Laserfiche WebLink
HOMEOWNER: THANH LE <br />PH: 714.722.8071 <br />ADDRESS: 1006 S. AUSTIN STREET UNIT #2 <br />SANTA ANA, CA 92704 <br />DATE: 7/20/22DATE: 7/20/22 <br />(&262/$5 86$ <br />(/(&75,&$///& <br />13962 SEABOARD CIRCLE <br />GARDEN GROVE, CA 92840 <br />PH: 714.265.9077 DAVID Q HOANG C10 - 1045300 <br />6&23(2):25. <br />INSTALL (5) SUNPOWER SPR-M425-H-AC SOLAR <br />ELECTRIC MODULES ON THE EXISTING 1ST STORY <br />COMPOSITION ROOF. INSTALL ASSOCIATED <br />MOUNTING HARDWARE, JUNCTION BOXES, <br />CONDUIT, CONDUCTORS AND GROUNDING. INSTALL <br />(1) AC DISCONNECT, AND INSTALL OCPD IN SUB PANEL. <br />9,&,1,7<0$3 <br />LE <br />RESIDENCE <br />6+((7,1'(; <br />SHEET 1 PROJECT INFO, VICINITY MAP, NOTES, SCOPE OF WORK <br />SHEET 2 SITE/ROOF PLAN, ELEVATION DETAIL <br />SHEET 3 ELECTRIC LINE DRAWING, GROUNDING DETAIL <br />SHEET 4 CALCULATIONS, SIGNS <br />ATTACHED MODULE, INVERTER, MOUNTING HARDWARE SPEC SHEETS, <br />STRUCTURAL REPORT <br />NTS <br />6+((7 <br />127,&( <br />$1<&+$1*(67225 86(62)7+(6('2&80(176'5$:,1*6:,7+2877+( <br />:5,77(1&216(172)-(11,)(5 .(00(25 6&277+$55,6$5(675,&7/<352+,%,7(' <br />2) <br />PLANS PREPARED BY: <br />JENNIFER KEMME <br />PH: 909.748.1300 <br />*(1(5$/127(6 <br />1. THIS SYSTEM COMPLIES WITH THE 2019 CRC, 2019 CBC, 2019 CFC, AND THE 2019 <br />CEC. <br />2. THE SYSTEM WILL NOT BE TURNED-ON UNTIL THE SERVING UTILITY COMPANY <br />HAS BEEN NOTIFIED. <br />3. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT LESS THAN 4 PSF. <br />4. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 40 LBS. <br />5. ALL PV EQUIPMENT IS LISTED BY A RECOGNIZED TESTING LAB. INVERTERS ARE <br />UL 1741 COMPLIANT. <br />6. THE BACKFED BREAKER WILL BE LOCATED AT THE OPPOSITE END OF THE BUS <br />FROM THE MAIN BREAKER. <br />7. CONDUCTORS ARE 90° C RATED COPPER WIRE. <br />8. ANY CONDUCTORS EXPOSED TO SUNLIGHT ARE LISTED AS SUNLIGHT <br />RESISTANT. <br />9. IF DC CONDUCTORS ARE RUN INSIDE THE BUILDING, THEY WILL BE CONTAINED <br />IN A METAL RACEWAY. <br />10. ANY CONDUCTORS BETWEEN SEPARATE ARRAYS ON THE ROOF WILL BE <br />PROTECTED IN CONDUIT. <br />11. THE EQUIPMENT GROUNDING CONDUCTOR ON THE ROOF WILL BE PROTECTED <br />FROM PHYSICAL DAMAGE. IT WILL BE TUCKED NEATLY UNDER THE MODULES <br />AND RAILS AND SECURED IN PLACE. <br />12. THE MODULES WILL BE ATTACHED TO THE EQUIPMENT GROUNDING <br />CONDUCTOR IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. <br />13. ALL EXTERIOR CONDUIT, FITTINGS AND BOXES ARE RAIN-TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS. <br />14. CLEARANCES AROUND ALL ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />15. SOLAR MODULES WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL OR <br />BUILDING ROOF VENTS. <br />16. IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE A VERIFIABLE <br />GROUNDING ELECTRODE SYSTEM, A GROUNDING ELECTRODE SYSTEM WILL BE <br />INSTALLED PER CEC 250.50.THE ELECTRICAL SERVICE WILL BE BONDED TO THE <br />WATER AND GAS PIPING PER SECTION 250.104 OF THE CEC. <br />17. A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CAL-OSHA <br />REGULATIONS. <br />(5) SUNPOWER SPR-M425-H-AC <br />AC MODULES <br />PEAK POWER = 425 W <br />MAX OUTPUT CURRENT = 1.60 A <br />MAX OCPD = 20 A <br />MAX NUMBER IN SERIES = 10 <br />TEMP. COEFF. OF POWER = -0.29%/°C <br />DIMENSIONS = 73.7" X 40.6" X 1.3" <br />WEIGHT = 48.0 LBS <br />3+27292/7$,&62/$5 352-(&7,1)250$7,21 <br />SYSTEM SIZE: 2.125 kW (DC), 1.920 kW (AC) <br />MODULES: <br />ARRAY:INSTALLED WEIGHT = 2.8 PSF <br />ROOF COVERAGE = 105 SF, <br />ARRAYS COVER 7% OF TOTAL ROOF AREA <br />MOUNTING HARDWARE: SUNPOWER INVISIMOUNT <br />UNIRAC FLASHKIT PRO <br />ROOF ATTACHMENTS <br />5 16" STAINLESS STEEL LAG BOLTS @ <br />64" OC OR LESS WITH A MINIMUM OF <br />21 2" PENETRATION INTO ROOF RAFTERS <br />EXISTING ROOF INFO: 1 STORY, ASPHALT SHINGLE <br />2 X 6 RAFTERS @ 16" OC <br />BLDG # 101111603 <br />ELEC # 20177074 <br />ISSUED: 8/11/2022 <br />1006 S Austin St <br />Unit 208/12/22