Laserfiche WebLink
(N) ADU #2 <br />UNIT 1909 <br />748 SF <br />2 BED/2 BATH <br />(N <br />) <br /> <br />4 <br />" <br /> <br />A <br />B <br />S <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />, <br />MI <br />N <br />. <br /> <br />2 <br />% <br /> <br />S <br />L <br />O <br />P <br />E <br />(E) 4" SEWER LINE <br />TO STREET (V.I.F.) <br />(N) WATER LINE: 1" <br />COPPER TYPE "L" OR <br />PEX PIPE, MIN. 18" <br />BELOW GROUND <br />(E) GARAGE <br />603 SF <br />℄ <br />PROPERTY LINE - 135.00' <br />(E <br />) <br /> <br />D <br />E <br />C <br />K <br />40 <br />3 <br /> <br />S <br />F <br />18'-2" <br />(E) GAS <br />METER <br />12'-0" <br />(E) GAS <br />METER <br />(E) GAS <br />METER <br />(E) 2ND FLOOR <br />UNIT #1/2 <br />894 SF <br />(2 BED/1 BATH <br />OVER <br />(E) 1ST FLOOR <br />UNIT #A <br />1,272 SF <br />3 BED/1 BATH <br />S <br />E <br />V <br />E <br />R <br />G <br />R <br />E <br />E <br />N <br /> <br />S <br />T <br />30'-0" TO <br />CENTERLINE <br />4'-0"6'-0" <br />20'-4"10'-8" <br />6'-9" <br />20'-7" <br />38'-3" <br />5'-0" <br />9'-8"24'-6"3'-0"41'-0"5'-0" <br />19'-4" <br />21'-2" <br />20'-1" <br />6'-9" <br />29'-8" <br />27'-0"6'-3"6'-9"37'-3"26'-6"10'-8" <br />31'-0"31'-0" <br />3'-0" <br />PROPERTY LINE - 135.00' <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />- <br /> <br />8 <br />0 <br />. <br />0 <br />0 <br />' <br />(E) 6'H BLOCK WALL <br />(E) WATER <br />METER <br />(E) POWER <br />POLE <br />UPPER FLOOR WALL <br />(E) POWER <br />POLE <br />4:124:12 <br />4:12 <br />(E <br />) <br /> <br />4 <br />- <br />G <br />A <br />N <br />G <br />PA <br />N <br />E <br />L <br />, <br />30 <br />A <br /> <br />E <br />A <br />C <br />H <br />19'-4" <br />29'-8" <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />L <br />I <br />N <br />E <br /> <br />- <br /> <br />8 <br />0 <br />. <br />0 <br />0 <br />' <br />0.5:12 <br />0.5:12 <br />18 <br />" <br /> <br />( <br />T <br />Y <br />P <br />. <br />) <br />18 <br />" <br /> <br />( <br />T <br />Y <br />P <br />. <br />) <br />2% <br />2% <br />2% <br />AC <br />5'-0" <br />19'-0"19'-0" <br />37'-9" <br />(N <br />) <br /> <br />A <br />D <br />U <br /> <br /># <br />2 <br />20 <br />0 <br />A <br /> <br />P <br />A <br />N <br />E <br />L <br />(N <br />) <br /> <br />A <br />D <br />U <br /> <br /># <br />1 <br />20 <br />0 <br />A <br /> <br />P <br />A <br />N <br />E <br />L <br />(N) ADU #1 <br />UNIT 1907 <br />747 SF <br />2 BED/2 BATH <br />(N) PORCH <br />37 SF3'-3" <br />32'-0" <br />11'-6"13'-0" <br />(N <br />) <br /> <br />A <br />D <br />U <br /> <br /># <br />1 <br /> <br />2 <br />0 <br />0 <br />A <br />SU <br />B <br />- <br />P <br />A <br />N <br />E <br />L <br />7'-10" <br />11'-1" <br />(N) PATIO <br />COVER <br />180 SF <br />5'-0" <br />6'-0" <br />14'-1" <br />5'-0" <br />14'-8" <br />5'-0" <br />(N) PORCH <br />142 SF <br />AC <br />20'-0" <br />(E) DRIVEWAY <br />AND IMPERVIOUS <br />SURFACE <br />FRONT YARD <br />LANDSCAPING <br />(PER S.A.M.C. SEC. 41-240) <br />4: <br />1 <br />2 <br />12" (TYP.)12" (TYP.) <br />12" (TYP.) <br />12" (TYP.) <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />4: <br />1 <br />2 <br />10 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />11 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />14 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />AND WALL <br />15 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />AND WALL10 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />4:124:12 <br />4:124:12 <br />11 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />10 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />11 <br />SD-1 <br />1-HR RATED <br />OVERHANG <br />(E) RUMPUS ROOM <br />512 SF <br />(E) LANDSCAPED <br />AND GRASS AREA <br />(E) 8'H BLOCK WALL <br />(N) <br /> <br />4 <br />" <br /> <br />A <br />B <br />S <br /> <br />S <br />E <br />W <br />E <br />R <br /> <br />L <br />I <br />N <br />E <br />, <br />MIN <br />. <br /> <br />2 <br />% <br /> <br />S <br />L <br />O <br />P <br />E <br />3'-0" <br />3'-6" <br />2'-0" <br />5'-0" <br />2' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />5'-0"5'-6" <br />4'-0" <br />4'-0" <br />5'-0"3'-0" <br />4'-0" <br />4'-0" <br />FIRE SEPARATION <br />LINE <br />(N) 3/4" ADU #1 <br />WATER METER <br />(N) 3/4" ADU #2 <br />WATER METER <br />2" SCHD. 80 GRAY CONDUIT, <br />MIN. 18" BELOW GROUND <br />5'-0" <br />FIRE SEPARATION <br />LINE <br />(N) ADU #2 <br />748 SF19'-0" <br />(N) ADU #1 <br />747 SF <br />(N) PORCH <br />37 SF <br />32'-0" <br />(N) PORCH <br />180 SF <br />(N) PORCH <br />142 SF <br />SOLAR ZONE <br />250 SF (38.5'x6.5') <br />SOLAR ZONE 1 <br />125 SF <br />(13.5'x9.25') <br />48'-10" <br />24'-6" <br />3'-0" <br />3'-0" <br />3'-0" <br />3'-0" <br />SOLAR ZONE 2 <br />125 SF <br />(13.5'x9.25') <br />3'-0" <br />3'-0" <br />ATTIC VENTILATION CALCULATION <br />TOTAL ATTIC VENTILATION AREA SHALL NOT BE <br />LESS THAN 1/150 OF THE ATTIC SPACE AREA. <br />1. ADU #1: ATTIC SPACE = 747 + 37 + 142 = 926 SF <br />ATTIC VENTS REQUIRED = 926/150 = 6.2 SF <br />2. ADU #2: ATTIC SPACE = 748 + 180 = 928 SF <br />ATTIC VENTS REQUIRED = 928/150 = 6.2 SF <br />===> PROVIDE 8 VENTS ON THE ADUs, OHAGINTM 14" <br />DIAMETER ROOF VENTS (1.07 SF EACH), AS <br />INDICATED ON ROOF PLAN HEREON <br />PROJECT INFORMATION <br />OWNER:ANDY PHAM <br />TEL.:(714) 548 1937 <br />ADD.:MAIN:1911 S EVERGREEN ST <br />ADU #1:1907 S EVERGREEN ST <br />ADU #2:1909 S EVERGREEN ST <br />SANTA ANA, CA 92707 <br />(E) UNIT A = 1,272 SF <br />(E) UNIT 1/2 = 894 SF <br />(E) RUMPUS ROOM = 512 SF <br />(E) DECK = 403 SF <br />(E) GARAGE = 603 SF <br />(N) ADU #1 = 747 SF (EXEMPT FOR LOT COVERAGE) <br />(N) ADU #1 PORCHES = 37 SF AND 142 SF <br />(N) ADU #2 = 748 SF (EXEMPT FOR LOT COVERAGE) <br />(N) ADU #2 PATIO COVER = 180 SF <br />LOT COVERAGE = 1,272 + 512 + 603 = 2,387 SF <br />TOTAL LIVING AREA = 1,272 + 512 + 894 + 747 + 748 <br /> = 4,173 SF <br />LOT SIZE = 10,800 SF <br />% COVERAGE = 2,387/10,800 = 22.1% <br />APN = TO BE ASSIGNED BY PLANNING <br />ZONE = R1/U <br />FLOOD ZONE = X <br />TYPE OF CONSTRUCTION = VB <br />(E) UNIT'S FIRE SPRINKLER = NOT EQUIPPED <br />APPLICABLE BUILDING STANDARDS <br />1. 2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2. 2022 CALIFORNIA BUILDING CODE (CBC) <br />3. 2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />4. 2022 CALIFORNIA PLUMBING CODE (CPC) <br />5. 2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />6. 2022 CALIF. ENERGY EFFICIENCY STANDARD <br />7. 2022 CALIF. GREEN BUILDING STANDARDS <br />8. CITY OF SANTA ANA ORDINANCES <br />DRAWING INDEX <br />A1 (N) SITE/ROOF PLAN - GENERAL NOTES <br />SOLAR ZONE DEDICATION <br />A2 (E) SITE/ROOF PLAN - (E) FLOOR PLAN <br />A3 (N) ADU FLOOR PLAN <br />A4 ELEVATION - BUILDING SECTIONS <br />DR1-2 DRAINAGE PLAN <br />SN-1 STRUCTURAL GENERAL NOTES <br />S1-2 FOUNDATION PLAN - FRAMING PLAN <br />SD1-2 STRUCTURAL DETAILS <br />T1-4 TITLE 24 PLAN <br />T5-6 GREEN BUILDING STANDARDS CODE <br />SCOPE OF WORK <br />1. BUILD NEW DETACHED 747 SF ADU #1 (2 BEDROOM <br />- 2 BATHROOM) WITH 37 SF AND 142 SF PORCHES <br />2. BUILD NEW DETACHED 748 SF ADU #2 (2 BEDROOM <br />- 2 BATHROOM) WITH 180 SF PORCH <br />CONSTRUCTION NOTES <br />1. CONSTRUCTION WORK HOURS ARE 7AM - 7PM, <br />M-F; 9AM - 7PM, SATURDAY; NO SUNDAY OR LEGAL <br />HOLIDAYS. <br />2. THERE SHALL BE NO TRENCHES OR EXCAVATIONS <br />5' OR MORE IN DEPTH INTO WHICH A PERSON IS <br />REQUIRED TO DESCEND, OR OBTAIN PERMIT FROM <br />STATE OF CA, DIVISION OF OCCUPATIONAL SAFETY <br />AND HEALTH (CAL/OSHA). THIS PERMIT AND ANY <br />OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR <br />TO COMMENCE OF ANY WORK. <br />VICINITY MAP <br />ADU PARKING EXEMPTION NOTE <br />PROPOSED ADU IS LOCATED WITHIN ONE-HALF MILE <br />TO OCTA ROUTE 55 ALONG S STANDARD AVE. AT E <br />OCCIDENTAL ST., PURSUANT TO ASSEMBLY BILL 68, <br />NO PARKING IS REQUIRED FOR THE ADUs. <br />GENERAL NOTES <br />1. ALL WORK PERFORMED SHALL COMPLY WITH THESE GENERAL NOTES (UNLESS NOTED OTHERWISE ON THESE PLANS AND <br />SPECIFICATIONS) AND ALL THE FOLLOWING NOTES, DRAWINGS AND SPECIFICATIONS. GENERAL CONTRACTOR SHALL COORDINATE <br />THE INTENT OF GENERAL NOTES WITH MECHANICAL, ELECTRICAL, AND PLUMBING TRADES. <br />2. THE GENERAL CONTRACTOR OBTAINS AND PAYS FOR ALL REQUIRED PERMITS AND ARRANGES FOR ALL REQUIRED INSPECTIONS. <br />3. ALL WORK SHALL COMPLY WITH LATEST EDITION OF BUILDING CODES AS ADOPTED BY THE CITY OF SANTA ANA AND ALL OTHER <br />APPLICABLE REGULATIONS. <br />4. DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL SITES CONDITIONS, DIMENSIONS AND ELEVATION BEFORE STARTING <br />THE WORK, AND NOTIFY THE DESIGNER OF ANY DISCREPANCY, IN WRITING, PRIOR TO PROCEEDING. <br />5. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN HEREON OR NOT AND TO <br />PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES OF REPAIR OR REPLACEMENT IN CONJUNCTION WITH <br />THE PROSECUTION OF SUCH WORK. <br />6. THE CONTRACTOR SHALL DETERMINE THE LOCATION OF THE UTILITY SERVICES IN THE AREA TO BE EXCAVATED PRIOR TO THE <br />EXCAVATION. <br />7. THE DISCHARGE OF POLLUTANTS TO ANY STORM DRAINAGE SYSTEM IS PROHIBITED. NO SOLID WASTE, PETROLEUM BYPRODUCTS, <br />SOIL PARTICULATE, CONSTRUCTION WASTE MATERIALS, OR WASTEWATER GENERATED ON CONSTRUCTION SITE OR BY THE <br />CONSTRUCTION ACTIVITIES SHALL BE PLACED, CONVEYED OR DISCHARGED INTO THE STREET, GUTTER OR STORM DRAIN SYSTEM. <br />8. ALL NEW ROOF MATERIALS, STUCCO AND WINDOWS SHALL MATCH EXISTING COLOR AND STYLE. <br />EMERGENCY EGRESS NOTES <br />1. MIN. SET CLEAR OPENING OF 5.7 SQUARE FEET. <br />2. MIN. 5 SQUARE FEET FOR GRADE-FLOOR OPENINGS <br />3. MIN. SET CLEAR HEIGHT OF 24 INCHES. <br />4. WINDOW TO BOTTOM OF CLEAR OPENING SHALL BE NO MORE THAN 44 INCHES. <br />STUCCO NOTES <br />1. A CORROSION RESISTANT WEEP SCREED 2" BELOW PLATE, 6" (2" FOR CONCRETE WALKWAY) ABOVE GRADE THAT ALLOWS TRAPPED <br />WATER TO DRAIN TO THE EXTERIOR OF THE BUILDING IS REQUIRED BELOW THE STUCCO AT THE FOUNDATION PLATE LINE. <br />2. 7/8" MIN. THICK THREE-COAT APPLICATION (SCRATCH, BROWN AND FINISH) OVER SELF-FURRING GALVANIZED WIRE LATH OVER <br />GRADE D BUILDING PAPER AND WIRE BACKING. <br />3. EXTERIOR LATH: PROVIDE 2 LAYERS OF GRADE D PAPER OVER SHEATHING OR WOOD STUDS <br />SETBACK AND PROPERTY LINE NOTE <br />THE OWNER/CONTRACTOR SHALL CONSULT WITH A LAND SURVEYOR TO DETERMINE IF A LOT/BOUNDARY SURVEY IS NEEDED TO <br />VERIFY SETBACKS OF EXISTING AND PROPOSED STRUCTURES WITH RESPECT TO PROPERTY LINES. IN THE EVENT THERE IS <br />DISCREPANCY BETWEEN PROPOSAL AND FIELD MEASUREMENTS OF SETBACK, THE DESIGNER SHALL BE NOTIFIED; AND REVISION <br />SHALL BE SUBMITTED FOR CITY APPROVAL. <br />ELECTRICAL METER LOCATION NOTE <br />THE CONTRACTOR SHALL CONTACT SOUTHERN <br />CALIFORNIA EDISON (SCE) @ 800-655-4555 TO <br />OBTAIN A NEW METER SPOT APPROVAL AND <br />INSTALLATION INSTRUCTIONS PRIOR TO INSTALLING <br />THE NEW METER SERVICE PANEL. LOCATION AND <br />AMPERAGE OF NEW METER IN THIS PLAN ARE ONLY <br />PROPOSAL AND SUBJECT TO SCE FINAL APPROVAL. <br />SI <br />T <br />E <br /> <br />P <br />L <br />A <br />N <br />RO <br />O <br />F <br /> <br />P <br />L <br />A <br />N <br />SO <br />L <br />A <br />R <br /> <br />Z <br />O <br />N <br />E <br />DE <br />D <br />I <br />C <br />A <br />T <br />I <br />O <br />N <br />GE <br />N <br />E <br />R <br />A <br />L <br /> <br />N <br />O <br />T <br />E <br />S <br />OW <br />N <br />E <br />R <br />AN <br />D <br />Y <br /> <br />P <br />H <br />A <br />M <br />TE <br />L <br />: <br /> <br />( <br />7 <br />1 <br />4 <br />) <br /> <br />5 <br />4 <br />8 <br /> <br />1 <br />9 <br />3 <br />7 <br />PR <br />O <br />J <br />E <br />C <br />T <br /> <br />A <br />D <br />D <br />R <br />E <br />S <br />S <br />MA <br />I <br />N <br /> <br />U <br />N <br />I <br />T <br />: <br /> <br />1 <br />9 <br />1 <br />1 <br /> <br />S <br /> <br />E <br />V <br />E <br />R <br />G <br />R <br />E <br />E <br />N <br /> <br />S <br />T <br />AD <br />U <br /> <br /># <br />1 <br />: <br /> <br />19 <br />0 <br />7 <br /> <br />S <br /> <br />E <br />V <br />E <br />R <br />G <br />R <br />E <br />E <br />N <br /> <br />S <br />T <br />AD <br />U <br /> <br /># <br />2 <br />: <br /> <br />19 <br />0 <br />9 <br /> <br />S <br /> <br />E <br />V <br />E <br />R <br />G <br />R <br />E <br />E <br />N <br /> <br />S <br />T <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />DATE 2/20/2024 <br />NE <br />W <br /> <br />D <br />E <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />7 <br />4 <br />7 <br /> <br />S <br />F <br />AN <br />D <br /> <br />7 <br />4 <br />8 <br /> <br />S <br />F <br /> <br />A <br />D <br />U <br />s <br />SHEET <br />A1 <br />REVISION <br />DATE BY <br />1 <br />2 <br />3 <br />PROJECT ENGINEER <br />BEN PHAN <br />10822 WOODWARD LN <br />GARDEN GROVE, CA 92840 <br />TEL: (714) 251 4537 <br />LANDSCAPING LEGEND <br />GRASS OR ACCEPTABLE DRY <br />CLIMATE GROUND COVER <br />POP-UP SPRINKLER <br />NEW 5 GAL. JUNIPER BUSH (TYP. 6) <br />NEW 1 GAL. ENCORE AZALEA (TYP. 16) <br />FRUIT TREES ( VARIETY - MAX. 20' APART) <br />NEW 24" BOX KING PALM OR SIMILAR, <br />TREE SHALL BE DOUBLE-STAKED <br />BUILDING NOTES <br />1. ALL CONCEALED WORK INSTALLED <br />WITHOUT PERMITS MUST BE EXPOSED FOR <br />INSPECTION TO THE SATISFACTION OF THE <br />BUILDING INSPECTOR. THIS INCLUDES <br />METHODS OF ATTACHMENT AND ALL <br />FOOTINGS, STRUCTURAL MEMBERS, <br />MECHANICAL, ELECTRICAL, PLUMBING AND <br />INSULATION. <br />2. MECHANICAL, ELECTRICAL AND PLUMBING <br />ARE NOT PART OF THIS PLAN REVIEW AND <br />APPROVAL. MEP ARE SUBJECT TO BUILDING <br />FIELD INSPECTION. <br />FRONT YARD NOTES <br />1.FRONT YARD LANDSCAPING SHALL COMPLY <br />WITH S.A.M.C. SEC. 41-240. <br />2.LANDSCAPING AREAS SHALL BE DESIGNED <br />WITH AN AUTOMATIC IRRIGATION SYSTEM WITH <br />POP-UP SPRINKLERS. DRIP, BUBBLER OR <br />OTHER LOW GALLONAGE SYSTEMS MAY BE <br />USED IN BUFFER AREAS AND NARROW STRIPS. <br />3.FRONT YARD LANDSCAPING, IF NOT PRESENT, <br />SHALL BE RESTORED WITH LIVE VEGETATION <br />(GRASS OR ACCEPTABLE DRY CLIMATE <br />GROUND COVER). <br />4.FENCE IN FRONT YARD SHALL COMPLY WITH <br />S.A.M.C. SEC. 41-610 AND SHALL NOT EXCEED 3' <br />IN HEIGHT. <br />(N) SITE/ROOF PLAN <br />SCALE: 1/8" = 1'-0" <br />SOLAR ZONE DEDICATION <br />SCALE: 3/16" = 1'-0" <br />PHOTOVOLTAIC SYSTEM NOTE <br />1. A MINIMUM 2.04 KWdc AND 2.05 KWdc <br />PHOTOVOLTAIC SYSTEM (PER TITLE 24) <br />SHALL BE INSTALLED ON THE ADU #1 AND #2, <br />RESPECTIVELY, PRIOR TO FINAL INSPECTION <br />SIGN-OFF. THE PV SYSTEM SHALL BE <br />SUBMITTED UNDER A SEPARATE SUBMITTAL. <br />2. SOLAR PERMIT ISSUANCE IS REQUIRED <br />PRIOR TO PERFORMING FRAMING <br />INSPECTION. <br />PLANNING DEPARTMENT NOTE <br />1. THE OWNER SHALL BE RESPONSIBLE FOR <br />INDENTING THE PRESENCE OF ANY <br />EASEMENTS LOCATED ON THE PROPERTY <br />THAT MAY AFFECT THE PROJECT. <br />2. ALL UTILITIES SHALL BE UNDERGROUND. <br />BUILDING SECURITY <br />REGULATIONS <br />FOR NEW BUILDINGS AND ADDITIONS, <br />ALTERATIONS, AND REPAIRS WITHIN <br />ANY TWELVE-MONTH PERIOD EXCEED <br />FIFTY (50 %) PERCENT OF THE VALUE <br />OF ANY EXISTING BUILDING OR <br />STRUCTURE, EACH BUILDING OR <br />STRUCTURE SHALL BE MADE TO <br />CONFORM TO THE REQUIREMENTS FOR <br />NEW BUILDINGS OR STRUCTURES AND <br />COMPLY WITH THE BUILDING SECURITY <br />REGULATIONS. SANTA ANA MUNICIPAL <br />CODE CHAPTER 8, DIVISION 3. <br />ADU SF / SFD SF RATIO <br />1. ADU #1 SF / SFD SF RATIO = 747/1,272 = 0.59 <br />2. ADU #2 SF / SFD SF RATIO = 748/1,272 = 0.59 <br />THE ADU SF / SFD SF RATIO IS FOR PARK & REC. FEE <br />PURPOSE ONLY. THE APPLICANT IS RESPONSIBLE FOR <br />THE GIVEN "SFR SF" OF THE EXISTING PRIMARY <br />RESIDENCE. BUILDING SAFETY STAFF ARE NOT <br />RESPONSIBLE FOR THE ACCURACY OF THE GIVEN "SFR <br />SF" OF THE EXISTING RESIDENCE. <br />HERS SPECIAL FEATURES <br />• COOL ROOF <br />• INSULATION BELOW ROOF DECK <br />• NORTHWEST ENERGY EFFICIENCY ALLIANCE <br />(NEEA) RATED HEAT PUMP WATER HEATER; <br />SPECIFIC BRAND/MODEL, OR EQUIVALENT, MUST <br />BE INSTALLED <br />HERS INSPECTION FEATURES <br />• QUALITY INSULATION INSTALLATION (QII) <br />• INDOOR AIR QUALITY VENTILATION <br />• MINIMUM AIRFLOW <br />• VERIFIED EER/EER2 AND SEER/SEER2 <br />• FAN EFFICACY WATTS/CFM <br />• VERIFIED HEAT PUMP RATED HEATING CAPACITY <br />• DUCT LEAKAGE TESTING <br />Bldg # 101121984-85 <br />APPROVALS: <br />PLNG - F. Arias <br />BLDG - CSG <br />POLICE - B. Martin <br />PUBLIC WORKS - Y. Soto