Laserfiche WebLink
sR0'133603 DA6050140, Page 2 of 3 <br />PC08: AISLE CLEARANCE <br />Provide a minimum aisle clearance of 30 inches at all walkways <br />PC09: FINISHES <br />All finishes are subject to evaluation by this Agency. This determination will be made at the time of the preliminary field <br />inspection. Finishes found not to be an compliance with current code requirements will not be accepted. <br />PC13: WALLS <br />Wall surfaces must be smooth, durable, and easily cleanable, such as drywall coated with semi-gloss enamel. ln areas <br />of high moisture, greenboard is strongly recommended. Surfaces beneath/behind sinks shall be FRP or equivalent. <br />PC'14: CEILING <br />Ceiling surfaces must be smooth, nonabsorbent, durable, and washable <br />EQUIPMENT SPECIFICATIONS <br />All new and replacement food-related or utensiFrelated equipment shall be certified or classified for SANITATION by an <br />American National Standards lnstitute (ANSI) accredited certification program. Example of these accredited programs <br />include NSF, UL, lntertek ETL, CSA etc. <br />All new and replacement electrical appliances shall meet applicable Underwriters Laboratories (UL) standards for <br />electrical equipment as determined by an ANSI accredited certiflcation program. <br />PC17: <br />HOOD CONSTRUCTION <br />Mechanical exhaust ventilation shall be required at or above all cooking equipment such as ranges, griddles, ovens, <br />deep fat fryers, barbecues, and rotisseries to effectively remove cooking odors, smoke, steam, grease, and vapors. <br />Hoods and mechanical ventilation must comply with all applicable requirements as set forth in the current edition of the <br />Uniform Mechanical Code, as adopted by the local building and fire authorities. <br />PC22i DRY FOOD STORAGE <br />Provide a minimum 32 linear feet or 96 running feet of dry food storage shelving units. This is in addition to the shelving <br />used for working storage (i.e., over and under counter storage) and refrigeration storage. <br />Within food establishments that have food preparation areas that total 400 square feet or less and that have 100 <br />customer seats or less, a minimum of 32 linear feet of dedicated floor space must be provided for back-up dry food <br />storage shelving. <br />All storage shelving must be accessible with 30 inch aisle clearance <br />PC26: WALK-IN UNITS <br />The walk-in refrigeration/freezer units must conform with applicable NSF lnternational standards and be completely <br />flashed to the building's walls and ceiling. The areas above walk-in units may not be used for storage. <br />PC28: LOcKEFJSHELF/POLEINSTALL <br />Lockers must be installed on six (6) inch high, easily cleanable legs, cantilevered off the wall, or on a minimum four (4) <br />inch high continuously coved curb or platform. L-angle legs are not acceptable. <br />To view the status of this project, visit our website at https://ochealtholancheck.ochca.com/ <br />PC16: <br />EQUIPMENT INSTALLATION <br />All equipment, including shelving, must be supported by six (6) inch high easily cleanable legs, commercial casters, or <br />completely sealed in position on a four (4) inch hagh continuously coved base or concrete curb. <br />Sneeze guard protection must be provided where food is displayed or customer self-service foods are proposed. <br />Displays of unpackaged food shall be shielded so as to intercept a direct line between the customer's mouth, assumed <br />to be betvyeen 54 and 60 inches above the floor, and the food being displayed. <br />PC21i