Laserfiche WebLink
NorES FoR SrnN DARD SrnINc SySrru E LECTRICNI DIAC RAM <br />Contactor Name <br />Acldress anc, Phone <br />Notes for One-Line Standard Electrical <br />Dia ram for Sin le-Phase <br />AC Size <br />S <br />Site Address <br />Site Name <br />Drawn 8y <br />SIZ E FSC[,4 NO DITG NO REV <br />Checked By SCALE NTS Date SBEET <br />PV MODULE RATINGS @ STC (Guide Section 5) <br />MoDULE MAKE LONGI SOLAR <br />IVIODULE MODEL LR6-6OHPB-310M <br />tvtAx powER-potNT cuRRENT (rMp) ,9.30 A <br />MAX powER-porNT voLTAGE (vMp) 33.30 v <br />oPEN-c|RCUlr VoLTAGE (voc) 40.30 v <br />sHoRT-clRcurr CURRENT (r"(.) 9.86 A <br />MAX SERIES FUSE (ocPD) 20 A <br />MAXTMUM PowER (PMAX) 310 w <br />MAX VoLTAGE (TYP 6oov,(.) 1000 v <br />VOC TEMP COEFF (mV/oCfl or o/otuCffl) -0.286 <br />IF COEFF SUPPLIED, CIRCLE UNITS <br />NOTES FOR ALL DRAWINGS: <br />OCPD = OVERCURRENT PROTECTION DEVICE <br />NATIONAL ELECTRICAL CODEā‚¬ REFERENCES <br />sHowN AS (NEC XXX XX) <br />INVERTER RATINGS (Guide Section 4) <br />INVERTERMAKE SOLAREDGE <br />TNVERTERMoDEL SE3800H-USRGM [Sl1] <br />MAX DC volr RAING 380 v <br />MAX PowER @ 4o"c i aaoo w <br />NoMTNAL AC voLTAGE 480 v <br />rvrAx AC CURRENT I 16 A <br />MAX ocpD RATTNG 20 A <br />SIGNS-SEE GUIDE SECTION 7 <br />SIGN FOR DC DISCONNECT <br />PHOTOVOLTAIC POWER SOURCE <br />RATED MPP CURRENT 12.24 All <br />RATED MPP voLTAGE 380 v <br />I <br />MAX SYSTEM VOLTAGE 480 Vl1 <br />MAX CIRCUIT CURRENT 15 A <br />WARNING, ELECTRICAL SHOCK <br />HAZARD-LINE AND LOAD MAY BE <br />ENERGIZED IN OPEN POSITION <br />NOTES FOR ARRAY CIRCUIT WIRING (Guide Sectron 6 and 8 and Appendix D): <br />1 ) LOWEST EXPECT AMBIENT TEMPERATURE BASED ON ASHRAE MINIMUM MEAN <br />EXTREME DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION LOWEST EXPECTED AMBIENT TEI\iIP <br />-"C <br />2 ) HIGHEST CONTINUOUS AMBIENT TEMPERATURE BASED ON ASHRAE HIGHEST <br />MONTH 2% DRY BULB TEMPERATURE FOR ASHRAE LOCATION MOST SIMILAR TO <br />INSTALLATION LOCATION HIGHEST CONTINUOUS TEMPERATURE <br />-"C2 ) 2005 ASHRAE FUNDEMENTATS 2olo DESIGN TEMPERATURES DO NOT EXCEED <br />47"C IN THE UNITED STATES (PAIM SPRINGS, CA IS 44,1"C) FOR LESS THAN 9 <br />CURRENT.CARRYING CONDUCTORS IN ROOF.MOUNTED SUNLIT CONDUIT AT <br />LEAST O 5" ABOVE ROOF AND USING THE OUTDOOR DESIGN TEMPERATURE OF <br />47OC OR LESS (ALL OF UNITED STATES), <br />a) 12 AWG,90"C CONDUCTORS ARE GENERALTY ACCEPTABLE FOR MODULES <br />WITH lsc OF 7 68 AMPS OR LESS WHEN PROTECTED BY A 12-AMP OR SMALLER <br />FUS E <br />b) 1O AWG, gO"C CONDUCTORS ARE GENERALLY ACCEPTABLE FOR MODULES <br />WITH lsc OF 9 6 AMPS OR LESS WHEN PROTECTED BY A 1s-Ai/P OR SMALLER <br />F USE <br />SIGN FOR INVERTER OCPD AND <br />AC DISCONNECT (IF USED) <br />SOLAR PV SYSTEM <br />AC POINT OF CONNECTION <br />Ac ourPUT cURRENT 16 <br />AC VOLTAGE 24O <br />THIS PANEL FED BY MULTIPLE <br />SOURCES (UTILITY AND SOLAR) <br />NOTES FOR INVERTER CIRCUITS (Gurde Section I and 9) <br />1) IF UTILITY REQUIRES A VISIBLE-BREAK SWITCH, DOES THIS SWITCH MEET THE <br />REOUIREIVENT? YES E) NO tr N/A tr <br />2) IF GENERATION METER REQUIRED, DOES THIS METER SOCKET IV]EET THE <br />REQUIREMENT? YES tr NO E] N/A E <br />3) SIZE PHOTOVOLTAIC POWER SOURCE (DC) CONDUCTORS BASED ON MAX <br />CURRENT ON NEC 690 53 SIGN OR OCPD RATING AT DISCONNECT <br />4) SIZE INVERTER OUTPUT CIRCUIT (AC) CONDUCTORS ACCORDING TO INVERTER <br />OCPD AMPERE RATING (See Guide Section 9) <br />5) TOTAL OF zo INVERTER OCPD(s), ONE FOR EACH INVERTER. DOES TOTAL <br />SUPPLY BREAKERS CO|\ilPLY WITH 120% EUSBAR EXCEPTION lN 690 64(8Xz)(a)?YESE NOtr <br />2a <br />F <br />d.oI <br />q <br />Uo <br />L <br />F <br />d <br />a <br />op <br />F <br />op <br />x <br />L!