My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
615 W Park Ln - Plan
PBA
>
Building
>
ProjectDox
>
P
>
Park Ln
>
615 W Park Ln
>
615 W Park Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 4:53:32 PM
Creation date
5/30/2025 8:01:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20177786
101112554
101114458
Full Address
615 W Park Ln
Document Relationships
101112554 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\615 W Park Ln
101114458 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\615 W Park Ln
20177786 - Permit
(Permit - Plan)
Path:
\Building\Permits\P\Park Ln\615 W Park Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ACD INVMSP <br />UM <br />65'-11" <br />11 <br />7 <br />' <br />- <br />8 <br />" <br />11 <br />7 <br />' <br />- <br />8 <br />" <br />65'-11" <br />3'-10" <br />29 <br />' <br />- <br />9" <br />5'-10" <br />39 <br />' <br />- <br />7" <br />1 <br />PROJECT DESCRIPTION: <br />PLOT PLAN & VICINITY MAP <br />SCALE: 1/16" = 1'PV-1 <br />SCALE: NTS PV-1 <br />PLOT PLAN & <br />VICINITY MAP <br />23X370 LONGI SOLAR:LR4-60HPH 370M 370W MODULE <br />ROOF MOUNTED SOLAR PHOTOVOLTAIC MODULES <br />SYSTEM SIZE: 8.51KW DC STC,6.00 kW AC CEC <br />REV <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />DATE DESCRIPTION <br />REVISIONS <br />Signature with Seal <br />PROJECT NAME & ADDRESS <br />PV-1 <br />PROJECT ID <br />JO <br />S <br />H <br /> <br />M <br />C <br />H <br />A <br />L <br />F <br />F <br />E <br />Y <br />61 <br />5 <br /> <br />W <br /> <br />P <br />A <br />R <br />K <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br />U <br />S <br />A <br />FRESH08/31/2022 ORIGINAL PLAN <br />2065 W OBISPO AVE #102 <br />GILBERT, AZ 85233 USA <br />866-572-2637 <br />LIC # CA-1019100 <br />ABHISHEK MAHESH <br />A10/11/2022 REV <br />B11/15/2022 REV <br />C12/30/2022 REV <br /> ROOF ACCESS POINT <br />ROOF ACCESS POINT SHALL NOT BE LOCATED IN <br />AREAS THAT DO NOT REQUIRE THE PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH <br />AS WINDOWS OR DOORS, AND LOCATED AT <br />STRONG POINTS OF BUILDING CONSTRUCTION <br />IN LOCATIONS WHERE THE ACCESS POINT DOES <br />NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS <br />SUCH AS TREE LIMBS, WIRES OR SIGNS. <br />ARRAY LOCATIONS <br />VICINITY MAP <br />SCALE: NTSPV-1 <br />2 HOUSE PHOTO <br />EQUIPMENT SUMMARY <br />23 - LONGI SOLAR:LR4-60HPH 370M 370W MODULES <br />01 - SOLAREDGE TECHNOLOGY:SE6000H-US (240V) INVERTER <br />23 - SOLAREDGE POWER OPTIMIZERS S-440 <br />PROJECT SITE <br />SHEET INDEX <br />PV-1 PLOT PLAN & VICINITY MAP <br />PV-2 ROOF PLAN & MODULES <br />PV-3 STRING LAYOUT <br />PV-4 ATTACHMENT DETAIL <br />PV-5 ELECTRICAL LINE DIAGRAM <br />PV-6 WIRING CALCULATIONS <br />PV-7 PLACARDS <br />PV-8 OPTIMIZER CHART <br />PV-9 EQUIPMENT ELEVATION <br />PV-10+ EQUIPMENT SPECIFICATIONS <br />3 <br />PAGE 1 OF 19 <br />NOTES <br />1. NOTIFY SERVING UTILITY BEFORE <br />ACTIVATION OF PV SYSTEM. <br />2. MANUFACTURERS PRODUCT INSTALLATION <br />INSTRUCTIONS SHALL BE AVAILABLE AT THE <br />TIME OF INSPECTION. <br />3. ALL SUBMITTALS WILL COMPLY WITH 2019 <br />CEC, CBC, AND CFC. <br />4. SMOKE ALARMS AND CARBON MONOXIDE <br />DETECTOR EQUIPMENT SHALL BE IN PLACE <br />AT RESIDENCE ACCORDING TO THE CRC, <br />CBC R314-315 REQUIREMENT. <br />AHJ - SANTA ANA <br />UTILITY - SCE <br />ACCOUNT # - CA-R-195141 <br />GOVERNING CODES <br />THIS PROJECT SHALL COMPLY WITH THE <br />FOLLOWING CODE <br />2019 CALIFORNIA ELECTRICAL CODE <br />2019 CALIFORNIA RESIDENTIAL CODE <br />2019 CALIFORNIA BUILDING CODE <br />2019 CALIFORNIA FIRE CODE <br />2019 CALIFORNIA GREEN BUILDING <br />STANDARDS CODE <br />2019 CALIFORNIA ENERGY CODE <br />2019 CALIFORNIA PLUMBING CODE <br />2020 NATIONAL ELECTRICAL CODE <br />ALL OTHER ORDINANCES ADOPTED BY <br />THE LOCAL GOVERNING AGENCIES. <br />(E) GATE <br />(E) FENCE <br />ROOF #03 <br />(02) LONGI SOLAR LR4-60HPH <br />370M 370W MODULES <br />ROOF ACCESS POINT <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LI <br />N <br />E <br />PROPERTY LINE <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />1-STORY <br />HOUSE <br />EXISTING <br />DRIVEWAY <br />(N) MAIN SERVICE PANEL, <br />200A RATED, 240V, <br />(SEMI-FLUSH MOUNT) <br />(SIEMENS MC2442B1200EFV) <br />(E) UTILITY METER (N) SOLAREDGE TECHNOLOGY <br />: SE6000H-US INVERTER <br />INTEGRATED RAPID <br />SHUTDOWN <br />(N) AC DISCONNECT <br />ROOF #01 <br />(19) LONGI SOLAR LR4-60HPH <br />370M 370W MODULES <br />W PARK LN <br />(E) DETACHED <br />STRUCTURE <br />ROOF #02 <br />(02) LONGI SOLAR LR4-60HPH <br />370M 370W MODULES <br />REVISION BLDG # 101114458 ISS. 03/30/2023 <br />Revision to 101112554 ISS. 10/31/2022 <br />The scope of the plans is for the installation of the solar <br />photovoltaic system only and the approval is subject to <br />compliance with all applicable city and state codes and <br />regulations regarding construction. The approval of the <br />plans does not constitute any certification of the accuracy, <br />completeness, or building permit status of the existing <br />buildings and structures as shown. <br />615 W Park Ln <br />04/03/23
The URL can be used to link to this page
Your browser does not support the video tag.