Laserfiche WebLink
SR0133603 DA6050140, page 3 of 3 <br />PC29:' UTENSIL-WASHING FACILITIES <br />. The si:ze of the sink compartments and drainboards must be large enough to accommodate the largest vessel or utensil <br />used. However, the minimum size shall be 18" x 18" x 12" deep compartments with 18" x 18" drainboards or 16" x 20" x <br />12" deep with 16" x 20" drainboards. <br />PC30:FOOD PREPARATION SINK <br />The minimum requirements for a food preparation sink are: an NSF approved (18"x18"x12") single compartment, <br />stainless steel sink with an integral drainboard, or an approved preparation table adjoining it. The liquid waste from the <br />sink must drain into a floor sink via an indirect connection. <br />Pc39: CHEMICAL SHELF & MOP RACK <br />Provide a chemical storage shelf and mop rack in the janitorial area <br />PC41t WATER HEATER <br />When storage type water heater is proposed, provide a minimum energy input rating of 49,000 BTU'S or 11 total <br />connected KWs at 50 'F rise. <br />PC42: PLUMBING/ELECTRICAL <br />All conduit, plumbing, etc., not concealed within walls, must be installed at least six (6) inches off the floor and 'l /2 inch <br />away from walls. All exposed flex conduit is to be "seal-tight" or equivalent. <br />PC4/.i FLOOR SINKS <br />All equipment which generates condensate or similar liquid wastes shall be drained by means of indirect waste pipes <br />into a floor sink. Floor drains are not to be used in lieu of floor sinks. <br />All floor sinks must be at least half-exposed under the curb mounted equipment, or be in line with the front face of <br />elevated freestanding equipment, and located within 15 feet ofthe condensate producing equipment. <br />PC47i GREASETRAP/INTERCEPTOR <br />Grease traps are not required by this Agency. lf provided, a grease trap or interceptor shall not be located in a food or <br />utensil handling area. <br />PC49:AIR CURTAINS <br />Delivery doors shall be equipped with a door-activated air curtain device that delivers an air velocity of at least 750 feet <br />per minute, measured three (3) feet above the floor. The curtain of air shall cover the entire width of the door. For <br />delivery doors that are wider than four (4) feet, the air curtain must produce an air velocity of at least '1600 feet per <br />minute, as measured three (3) feet above the floor. <br />PC54:FACILITY ENCLOSURE <br />Each permanent food facility shall be fully enclosed in a building consasting of permanent floors, walls, and an overhead <br />structure that meet the minimum standards as prescribed by this part. Food facilities that are not fully enclosed on all <br />sides and that are in operation on January 1, '1985, shall not be required to meet the requirements of thjs section until <br />the facility is remodeled or has a significant menu change or its method of operation. This shall not be construed to <br />require the enclosure of dining areas or any other operation approved for outdoor food service. <br />This project was reviewed by IVAN FLORES, REHS (714)433-6062, <br />Your original assigned plan reviewer is IVAN FLORES, REHS (714)433-6062, <br />To view the status of this project, visit our website at https://ochealtholancheck.ochca.com/