My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
20166038 - Permit
PBA
>
Building
>
Permits
>
R
>
River Ln
>
1502 W River Ln
>
20166038 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 9:41:31 AM
Creation date
6/2/2021 9:41:25 AM
Metadata
Fields
Template:
Permit
Permit Number
20166038
Full Address
1502 W River Ln
Permit ID
242179
Master ID Number
2018-143711
Project Name
Miscellaneous Counter1 Permit
Street Number
001502
Street Direction
W
Street Name
River
Street Suffix
Ln
Building Use Code
Resid-1 unit
Job Types
Solar
Permit Type
Electrical
Applied Date
6/4/2018
Issued Date
6/4/2018
Finalized Date
6/26/2018
Flood Zone
AE-0602320144J
Description of Work
Installation of roof mounted PV system. 11 panels. 3.575kw. All fees paid on # 10196610
Nature of Work
Solar
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
EXPEDITED PERMIT PROCESS FOR SMALL-SCALE PV SYSTEMS <br />STANDARD STRING SYSTEM <br />The information in this guideline is inrended to help local jurisdictions and conLractors identify when PV system insEllarions <br />are simple, needing only a basic review. and when an insEllation is more complex. It is likely that 50%-75% of all residential <br />systems will comply wirh these simple criteria. For projects that fail ro meet the simple criteria, resolurion sreps have been <br />suggesled lo provide as a path to permit approval. <br />Requireil Infonnation for Permit: <br />l. Site plan showing location of major components on the property This drawing need not be exactly to scale, bur ir <br />should represent relative location of components at site (see supplied example site plan). PV arrays on dwellings <br />with a 3 perimeler space at ridge and sides may not need separate fire service review. <br />2. Electrical diagram showing PV array conhguration, wiring system, overcurrent protection, invener, disconnects, <br />required signs, and ac connection ro building (see supplied standard electrical diagram). <br />3. Specihcation sheets and installation manuals (if available) for all manufactured components including, but nor <br />limited to, PV modules, inverrer(s), combiner box, disconnects, and mounting system. <br />Step 1 : Structural Review o[ PV Array Mounting System <br />ls the array to be mounted on a defined, permitted roof structure?Yes E No <br />U No due to non-coupliant roo.f or a ground mount, submit completed worksheetJor the structure WKSI <br />Roof Infonnation: <br />1. Is the rooflng type lightweight (Yes = composition. lightweight masonry. metal, etc. .) <br />Comp shingle <br />YES <br />If No, submit completed worksheet for roof stucture WtrSI fNo = heayy masonry, slqte, etc...) <br />2 Does the roof have a single roof coveringt Elyes n r,lo <br />If No, submit completed worhsheet Jor roof structure WRSI. <br />3. Provide method and type of weatherproohng roof penetrations (e.g flashing, caulk)Flashing, geocell sealant <br />tem Manufacturer ZeP product Name and 14o,1"14 Comp Mount Type C <br />t ot PV Modules 3n6 nu;11 495 lbs <br />a Mounting Sys <br />b. Total Weigh <br />c Total Number of Attachment Poinrs 27 <br />d. Weight per Attachment Point (b: c)bs (if greater than 45 lbs, see WKS I ) <br />22.128 <br />e Maximum Spacing Between Attachment Points on a Rail 48 <br />maximum spacing allowed based on maximum design wind speed) <br />Tolal Surface Area of PV Modules (square feet)464 <br />nches (see product manual for <br />t. <br />e <br />Irl <br />Distributed Weight of PV Module on Roof (b + l)3.0 lbs/ftl <br />If distributed weight ol the PV system b greater than 5 lbsff , see WKS 1 . <br />Step 2: Elecvical Review of PV System (Calculations for Electrical Diagram) <br />In order for a PV system to be considered for an expedited permit process, the following must apply: <br />l PV modules, utility-interactive inverters, and combiner boxes are identifred for use in PV systems <br />2. The PV array is composed of 4 series strings or less per invefter <br />3. The toral inverter capacity has a continuous ac power output 13,440 Watts or less <br />4. The ac interconneclion point is on the load side of service disconnecting means (690.64(8)). <br />5. One of the standard electrical diagrams (El.l. El.la. El.lb. or El.lc) can be used to accurarely represenr rhe PV <br />system lnteractive PDF diagrams are available at www.solarabcs.org/permitting. <br />FilI out the standard electrical diagram completely. A guide to the electrico.l diagram is proyided to help the arylicant <br />understand each blank tofll in. If the electrical system is more complex than the standatd elecffical diagram can efJectively <br />communicqte, proyide an slternatiye diagram with appropriate d.etail. <br />2 ExpEDrrED PERMTT PRocEss FoR PV sysrEMs <br />M oltflting Sy stem Infonnatton: <br />l. Is the mounting structure an elgrneered product desrgned to mount PV modules wirh no more than an I8" gap <br />benealh thc module [rames? Llyes Ll tto <br />IJ No, provide d.etails oJ structurol attachment certijed b)/ a design proJessional. <br />2. For manufactured mounting systems, fill out information on the mounting syitem below:
The URL can be used to link to this page
Your browser does not support the video tag.