Laserfiche WebLink
47 SIGN COMPONENTS MANUAL (SAM)November 14,2012 <br />LED 10CV 24 PU <br />LED 10CC 350,120-240 0.175-0.120 2.3-28 0.350 10 VA <br />LED 10CC 350 PU <br />2. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />3. A suitable Fire and Electrical Enclosure shall be provided in the end product. <br />4. In the end product, power supply spacing to other heat producing <br />components shall be minimum 2 inches spacing to sidewalls, and minimum 2 inches spacing to top of enclosure. <br />5. These power supplies are only suitable for use in dry and damp locations. <br />Class 2 Power Supply, Models LED 60CV 12P, LED60CV 24P, LED 100 CV 8, LED 100 CV 12, LED 100 CV 24, LED 100 CV <br />48. <br />1. These power supplies have been evaluated to Class 2 output requirements for dc circuits with a maximum of one Class 2 <br />output. <br />2. The electrical ratings are as follows: <br />Input, 60 Hz. Output DC <br />Model V A V VA <br />LED 100 CV 8 100 - 277 1.3 - 0.5 8 100 <br />LED 100 CV 12 100 - 277 1.3 - 0.5 12 100 <br />LED 100 CV 24 100 - 277 1.3 - 0.5 24 96 <br />LED 100 CV 48 100 - 277 1.3 - 0.5 48 96 <br />LED 60CV 12P 100 - 277 0.8 - 0.3 12 60 <br />LED 60CV 24P 100 - 277 0.8 - 0.3 24 60 <br />3. These power supplies are only suitable for use in dry and damp locations. <br />4. In the end product, power supply spacing to other heat producing components shall be minimum 2 inches spacing to sidewalls, <br />and minimum 2 inches spacing to top of enclosure. <br />Company name or trademarks lightechâ„¢ Ughtech TIe <br />4 LED Driver / Hclogen Tran,forrnei, and model designation. <br /> 'GE LIGHTING SOLUTIONS LLC6/< BLDG 338E <br />1975 NOBLE RD <br />EAST CLEVELAND, OH 44112 USA <br />E219167 <br />Border tube kits, Includes Lens Cat. No. GExxBTL; Lens connector Cat. No. GE=BTLC; End cap Cat. No. GE=BTLEC; ED<terior <br />corner kit Cat. No. GExxBTLXC; Interior corner kit Cat. No. GE=BTLIC; Base reflector Cat. No. GEBTBR; Base connector Cat. <br />No. GEBTBC; Cam lock Cat. No. GEBTCL. Canopy Kits, Cat. No. GECPL (8 ft length), GECPEC (end cap), GECPLC, (lens <br />connector), GEBTBCL, GEBTBC. Light guide kits includes: Light guide Cat. No. GEXNLGXX-XXX, Light Guide End Cap Cat. <br />No. GEXXXNLGECZZ, XXX may be any alpha letter representing color. ZZ may be any alpha letter representing size. Light <br />Guide Connector Cat. No. GEXXXNLGYZZ, XXX may be any alpha letter representing color, Y can be any alpha character <br />describing the type of connector. ZZ may be any alpha letter representing size.. Mounting clip Cat. No. GEXNMCXX; Supply <br />wire Cat. No. GEXNSXX, Splice connector Cat. No. GEXNSC1; Weather box Cat. No. GEXWBXX-XXX. <br />1. Border Tube Kit, Canopy Kit and Light Guide Kit are for Wet Location only use when enclosing LED's connected to a Class 2 <br />circuit operating at under 30V continuous DC, 12.4 V interrupted at a rate of 10-200Hz DC, or 15 VAC. <br />2. The LED border tube kit and Canopy Kit was not evaluated as an electrical enclosure. <br />3. The LED border tube kit and Canopy Kit was not evaluated as a watertight housing. <br />LED power supplies, Cat. No. GEXLPS21, GEXNPS30-120, GEXNPS31-120 <br />1. This component has been judged on the basis of the required spacings in the Standard for Class 2 Power Units, UL 1310, <br />Fourth Edition, which would cover the component itself if submitted for Listing. <br />2.The supply terminals and connectors are suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. <br />3.The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40 C. <br />4. Leakage current measurements shall be performed when more than four LED drivers are used in the equipment or when the <br />LED driver is used in combination with other equipment in the end-use product. <br />5. The drivers are intended for installation inside an electrical enclosure. <br />6. The ground connection is not suitable as the equipment ground for a sign. Separate provision for sign grounding must be <br />provided. <br />7. The drivers are suitable for dry location use only except the drivers Models GEXNPS30-120 and GEXLPS21 are suitable for <br />damp location use. <br />LED array drivers, Models GEXLPS21-U, GEPS 12-60U, GE060/MVA/12T12T1-A. <br />1. These components have been judged on the basis of the required spacing in the Standard for Class 2 Power Units, UL 1310, <br />Fourth Edition, which would cover the component itself if submitted for Listing. <br />2. The terminals and connectors are suitable for factory wiring only of solid or tinned stranded No. 18 AWG conductors. <br />3. The equipment was submitted and tested for a maximum manufacturer's recommended ambient (Tmra) of 40°C. <br />4. The insulation system of the main isolation transformer designated (T2) in these models is a Class 105(A) insulation system. <br />Unless the modules are mounted as specified in condition of acceptability number 7, a temperature test is required when these <br />models installed within an electrical enclosure or raceway. <br />5. The maximum measured leakage current of a single unit is 0.49 mA. Leakage current measurements shall be performed when <br />multiple LED drivers are used in the final equipment or when the LED driver is used in combination with other equipment in the <br />end-use product.