 2016
Page 4
o Lake Forest has a far lower Walkscore of 37, meaning that most errands require a
vehicle. It's P:BR ratio is 0.85, again lower than SAAC's proposed P:BR.
- The project whose unit distribution most closely resembles SAAC's is located in Torrance.
This location is a "Walkers Paradise" with a 91 Walkscore, with some transit at a Transit
Score of 38. In other words, the site is more walkable but less transit friendly than SAAC. It's
P:BR ratio is 0.83, or 20% less than SAAC.
Local commerce located within easy walking or two blocks of the site:
Grocery stores and food markets
Medical clinics, medical offices, dental offices, optometrist offices
Convenience stores
Restaurants (Norms Restaurant, Subway, Baskin Robins, Yoshinoya Beef Bowl, pizza,
tacos /burritos shops)
Tax, law and insurance offices
- Beauty salon and barber shop
- Dry cleaners
Bank of America
- Discount store
- Museums (Kidseum, Bowers Museum two blocks away)
0 Consideration of the San Diego Affordable Housing Parking Study' ( "SD Parking Study ") (see
Exhibit "B ", Executive Summary) was researched by Wilbur Smith Associates (now CDM Smith) in
association with AECOM, for the City of San Diego. Its purpose was to "determine the links
between affordable housing variables (income levels, household age, transit accessibility, land use
context, and housing type) for use in developing a corresponding regulatory framework for parking
requirements."
While all the findings are included in the attached report, of particular relevance to our project is "In
all of the projects studied, the amount of peak overnight parking used was less than the amount
supplied."
In the SD Parking Study, a parking model was developed based upon the findings in the statistical
analysis. It provided the basis for empirically -based rates for four types of affordable housing:
Family, Living Unit /SRO, Senior Housing, and Studio - 1 Bedroom. For family projects, total parking
projected to be needed (adjusted for vacancy) is 1.1 parking spaces per unit overall. This would
result In a projected parking demand of 64 spaces at Santa Ana Arts Collective. The report also
I San IJidyo AHmdaEla Housing P.Am, Study - December 11, conducted and submitted by Wilbur Smith Associates in asdoniabon with AECOM, Mmhael F. Kodam" Planning Consultants, Richard
Willson, PhD and the National Data and Sunning Sannoea
31 D -28
META Housing — Santa Ana Arts Collective Parking Anelysis
April 20, 2016
Page 5
provides unit size parking demand by project type. As seen below, the highest demand for parking at
the Santa Ana Arts Collective is projected to be 86.85 spaces.
Here's the math behind the results above. All demand is from the Family Housing Parking Model
Unit Size
High/ Med/ Low
Parking Ratio
Units at SAAC
High
Medium
Low
1 BR
1.0/0.6/0,33
26
26
15.6
8.58
2 BR
1.3/1.1/0.5
15
19.5
16.5
7.5
3 BR
1.75/1.4/0.75
17
29.75
23.8
12.75
Visitor
0.15
58 total
83
8.7
8.7
Staff
1 0.05
1 58 total
2.9
1 2.9
2:9
Total Parking
Recommended
86,85
67.5
40.43
• Consideration should be given to not only low levels of resident automobile ownership, but also to
current trends in auto ownership in millennials and population in general.
6 Shared -use and bicycle use considerations. The proposed project will have a storage room for as
many as 28 bicycles.
Current Industry trends, as written on by Dr. Donald Shoup in The High Cost of Free Parking',
reflect a sustainable approach by making parking minimum requirements the parking maximum
requirements or a "Freeze" on parking allowances. These trends have been, or are beginning to be,
adopted by major metropolitan areas worldwide such as, but not limited to:
Boston, MA
- Cambridge, MA
St. Augustine, FL
- Los Angeles, CA (for adaptive re -use projects)
- Columbus, OH
Washington, DC
Zurich, Switzerland
Berlin, Germany
London, England
2 The High Cost o[ Fns Perking - Plnnnera press, Amencnn PIe In g Aasocinuon. 2005. Dr, Doonid SM.P, Rpnrtment al Urban Plon.il On.,Wty ar 0.11 Vnia, tar Aeyeles
31 D -29
META Housing —Santa Are Arts Collective Parking Analysis
April 20, 2016
Page 6
Table A
Meta Housing Family Developments Parking Analysis
Mere n .93 0A2
6anin Ane Ada Calhny 1080 N. Blain 6l�In Ana 02]01 F4mlly 50 2U 15 i] 113 a .95 8
Based on this comprehensive range of considerations, it seems prudent that a variance is justifiable for this
proposed adaptive re -use facility.
31 D -30
pralahl
Adtleess
City
21p
8r44us
pvrolm
IT
c.nmu.ro
Type
Units
19R
2aft
3HR
9paonsurvip4r
aadrarm
A,amsnnd Cn 1ml
938EAtla a Id.
Lan An alas
9a01
O
05
2U ID
F.'rb
00
15
1 35
1 50
154
1.93
-- 0:88'
Union tFaml A arimants
424Union
Los Angeles
fl 01)
0
2 9
$11212009
Famll
21
0
9
12
24
11
Yffillill 4t
3
PlcdGremar M111110m1 A la.
3201 West Pin * BIVId
loo An hies
90010
O
2004
1012007
Family
1
19
10
33
93
.31
+ °: -;0:90
-0
Cllnlhn FamllVApatlmanip
2114 On On Sucel
Las An ales
90026
2006
IV1212009
Family
aA
24
0
12
36
1.00
'!'090
5
C anlaF ml A Wools
204 LUCas AVenu
Los oaths
90029
—Pp—
Op
2006
0 005
Family
21
2
12
]
21
100
8
- yr d Terra a Femil A Is
1345 Emaraltl Odve
Lan An atva
90020
0
2 D4
1200)
Famll
85
8
38
39
193
1 02
]
filch*. Famli A nrimena
90N. Sf M1ol 6lrovt
Las An Alva
00031
Oa
2008
]2x12008
Famil
2S
0
12
J)
1.U0.[
8
Ve onl Fn1r18 A1eri enla
40t5VOnnet
en
9003]
O
2010
51201
Fami
9
8
22
10
4B
1.00
.5.
mn Ville aPerkA ed ,en1e
4601 E52 diva
Vnmml
90053
O
512 812 0 15
Fami
45
B
2
4
]8
1.98
`0.80
10
Cobrilla Faml AadmOnla
164U Cabdilo Ave
Torrmmh
00501
O
4312915
land
A
22
8
4
a8
150
0.83
11
Pedtic Avenue Adv C0lnn
5 1 aj0h AVn
Son adry
90 1
1213012014
Pam
49
10
23
i9
9]
90
- 084:
12
La oannh96arnn1l
V on Beth Sivd.
Lm, 8enc1
tl002
O
212010
Fnm
40
0
0
20
104
2.20
"a r2v37, n,
1
5 m oVllo h
] 35 N. Wibdr AVenu*
Rvaad.
01335
O
2009
ag u
Famil
]3
20
6
25
118
1.58
0:]T'
14
Oerrdo Fam11 A ar1manls
129 EI Oarvd*AV *hue
6 mnr
81342
O
2008
9l 1200
Femi
90
1a
4
IS
T9
13
" 0:85
15
Tables Tartvice A ed a la
9 4] Va s eivtl
Penote a CII
01402
O
2011
9120 3
Pvmi
50
JB
0
19
95
1.18
' "094
19
Thv Arry al Baker ench
2 OtlO RannOO Pnd<wa 9,
La eel
8283
O
A211010
Fnmi
189
5)
]5
5T
321
i.)0
- - [,085:
1
nr o Inch Pelm Famll Ala.
198-02 Yarde Linde 9lvtl
Yotbs Linde
02986
O
120tl]
Fe 1
44
0
0
30
91
220
1199.
10
.0 SOl C04r
55 nvvnwnatl AVa
ran d
84fii3
O
t'
a
44
Is
19
In
1UU
2.02
Mere n .93 0A2
6anin Ane Ada Calhny 1080 N. Blain 6l�In Ana 02]01 F4mlly 50 2U 15 i] 113 a .95 8
Based on this comprehensive range of considerations, it seems prudent that a variance is justifiable for this
proposed adaptive re -use facility.
31 D -30
MLTA Housing — Santa Ana Arts Collective Parking Analysis
April 20, 2016
Page 7
Traffic Intensity Factor (T1F) Analysis (aka Traffic (Queue Study)
The following is a review of the traffic intensity of the proposed Meta Housing — Santa Ana Arts Collective
Parking Facility.
When designing a parking facility it is critical to consider the external traffic flow, internal traffic flow and the
ingress /egress control plazas. This will result in a parking facility that will provide the highest level of user
comfort and convenience. It is also critical to understand the TIF for the parking facility. This calculation
takes into consideration assumed peak -hour traffic volumes, along with ease of traffic flow which depends on
the type of parking operation It is, e.g, free parking, paid parking, short -term (shopping patrons /visitors) and
long -term parking (employees), etc.
The proper design of the vehicular ingress /egress control plazas ensures desirable traffic flow. Consideration
of the user - groups is important. For Instance, some facilities may not require gate - controlled access, whereby
traffic has a free -flow style. Other facilities may require gate controls to realize revenue potential or to
control user -type parking areas, e.g, residents, long- term/employee parking, nested parking areas, short-
term /visitor parking, etc.
Project Description
The Meta Housing — Santa Ana Arts Collective will be an affordable housing /adaptive re -use project that will
have one (1) van accessible space located at the Grade Level and 112 parking spaces in a one- level,
subterranean parking garage. Of these, ten (10) spaces will be reserved for visitors and three (3) spaces will
be reserved for employees. These thirteen (13) spaces will be located outside of the gated controls (see
Exhibit "A ") and will have free -flow vehicular ingress /egress. The residential parking will be located in a
reserved parking area that will have vehicular gate controls for ingress and egress.
The proposed vehicular access will be via one entrance gate and one exit gate. The gates will be traditional
sliding gates as are normally used in multi - family residential properties. These vehicular gates are proposed
to be controlled by typical garage door openers. The opening of these gates typically takes approximately five
to ten seconds. This is normally how gate - controlled entrances and exits function. High speed gates for this
type of project are cost prohibitive.
Specifically, this review will include confirmation that the vehicular access lanes will be adequate in regards to
the parking control service rate for the parking components of this affordable housing residential project. This
31 D -31
META Mousing —Santa Ana Arts Collective Parking Analysis
April 20, 201 G
Page B
analysis will focus on arrival rates since a primary concern of most destinations is allowing visitors /residents
efficient access to the site efficiently.
Visitor /Employee Parking
As it relates to the ten visitor parking spaces and three employee spaces, industry standards indicate that the
average vehicular headway for a free -flow system without vehicular control gates is estimated to be
approximately 3.6 seconds per vehicle, if there is easy direct approach and no sharp /difficult turns into /out of
the property. This equates to approximately 1,000 vehicles per hour per lane (60 seconds x 60 minutes =
3,600 - 3.6 seconds = 1,000 vehicles per hour).
Conservatively, an assumption of 80% peak -hour traffic factor is used when considering the maximum traffic
volume rate. Normally the traffic volume will be at a much lesser rate throughout the majority of the day, but
80% is being used as a conservative estimate for the purpose of this report. At 80% the maximum design rate
is estimated to be, approximately 800 vehicles per hour.
Residential Parking
As it relates to the 99 residential parking spaces located in the subterranean level, industry standards indicate
that the average vehicular headway for a gate - controlled system is estimated to be approximately 8.9 seconds
per vehicle, if there is easy direct approach and no sharp /difficult turns into /out of the property. This equates
to approximately 1,000 vehicles per hour- per lane (60 seconds x 60 minutes = 3,600 _ 8.9 seconds = 405
vehicles per hour).
Conservatively, an assumption of 80 °% peak -hour traffic factor is used when considering the maximum traffic
volume rate for this type of affordable housing residential property. Normally the traffic volume for this type
of housing will be at a much lesser rate throughout the majority of the day, but 80% is being used as a
conservative estimate for the purpose of this report. At 80% the maximum design rate is estimated to be
approximately 324 vehicles per hour.
Parking Control Service Rates
The following are the anticipated parking control service rates for the visitor, employee and residential parking
at the Meta Housing — Santa Ana Arts Collective:
31 D -32
META Housing -Santa Ana Arts Collective Parking Analysis
April 20, 201 G
Page 9
Visitor /Employee Parking Calculations — 13 Spaces
At 80 %, the maximum visitor /employee traffic volume is 10.4 vehicles (.8 x 13). There is one entrance to the
parking garage. Therefore, if all of the visitor and employee vehicles arrived at the same time, there would be
a volume rate of 10.4 vehicles per lane. The TIF is then calculated as:
10.4 vehicles per lane _ 800 est. peak -hour traffic rate = .013 TIF
Exhibit "C" — Reservoir Needs vs. Traffic Intensity, indicates that a .013 TIF falls well within a LOS of "A" on a
scale of "A" to "E ", LOS "A" being the best. LOS "A" is the range from approximately 0 to ,55.
Residential Parking Calculations — 99 Sgaces
At 80 %, the maximum overall traffic volume is 79.2 vehicles (.8 x 99). There Is one entrance to the parking
garage. Therefore, there is a volume rate of 79.2 vehicles per lane. The TIF is then calculated as:
79.2 vehicles per lane - 324 est. peak hour traffic rate = .244 TIF
Exhibit "C' — Reservoir Needs vs. Traffic Intensity, indicates that a .244 TIF falls within a Level of Service
(LOS) of "A" on a scale of "A" to "E ", LOS "A" being the best.
EXHIBIT "C"
RESERVOIR NELGS Vf.a. 'RAFFI.^. INTENSITY
;
L -�-
° -_— ` d _
ff
Trtiffl IpAnnrllY G� kb i?Yrl...tl Raltsi. H °y. wur'vki, R,ala?
t
31 D -33
MCTA Housing — Santa Ana Arts Collective Parking Analysis
April 20, 2016
Page 10
Conclusion
The estimated Traffic Intensity Factor for both calculations (visitors /employees and residential) falls well
within Level of Service "A ". Therefore, the proposed parking facility entrance /exit configurations will be more
than adequate for the anticipated traffic volumes to the Meta Housing — Santa Ana Arts Collective Parking
Garage.
For both calculations, as currently designed, the total queuing distance is approximately 175' to 180'.
Typically, queuing is the distance from the property line at the vehicular entrance(s) to control gate(s). In the
case of the Meta Housing — Santa Ana Arts Collective Project it is the distance from the driveway at the
property line at N. Sycamore Street to the first visitor parking spaces and vehicular control gates. At an
assumed 18' vehicular length, this equates to a vehicular queuing of approximately ten (10) vehicles. With
this, it is reasonable to believe that the proposed design is adequate to serve the needs of the site.
Parking Design Group has used what would be considered to be conservative assumptions for these
estimated TIF calculations. It would be reasonable to expect even better results, an improved LOS "A" if
more liberal assumptions were applied, e.g. 80% peak -hour traffic flow rate. The calculations used in this
analysis are based on industry- accepted standards and are typically used for determining similar TIF analyses
for various types of parking facilities.
Thank you again for the opportunity to provide our services on this important project. Please contact us with
any clarifications needed or questions you may have.
Sincerely,
rA.
David L. Vogel, Design Partner
Attachments
� �•. a' 11/0 i114 • .._:. -
,, is il•_
Y� •i xvcL21
a rt 31r� f
p:\ users\ dnvid \Ja¢Idop \pdq \Prnjecta \arutlip I I I \soots ons arts colony\ anntunnaartecolon y porHinganeiprrkingdasiqnqrpup04 201 B.duc
31 D -34
0 ,
M_
are° `°
parking design group W, Para Green (1G isawnaily- aancdCmnsd2ryalParkirttl evyn Gronp LLP
Santa Ana Arts Colony
Santa Ana, CA
NORTH
Proposed Parking Layout
Scale: 9" = 40'(1 I "x 5.5" Sheet)
Perking Capacity..
99 Resident Qncluding S Access.)
10 Visitor (Including 1 Van Access.)
9 Employee
112 Total
31 D -35
Submitted to
City ot Sari niepo
Submitted by
MbLY Srfl&� tilt—
In association with
AD— OM
Michac-! R, Kedonl'l Nalf1iing
(ow,okjwt�,
Ric hard Mison PhD
Nsil icwai Wla and 5ui veymp,
'Iervires
WilburSmIth
A 5 S 0 L I A T C 5
San Diego Affordable Housing
Parking Study
December 2011
31 D-36
Executive Summary
Purpose & Goals
The purpose of the San Diego Affordable Housing Parking Study was to determine the links between
affordable housing variables (income levels, household age, transit accessibility, land use context, and
housing type) for use in developing a corresponding regulatory framework for parking requirements.
Organization & Process
The study was broken down into the following discrete related tasks addressed by a collaborative team
process.
• Stakeholder and Public Outreach • Best Practices and Case Studies
• Review of City Policies and Current Research • Applied Parking Model
• Data Collection Methodology & GIS Database a Policy Recommendations
• Statistical Analysis & Parking Demand Tool
Stakeholder & Public Outreach
A detailed public outreach strategy was developed including the use Project Working Group (PWG) that was
used to solicit advice and feedback on policy issues. Other key elements of the outreach included project
fact sheets, a public workshop and stakeholder focus groups.
Review of City Policies, Current Research & Best Practices
The city's parking code and policies, recent industry research pertaining to affordable housing and parking
requirement adjustments, and best practices from similar communities were reviewed, revealing the
following:
1) There is a substantial gap between demand for affordable housing and the number of units that can
realistically be built in San Diego.
2) Affordable housing developments in San Diego are subject to a complex set of parking requirements
and potential modifications. But, it is not clear the current code provides modifications in a manner
consistent with a project's likely parking demand.
3) in addition to increasing the price of housing by driving up construction costs, parking requirements
also impact site design; reducing the land available for residences.
4) While the costs created by excessive parking requirements affect all types of homeowners and
renters, their impact on lower income households is particularly disproportionate because low
income households consistently own fewer vehicles than their higher income counterparts.
Data Collection Methodology & CFS Database
GlS Database of Affordable Housing Sites: The consultant team developed a master list of affordable
housing project sites based on city records.' The database contained 265 unique developments that were
coded with a series of "project" and "neighborhood" variables that captured key characteristics about each
development's qualities and surroundings. The sites were further reduced to eliminate all sites with less
than 80% restricted units leaving 138 affordable sites available for data collection.
Site Selection Methodology: The 1.38 sites established a variable profile target for a future a data collection
sample. The goal for data collection was to select a minimum of 30 sites to survey that met the existing
I . The list maintained by SDHC, RDA, CCDC and SEDC included both rental and ownership developments and contains project types
ranging from senior housing, to transitional homes, to inclusionary units within larger market rate developments,
ES -1 i
31 D -37
i
project characteristic mix (existing population of affordable housing sites) and 20 of those sites to collect on-
site parking occupancy data. The final selection was made by the city staff. Sources of data for the study are
summarized as follows:
• Household surveys — Household characteristics (e.g. size, income, # vehicles, parking behavior)
• Management surveys - Project characteristics, details and operations
• Field observations — Parking counts, land uses and parking restrictions,
A total of 27 80 household surveys were distributed to 34 selected project sites with an overall 40% return.
One management survey was returned for every project site. Field observations were conducted at 21 sites
that maintained the original sample mix and also had a survey response rate of 20 percent or more.
Occupancy data was collected at each site both on and off- street between the hours of 12AM and 4AM to
measure peak resident parking demand. Property manager feedback was most helpful in the review of
tandem parking and parking assignment practices.
fla.rking I7a eland Analysis,
The statistical arralysisof the survey and field data provided a step -by -step examination of the primary
determinant of resident lal parking demand- household vehicle availability— considering both the level
household vehilde avaihbility and factors that affect it. The findings are summarized as l'oilows:;
1) Parking demand for affordable projects is about one half of typical rental units in San Diego; almost
half the units surveyed had no vehicle:'
2) Parking demand varies with type of affordable housing (i.e., Family Housing versus SRO); higher
3)
the amount of peak overnight parking used was less than the amount
Parking Model: A parking model was developed based upon the findings in the statistical analysis. It
provided empirically-based rates for four types of affordable housing: Family, Living Unit /SRO, Senior
Housing, and Studio - ]. Bedroom. The model's predictions were compared with existing requirements and
supply patterns, to understand the alignment of those requirements with actual demand levels. The main
conclusion from these tests was that current requirements do not require significantly more parking than
the household survey -based parking model would suggest. Overnight parking occupancy in projects (where
data was available) was less than the current requirements and the model prediction, but overnight parking
counts did not account for visitor parking, overnight trips by residents, and some other aspects of demand.
ecomYXI en CIO fl rids
it was recommended that the parking modal be used to create a, fool; up table of new affordable housing
parking requirements. The parking regNiren, ents are determined based on type of afforefable housing and its
context in, terms of transit avaffabilfty and, walkability. The parking, requirements also include provisions for
visitor and staff parking and expected vacancy. The recornmen&if parsing reclufrements are summarized in
the following table,
ES -2 (
31 D -38
r�
V ,
4
W
`o
w
c �
rl C
C
b M
L> b
� ti r
ri F
F-1 N
N N
N N
N
° N
N
y U
,
�1p.1 O
F �
�y
N M
°
3 °
yr
`j. t
O t
t,J
t N
N O
o c
ci d
d c
ci c
ci
a L
d
CY. a
ti u
.r
z
W ^
^
M
Lq N
N
d O
O
� M
M O
O
W; m W b
b M `
`�. c
c5y i14-1
.•.��s r
raa z
z n
nrj m
mac' M
M10
v n
n o
o 0
0 0
0
4 v
o w
w v
vl u
u°i I
In
0 0
0 0
0
a
d
It
7 I
It t
tI
It
C 7
It a
� a
m �
r E
v c
m E
E `c
3 y
W
It
E 6
3 $
0
0 0
4 N
W
It
E
0
a �
ry ti m
a v
�fi y
w E
N 4
O v t m
� N W
n F
� a
U C y C
d
C V N C p
C Q m ecL W C
N
O v L i vU- N
y � i Itl C ta,1 N
tl
It J O V ry
w1O v
9
v V p P W
5 a `o >
n E
4> E
a v a o 3
W uti m N CN 11 L N
c m
a
'''ou ire > vl a
I�
a
.- �rvmww.o r. M
w 1
T W
31 D -40
Santa Ana Arts Collective
Meta Family Developments Parking Analysis
Project Address City gip Total 1OR 26R
units
7
Sichel Family Apartments 1805 N. $!chat Street Los Angeles 90031 37 25 0
8
Vermont Family Apartments
4915 Vermont
Los Angeles
90037
49
8
22
10
Cabrillo Family Apartments
1640 Cabrillo Ave
Torrance
90501
44
22
8
15
Tobias Terrace Apartments
9247 Van Nuys Blvd
Panorama City
91402
56
38
0
3
Pico/Gramercy Multifamily Apia.
3201 West Pico Blvd
Los Angeles
90019
71
19
19
14
El Dorado Family Apartments
12129 El Dorado Avenue
S Imar
91342
60
18
24
9
Vemon Village Park Apartments
4601 E 52nd Drive
Vernon
90058
45
9
22
13
Sherman Village
7135 N, Wilbur Avenue
Reseda
91335
73
20
28
18
The Grove at Sunset Court
55 Havenwood Ave
Brentwood
94613
54
18
18
12
Lon Beach & Burnett
2355 Long Beach Blvd.
ach
90802
46
0
26
6
Emerald Terrace Family Apts.
1345 Emer ald Drive
eles
90026
85
a
38
2
Union Point Famil A artments
420 Union Drive
ales
90017
21
0
9
16
The Arro a at Baker Ranch
26000 Ranoho Parkway South
est
92630
1$9
57
75
5
Coronita Famil Apartments
204 Lucas Avenue
nLong
ales
90026
21
2
12
11
Pacific Avenue Arts Colon
303 South Pacific Ave
ro
90731
49
10
23
17
Yorba Linda Palm Famil A ts.
18542 Yorba Linda Blvd.
nda
92886
44
0
8
Clinton Famil A artments
2114 Clinton Street
eles
90026
36
24
0
1
Adams and Central
939 E. Adams Blvd.
eles
90011
80
15
35
,. 535
177
167
Santa Ana Arts Colony 1666 N. Main St Santa Ana 92701 58 26 15
31 D -41
Property list M:1Current ProjectsWeta Housing 1666 N MainWeta Family Developments Parking
31 D -42
L5 5.9.16
RESOLUTION NO. 2016 -XX
A RESOLUTION OF THE PLANNING COMMISSION OF
THE CITY OF SANTA ANA APPROVING VARIANCE NO.
2016 -04 AS CONDITIONED TO ALLOW A REDUCTION IN
REQUIRED PARKING FOR THE PROPERTY LOCATED
AT 1666 NORTH MAIN STREET
BE IT RESOLVED BY THE PLANNING COMMISSION OF THE CITY OF
SANTA ANA AS FOLLOWS:
Section 1. The Planning Commission of the City of Santa Ana hereby finds,
determines and declares as follows:
A. Applicant is requesting approval of Variance No. 2016 -04 to allow a
reduction in required parking pursuant to SAMC Section 41 -1652 for a
mixed -use adaptive reuse project proposed at the property located at 1666
North Main Street.
B. On May 9, 2016, the Planning Commission held a duly noticed public
hearing on Variance No, 2016 -04.
C. The Planning Commission of the City of Santa Ana determines that the
following findings, which must be established in order to approve this
Variance application pursuant to Santa Ana Municipal Code (SAMC)
Section 41 -1652, have been established for Variance No. 2016 -04 for the
proposed reduction in required parking:
That because of special circumstances applicable to the subject
property, including size, shape, topography, location or surroundings,
that the strict application of the zoning ordinance is found to deprive
the subject property of privileges not otherwise at variance with the
intent and purpose of the provisions of this Chapter.
The project site has a special circumstance related to its
location and surroundings. The proposed use will be located
on a project site that is built out and is completely surrounded
by streets or other development. Due to its location, there is
no feasible option for providing the additional parking that the
Adaptive Reuse Ordinance requires for the new construction
proposed as part of the adaptive reuse project. Based on a
parking analysis and comparison with other affordable housing
projects in the region, staff analysis shows that the number of
on -site parking spaces will be sufficient to meet the needs of
the project. Moreover, the parking analysis prepared for the
A Resolution No. 2016 -xx
31 D -43 Page 1 of 7
project and the comparable San Diego Affordable Housing
Parking Study indicate that a surplus of parking spaces will be
provided for the project. As a result, the parking variance will
allow the applicant the ability to use the property in a manner
that is consistent with the surrounding land uses without
detrimentally affecting the area.
2. That the granting of a variance is necessary for the preservation and
enjoyment of one or more substantial property rights.
The granting of the variance is necessary for the preservation
and enjoyment of substantial property rights. The granting of
the parking variance will preserve the property owner's ability
to convert the building to a use that will contribute to the
community by providing family - oriented affordable housing
and ground -floor commercial uses. The site that is the subject
of this application has remained underutilized in recent years.
The granting of the variance will allow a new type of use, a
mixed -use, arts- and family- oriented affordable housing
project, to establish itself in Santa Ana.
3. That the granting of a variance will not be materially detrimental to
the public welfare or injurious to surrounding property.
The granting of the variance will not be detrimental to the
public or surrounding properties. As demonstrated in the
parking analysis for the project, the site will have sufficient
parking to accommodate the various uses proposed as part of
the adaptive reuse project. Therefore, the reduction in parking
will not be detrimental to the surrounding community as it will
not result in parking impacts affecting adjacent commercial or
residential neighborhoods. Further, the granting of the
variance will allow the property owner to redevelop the site,
contributing to the vitality and success of the Main Street
corridor, which has emerged as an arts and educational
corridor in recent years. Finally, conditions have been placed
to ensure that the site be in compliance with all other
development standards applicable to the property.
4. That the granting of a variance will not adversely affect the General
Plan of the City.
The project will not adversely affect the General Plan as the
proposed adaptive reuse project use is consistent with Goals
1 and 2 of the Land Use Element of the General Plan.
These goals encourage uses such as the Santa Ana Arts
Collective that promote a balance of land uses to address
Resolution No. 2016 -xx
31 D -44 Page 2 of 7
basic community needs such as housing and commercial
uses and which enhance the City's economic and fiscal
viability. In addition, the project is consistent with Policy 2.2 of
the Land Use Element, which supports commercial uses that
accommodate the City's needs for goods and services,
including arts production spaces, galleries, and community
centers. Furthermore, Policy 2.8 of the Land Use Element
promotes the rehabilitation of commercial properties, and
encourages increased levels of capital investment. The Santa
Ana Arts Collective adaptive reuse project will include
significant improvements to a building that has remained
underutilized in recent years and will include additional
investment in new construction. Finally, Policy 5.5 of the Land
Use Element encourages development that is compatible with
and supporting of surrounding land uses. The project will be
located in a primarily commercial area and its operations will
be compatible with the surrounding commercial businesses
and their operations. The parking analysis provided for the
project and the comparable San Diego Affordable Housing
Parking Study indicate that the proposed parking is more
than adequate to meet the needs of the site. Conditions of
approval will also ensure that the project remains compatible
with surrounding land uses.
D. In accordance with the California Environmental Quality Act, the proposed
project is categorically exempt from CEQA review per Section 15332, The
Cuss 32 exemption applies to projects characterized as infill development
meeting the following conditions: the project is consistent with the
applicable general plan designation and all applicable general plan
policies as well as with applicable zoning designation and regulations; the
proposed development occurs within city limits on a project site of no more
than five acres substantially surrounded by urban uses; the project site
has no value as habitat for endangered, rare or threatened species;
approval of the project would not result in any significant effects relating to
traffic, noise, air quality, or water quality; and the site can be adequately
served by all required utilities and public services.
In analyzing the variance application, staff finds that the
project qualifies for the Class 32 exemption. The project is
consistent with the applicable general plan designation and
all applicable general plan policies as well as with applicable
zoning designation and regulations through the Adaptive
Reuse Ordinance. As proposed, the project will meet the
intent and standards of the General Plan Land Use Element
and SP -3 zoning district standards. Moreover, the proposed
development will take place within city limits and is on a
Resolution No, 2016 -xx
31 D -45 Page 3 of 7
project site that is less than five acres in size and is
surrounded by urban uses. The project site has no value as
habitat for endangered, rare, or threatened species and is
not identified in the General Plan as having such value.
Approval of the project will not result in any significant effects
relating to traffic, noise, air quality, or water quality. The
City's Planning Division and Public Works Agency have
reviewed the proposed project and have determined that the
amount of traffic, noise, air quality impacts, or water quality
impacts are below thresholds that would warrant further
analyses. Finally, the site is already served by all required
utilities and public services as it is located within a heavily -
urbanized area near the intersection of Main and
Seventeenth streets. Based on this analysis, a Notice of
Exemption for Environmental Review No. 2016 -17 will be
filed for this project.
Section 2. The applicant agrees to indemnify, hold harmless, and defend the
City of Santa Ana, its officials, officers, agents, and employees, from any and all liability,
claims, actions or proceedings that may be brought arising out of its approval of this
project, and any approvals associated with the project, including, without limitation, any
environmental review or approval, except to the extent caused by the sole negligence of
the City of Santa Ana.
Section 3. The Planning Commission of the City of Santa Ana after conducting
the public hearing hereby approves Variance No. 2016 -04 as conditioned in Exhibit A,
attached hereto and incorporated herein for the project located at 1666 North Main
Street. This decision is based upon the evidence submitted at the abovesaid hearing,
which includes, but is not limited to: the Request for Planning Commission Action dated
May 9, 2016, and exhibits attached thereto and the public testimony, written and oral, all
of which are incorporated herein by this reference.
ADOPTED this 9th day of May, 2016,
AYES: Commissioners:
NOES: Commissioners:
ABSENT: Commissioners:
ABSTENTIONS: Commissioners:
Resolution No. 2016 -xx
31 D -46 Page 4 of 7
James Gartner
Chairperson
APPROVED AS TO FORM:
Sonia R. Carvalho, City Attorney
Lisa Storck
Assistant City Attorney
CERTIFICATE OF ATTESTATION AND ORIGINALITY
I, ROSA BARELA, Acting Recording Secretary, do hereby attest to and certify the
attached Resolution No. 2016 -xx to be the original resolution adopted by the Planning
Commission of the City of Santa Ana on May 9, 2016,
Date:
Acting Recording Secretary
City of Santa Ana
Resolution No. 2Q16 -xx
31 D -47 Page 5 of 7
EXHIBIT A
Conditions of Approval
Should the Planning Commission approve Variance No. 2016 -04, the approval is
subject to compliance, to the reasonable satisfaction of the Planning Manager, with all
applicable sections of the Santa Ana Municipal Code, the California Administrative
Code, the California Building Standards Code and all other applicable regulations.
The applicant must comply in full with each and every condition listed below prior to
exercising the rights conferred by this variance.
The applicant must remain in compliance with all conditions listed below throughout the
life of the variance. Failure to comply with each and every condition may result in the
revocation of the variance.
1. All proposed improvements must conform to the Development Project Review
approval of DI' No. 2016 -09 and the staff report exhibits.
2. Prior to submittal into Building plan check, the applicant shall establish the
location of a trash pickup staging area through coordination among the Planning
Division, Public Works Agency, and trash service provider.
3. Prior to submittal into Building plan check, the applicant shall provide the
Planning Division and Public Works Agency two copies of an approved parking
management plan for residents, visitors /guests, and patrons of any events or
commercial activities. The parking management plan shall contain information
on number of parking spaces assigned to each unit, parking permits, and on- or
off -site parking and valet strategies for any special events.
4. Prior to submittal into Building plan check, the applicant must provide the Public
Works Agency and Planning Division an authorization from the adjacent property
owner to the south of the project site for the relocation of the driveway approach
along the adjacent owner's property frontage on Sycamore.
6. Prior to submittal into Building plan check, the applicant shall submit street
improvement plans that, among other requirements, indicate the removal of
parking restrictions where possible along the property's frontage on Sycamore
Street,
6. Prior to issuance of building permits, applicant shall submit detailed landscape,
furnishing, lighting, and irrigation plans to the Planning Division for review and
approval.
Resolution No. 2016 -xx
31 D -48 Page 6 of 7
7. Any amendment to this variance must be submitted to the Planning Division for
review. At that time, staff will determine whether administrative relief is available
or the variance must be amended.
Resolution No. 2016 -xx
31 D -49 Page 7 of 7
31 D -50