Laserfiche WebLink
,'-SANTA <br />NA <br />Ph\\I\G <br />TBTII"DIIC <br />t(;tl0 <br />Planning & Building Agency <br />Building Safety Oivision <br />20 Civic Center Plaza <br />P.O. Box 1988 (M-19) <br />Santa Ana, CA 92702 <br />(714) 647-s800 <br />w\xw.santa-ana.org <br />RES!DENTIAL <br />PHOTOVOLTAIC <br />CHECKLIST <br />1 <br />soL-01 cBc 2013 <br />Project Address:5325 Rhonda Ave., Santa Ana, CA92703 <br />contractor Company Name: Complete Solar <br />Contractor License Number: 961988 C-10 <br />YES NO Are the following applicable to the proposed project? <br />Will the PV system layout provide the required three-foot wide clear access pathways <br />per Section 605.1 1 of the California Fire Code, and is this shown on the roof plan? <br />Will the PV system be installed on a roof having only one roofing layer with no <br />overlays? <br />Will the PV anay be flush mounted to the existing roof so that the plane of the <br />modules (panels) are parallel to the plane of the roof? <br />Will the PV system weigh maximum 4 pounds per square feet or less? <br />Will the PV system be installed where the modules do not overhang any roof edges <br />(such as eaves, gabled ends, ridges and hips)? <br />Will the PV system be installed with a space of 2" minimum to 10" maximum between <br />the underside of modules and the surface of the roof? <br />Will the PV system be installed without using any ballast system or counter-weight <br />system? <br />Will lhe anchors be installed with a maximum horizontal anchor spacing of 6 feet <br />and is this maximum horizontal spacing shown on the plans? <br />Will the minimum 5/16" lag screws be installed with a minimum ol2-112inch <br />embedment into roof rafters (with pre-drilled holes) and is this minimum embedment <br />shown on the plans? <br />Are ALL the structural pages of the plans WET stamped and signed by a Califomia <br />licensed professional engineer? (including project specific site plan, PV layout, <br />anchorage spacing, anchorage details and manufacturer's PV support information.) <br />trD <br />.) <br />3 <br />4 <br />trD <br />Etr <br />qtr <br />Btr <br />trtr <br />trtr <br />6 <br />7 <br />s. gtr <br />9 Eltr <br />10 EID <br />I certiflt under penalty of perjury under the laws of the State of California that the above is true: <br />Print Name: Steve Galindo Signature <br />PhoneNumber: 650-204-4023 Date: 07113118 <br />EmailAddress: permits@completesolar.com <br />Rev: 8/1712015 <br />Solar Photovoltaic (PV) Checklist for Detached SINGLE FAMILY RESIDENCES Only <br />lnstructions: The licensed contractor of record shall complete all sections, answer the ten questions and <br />sign the certiflcation section below. A copy of this form shall be attached to each of TWO sets of plans, of <br />minimum 11"x17" size. lf answerinq NOtoanvof the questions. plan check shall be required. <br />"ara, -