My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
10196906 - Permit
PBA
>
Building
>
Permits
>
S
>
Seventeenth St
>
2274 E Seventeenth St
>
10196906 - Permit
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/14/2023 10:02:56 AM
Creation date
6/2/2021 2:43:51 PM
Metadata
Fields
Template:
Permit
Permit Number
10196906
Full Address
2274 E Seventeenth St
Permit ID
243164
Master ID Number
2018-144389
Project Name
Mediterranean Guys Restaurant TI
Street Number
002274
Street Direction
E
Street Name
Seventeenth
Street Suffix
St
Building Use Code
Retail/Service
Job Types
Tenant Improvement
Permit Type
Building
Applied Date
7/2/2018
Issued Date
9/11/2018
Finalized Date
1/14/2019
Flood Zone
X-0602320164J
Description of Work
Remove interior walls to combine 2274 & 2276 into 2274. Add restroom & walk-in coolers. A grease interceptor is req'd-letter on file (Applicant said the landlord will be submitting plans for the grease interceptor for this address) Total 97 occupant
Nature of Work
TI/change of occupancy from B to A2. TOTAL 97 Occupant
Document Relationships
10196906 - Plan
(Plan)
Path:
\Building\Plans\S\Seventeenth St\2274 E Seventeenth St
71196 - Misc. Receipt
(Misc. Receipt)
Path:
\Building\Misc. Receipts\S\Seventeenth St\2274 E Seventeenth St
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
7
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
SR0133603 DA6050140, page 3 of 3 <br />PC29:' UTENSIL-WASHING FACILITIES <br />. The si:ze of the sink compartments and drainboards must be large enough to accommodate the largest vessel or utensil <br />used. However, the minimum size shall be 18" x 18" x 12" deep compartments with 18" x 18" drainboards or 16" x 20" x <br />12" deep with 16" x 20" drainboards. <br />PC30:FOOD PREPARATION SINK <br />The minimum requirements for a food preparation sink are: an NSF approved (18"x18"x12") single compartment, <br />stainless steel sink with an integral drainboard, or an approved preparation table adjoining it. The liquid waste from the <br />sink must drain into a floor sink via an indirect connection. <br />Pc39: CHEMICAL SHELF & MOP RACK <br />Provide a chemical storage shelf and mop rack in the janitorial area <br />PC41t WATER HEATER <br />When storage type water heater is proposed, provide a minimum energy input rating of 49,000 BTU'S or 11 total <br />connected KWs at 50 'F rise. <br />PC42: PLUMBING/ELECTRICAL <br />All conduit, plumbing, etc., not concealed within walls, must be installed at least six (6) inches off the floor and 'l /2 inch <br />away from walls. All exposed flex conduit is to be "seal-tight" or equivalent. <br />PC4/.i FLOOR SINKS <br />All equipment which generates condensate or similar liquid wastes shall be drained by means of indirect waste pipes <br />into a floor sink. Floor drains are not to be used in lieu of floor sinks. <br />All floor sinks must be at least half-exposed under the curb mounted equipment, or be in line with the front face of <br />elevated freestanding equipment, and located within 15 feet ofthe condensate producing equipment. <br />PC47i GREASETRAP/INTERCEPTOR <br />Grease traps are not required by this Agency. lf provided, a grease trap or interceptor shall not be located in a food or <br />utensil handling area. <br />PC49:AIR CURTAINS <br />Delivery doors shall be equipped with a door-activated air curtain device that delivers an air velocity of at least 750 feet <br />per minute, measured three (3) feet above the floor. The curtain of air shall cover the entire width of the door. For <br />delivery doors that are wider than four (4) feet, the air curtain must produce an air velocity of at least '1600 feet per <br />minute, as measured three (3) feet above the floor. <br />PC54:FACILITY ENCLOSURE <br />Each permanent food facility shall be fully enclosed in a building consasting of permanent floors, walls, and an overhead <br />structure that meet the minimum standards as prescribed by this part. Food facilities that are not fully enclosed on all <br />sides and that are in operation on January 1, '1985, shall not be required to meet the requirements of thjs section until <br />the facility is remodeled or has a significant menu change or its method of operation. This shall not be construed to <br />require the enclosure of dining areas or any other operation approved for outdoor food service. <br />This project was reviewed by IVAN FLORES, REHS (714)433-6062, <br />Your original assigned plan reviewer is IVAN FLORES, REHS (714)433-6062, <br />To view the status of this project, visit our website at https://ochealtholancheck.ochca.com/
The URL can be used to link to this page
Your browser does not support the video tag.