Laserfiche WebLink
116'-8" <br />63 <br />' <br />-3 <br />" <br /> <br />117'-3" <br />63 <br />' <br />-2 <br />" <br />44'-7"7' <br />- <br />5 <br />" <br />25'-7" <br />17 <br />' <br />- <br />7 <br />" <br />SATELLITE VIEW <br />SCALE: NTS <br />SCALE: NTS <br />COVER SHEET <br />SHEET NAME <br />SHEET SIZE <br />SHEET NUMBER <br />ANSI B <br />11" X 17" <br />SIGNATURE WITH SEAL <br />PROJECT NAME & <br />ADDRESS <br />CS <br />DATE: 1/17/2024 <br />11 <br />0 <br />5 <br /> <br />S <br /> <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />, <br /> <br />9 <br />2 <br />7 <br />0 <br />4 <br />JO <br />R <br />G <br />E <br /> <br />M <br />A <br />G <br />A <br />L <br />L <br />O <br />N <br /> R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />DESCRIPTION DATE REV <br />REVISIONS <br />INITIAL DESIGN 1/17/2024 00 <br />LEVION CONSTRUCTION LLC <br />2020 IOWA AVE SUITE 103, <br />RIVERSIDE, CA 92507 <br />CONTRACTOR LIC#: #1096696 <br />PHONE #: 951-554-2201 <br />GENERAL B <br />ZACHARY WINGER <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />11 MODULES-ROOF MOUNTED - 4.400 KW DC, 4.019 KW AC, 1105 S KAREN AVE, SANTA ANA, CA 92704 <br />2 <br />CS <br />3 <br />CS <br />N <br />GENERAL NOTES: <br />a. INSTALLATION OF SOLAR <br />PHOTOVOLTAIC SYSTEM SHALL BE IN <br />ACCORDANCE WITH CEC AND ALL <br />OTHER APPLICABLE CEC CODES <br />WHERE NOTED OR EXISTING. <br />b. PROPER ACCESS AND WORKING <br />CLEARANCE AROUND EXISTING AND <br />PROPOSED ELECTRICAL EQUIPMENT <br />WILL COMPLY WITH CEC. <br />c. ALL CONDUCTORS, INCLUDING THE <br />GROUNDING ELECTRODE CONDUCTOR <br />SHALL BE PROTECTED FROM PHYSICAL <br />DAMAGE IN ACCORDANCE WITH CEC <br />d. THE PV MODULES ARE CONSIDERED <br />NON-COMBUSTIBLE; THIS SYSTEM IS <br />UTILITY INTERACTIVE PER UL 1741. <br />e. ALL DC WIRES SHALL BE SIZED <br />ACCORDING TO CEC <br />f. DC CONDUCTORS SHALL BE WITHIN <br />PROTECTED RACEWAYS <br />g. ALL SIGNAGE TO BE PLACED IN <br />ACCORDANCE WITH LOCAL <br />JURISDICTIONAL BUILDING CODE. <br />h. PV MODULES TO BE RATED UL 1703 <br />CLASS C FIRE RATING OR BETTER. <br />i. ALL EQUIPMENT TO BE CERTIFIED BY A <br />NATIONAY RECOGNIZED TESTING <br />LABORATORY. <br />j. A 36" WIDE PATHWAY SHALL BE <br />PROVIDED TO THE EMERGENCY <br />ESCAPE AND RESCUE OPENING. <br />k. PV ARRAYS SHALL BE LOCATED AT <br />LEAST 2H2 (2 TIMES THE MAXIMUM <br />HEIGHT OF THE MODULES ABOVE ROOF <br />DECK) FROM THE ROOF EDGE, A GABLE <br />RIDGE OR A HIP RIDGE. (ASCE 7-16 – <br />29.4.4) <br />l. MODULES ARE TO BE AT 2” MINIMUM <br />AND 10” MAXIMUM FROM THE ROOF <br />DECK. (ASCE 7-16 – 29.4.4) <br />SYSTEM SIZE: 4.400 kW DC <br /> 4.019 kW AC <br />MODULE TYPE & AMOUNT: (11) CANADIAN SOLAR CS6R-400MS-HL [BLK] <br />MODULE DIMENSIONS: (L/W/H) 67.80"/44.60"/1.38" <br />MICRO-INVERTER: (11) ENPHASE ENERGY IQ8PLUS-72-2-US [240V] <br />BATTERY: (1) ENPHASE IQBATTERY-5P-1P-NA PARTIAL BACKUP <br />INTERCONNECTION METHOD: BACKFEED IN MSP <br />UTILITY COMPANY: SCE <br />PHOTOVOLTAIC SYSTEM SPECIFICATIONS: <br />SCALE: 15/256" = 1'-0" <br />1 PLOT PLAN <br />CS <br />SHEET INDEX <br />CS COVER SHEET <br />A1.0 SITE PLAN <br />A2.0 MOUNTING DETAILS <br />E1.0 NOTES <br />E2.0 ELECTRICAL LINE DIAGRAM <br />P1.0 WARNING LABELS <br />SS1+ EQUIPMENT SPECIFICATIONS <br />NEW EXTERIOR MAIN SERVICE <br />PANEL & POINT OF <br />INTERCONNECTION TIED TO <br />EXTERIOR UTILITY METER IN THE <br />SAME LOCATION AS OLD MSP <br />FENCE <br />ROOF ACCESS POINT <br />DR <br />I <br />V <br />E <br />W <br />A <br />Y <br />NOTE <br />-NO ACTIVE FIRE SPRINKLER. <br />-NOTIFY SERVING UTILITY BEFORE ACTIVATION OF PV SYSTEM <br />-DO NOT COVER MECHANICAL AND PLUMBING VENTS ON THE ROOF <br />WITH SOLAR PV PANELS. <br />-A ROOF ACCESS POINT SHOULD BE PROVIDED THAT DOES NOT PLACE <br />A GROUND LADDER OVER AN OPENING SUCH AS A WINDOW OR DOOR. <br />LOCATED AT A SOLID POINT IN THE BUILDING CONSTRUCTION AND IN <br />THE LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />EXISTING SHED DETACHED <br />STRUCTURE NO ELECTRICAL <br />"NOTE- ALL ROOF PENETRATIONS WILL BE SEALED AND MADE <br />WEATHER TIGHT WITH APPROVED MATERIALS. <br />NOTE- THERE IS NO OBSTRUCTION OR INTERFERENCE WITH THE <br />FUNCTION OF PLUMBING VENTS OR MECHANICAL EQUIPMENT, WITH A <br />6 INCH MINIMUM OF SEPARATION. THERE WILL BE NO OBSTRUCTIONS <br />AND MINIMUM CLEARANCES IS MAINTAINED." <br />ROOF ACCESS POINT <br />SCOPE OF WORK- INSTALLATION OF FLUSH ROOF MOUNTED SOLAR PV SYSTEM 4.400 KW DC, 4.019 KW AC INCLUDES <br />11 MODULES AND 11 ENPHASE MICROINVERTERS, IQ COMBINER, AC DISCONNECT, IQ CONTROLLER, NEW SUB PANEL <br />AND INSTALLATION OF BATTERY. <br />ESS SYSTEM: <br />NUMBER AND TYPE ESS UNIT(S): 1 X (N) ENPHASE IQBATTERY-5P-1P-NA PARTIAL BACKUP, 5 KWH, 3.84 KVA, EXISTING - 0 <br />ESS UNIT(S) CAPACITY (KWH/UNIT): NEW - 5 KWH/PER LI-ION. EXISTING - 0 <br />OUTDOORS ON EXTERIOR WALLS: 1 UNIT AT 5 KWH TOTAL = 5.00KWH <br />A SINGLE, VISIBLE-OPEN, LOCKABLE AC DISCONNECT SHALL BE WITHIN THREE FEET OF THE METER ON THE EXTERIOR <br />OF THE BUILDING PER FIRE CODE (15.24.025 AMENDMENTS TO THE CALIFORNIA ELECTRICAL CODE) <br />DIG ALERT (811) IS TO BE CONTACTED AND COMPLIANCE WITH EXCAVATION SAFETY IN ACCORDANCE WITH <br />GOVERNMENT CODE 4216 WILL BE FOLLOWED, PRIOR TO ANY EXCAVATION TAKING PLACE. <br />PV SYSTEM SHALL NOT OBSTRUCT OR INTERFERE WITH THE FUNCTION OF VENTS OR MECHANICAL EQUIPMENT; MIN 6” <br />SEPARATION REQUIRED (CMC 304.1, CPC 906, SPG PART 5 SECT. 8), OR ENGINEER DESIGN IS REQUIRED (CPC 301.5). <br />SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN <br />ROOF #1 <br />(02) CANADIAN SOLAR CS6R-400MS-HL [BLK] <br />SLOPE: 14° <br />AZIM.: 180° <br />11 <br />0 <br />5 <br /> <br />S <br /> <br />K <br />A <br />R <br />E <br />N <br /> <br />A <br />V <br />E <br />FR <br />O <br />N <br />T <br /> <br />O <br />F <br /> <br />H <br />O <br />U <br />S <br />E <br />MAIN <br />HOUSE <br />1 STORY <br />GOVERNING CODES <br />ALL WORK SHALL CONFORM TO THE FOLLOWING CODES <br />1. 2022 CALIFORNIA ELECTRICAL CODE <br />2. 2022 CALIFORNIA FIRE CODE <br />3. 2022 CALIFORNIA BUILDING CODE <br />4. 2022 CALIFORNIA RESIDENTIAL CODE <br />5. 2022 CALIFORNIA ENERGY CONSERVATION CODE <br />6. 2022 CALIFORNIA EXISTING BUILDING CODE <br />7. 2022 CALIFORNIA MECHANICAL CODE <br />8. 2022 CALIFORNIA PLUMBING CODE <br />9. 2022 CALIFORNIA HISTORICAL BUILDING CODE <br />10. ANY OTHER LOCAL AMENDMENTS <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />LI <br />N <br />E <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br />PROPERTY LINE <br />PROPERTY LINE <br />M <br />ROOF #2 <br />(04) CANADIAN SOLAR CS6R-400MS-HL [BLK] <br />SLOPE: 14° <br />AZIM.: 90° <br />ROOF #3 <br />(05) CANADIAN SOLAR CS6R-400MS-HL [BLK] <br />SLOPE: 14° <br />AZIM.: 270° <br />FENCE <br />11 <br />' <br />- <br />11 <br />" <br />11'-11" <br />8' <br />- <br />1 <br />1 <br />" <br />17'-1" <br />IF EXISTING UFER NOT FOUND, REQ'D 5/8" <br />DIA. GROUND ROD,8'-0" MIN EMBEDMENT <br />AND REQ'D 6'-0" APART BTWN TWO <br />GROUNDINGS. <br />STRUCTURAL ONLY <br />Bldg#: 10112002 <br />Elec#: 20183391 <br /> <br />Approvals: <br />Elec: M Smith <br />1105 S Karen Ave <br />8/22/2024