My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1901 E Dyer Rd - Soils Report
PBA
>
Building
>
Soils Reports
>
D
>
Dyer Rd
>
1901 E Dyer Rd
>
1901 E Dyer Rd - Soils Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2022 1:32:37 PM
Creation date
6/23/2022 1:31:29 PM
Metadata
Fields
Template:
Soils Report
Full Address
1901 E Dyer Rd
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
Alliance Residence October 18,2016 <br />J.N.: 2530.00 <br />Page 8 <br />5.2.3 Landsliding <br />Geologic hazards associated with landsliding are not anticipated at the site. Furthermore, the site is <br />not located within an area identified by the California Geologic Survey (CGS) as having potential <br />for seismic slope instability. <br />5.2.4 Liquefaction <br />Based on our engineering analyses discussed previously, limited thin layers of granular soils are <br />susceptible to liquefaction. However, our analyses also indicate the seismic settlement due to <br />liquefaction is not anticipated to exceed about 1 inch. In consideration of this relatively low <br />magnitude of seismic settlement, no special mitigation is deemed necessary. We also anticipate a <br />sufficient thickness of non-liquefiable soils to be present below the foundations to preclude a loss of <br />bearing while deeper soils are liquefied. <br />5.3 GROUNDWATER <br />As previous discussed, groundwater was reported beneath the site at a depth of approximately 17 to <br />47 feet below the ground surface. Groundwater conditions in the future willlikely vary as a result of <br />seasonal variations of rainfall and future site development. Provided the recommendations <br />contained in this report are incorporated into the construction of the project, adverse effects from <br />future groundwater conditions are not anticipated at the site. <br />5.4 SOIL EXPANSION <br />Based on our review of laboratory test results presented in the referenced reports prepared by GDC <br />and SCG, the near-surface materials within the site are anticipated to possess Medium to High <br />expansion potentials. Provided foundations and improvements are designed in accordance with the <br />recommendations provided herein, adverse effects from expansive soils are not anticipated at the <br />site. <br />5.5 SETTLEMENT <br />The site is underlain by compressible alluvial soils. Our analyses discussed previously indicate that <br />footings supporting a load exceeding 100 kips could undergo more than 1 inch of settlement. As <br />such, footings that support greater loads will require a blanket of fill below the footing to limit total <br />settlement to 1 inch or less. Specific recommendations are provided in Section 6.3. <br />The garage structures are anticipated to result in column loads exceeding 400 kips. Due to the <br />relatively high column loads, the use of a fill blanket below the footings is deemed unpractical. To <br />mitigate this condition, the garage structures will require support by ground improvement methods <br />such as Geopiers (rammed aggregate piers). Specific design requirements for design of garage <br />foundations on ground improvement technologies will require a specialty design contractor to meet <br />the structural requirements. <br />ALBUS-KEEFE & ASSOCIATES, INC.
The URL can be used to link to this page
Your browser does not support the video tag.