My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3110 & 3112 S Griset Pl - Plan
PBA
>
Building
>
ProjectDox
>
G
>
Griset Pl
>
3112 S Griset Pl
>
3110 & 3112 S Griset Pl - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2025 12:44:22 PM
Creation date
6/15/2025 12:43:54 PM
Metadata
Fields
Template:
Plan
Permit Number
101122356
Full Address
3112 S Griset Pl
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
69
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
All ideas, drawings,specifications shown herein are the <br />property of West Coast Design Group and shall not be <br />used, copied, reproduced, or disclosed to any person, firm <br />or corporation, without the written consent of West Coast <br />Design Group. Any infringement will be subject to legal <br />action. The contractor shall verify and be responsible for all <br />dimensions and conditions on the job and notify this office of <br />any variations from dimensions and conditions shown <br />herewith. Written dimensions take precedence over scaled <br />dimensions. <br />Mark Transmittal Set Date Description <br />01 12/19/2024 <br />SHEET TITLE <br />GN-1 <br />SHEET 11 <br />PROJECT NO: <br />STATUS: <br />DRAWN BY: <br />CHK'D BY: <br /> <br /> <br />PROJECT: <br />CLIENT: <br />PLOT DATE: 12/19/2024 <br /> 52-24 <br />PLAN CHECK#:- <br /> C <br />: <br />\ <br />U <br />s <br />e <br />r <br />s <br />\ <br />j <br />e <br />r <br />r <br />y <br />\ <br />D <br />o <br />c <br />u <br />m <br />e <br />n <br />t <br />s <br />\ <br />D <br />r <br />a <br />w <br />i <br />n <br />g <br />s <br />\ <br />R <br />e <br />s <br />i <br />d <br />e <br />n <br />t <br />i <br />a <br />l <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />An <br />a <br /> <br />Gr <br />i <br />s <br />e <br />t <br /> <br />PI <br />\ <br />C <br />D <br />\ <br />S <br />a <br />n <br />t <br />a <br /> <br />A <br />n <br />a <br /> <br />G <br />r <br />i <br />s <br />e <br />t <br /> <br />P <br />I <br />. <br />p <br />l <br />n <br /> Submittal <br /> <br />Symbols/ Legends & Notes <br />ADU <br />3112 S Griset Pl <br />Santa Ana, CA 92704 <br />Matthew Mallari & <br />Natalie Nguyen <br />PLANNING - DESIGN <br />41055 CHACO CANYON ROAD <br />MURRIETA CA 92562 <br />WEST COAST <br />DESIGN GROUP <br />EXTERIOR WALL: 2X6 WOOD STUDS AT 16" O.C. WITH BATT INSULATION IN THE CAVITY. <br />SEE EXTERIOR ELEVATIONS FOR THE EXTERIOR FINISH. <br />INTERIOR WALL: 2X4 WOOD STUDS AT 16" O.C. WITH GYP. BD. FINISH. PLUMBING <br />WALLS TO HAVE 2X6 WOOD STUDS AT 16" O.C. <br />GYP. BD. <br />GYP. BD. <br />WOOD <br />STUDS <br />GYP. BD. <br />EXTERIOR FINISH <br />WOOD <br />STUDS <br />BATT INSUL. <br />SHEATHING PER <br />FRAMING <br />0" <br /># <br />Title 24 Requirements <br />1. EXTERIOR WALLS: R-21 <br />2. ROOF: R-30 <br />3. WINDOWS: <br /> U-FACTOR: .32 <br /> SHGC: .23 <br />4. MINISPLIT DUCTLESS: 8.2 HSPF; 14.0 SEER <br />5. WATER HEATER: SMALL GAS .95 EFF <br />REQUIRED SPECIAL FEATURES: <br />1. COOL ROOF - SEE ROOF PLAN <br />2. EXPOSED SLAB FLOOR IN CONDITIONED ZONE <br />3. NON-STANDARD DUCT LOCATION (ANY LOCATION <br />OTHER THAN ATTIC) <br />4. WHOLE HOUSE FAN <br />FEATURES THAT MUST BE FIELD VERIFIED BY A CERTIFIED HERS RATER: <br />BUILDING LEVEL VERIFICATION: <br />1. HIGH QUALITY INSULATION (QII) <br />2 IAQ MECHANICAL VENTILATION <br />COOLING SYSTEM VERIFICATION: <br />1. MINIMUM AIRFLOW <br />2. FAN EFFICACY WATTS.CFM <br />HVAC DISTRIBUTION SYSTEM VERIFICATION: <br />1. DUCT SEALING <br />2. DUCTS LOCATED ENTIRELY IN CONDITIONED SPACE CONFIRMED BY <br />DUCT LEAKAGE TESTING <br />DOMESTIC HOT WATER VERIFICATION: <br />NONE <br /># <br /># <br />DETAIL TAG <br />DETAIL <br />IDENTIFICATION <br />SHEET WHERE <br />DETAIL IS DRAWN <br />AREA DETAIL <br />REFERENCES <br />DATUM TARGET <br />HEIGHT <br /># <br />SCALE: 1"=1' <br />NAME <br />DRAWING IDENTIFICATION <br />DRAWING TITLE <br />DRAWING SCALE <br /># <br />DOOR NUMBER <br />#WINDOW TAG <br />WINDOW NUMBER <br />KEYNOTE INDICATOR <br /># <br /># <br />BUILDING SECTION TAG <br />SECTION <br />IDENTIFICATION <br />SHEET WHERE <br />SECTION IS DRAWN <br /># <br />INTERIOR ELEVATION TAG <br />SHEET WHERE <br />ELEVATION IS DRAWN <br />ELEVATION <br />IDENTIFICATION <br /># <br /># <br />##INSULATION <br />CONCRETE <br />EARTH <br />WOOD ROUGH <br />WOOD BLOCKING <br />PLYWOOD <br />BRICK <br />Graphic and Material Symbol <br />Wall LegendAbbreviations <br /># Pound OR Number <br />& And <br />@ At <br />ACT Acoustic Ceiling Tile <br />AD Area Drain <br />AFF Above Finished Floor <br />ALUM Aluminum <br />ANOD Anodized <br />BSMT Basement <br />BYND Beyond <br />BOT Bottom <br />CIP Cast In Place <br />CHNL Channel <br />CJ Control Joint <br />CL Center Line <br />CLG Ceiling <br />CLR Clear <br />CMU Concrete Masonry Unit <br />COL Column <br />COMPR Compressible <br />CONC Concrete <br />CONT Continuous <br />CPT Carpet <br />CT Ceramic Tile <br />CTYD Courtyard <br />DBL Double <br />DEMO Demolish or Demolition <br />DIA Diameter <br />DIM Dimension <br />DIMS Dimensions <br />DN Down <br />DR Door <br />DWG Drawing <br />EA Each <br />EJ Expansion Joint <br />EL Elevation <br />ELEC Electrical <br />ELEV Elevator or Elevation <br />EPDM Ethylene Propylene Diene M-Class (Roofing) <br />EQ Equal <br />EXIST Existing <br />EXP JT Expansion Joint <br />EXT Exterior <br />FD Floor Drain or Fire Department <br />FEC Fire Extinguisher Cabinet <br />FF Finished Face or Finished Floor <br />FFL Finished Floor Level <br />FIXT Fixture <br />FLR Floor <br />FM Filled Metal <br />FO Face Of <br />FND Foundation <br />GA Gauge <br />GALV Galvanized <br />GWB Gypsum Wall Board <br />HC Hollow Core <br />HI High <br />HM Hollow Metal <br />HP High Point <br />HR Hour <br />HVAC Heating, Ventilating, And Air Conditioning <br />IRGWB Impact Resistant Gypsum Wall Board <br />ILO In Lieu Of <br />INSUL Insulated or Insulation <br />INT Interior <br />LO Low <br />MAX Maximum <br />MO Masonry Opening <br />MECH Mechanical <br />MEMBR Membrane <br />MIN Minimum <br />MRGWB Moisture-Resistant Gypsum Wall Board <br />MTL Metal <br />NIC Not In Contract <br />NO Number <br />NOM Nominal <br />OC On Center <br />OH Overhang or Opposite Hand <br />OPP Opposite or Opposite Hand <br />OZ Ounce <br />PCC Pre-Cast Concrete <br />PLUMB Plumbing <br />PLYD Plywood <br />PT Pressure Treated <br />PNT Paint or Painted <br />PVC Polyvinyl Chloride <br />RBR Rubber <br />RCP Reflected Ceiling Plan <br />RD Roof Drain <br />REQD Required <br />RM Room <br />SIM Similar <br />SD Smoke Detector <br />SPEC Specified OR Specification <br />SPK Sprinkler or Speaker <br />SSTL Stainless Steel <br />STC Sound Transmission Coefficient <br />STL Steel <br />STRUCTStructure or Structural <br />T&G Tongue And Groove <br />TELE Telephone <br />TLT Toilet <br />TME To Match Existing <br />TO Top Of <br />TOC Top Of Concrete <br />TOS Top Of Steel <br />TPD Toilet Paper Dispenser <br />T/D Telephone/Data <br />TYP Typical <br />UNO Unless Noted Otherwise <br />U/S Underside <br />VIF Verify In Field <br />VP Vision Panel <br />W/ With <br />WD Wood <br />Notes <br />1. NUMBER ONE IT IS THE RESPONSIBILITY OF THE OWNER OR BUILDER <br />TO NOTIFY THE DESIGNER, IN WRITING, OF SUBSTITUTIONS OR FIELD <br />REVISIONS TO THESE PLANS. <br />2. THE DESIGNER WILL IN NO WAY BE RESPONSIBLE FOR THE QUALITY <br />OF MATERIALS OR WORKMANSHIP PROVIDED BY THE OWNER, BUILDER, <br />OR HIS SUBCONTRACTORS. <br />3. THESE PLANS ARE THE PROPERTY OF THE DESIGNER AND ARE <br />INTENDED FOR THE USE ONLY ON THE PROPERTY DESCRIBED ON <br />THESE SHEETS. USE FOR ANY OTHER PURPOSE IS STRICTLY <br />FORBIDDEN WITHOUT THE WRITTEN CONSENT OF THE DESIGNER. <br />4. RESIDENTIAL STREET ADDRESS SHALL BE POSTED WITH A MINIMUM <br />OF 4” NUMBERS, VISIBLE FROM THE STREET AND DURING THE HOUR OF <br />DARKNESS, THE NUMBERS SHALL BE INTERNALLY, ELECTRICALLY <br />ILLUMINATED WITH A LOW VOLTAGE POWER SOURCE. POSTED <br />NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND AND BE VISIBLE <br />AND LEGIBLE FROM THE STREET. WHERE BUILDING SETBACKS EXCEED <br />100 FEET FROM THE ROADWAY OR IF THE CONSTRUCTION IS NOT <br />VISIBLE FROM THE ROADWAY, ADDITIONAL NON ILLUMINATED <br />CONTRASTING 4” NUMBER SHALL BE DISPLAYED AT THE PROPERTY <br />ACCESS ENTRANCE. <br />5. TRASH CONTAINERS AND SANITARY FACILITIES ARE REQUIRED ON ALL <br />CONSTRUCTION SITES. CONSTRUCTION SITES NOT COMPLYING WITH <br />THESE REQUIREMENTS WILL NOT RECEIVE SCHEDULE INSPECTIONS <br />AND RISK REVOCATION OF THE BUILDING PERMIT. <br />6. MATERIALS AND CONSTRUCTION METHODS SHALL COMPLY WITH THE <br />LATEST CALIFORNIA GREEN BUILDING STANDARD CODE LOCATED IN <br />THIS SET OF PLANS. <br />7. AT ROUGH INSTALLATION OR DURING STORAGE ON THE SITE AND <br />UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL <br />DUCT AND OTHER RELATED AIR DISTRIBUTION OPENINGS SHALL BE <br />COVERED WITH TAPE, PLASTIC, SHEET METAL OR OTHER ACCEPTABLE <br />METHODS TO REDUCE DUST OR DEBRIS WHICH MAY COLLECT IN THE <br />SYSTEM. <br />8. PROVIDE INSTALLATION AND INSTALLATION CERTIFICATES TO THE <br />BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION. <br />9. DOMESTIC HOT WATER PIPING SHALL BE INSULATED THROUGHOUT <br />THE PROPOSED STRUCTURE. (MOUNTAIN REGIONS) <br />10. THE ANNULAR SPACES AROUND PIPES, ELECTRICAL CABLES, <br />CONDUITS OR OTHER OPENINGS IN SOLE/ BOTTOM PLATES AT <br />EXTERIOR WALLS SHALL BE PROTECTED AGAINST THE PASSAGE OF <br />RODENTS BY CLOSING SUCH OPENINGS WITH CEMENT MORTAR, <br />CONCRETE MASONRY OR SIMILAR METHODS.
The URL can be used to link to this page
Your browser does not support the video tag.